:A computerized system for monitoring dose-area product (DAP) has been developed for region of interest (ROI) fluoroscopy in which patient exposure is reduced using an x-ray attenuating filter with an aperture. The system includes an IBM compatible computer which is connected through an IEEE-488 interface to an electrometer which measures the charge from a DAP ionization chamber. A digital input/output board connects the computer to the filter placement device to determine whether the filter is in or out of the beam, and to the x-ray generator to determine when the exposure is due to spot filming. The computer logs the DAP from conventional fluoroscopy, ROI fluoroscopy and spot filming separately, applying the appropriate calibration factor for each. Measured DAPs, fluoroscopic DAP rates and exposure times are displayed in real-time. The system has been installed in a GI fluoroscopic room so that the dose-reduction potential of ROI imaging can be evaluated.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Kezerashvili M,Bednarek DR,Rudin Sdoi
10.1088/0031-9155/42/4/001subject
Has Abstractpub_date
1997-04-01 00:00:00pages
613-23issue
4eissn
0031-9155issn
1361-6560journal_volume
42pub_type
杂志文章abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa8b36
更新日期:2017-10-03 00:00:00
abstract::This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical obs...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/7/2751
更新日期:2015-04-07 00:00:00
abstract::We have developed and tested an MR-compatible gamma probe to simultaneously obtain anatomical information and functional information during surgery. The probe consists of a probe head, an optical fibre bundle and a photo-multiplier tube (PMT). The NaI(T1) scintillator contained in the probe head is connected to a 7 m ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/15/005
更新日期:2004-08-07 00:00:00
abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/11/014
更新日期:2005-06-07 00:00:00
abstract::Non-invasively reconstructing the cardiac transmembrane potentials (TMPs) from body surface potentials can act as a regression problem. The support vector regression (SVR) method is often used to solve the regression problem, however the computational complexity of the SVR training algorithm is usually intensive. In t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/8/3237
更新日期:2015-04-21 00:00:00
abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/17/4961
更新日期:2014-09-07 00:00:00
abstract::Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respira...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/5/016
更新日期:2008-03-07 00:00:00
abstract::Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/24/7865
更新日期:2014-12-21 00:00:00
abstract::Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2ef5
更新日期:2019-08-14 00:00:00
abstract::Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabili...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/20/004
更新日期:2004-10-21 00:00:00
abstract::A mathematical procedure, using Fourier deconvolution, is described whereby diffusion-free proximity functions can be obtained from cloud-chamber data. Such non-diffused distributions can be used to obtain further microdosimetric and nanodosimetric quantities hitherto not available from experiments, thus making the cl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/11/004
更新日期:1988-11-01 00:00:00
abstract::Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertaintie...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5602
更新日期:2017-02-07 00:00:00
abstract::An original method for the analysis of oscillations of cutaneous blood flow has been developed, which makes use of laser Doppler flowmetry (LDF) data and is based on the continuous wavelet transform and adaptive wavelet theory. The potential of the method has been demonstrated in experiments with the response of micro...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/21/005
更新日期:2008-11-07 00:00:00
abstract::A semi-empirical theory has been derived that relates the aluminum equivalence of various materials used in diagnostic radiology to their attenuation coefficients. The dependence of the aluminum hardness (AHE) and attenuation (AAE) equivalent on the beam quality is described in terms of effective energy. This 'aluminu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/31/12/006
更新日期:1986-12-01 00:00:00
abstract::State of the art point-spread function (PSF) corrections implemented in positron emission tomography/computed tomography (PET/CT) reconstruction improved image quality and diagnostic performance but caused an increase in the standardized uptake value (SUV) compared to a conventional OSEM reconstruction system. The EAN...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaee27
更新日期:2018-11-26 00:00:00
abstract::The High-Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography (PET) scanner. Recently, a 3D filtered backprojection (3D-FBP) reconstruction method has been implemented to reduce bias in short duration frames, currently observed in 3D ordinary Poisson OSEM (3D-OP-OSEM) reconstruc...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/12/010
更新日期:2008-06-21 00:00:00
abstract::Measuring spin-spin relaxation times (T2) by quantitative MR imaging represents a potentially efficient tool to evaluate the physicochemical properties of various media. However, noise in MR images is responsible for uncertainties in the determination of T2 relaxation times, which limits the accuracy of parametric tis...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/11/011
更新日期:2006-06-07 00:00:00
abstract::Commercial TPSs typically model the tongue-and-groove (TG) by extending the projections of the leaf sides by a certain constant width. However, this model may produce discrepancies of as much as 7%-10% in the calculated average doses, especially for the High Definition multi-leaf collimator (MLC) (Hernandez et al 2017...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf098
更新日期:2018-12-10 00:00:00
abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...
journal_title:Physics in medicine and biology
pub_type: 临床试验,杂志文章
doi:10.1088/0031-9155/49/18/001
更新日期:2004-09-21 00:00:00
abstract::The exponential edge-gradient effect must arise in any x-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of x-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induc...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/3/010
更新日期:1981-05-01 00:00:00
abstract::Multi-atlas segmentation (MAS) has been widely used to automate the delineation of organs at risk (OARs) for radiotherapy. Label fusion is a crucial step in MAS to cope with the segmentation variabilities among multiple atlases. However, most existing label fusion methods do not consider the potential dosimetric impac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5ed9
更新日期:2017-05-07 00:00:00
abstract::The radiofrequency dielectric behaviour of packed human erythrocytes has been investigated in normal haemoglobins F and AA and also abnormal haemoglobins homozygous SS and heterozygous AS. Dielectric measurements were made in tightly packed blood cells at an average room temperature of 26.5 +/- 0.5 degrees C in the fr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/28/4/002
更新日期:1983-04-01 00:00:00
abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abc708
更新日期:2020-11-03 00:00:00
abstract::This study aims at investigating in real-time the structural and dynamical changes occurring in an ex vivo tissue during a microwave thermal ablation (MTA) procedure. The experimental set-up was based on ex vivo liver tissue inserted in a dedicated box, in which 3 fibre-optic (FO) temperature probes were introduced to...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1a67
更新日期:2019-05-31 00:00:00
abstract::We have developed and tested a GSO (gadolinium oxyorthosilicate) position-sensitive gamma detector which can be used with positron and single-photon radionuclides for imaging breast cancer or sentinel lymph node detection. Because GSO has a relatively good energy resolution for annihilation gammas as well as low energ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/2/018
更新日期:2006-01-21 00:00:00
abstract::We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification per...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/6/022
更新日期:2009-03-21 00:00:00
abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/14/017
更新日期:2008-07-21 00:00:00
abstract::We have investigated the tongue-and-groove effect on the IMRT dose distributions for a Varian MLC. We have compared the dose distributions calculated using the intensity maps with and without the tongue-and-groove effect. Our results showed that, for one intensity-modulated treatment field, the maximum tongue-and-groo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/4/310
更新日期:2001-04-01 00:00:00
abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aba7d1
更新日期:2020-07-21 00:00:00
abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa4fb
更新日期:2018-02-12 00:00:00