Relating two techniques for handling uncertainties in IMRT optimization.

Abstract:

:Radiotherapy treatment planning is associated with uncertainties. Examples are uncertainties in the tumour location due to organ movement or the inter/intra observer variability in target definition. Different approaches to incorporate uncertainties into IMRT optimization have been proposed. In this note, we point out a relation between two previously published methods: the coverage probability approach and the concept of optimizing the expectation value of an objective function that depends on a set of random variables. Both concepts are generally different, but turn out to be equivalent in special cases.

journal_name

Phys Med Biol

authors

Unkelbach J,Oelfke U

doi

10.1088/0031-9155/51/23/N04

subject

Has Abstract

pub_date

2006-12-07 00:00:00

pages

N423-7

issue

23

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)24645-1

journal_volume

51

pub_type

杂志文章
  • Noninvasive reconstruction of cardiac transmembrane potentials using a kernelized extreme learning method.

    abstract::Non-invasively reconstructing the cardiac transmembrane potentials (TMPs) from body surface potentials can act as a regression problem. The support vector regression (SVR) method is often used to solve the regression problem, however the computational complexity of the SVR training algorithm is usually intensive. In t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3237

    authors: Jiang M,Zhang H,Zhu L,Cao L,Wang Y,Xia L,Gong Y

    更新日期:2015-04-21 00:00:00

  • Calculation of 10 MV x-ray spectra emitted by a medical linear accelerator using the BFGS quasi-Newton method.

    abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/2/014

    authors: Shimozato T,Tabushi K,Kitoh S,Shiota Y,Hirayama C,Suzuki S

    更新日期:2007-01-21 00:00:00

  • 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.

    abstract::When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is compl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/020

    authors: Paganetti H,Jiang H,Trofimov A

    更新日期:2005-03-07 00:00:00

  • Fourier rebinning of time-of-flight PET data.

    abstract::This paper explores fast reconstruction strategies for 3D time-of-flight (TOF) positron emission tomography (PET), based on 2D data rebinning. Starting from pre-corrected 3D TOF data, a rebinning algorithm estimates for each transaxial slice the 2D TOF sinogram that would have been acquired by a single-ring scanner. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/12/002

    authors: Defrise M,Casey ME,Michel C,Conti M

    更新日期:2005-06-21 00:00:00

  • Treatment plan modification using voxel-based weighting factors/dose prescription.

    abstract::Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/315

    authors: Wu C,Olivera GH,Jeraj R,Keller H,Mackie TR

    更新日期:2003-08-07 00:00:00

  • Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning.

    abstract::Following the publication of ICRU Report 50, the concepts of GTV (gross tumour volume). CTV (clinical target volume) and PTV (planning target volume) are being used in radiotherapy planning with increasing frequency. In 3D planning, the GTV (or CTV) is normally outlined by the clinician in CT or MRI slices. The PTV is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/011

    authors: Stroom JC,Storchi PR

    更新日期:1997-04-01 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • The investigation of different cameras for in-beam PET imaging.

    abstract::In situ and in vivo treatment plan verification and beam monitoring as well as dose control during heavy-ion tumour therapy can be performed in principle by measurements of range distributions of beta(+)-emitting nuclei by means of PET techniques. For this purpose the performance of different types of positron camera ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/2/006

    authors: Pawelke J,Byars L,Enghardt W,Fromm WD,Geissel H,Hasch BG,Lauckner K,Manfrass P,Schardt D,Sobiella M

    更新日期:1996-02-01 00:00:00

  • Response of x-ray intensifying screens to scattered and primary radiation.

    abstract::The energy dependence of the luminance ratio due to scattered and primary radiation has been determined for four types of X-ray intensifying screens. A water phantom of 30 cm X 30 cm X 20 cm was used as the scattering medium. Ten narrow band X-ray spectra were used as incident radiation: the mean energies of these spe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/007

    authors: Koedooder K,Venema HW

    更新日期:1984-10-01 00:00:00

  • Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures.

    abstract::Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8087

    authors: Panayiotou M,Rhode KS,King AP,Ma Y,Cooklin M,O'Neill M,Gill J,Rinaldi CA,Housden RJ

    更新日期:2015-10-21 00:00:00

  • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent.

    abstract::A single photon absorptiometry method to measure the arterial concentration of injected iodinated contrast agent was developed. A prototype absorptiometry unit was built which consists of either a square or circular cross section acrylic (polymethylmethacrylate) cuvette connected to an arterial catheter at one end and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/9/002

    authors: Yeung WT,Lee TY,Del Maestro RF,Kozak R,Bennett JD,Brown T

    更新日期:1992-09-01 00:00:00

  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • Improved correction for the tissue fraction effect in lung PET/CT imaging.

    abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7387

    authors: Holman BF,Cuplov V,Millner L,Hutton BF,Maher TM,Groves AM,Thielemans K

    更新日期:2015-09-21 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • Reduced-order constrained optimization in IMRT planning.

    abstract::This paper presents a new algorithm for constrained intensity-modulated radiotherapy (IMRT) planning, made tractable by a dimensionality reduction using a set of plans obtained by fast, unconstrained optimizations. The main result is to reduce planning time by an order of magnitude, producing viable five field prostat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/007

    authors: Lu R,Radke RJ,Yang J,Happersett L,Yorke E,Jackson A

    更新日期:2008-12-07 00:00:00

  • Simultaneous minimization of leaf travel distance and tongue-and-groove effect for segmental intensity-modulated radiation therapy.

    abstract::This paper introduces a method to simultaneously minimize the leaf travel distance and the tongue-and-groove effect for IMRT leaf sequences to be delivered in segmental mode. The basic idea is to add a large enough number of openings through cutting or splitting existing openings for those leaf pairs with openings few...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/23/009

    authors: Dai J,Que W

    更新日期:2004-12-07 00:00:00

  • Continuous bed motion on clinical scanner: design, data correction, and reconstruction.

    abstract::With the addition of variable bed speed capabilities, continuous bed motion (CBM) becomes an acquisition generalization for axial sensitivity modeling and therefore a flexible tool in axial local image quality adjustment. In this paper, we describe the principles behind CBM mode planning and its influence on image rec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/6153

    authors: Panin VY,Smith AM,Hu J,Kehren F,Casey ME

    更新日期:2014-10-21 00:00:00

  • An iodine-125 thyroid measurement method.

    abstract::A two-probe technique has been developed to measure 125I in the thyroid. In this technique simultaneous emissions from a source are detected as coincidence events between two probes rather than as a sum peak in a single probe (the sum peak method). The background count rate when counting coincidence events between pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/3/004

    authors: Burns PA,Peggie JR

    更新日期:1980-05-01 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • Ultrasound scattering from spherical tumours.

    abstract::The interaction of biomedical ultrasound with spherical tumours in the human body is investigated using analytic methods which predict the angular distribution of the ultrasound scattered by the tumour. Both the tumour and the surrounding tissue are considered to be lossy elastic media, which support shear-wave modes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/11/001

    authors: Hinders MK,Collins JJ,Collins MM,Fang TM,Sandri GV

    更新日期:1992-11-01 00:00:00

  • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

    abstract::A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at differe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/018

    authors: Marchant TE,Amer AM,Moore CJ

    更新日期:2008-02-21 00:00:00

  • PBS machine interlocks using EWMA.

    abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/400

    authors: Clasie BM,Kooy HM,Flanz JB

    更新日期:2016-01-07 00:00:00

  • A theoretical model for respiratory motion artifacts in free-breathing CT scans.

    abstract::Successful radiotherapy treatment depends heavily upon the accuracy of patient geometry captured during treatment simulation using computed tomography (CT) scans. Radiotherapy patients are often scanned under free breathing, and respiratory motion can cause severe artifacts in CT scans, including shortening, elongatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/018

    authors: Lewis JH,Jiang SB

    更新日期:2009-02-07 00:00:00

  • High-energy x-ray Talbot-Lau radiography of a human knee.

    abstract::We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7721

    authors: Horn F,Gelse K,Jabari S,Hauke C,Kaeppler S,Ludwig V,Meyer P,Michel T,Mohr J,Pelzer G,Rieger J,Riess C,Seifert M,Anton G

    更新日期:2017-08-01 00:00:00

  • NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner.

    abstract::Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6749

    authors: Boisson F,Wimberley CJ,Lehnert W,Zahra D,Pham T,Perkins G,Hamze H,Gregoire MC,Reilhac A

    更新日期:2013-10-07 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound.

    abstract::Ultrasound may provide a quantitative technique for the characterization of cartilage changes typical of early osteoarthrosis. In this study, specific changes in bovine articular cartilage were induced using collagenase and chondroitinase ABC, enzymes that selectively degrade collagen fibril network and digest proteog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/303

    authors: Töyräs J,Rieppo J,Nieminen MT,Helminen HJ,Jurvelin JS

    更新日期:1999-11-01 00:00:00

  • Population and patient-specific target margins for 4D adaptive radiotherapy to account for intra- and inter-fraction variation in lung tumour position.

    abstract::In this work, five 4D image-guidance strategies (two population, an offline adaptive and two online strategies) were evaluated that compensated for both inter- and intra-fraction variability such as changes to the baseline tumour position and respiratory pattern. None of the strategies required active motion compensat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/1/017

    authors: Hugo GD,Yan D,Liang J

    更新日期:2007-01-07 00:00:00