Comparative Monte Carlo study on the performance of integration- and list-mode detector configurations for carbon ion computed tomography.

Abstract:

:Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertainties in the estimated ion range of up to several millimeters. Ion CT (iCT) represents a favorable solution allowing to directly assess the RSP. In this simulation study we investigate the performance of the integration-mode configuration for carbon iCT, in comparison with a single-particle approach under the same set-up. The experimental detector consists of a stack of 61 air-filled parallel-plate ionization chambers, interleaved with 3 mm thick PMMA absorbers. By means of Monte Carlo simulations, this design was applied to acquire iCTs of phantoms of tissue-equivalent materials. An optimization of the acquisition parameters was performed to reduce the dose exposure, and the implications of a reduced absorber thickness were assessed. In order to overcome limitations of integration-mode detection in the presence of lateral tissue heterogeneities a dedicated post-processing method using a linear decomposition of the detector signal was developed and its performance was compared to the list-mode acquisition. For the current set-up, the phantom dose could be reduced to below 30 mGy with only minor image quality degradation. By using the decomposition method a correct identification of the components and a RSP accuracy improvement of around 2.0% was obtained. The comparison of integration- and list-mode indicated a slightly better image quality of the latter, with an average median RSP error below 1.8% and 1.0%, respectively. With a decreased absorber thickness a reduced RSP error was observed. Overall, these findings support the potential of iCT for low dose RSP estimation, showing that integration-mode detectors with dedicated post-processing strategies can provide a RSP accuracy comparable to list-mode configurations.

journal_name

Phys Med Biol

authors

Meyer S,Gianoli C,Magallanes L,Kopp B,Tessonnier T,Landry G,Dedes G,Voss B,Parodi K

doi

10.1088/1361-6560/aa5602

subject

Has Abstract

pub_date

2017-02-07 00:00:00

pages

1096-1112

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Robust fluence map optimization via alternating direction method of multipliers with empirical parameter optimization.

    abstract::For the treatment planning during intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT), beam fluence maps can be first optimized via fluence map optimization (FMO) under the given dose prescriptions and constraints to conformally deliver the radiation dose to the targets while sparin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/7/2838

    authors: Gao H

    更新日期:2016-04-07 00:00:00

  • Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

    abstract::We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/5/1361

    authors: Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

    更新日期:2013-03-07 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • An expression for backscatter factors for orthovoltage x-rays.

    abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/021

    authors: Xiao Y,Bjärngard B

    更新日期:1998-05-01 00:00:00

  • Accurate Monte Carlo modelling of the back compartments of SPECT cameras.

    abstract::Today, new single photon emission computed tomography (SPECT) reconstruction techniques rely on accurate Monte Carlo (MC) simulations to optimize reconstructed images. However, existing MC scintillation camera models which usually include an accurate description of the collimator and crystal, lack correct implementati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/1/006

    authors: Rault E,Staelens S,Van Holen R,De Beenhouwer J,Vandenberghe S

    更新日期:2011-01-07 00:00:00

  • Global point signature for shape analysis of carpal bones.

    abstract::We present a method based on spectral theory for the shape analysis of carpal bones of the human wrist. We represent the cortical surface of the carpal bone in a coordinate system based on the eigensystem of the two-dimensional Helmholtz equation. We employ a metric--global point signature (GPS)--that exploits the sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/4/961

    authors: Chaudhari AJ,Leahy RM,Wise BL,Lane NE,Badawi RD,Joshi AA

    更新日期:2014-02-21 00:00:00

  • Infrasonic analysis of carotid vibration as a diagnostic method in carotid insufficiency syndrome.

    abstract::The infrasonic part of the spectrum of the carotid artery wall vibration in the neck was obtained. Differences between the spectral content and vibrational amplitude in normal and occluded carotids were found. The application of this technique in clinical practice could be useful in the detection of the carotid insuff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/011

    authors: Anastassiades AJ,Petounis AD

    更新日期:1976-01-01 00:00:00

  • Radiance and particle fluence.

    abstract::The concepts of radiance and fluence are fundamental to the description of a radiation field. The International Commission on Radiological Units and Measurements (ICRU) has defined fluence in terms of the number of the radiation particles crossing a small sampling sphere. A second definition has been proposed in which...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/6/011

    authors: Papiez L,Battista JJ

    更新日期:1994-06-01 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • Amplitude-based data selection for optimal retrospective reconstruction in micro-SPECT.

    abstract::Respiratory motion can blur the tomographic reconstruction of positron emission tomography or single-photon emission computed tomography (SPECT) images, which subsequently impair quantitative measurements, e.g. in the upper abdomen area. Respiratory signal phase-based gated reconstruction addresses this problem, but d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/8/2657

    authors: Breuilly M,Malandain G,Guglielmi J,Marsault R,Pourcher T,Franken PR,Darcourt J

    更新日期:2013-04-21 00:00:00

  • Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.

    abstract::Focused ultrasound and microbubbles have been extensively used to generate therapeutic bioeffects. Despite encouraging in vivo results, there remains poor control of the magnitude and spatial distribution of these bioeffects due to the limited ability of conventional pulse shapes and sequences to control cavitation dy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6941

    authors: Pouliopoulos AN,Bonaccorsi S,Choi JJ

    更新日期:2014-11-21 00:00:00

  • Numerical considerations for interface reflections in medical ultrasound.

    abstract::The original concept of the echo mechanism in diagnostic medical ultrasound--of step impedance discontinuities--is investigated in terms of the numerical implications of more refined models. The effect of a discontinuity in the attenuation coefficients is found to have as much significance as the impedance discontinui...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/001

    authors: Chivers RC,Santosa F

    更新日期:1986-08-01 00:00:00

  • Wavelet-packet-based texture analysis for differentiation between benign and malignant liver tumours in ultrasound images.

    abstract::The purpose of this study was to apply a novel method of multiscale echo texture analysis for distinguishing benign (hemangiomas) from malignant (hepatocellular carcinomas (HCCs) and metastases) focal liver lesions in B-mode ultrasound images. In this method, regions of interest (ROIs) extracted from within the lesion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/22/008

    authors: Yoshida H,Casalino DD,Keserci B,Coskun A,Ozturk O,Savranlar A

    更新日期:2003-11-21 00:00:00

  • The replacement correction factors for cylindrical chambers in high-energy photon beams.

    abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/014

    authors: Wang LL,Rogers DW

    更新日期:2009-03-21 00:00:00

  • A new approach to account for the medium-dependent effect in model-based dose calculations for kilovoltage x-rays.

    abstract::This study presents a new approach to accurately account for the medium-dependent effect in model-based dose calculations for kilovoltage (kV) x-rays. This approach is based on the hypothesis that the correction factors needed to convert dose from model-based dose calculations to absorbed dose-to-medium depend on both...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/011

    authors: Pawlowski JM,Ding GX

    更新日期:2011-07-07 00:00:00

  • Relating two techniques for handling uncertainties in IMRT optimization.

    abstract::Radiotherapy treatment planning is associated with uncertainties. Examples are uncertainties in the tumour location due to organ movement or the inter/intra observer variability in target definition. Different approaches to incorporate uncertainties into IMRT optimization have been proposed. In this note, we point out...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/N04

    authors: Unkelbach J,Oelfke U

    更新日期:2006-12-07 00:00:00

  • The GSF family of voxel phantoms.

    abstract::Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/47/1/307

    authors: Petoussi-Henss N,Zanki M,Fill U,Regulla D

    更新日期:2002-01-07 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • Automatic extraction of pectoral muscle in the MLO view of mammograms.

    abstract::A mammogram is the standard modality used for breast cancer screening. Computer-aided detection (CAD) approaches are helpful for improving breast cancer detection rates when applied to mammograms. However, automated analysis of a mammogram often leads to inaccurate results in the presence of the pectoral muscle. There...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/23/8493

    authors: Feudjio CK,Klein J,Tiedeu A,Colot O

    更新日期:2013-12-07 00:00:00

  • Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays.

    abstract::The dose-response of LiF:Mg,Ti (TLD-100) exposed to 15 and 35 kVp (8.0 +/- 0.1 and 8.1 +/- 0.1 keV effective energy respectively) x-rays and 60Co gamma-rays has been measured in the dose interval from (1.2-5.4) x 10(3) Gy for x-rays, and from 0.14 to 850 Gy for gamma-rays. In both cases the total TL signal and glow cu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/006

    authors: Gamboa-deBuen I,Buenfil AE,Ruiz CG,Rodríguez-Villafuerte M,Flores A,Brandan ME

    更新日期:1998-08-01 00:00:00

  • Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas.

    abstract::Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5705

    authors: Schena E,Saccomandi P,Giurazza F,Caponero MA,Mortato L,Di Matteo FM,Panzera F,Del Vescovo R,Beomonte Zobel B,Silvestri S

    更新日期:2013-08-21 00:00:00

  • Development of 4D mathematical observer models for the task-based evaluation of gated myocardial perfusion SPECT.

    abstract::This paper presents two 4D mathematical observer models for the detection of motion defects in 4D gated medical images. Their performance was compared with results from human observers in detecting a regional motion abnormality in simulated 4D gated myocardial perfusion (MP) SPECT images. The first 4D mathematical obs...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/7/2751

    authors: Lee TS,Frey EC,Tsui BM

    更新日期:2015-04-07 00:00:00

  • Task-based measures of image quality and their relation to radiation dose and patient risk.

    abstract::The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/60/2/R1

    authors: Barrett HH,Myers KJ,Hoeschen C,Kupinski MA,Little MP

    更新日期:2015-01-21 00:00:00

  • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

    abstract::Developments in positron emission tomography (PET) technology have resulted in systems with finer detector elements designed to further improve spatial resolution. However, there is a limit to what extent reducing detector element size will improve spatial resolution in PET. The spatial resolution of PET imaging is li...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/019

    authors: Levin CS,Hoffman EJ

    更新日期:1999-03-01 00:00:00

  • Is it necessary to plan with safety margins for actively scanned proton therapy?

    abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/011

    authors: Albertini F,Hug EB,Lomax AJ

    更新日期:2011-07-21 00:00:00

  • Exploration of tradeoffs in intensity-modulated radiotherapy.

    abstract::The purpose of this study is to calculate Pareto surfaces in multi-criteria radiation treatment planning and to analyse the dependency of the Pareto surfaces on the objective functions used for the volumes of interest. We develop a linear approach that allows us to calculate truly Pareto optimal treatment plans, and w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/24/007

    authors: Craft D,Halabi T,Bortfeld T

    更新日期:2005-12-21 00:00:00

  • Magnetorelaxometric quantification of magnetic nanoparticles in an artery model after ex vivo magnetic drug targeting.

    abstract::In magnetic drug targeting a chemotherapeutic agent is bound to coated magnetic nanoparticles, which are administered to the blood vessel system and subsequently focused by an external applied magnetic field. The optimization of intra-arterial magnetic drug targeting (MDT) requires detailed knowledge about the biodist...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/18/N03

    authors: Richter H,Wiekhorst F,Schwarz K,Lyer S,Tietze R,Alexiou Ch,Trahms L

    更新日期:2009-09-21 00:00:00

  • Optimization of the artificial urinary sphincter: modelling and experimental validation.

    abstract::The artificial urinary sphincter should be long enough to prevent strangulation effects of the urethral tissue and short enough to avoid the improper dissection of the surrounding tissue. To optimize the sphincter length, the empirical three-parameter urethra compression model is proposed based on the mechanical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/023

    authors: Marti F,Leippold T,John H,Blunschi N,Müller B

    更新日期:2006-03-07 00:00:00

  • A further assessment of an electromagnetic method to measure body composition.

    abstract::Two experimental investigations of the electromagnetic method to measure body composition are presented. In the first experiment, the impedance of a single-loop transmitting antenna, located at the centre of a 150 m helical receiving coil, was observed to have a sharp minimum at 2.40 MHz. The impedance of the antenna ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/011

    authors: Sutcliffe JF,Smye SW,Smith MA

    更新日期:1995-04-01 00:00:00