Potential for reducing the numbers of SiPM readout surfaces of laser-processed X'tal cube PET detectors.

Abstract:

:We are developing a three-dimensional (3D) position-sensitive detector with isotropic spatial resolution, the X'tal cube. Originally, our design consisted of a crystal block for which all six surfaces were covered with arrays of multi-pixel photon counters (MPPCs). In this paper, we examined the feasibility of reducing the number of surfaces on which a MPPC array must be connected with the aim of reducing the complexity of the system. We evaluated two kinds of laser-processed X'tal cubes of 3 mm and 2 mm pitch segments while varying the numbers of the 4 × 4 MPPC arrays down to two surfaces. The sub-surface laser engraving technique was used to fabricate 3D grids into a monolithic crystal block. The 3D flood histograms were obtained by the Anger-type calculation. Two figures of merit, peak-to-valley ratios and distance-to-width ratios, were used to evaluate crystal identification performance. Clear separation was obtained even in the 2-surface configuration for the 3 mm X'tal cube, and the average peak-to-valley ratios and the distance-to-width ratios were 6.7 and 2.6, respectively. Meanwhile, in the 2 mm X'tal cube, the 6-surface configuration could separate all crystals and even the 2-surface case could also, but the flood histograms were relatively shrunk in the 2-surface case, especially on planes parallel to the sensitive surfaces. However, the minimum peak-to-valley ratio did not fall below 3.9. We concluded that reducing the numbers of MPPC readout surfaces was feasible for both the 3 mm and the 2 mm X'tal cubes.

journal_name

Phys Med Biol

authors

Hirano Y,Inadama N,Yoshida E,Nishikido F,Murayama H,Watanabe M,Yamaya T

doi

10.1088/0031-9155/58/5/1361

subject

Has Abstract

pub_date

2013-03-07 00:00:00

pages

1361-74

issue

5

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions.

    abstract::In this paper, we investigate an off-line strategy to incorporate inter-fraction organ motion in IMRT treatment planning. It was suggested that inverse planning could be based on a probability distribution of patient geometries instead of a single snap shot. However, this concept is connected to two intrinsic problems...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/17/013

    authors: Unkelbach J,Oelfke U

    更新日期:2004-09-07 00:00:00

  • Dose measurements in inhomogeneous bone/tissue and lung/tissue phantoms for angiography using synchrotron radiation.

    abstract::For angiography using synchrotron radiation we measured the absorbed dose distribution in inhomogeneous phantoms with thin LiF:Mg, Cu, P, LiF:Mg, Ti thermoluminescent dosimeters (TLDs) in tissue and lung substitutes, and with Mg2SiO4:Tb TLDs in bone substitute for 33.32 keV monoenergetic photons from synchrotron radia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/3/308

    authors: Nariyama N,Namito Y,Ban S,Hirayama H

    更新日期:2001-03-01 00:00:00

  • Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac.

    abstract::In this work we present the first delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. The machine's current IMRT based control system was modified suitably to enable dynamic delivery of radiation, for the purpose of exploring MRI-guided radiation therapy adaptation modes in a research setti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd66d

    authors: Kontaxis C,Woodhead PL,Bol GH,Lagendijk JJW,Raaymakers BW

    更新日期:2020-12-23 00:00:00

  • Comparison of dosimetric standards of USA and France for HDR brachytherapy.

    abstract::A bilateral comparison of national dosimetric standards for high dose rate brachytherapy has been conducted between the Laboratoire National Henri Becquerel and the University of Wisconsin Accredited Dosimetry Calibration Laboratory. A complete overview of the methods that are currently in use to establish the two nat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/50/9/003

    authors: Douysset G,Gouriou J,Delaunay F,DeWerd L,Stump K,Micka J,Laboratoire National Henri Becquerel.,University of Wisconsin Accredited Dosimetry Calibration Laboratory.

    更新日期:2005-05-07 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • A method for photon beam Monte Carlo multileaf collimator particle transport.

    abstract::Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/17/312

    authors: Siebers JV,Keall PJ,Kim JO,Mohan R

    更新日期:2002-09-07 00:00:00

  • Role of skin tissue layers and ultra-structure in transcutaneous electrical stimulation including tDCS.

    abstract:BACKGROUND:During transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), current density concentration around the electrode edges that is predicted by simplistic skin models does not match experimental observations of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb7c1

    authors: Khadka N,Bikson M

    更新日期:2020-09-11 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

    abstract::Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/010

    authors: Pukala J,Meeks SL,Bova FJ,Langen KM

    更新日期:2011-12-21 00:00:00

  • Feasibility of polymer gel-based measurements of radiation isocenter accuracy in magnetic fields.

    abstract::For conventional irradiation devices, the radiation isocenter accuracy is determined by star shot measurements on films. In magnetic resonance (MR)-guided radiotherapy devices, the results of this test may be altered by the magnetic field and the need to align the radiation and imaging isocenter may require a modifica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac228

    authors: Dorsch S,Mann P,Lang C,Haering P,Runz A,Karger CP

    更新日期:2018-05-29 00:00:00

  • Head scatter modelling for irregular field shaping and beam intensity modulation.

    abstract::Scattered radiation from within the treatment head can contribute significant dose to all parts of a radiotherapy treatment field. A multileaf collimator may be used to create an arbitrarily shaped field, and may also be used, under dynamic control, to modulate the beam intensity over the field. This method of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/9/006

    authors: Hounsell AR,Wilkinson JM

    更新日期:1997-09-01 00:00:00

  • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.

    abstract::Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/7/003

    authors: Baker SJ,Budgell GJ,MacKay RI

    更新日期:2005-04-07 00:00:00

  • Estimation of tissue resistivities from multiple-electrode impedance measurements.

    abstract::In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/001

    authors: Eyüboğlu BM,Pilkington TC,Wolf PD

    更新日期:1994-01-01 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo.

    abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/18/001

    authors: Kolen AF,Miller NR,Ahmed EE,Bamber JC

    更新日期:2004-09-21 00:00:00

  • Calculation of electron beam dose distributions for arbitrarily shaped fields.

    abstract::A method for the calculation of absorbed dose distributions of arbitrarily shaped electron beams is presented. Isodose distributions and output factors of treatment fields can be predicted with good accuracy, without the need for any dose measurement in the actual field. A Gaussian pencil beam model is employed with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/6/007

    authors: Bruinvis IA,Van Amstel A,Elevelt AJ,Van der Laarse R

    更新日期:1983-06-01 00:00:00

  • Development of a synthetic single crystal diamond dosimeter for dose measurement of clinical proton beams.

    abstract::The scope of this work was to develop a synthetic single crystal diamond dosimeter (SCDD-Pro) for accurate relative dose measurements of clinical proton beams in water. Monte Carlo simulations were carried out based on the MCNPX code in order to investigate and reduce the dose curve perturbation caused by the SCDD-Pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa70cf

    authors: Moignier C,Tromson D,de Marzi L,Marsolat F,García Hernández JC,Agelou M,Pomorski M,Woo R,Bourbotte JM,Moignau F,Lazaro D,Mazal A

    更新日期:2017-07-07 00:00:00

  • Evaluation of factors to convert absorbed dose calibrations from graphite to water for the NPL high-energy photon calibration service.

    abstract::The National Physical Laboratory (NPL) provides a high-energy photon calibration service using 4-19 MV x-rays and 60Co gamma-radiation for secondary standard dosemeters in terms of absorbed dose to water. The primary standard used for this service is a graphite calorimeter and so absorbed dose calibrations must be con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/3/306

    authors: Nutbrown RF,Duane S,Shipley DR,Thomas RA

    更新日期:2002-02-07 00:00:00

  • Are phantoms useful for predicting the potential of dose reduction in full-field digital mammography?

    abstract::A phantom study was performed in full-field digital mammography to investigate the opportunity and the magnitude of a possible dose reduction that would leave the image quality above the accepted thresholds associated with some classical phantoms. This preliminary work is intended to lay the groundwork for a future cl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/015

    authors: Gennaro G,Katz L,Souchay H,Alberelli C,di Maggio C

    更新日期:2005-04-21 00:00:00

  • A 3D point-kernel multiple scatter model for parallel-beam SPECT based on a gamma-ray buildup factor.

    abstract::A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient bod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/004

    authors: Marinkovic P,Ilic R,Spaic R

    更新日期:2007-10-07 00:00:00

  • First experimental evidence of the feasibility of multi-color magnetic particle imaging.

    abstract::Magnetic particle imaging is a new approach to visualizing magnetic nanoparticles. It is capable of 3D real-time in vivo imaging of particles injected into the blood stream and is a candidate for medical imaging applications. To date, only one particle type has been imaged at a time, however, the ability to separate s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/1775

    authors: Rahmer J,Halkola A,Gleich B,Schmale I,Borgert J

    更新日期:2015-03-07 00:00:00

  • Analysis of RF exposure in the head tissues of children and adults.

    abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/019

    authors: Wiart J,Hadjem A,Wong MF,Bloch I

    更新日期:2008-07-07 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • Measurement of the hyperelastic properties of 44 pathological ex vivo breast tissue samples.

    abstract::The elastic and hyperelastic properties of biological soft tissues have been of interest to the medical community. There are several biomedical applications where parameters characterizing such properties are critical for a reliable clinical outcome. These applications include surgery planning, needle biopsy and brach...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/020

    authors: O'Hagan JJ,Samani A

    更新日期:2009-04-21 00:00:00

  • Examination of errors caused by random summing in in vivo prompt gamma ray analysis.

    abstract::A technique is described for examining the mode of operation of radiation detectors and estimating the losses and gains caused by random summing effects in spectra acquired at high counting rates. The technique is applied to estimating the errors caused by random summing when measuring the amounts of carbon and nitrog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/8/010

    authors: Yankuba S,Oldroyd B,Metcalfe SC,Godfrey JE,Oxby CB

    更新日期:1989-08-01 00:00:00

  • Monte Carlo calculations of the energy response of lithium dosemeters to high energy electrons (less than 30 MeV).

    abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/003

    authors: O'Brien K

    更新日期:1977-09-01 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • Threshold-driven optimization for reference-based auto-planning.

    abstract::We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa731

    authors: Long T,Chen M,Jiang S,Lu W

    更新日期:2018-02-08 00:00:00

  • Improving mass detection using combined feature representations from projection views and reconstructed volume of DBT and boosting based classification with feature selection.

    abstract::In digital breast tomosynthesis (DBT), image characteristics of projection views and reconstructed volume are different and both have the advantage of detecting breast masses, e.g. reconstructed volume mitigates a tissue overlap, while projection views have less reconstruction blur artifacts. In this paper, an improve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/22/8809

    authors: Kim DH,Kim ST,Ro YM

    更新日期:2015-11-21 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00