Aluminum equivalence of materials used in diagnostic radiology and its dependence on beam quality.

Abstract:

:A semi-empirical theory has been derived that relates the aluminum equivalence of various materials used in diagnostic radiology to their attenuation coefficients. The dependence of the aluminum hardness (AHE) and attenuation (AAE) equivalent on the beam quality is described in terms of effective energy. This 'aluminum equivalence approach' (ALEAP) gives estimates of the aluminum equivalent, regardless of spectral shape, that are usually within +/- 5% except when absorption edges are involved. A reasonable definition for the AHE of K-edge filters is offered. Suggestions are made for methods of testing for compliance with standards and regulations.

journal_name

Phys Med Biol

authors

Nagel HD

doi

10.1088/0031-9155/31/12/006

subject

Has Abstract

pub_date

1986-12-01 00:00:00

pages

1381-99

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

31

pub_type

杂志文章
  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations.

    abstract::In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/008

    authors: Jaillon F,Zheng W,Huang Z

    更新日期:2008-02-21 00:00:00

  • Staging of cervical cancer based on tumor heterogeneity characterized by texture features on (18)F-FDG PET images.

    abstract::The aim of the study is to assess the staging value of the tumor heterogeneity characterized by texture features and other commonly used semi-quantitative indices extracted from (18)F-FDG PET images of cervical cancer (CC) patients. Forty-two patients suffering CC at different stages were enrolled in this study. First...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5123

    authors: Mu W,Chen Z,Liang Y,Shen W,Yang F,Dai R,Wu N,Tian J

    更新日期:2015-07-07 00:00:00

  • Effect of endorectal balloon positioning errors on target deformation and dosimetric quality during prostate SBRT.

    abstract::An inflatable endorectal balloon (ERB) is often used during stereotactic body radiation therapy (SBRT) for treatment of prostate cancer in order to reduce both intrafraction motion of the target and risk of rectal toxicity. However, the ERB can exert significant force on the prostate, and this work assessed the impact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7995

    authors: Jones BL,Gan G,Kavanagh B,Miften M

    更新日期:2013-11-21 00:00:00

  • The Hug-Kellerer equation as the universal cell survival curve.

    abstract::The Hug-Kellerer (H-K) equation is one of the earliest proposed radiation cell survival curves. We examine this equation in view of the recent perceived need for a universal cell survival curve which would be applicable to single radiation fractions at high doses. We derive relationships between the three parameters o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/10/N01

    authors: Ekstrand KE

    更新日期:2010-05-21 00:00:00

  • 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.

    abstract::Wafer-scale CMOS active pixel sensors (APSs) have been developed recently for x-ray imaging applications. The small pixel pitch and low noise are very promising properties for medical imaging applications such as digital breast tomosynthesis (DBT). In this work, we evaluated experimentally and through modeling the ima...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/23/8977

    authors: Zhao C,Konstantinidis AC,Zheng Y,Anaxagoras T,Speller RD,Kanicki J

    更新日期:2015-12-07 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • Cone-beam CT using a mobile C-arm: a registration solution for IGRT with an optical tracking system.

    abstract::A method for registering images acquired from a prototype flat panel mobile C-arm, capable of kilovoltage (kV) cone-beam computed tomography (CT), to a linear accelerator (LINAC) isocenter is presented. A calibration procedure is performed which involves locating reflective markers placed on the C-arm and a phantom in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/005

    authors: Sorensen S,Mitschke M,Solberg T

    更新日期:2007-06-21 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • An extended diffraction-enhanced imaging method for implementing multiple-image radiography.

    abstract::Diffraction-enhanced imaging (DEI) is an analyser-based x-ray imaging method that produces separate images depicting the projected x-ray absorption and refractive properties of an object. Because the imaging model of DEI does not account for ultra-small-angle x-ray scattering (USAXS), the images produced in DEI can co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/011

    authors: Chou CY,Anastasio MA,Brankov JG,Wernick MN,Brey EM,Connor DM,Zhong Z

    更新日期:2007-04-07 00:00:00

  • Review of photon interaction cross section data in the medical and biological context.

    abstract::The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/1/001

    authors: Hubbell JH

    更新日期:1999-01-01 00:00:00

  • Assessment of histotripsy-induced liquefaction with diagnostic ultrasound and magnetic resonance imaging in vitro and ex vivo.

    abstract::Histotripsy is a therapeutic ultrasound modality under development to liquefy tissue mechanically via bubble clouds. Image guidance of histotripsy requires both quantification of the bubble cloud activity and accurate delineation of the treatment zone. In this study, magnetic resonance (MR) and diagnostic ultrasound i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab143f

    authors: Anthony GJ,Bollen V,Hendley S,Antic T,Sammet S,Bader KB

    更新日期:2019-05-02 00:00:00

  • Geometrical structures for radiation biology research as implemented in the TOPAS-nBio toolkit.

    abstract::Computational simulations, such as Monte Carlo track structure simulations, offer a powerful tool for quantitatively investigating radiation interactions within cells. The modelling of the spatial distribution of energy deposition events as well as diffusion of chemical free radical species, within realistic biologica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad8eb

    authors: McNamara AL,Ramos-Méndez J,Perl J,Held K,Dominguez N,Moreno E,Henthorn NT,Kirkby KJ,Meylan S,Villagrasa C,Incerti S,Faddegon B,Paganetti H,Schuemann J

    更新日期:2018-09-06 00:00:00

  • First experimental evidence of the feasibility of multi-color magnetic particle imaging.

    abstract::Magnetic particle imaging is a new approach to visualizing magnetic nanoparticles. It is capable of 3D real-time in vivo imaging of particles injected into the blood stream and is a candidate for medical imaging applications. To date, only one particle type has been imaged at a time, however, the ability to separate s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/1775

    authors: Rahmer J,Halkola A,Gleich B,Schmale I,Borgert J

    更新日期:2015-03-07 00:00:00

  • Optical studies of vaporization and stability of fluorescently labelled perfluorocarbon droplets.

    abstract::Droplets of liquid perfluorocarbon (PFC) are under study as the next generation of contrast agents for ultrasound (US). These droplets can be selectively vaporized into echogenic gas bubbles in situ by externally applied US, with numerous applications to diagnosis and therapy. However, little is known about the mechan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/21/7205

    authors: Reznik N,Seo M,Williams R,Bolewska-Pedyczak E,Lee M,Matsuura N,Gariepy J,Foster FS,Burns PN

    更新日期:2012-11-07 00:00:00

  • Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera.

    abstract::Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6029

    authors: Morozov A,Alves F,Marcos J,Martins R,Pereira L,Solovov V,Chepel V

    更新日期:2017-05-07 00:00:00

  • A method of improving the spatial resolution of treatments that involve a multileaf collimator.

    abstract::In this paper we present a novel method of reducing the dosimetric effects of the finite leaf width of a multileaf collimator (MLC) in conformal and intensity modulated radiotherapy (IMRT). This is achieved by decomposing the required high-resolution fluence distribution into two orthogonal components, which are deliv...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/304

    authors: Evans PM,Partridge M

    更新日期:2000-03-01 00:00:00

  • Local organ dose conversion coefficients for angiographic examinations of coronary arteries.

    abstract::New organ dose conversion coefficients for coronary angiographic interventions are presented, as well as dose distributions and resulting maximal local dose conversion coefficients in the relevant organs. For the Monte Carlo based simulations, voxel models of the human anatomy were employed which represent the average...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/003

    authors: Schlattl H,Zankl M,Hausleiter J,Hoeschen C

    更新日期:2007-08-07 00:00:00

  • Pre-treatment patient-specific stopping power by combining list-mode proton radiography and x-ray CT.

    abstract::The relative stopping power (RSP) uncertainty is the largest contributor to the range uncertainty in proton therapy. The purpose of this work was to develop a systematic method that yields accurate and patient-specific RSPs by combining (1) pre-treatment x-ray CT and (2) daily proton radiography of the patient. The me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7c42

    authors: Collins-Fekete CA,Brousmiche S,Hansen DC,Beaulieu L,Seco J

    更新日期:2017-08-03 00:00:00

  • Respiratory liver motion estimation and its effect on scanned proton beam therapy.

    abstract::Proton therapy with active scanning beam delivery has significant advantages compared to conventional radiotherapy. However, so far only static targets have been treated in this way, since moving targets potentially lead to interplay effects. For 4D treatment planning, information on the target motion is needed to cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/7/1779

    authors: Zhang Y,Boye D,Tanner C,Lomax AJ,Knopf A

    更新日期:2012-04-07 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • Temperature elevation in the eye of anatomically based human head models for plane-wave exposures.

    abstract::This study investigated the temperature elevation in the eye of anatomically based human head models for plane-wave exposures. The finite-difference time-domain method is used for analyzing electromagnetic absorption and temperature elevation. The eyes in the anatomic models have average dimensions and weight. Computa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/003

    authors: Hirata A,Watanabe S,Fujiwara O,Kojima M,Sasaki K,Shiozawa T

    更新日期:2007-11-07 00:00:00

  • Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study.

    abstract::Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/14/017

    authors: Wong JT,Molloi S

    更新日期:2008-07-21 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • A revised monitor source method for practical deadtime count loss compensation in clinical planar and SPECT studies.

    abstract::The aim of the study is to verify the fundamental assumption in the monitor source method, i.e. uniform fractional count loss across the field of view (FOV), and to introduce a revised monitor source method for SPECT deadtime correction that minimally interferes with the clinical protocol. SPECT images of non-uniform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1199

    authors: Siman W,Silosky M,Kappadath SC

    更新日期:2015-02-07 00:00:00

  • Transport calculations of depth-dose distributions for gadolinium neutron capture therapy.

    abstract::Depth-dose distributions were calculated for thermal and epithermal neutron fluence and capture gamma ray dose rates using a two-dimensional neutron-coupled gamma-ray transport code (DOT 3.5) for gadolinium neutron capture therapy. The results show that (i) a capture gamma-ray dose rate of 10 Gy h-1 was obtained with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/1/010

    authors: Matsumoto T

    更新日期:1992-01-01 00:00:00

  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclides.

    abstract::In addition to being a powerful clinical tool, Positron emission tomography (PET) is also used in small laboratory animal research to visualize and track certain molecular processes associated with diseases such as cancer, heart disease and neurological disorders in living small animal models of disease. However, dosi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/1/169

    authors: Xie T,Zaidi H

    更新日期:2013-01-07 00:00:00

  • Three-dimensional performance of a small-diameter positron emission tomograph.

    abstract::Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/2/010

    authors: Bloomfield PM,Myers R,Hume SP,Spinks TJ,Lammertsma AA,Jones T

    更新日期:1997-02-01 00:00:00