Calculation of electron beam dose distributions for arbitrarily shaped fields.

Abstract:

:A method for the calculation of absorbed dose distributions of arbitrarily shaped electron beams is presented. Isodose distributions and output factors of treatment fields can be predicted with good accuracy, without the need for any dose measurement in the actual field. A Gaussian pencil beam model is employed with two different pencil beams for each electron beam energy. The values of the parameters of the pencil beam dose distributions are determined from a set of measurements of broad beam distributions; in this way the influence of electrons scattered by the applicator walls is taken into account. The dose distribution of electrons scattered from high atomic number metal frames, which define the treatment field contour at the skin, is calculated separately and added. This calculation is based on experimentally derived data. The method has been tested for beams with 6, 10, 14 and 20 MeV electron energy. The distance between calculated and measured isodose lines with values between 10 and 90% is under 0.3 cm. The difference between calculated and measured output factors does not exceed 2%.

journal_name

Phys Med Biol

authors

Bruinvis IA,Van Amstel A,Elevelt AJ,Van der Laarse R

doi

10.1088/0031-9155/28/6/007

subject

Has Abstract

pub_date

1983-06-01 00:00:00

pages

667-83

issue

6

eissn

0031-9155

issn

1361-6560

journal_volume

28

pub_type

杂志文章
  • SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

    abstract::A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/N01

    authors: Poludniowski G,Landry G,DeBlois F,Evans PM,Verhaegen F

    更新日期:2009-10-07 00:00:00

  • Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty.

    abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/15/003

    authors: Ploquin N,Song W,Lau H,Dunscombe P

    更新日期:2005-08-07 00:00:00

  • The relevance of very low energy ions for heavy-ion therapy.

    abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/7/N03

    authors: Elsässer T,Gemmel A,Scholz M,Schardt D,Krämer M

    更新日期:2009-04-07 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • Effects of body habitus on internal radiation dose calculations using the 5-year-old anthropomorphic male models.

    abstract::Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa75b4

    authors: Xie T,Kuster N,Zaidi H

    更新日期:2017-07-13 00:00:00

  • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.

    abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/308

    authors: Dance DR,Skinner CL,Young KC,Beckett JR,Kotre CJ

    更新日期:2000-11-01 00:00:00

  • Characterization of the secondary neutron field produced during treatment of an anthropomorphic phantom with x-rays, protons and carbon ions.

    abstract::Short- and long-term side effects following the treatment of cancer with radiation are strongly related to the amount of dose deposited to the healthy tissue surrounding the tumor. The characterization of the radiation field outside the planned target volume is the first step for estimating health risks, such as devel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/8/2111

    authors: Tessa CL,Berger T,Kaderka R,Schardt D,Burmeister S,Labrenz J,Reitz G,Durante M

    更新日期:2014-04-21 00:00:00

  • Modelling of temperature and perfusion during scalp cooling.

    abstract::Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/17/010

    authors: Janssen FE,Van Leeuwen GM,Van Steenhoven AA

    更新日期:2005-09-07 00:00:00

  • A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET.

    abstract::This paper presents a Fourier rebinning algorithm for three-dimensional image reconstruction in PET that incorporates the concept of spectral transfer function. It suggests the need for discarding low-frequency components in the rebinning. It also includes the correction for rebinning efficiency which was evaluated by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/004

    authors: Tanaka E,Amo Y

    更新日期:1998-04-01 00:00:00

  • Impact of high dose volumetric CT on PTV margin reduction in VMAT prostate radiotherapy.

    abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab050f

    authors: Cho YB,Alasti H,Kong V,Catton C,Berlin A,Chung P,Bayley A,Jaffray D

    更新日期:2019-03-14 00:00:00

  • Measurements of angular distributions of Rayleigh and Mie scattering events in biological models.

    abstract::Remission spectroscopy in living tissues can only be performed because scattering processes induce a pronounced amount of backscattered light. New types of scattering chambers were constructed in order to investigate the angular distribution of light intensities caused by scattering events typical for living tissues. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/12/012

    authors: Frank KH,Kessler M,Appelbaum K,Albrecht HP,Mauch ED

    更新日期:1989-12-01 00:00:00

  • On the correction, perturbation and modification of small field detectors in relative dosimetry.

    abstract::The purpose of this study was to derive a complete set of correction and perturbation factors for output factors (OF) and dose profiles. Modern small field detectors were investigated including a plastic scintillator (Exradin W1, SI), a liquid ionization chamber (microLion 31018, PTW), an unshielded diode (Exradin D1V...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5937

    authors: Papaconstadopoulos P,Tessier F,Seuntjens J

    更新日期:2014-10-07 00:00:00

  • The validation of tomotherapy dose calculations in low-density lung media.

    abstract::The dose-calculation accuracy of the tomotherapy Hi-Art II(R) (Tomotherapy, Inc., Madison, WI) treatment planning system (TPS) in the presence of low-density lung media was investigated. In this evaluation, a custom-designed heterogeneous phantom mimicking the mediastinum geometry was used. Gammex LN300 and balsa wood...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/004

    authors: Chaudhari SR,Pechenaya OL,Goddu SM,Mutic S,Rangaraj D,Bradley JD,Low D

    更新日期:2009-04-21 00:00:00

  • The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard.

    abstract::This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR (192)Ir brachytherapy sources. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/11/011

    authors: Bidmead AM,Sander T,Locks SM,Lee CD,Aird EG,Nutbrown RF,Flynn A,IPEM Working Party.

    更新日期:2010-06-07 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Dielectric characteristics of packed human erythrocytes with haemoglobins F, AA, AS and SS.

    abstract::The radiofrequency dielectric behaviour of packed human erythrocytes has been investigated in normal haemoglobins F and AA and also abnormal haemoglobins homozygous SS and heterozygous AS. Dielectric measurements were made in tightly packed blood cells at an average room temperature of 26.5 +/- 0.5 degrees C in the fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/4/002

    authors: Laogun AA,Ajayi NO,Okafor LO,Osamo NO

    更新日期:1983-04-01 00:00:00

  • First experimental evidence of the feasibility of multi-color magnetic particle imaging.

    abstract::Magnetic particle imaging is a new approach to visualizing magnetic nanoparticles. It is capable of 3D real-time in vivo imaging of particles injected into the blood stream and is a candidate for medical imaging applications. To date, only one particle type has been imaged at a time, however, the ability to separate s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/1775

    authors: Rahmer J,Halkola A,Gleich B,Schmale I,Borgert J

    更新日期:2015-03-07 00:00:00

  • Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

    abstract::Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/5/008

    authors: Martin CJ

    更新日期:1995-05-01 00:00:00

  • Rigid motion correction of dual opposed planar projections in single photon imaging.

    abstract::Awake and/or freely moving small animal single photon emission imaging allows the continuous study of molecules exhibiting slow kinetics without the need to restrain or anaesthetise the animals. Estimating motion free projections in freely moving small animal planar imaging can be considered as a limited angle tomogra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa68cd

    authors: Angelis GI,Ryder WJ,Gillam JE,Boisson F,Kyme AZ,Fulton RR,Meikle SR,Kench PL

    更新日期:2017-05-21 00:00:00

  • Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system.

    abstract::The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/N1

    authors: Yamamoto S,Watabe T,Watabe H,Aoki M,Sugiyama E,Imaizumi M,Kanai Y,Shimosegawa E,Hatazawa J

    更新日期:2012-01-21 00:00:00

  • Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors.

    abstract::Beam tracking with scanned carbon ion radiotherapy achieves highly conformal target dose by steering carbon pencil beams to follow moving tumors using real-time magnetic deflection and range modulation. The purpose of this study was to evaluate the robustness of target dose coverage from beam tracking in light of posi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1717

    authors: Eley JG,Newhauser WD,Richter D,Lüchtenborg R,Saito N,Bert C

    更新日期:2015-02-21 00:00:00

  • A rigid motion correction method for helical computed tomography (CT).

    abstract::We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/2047

    authors: Kim JH,Nuyts J,Kyme A,Kuncic Z,Fulton R

    更新日期:2015-03-07 00:00:00

  • Study of the PTW microLion chamber temperature dependence.

    abstract::The use of liquid ionization chambers in radiotherapy has grown during the past few years. While for air ionization chambers the k(TP) correction for air mass density due to pressure and temperature variations is well known, less work has been done on the case of liquid ionization chambers, where there is still the ne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2705

    authors: Gómez F,González-Castaño D,Díaz-Botana P,Pardo-Montero J

    更新日期:2014-06-07 00:00:00

  • Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour.

    abstract::In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, notice...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/003

    authors: Karampatzakis A,Samaras T

    更新日期:2010-10-07 00:00:00

  • The investigation of different cameras for in-beam PET imaging.

    abstract::In situ and in vivo treatment plan verification and beam monitoring as well as dose control during heavy-ion tumour therapy can be performed in principle by measurements of range distributions of beta(+)-emitting nuclei by means of PET techniques. For this purpose the performance of different types of positron camera ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/2/006

    authors: Pawelke J,Byars L,Enghardt W,Fromm WD,Geissel H,Hasch BG,Lauckner K,Manfrass P,Schardt D,Sobiella M

    更新日期:1996-02-01 00:00:00

  • Improving source detection and separation in a spatiotemporal Bayesian inference dipole analysis.

    abstract::Most existing spatiotemporal multi-dipole approaches for MEG/EEG source localization assume that the dipoles are active for the full time range being analysed. If the actual time range of activity of sources is significantly shorter than the time range being analysed, the detectability, localization and time-course de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/004

    authors: Jun SC,George JS,Plis SM,Ranken DM,Schmidt DM,Wood CC

    更新日期:2006-05-21 00:00:00

  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms.

    abstract::Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/012

    authors: Zacharatou Jarlskog C,Lee C,Bolch WE,Xu XG,Paganetti H

    更新日期:2008-02-07 00:00:00

  • FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines.

    abstract::This study investigated the relationship between the specific absorption rate and temperature elevation in an anatomically-based model named NORMAN for exposure to radio-frequency far fields in the ICNIRP guidelines (1998 Health Phys. 74 494-522). The finite-difference time-domain method is used for analyzing the elec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/020

    authors: Hirata A,Asano T,Fujiwara O

    更新日期:2007-08-21 00:00:00

  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00