A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET.

Abstract:

:This paper presents a Fourier rebinning algorithm for three-dimensional image reconstruction in PET that incorporates the concept of spectral transfer function. It suggests the need for discarding low-frequency components in the rebinning. It also includes the correction for rebinning efficiency which was evaluated by simulations as a function of oblique angle of projections. The performance was optimized by high-pass filters and axial smoothing. The algorithm yields satisfactory images with negligible axial cross-talk for a maximum oblique angle up to 26.6 degrees. The statistical noise was evaluated in terms of 'noise equivalent number of oblique angles', and reasonable results were obtained in view of the theoretical expectation. Ring artefacts due to noise are negligibly small.

journal_name

Phys Med Biol

authors

Tanaka E,Amo Y

doi

10.1088/0031-9155/43/4/004

subject

Has Abstract

pub_date

1998-04-01 00:00:00

pages

739-46

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

43

pub_type

杂志文章
  • Experimental characterization of two-dimensional pencil beam scanning proton spot profiles.

    abstract::Dose calculations of pencil beam scanning treatment plans rely on the accuracy of proton spot profiles; not only the primary component but also the broad tail components. Four films are placed at several locations in air and multiple depths in Solidwater® for six selected energies. The films used for the primary compo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/6193

    authors: Lin L,Ainsley CG,McDonough JE

    更新日期:2013-09-07 00:00:00

  • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy.

    abstract::The combined build-up and attenuation factor, B exp (-mu r), of point isotropic photon sources in a water medium has been calculated using the Monte Carlo method, for energies (20-1500 keV) and distances (1-10 cm) relevant in brachytherapy. For the transport of photons and electrons, up-to-date and self-consistent tot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/005

    authors: Angelopoulos A,Perris A,Sakellariou K,Sakelliou L,Sarigiannis K,Zarris G

    更新日期:1991-06-01 00:00:00

  • The feasibility of estimating and imaging the mechanical behavior of poroelastic materials using axial strain elastography.

    abstract::In this paper, we have investigated the feasibility of imaging the mechanical behavior of poroelastic materials using axial strain elastography. Cylindrical samples obtained from poroelastic materials having different elastic and permeability properties were subjected to a constant compression force (a classical creep...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/11/020

    authors: Righetti R,Righetti M,Ophir J,Krouskop TA

    更新日期:2007-06-07 00:00:00

  • A 3D point-kernel multiple scatter model for parallel-beam SPECT based on a gamma-ray buildup factor.

    abstract::A three-dimensional (3D) point-kernel multiple scatter model for point spread function (PSF) determination in parallel-beam single-photon emission computed tomography (SPECT), based on a dose gamma-ray buildup factor, is proposed. This model embraces nonuniform attenuation in a voxelized object of imaging (patient bod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/19/004

    authors: Marinkovic P,Ilic R,Spaic R

    更新日期:2007-10-07 00:00:00

  • W value measurements for protons in tissue-equivalent gas and its constituent gases.

    abstract::Values of W (the mean energy required to create an ion pair when a charged particle is stopped in a gas) are needed in radiation dosimetry to convert ionisation chamber current readings to absorbed dose. For neutron dosimetry the most important W values are those for protons, and this paper describes absolute measurem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/11/003

    authors: Thomas DJ,Burke M

    更新日期:1985-11-01 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Segmentation of dynamic PET images with kinetic spectral clustering.

    abstract::Segmentation is often required for the analysis of dynamic positron emission tomography (PET) images. However, noise and low spatial resolution make it a difficult task and several supervised and unsupervised methods have been proposed in the literature to perform the segmentation based on semi-automatic clustering of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/19/6931

    authors: Mouysset S,Zbib H,Stute S,Girault JM,Charara J,Noailles J,Chalon S,Buvat I,Tauber C

    更新日期:2013-10-07 00:00:00

  • Image quality improvements of electronic portal imaging devices by multi-level gain calibration and temperature correction.

    abstract::Amorphous silicon (aSi:H) flat panel detectors are prevalent in radiotherapy for megavoltage imaging tasks. Any clinical and dosimetrical application requires a well-defined dose response of the system to achieve meaningful results. Due to radiation damages, panels deteriorate and the linearity of pixel response to do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/18/6429

    authors: Huber S,Mooslechner M,Mitterlechner B,Weichenberger H,Serpa M,Sedlmayer F,Deutschmann H

    更新日期:2013-09-21 00:00:00

  • On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios.

    abstract::The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4412

    authors: Schmid G,Hirtl R

    更新日期:2016-06-21 00:00:00

  • Assessment of thermal effects in a model of the human head implanted with a wireless active microvalve for the treatment of glaucoma creating a filtering bleb.

    abstract::A 3D anatomical computational model is developed to assess thermal effects due to exposure to the electromagnetic field required to power a new investigational active implantable microvalve for the treatment of glaucoma. Such a device, located in the temporal superior eye quadrant, produces a filtering bleb, which is ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5dae

    authors: Schaumburg F,Guarnieri FA

    更新日期:2017-05-07 00:00:00

  • Regional compensation for statistical maximum likelihood reconstruction error of PET image pixels.

    abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/14/4849

    authors: Forma J,Niemi JA,Ruotsalainen U

    更新日期:2013-07-21 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

    abstract::Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/014

    authors: Kadrmas DJ,Frey EC,Karimi SS,Tsui BM

    更新日期:1998-04-01 00:00:00

  • Analysis of RF exposure in the head tissues of children and adults.

    abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/019

    authors: Wiart J,Hadjem A,Wong MF,Bloch I

    更新日期:2008-07-07 00:00:00

  • Neural networks-based regularization for large-scale medical image reconstruction.

    abstract::In this paper we present a generalized Deep Learning-based approach for solving ill-posed large-scale inverse problems occuring in medical image reconstruction. Recently, Deep Learning methods using iterative neural networks (NNs) and cascaded NNs have been reported to achieve state-of-the-art results with respect to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab990e

    authors: Kofler A,Haltmeier M,Schaeffter T,Kachelrieß M,Dewey M,Wald C,Kolbitsch C

    更新日期:2020-07-06 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • A method to reconstruct intra-fractional liver motion in rotational radiotherapy using linear fiducial markers.

    abstract::Complex intra-fractional motion and deformation of the liver significantly impacts the accuracy of delivered dose in radiotherapy. It limits margin reduction, dose escalation and normal tissue sparing. A critical component of motion management is to accurately reconstruct tumor motion. In this study, we developed a si...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4c0d

    authors: Chi Y,Shen C,Li B,Zhang Y,Yang M,Folkert M,Jia X

    更新日期:2019-11-21 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • Optimization and performance study of a proton CT system for pre-clinical small animal imaging.

    abstract::Proton computed tomography (pCT) promises to reduce or even eliminate range uncertainties inherent in the conversion of Hounsfield units into relative stopping power (RSP) for proton therapy treatment planning. This is of particular interest for proton irradiation studies in animal models due to the high precision req...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8afc

    authors: Meyer S,Bortfeldt J,Lämmer P,Englbrecht FS,Pinto M,Schnürle K,Würl M,Parodi K

    更新日期:2020-08-13 00:00:00

  • Transport calculations of depth-dose distributions for gadolinium neutron capture therapy.

    abstract::Depth-dose distributions were calculated for thermal and epithermal neutron fluence and capture gamma ray dose rates using a two-dimensional neutron-coupled gamma-ray transport code (DOT 3.5) for gadolinium neutron capture therapy. The results show that (i) a capture gamma-ray dose rate of 10 Gy h-1 was obtained with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/1/010

    authors: Matsumoto T

    更新日期:1992-01-01 00:00:00

  • A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field.

    abstract::Existing studies have suggested some debate on whether the quality of radiation that delivers dose outside of the primary field of a radiotherapy photon beam can be considered the same as that inside the primary field. We used a Monte Carlo approach to simulate the electron fluence differential in energy inside a wate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/015

    authors: Kirkby C,Field C,MacKenzie M,Syme A,Fallone BG

    更新日期:2007-06-21 00:00:00

  • Site-specific volumetric analysis of lung tumour motion.

    abstract::The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/005

    authors: Pepin EW,Wu H,Sandison GA,Langer M,Shirato H

    更新日期:2010-06-21 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • Evidence for a significant timer error on a linear accelerator: consequences for a special therapy application.

    abstract::A significant timer error has been found on a linear accelerator used for intraoperative radiation therapy. Since typical treatment doses range up to 20 Gy, calibrations that do not account for this effect can incur a large dosimetry error. The effect is dose rate dependent, but energy independent. For a dose rate of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/031

    authors: Biggs PJ

    更新日期:1998-10-01 00:00:00

  • Analytic treatment of resolution precision in electronically collimated SPECT imaging involving multiple-interaction gamma rays.

    abstract::The widely applied single-interaction analytic expression characterizing the energy resolution component of the angular resolution precision for an electronically collimated point source is extended to include multiple-interaction Compton scatter sequences as well as sequences terminated by photoelectric absorption. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/021

    authors: Durkee JW Jr,Antich PP,Tsyganov EN,Constantinescu A,Kulkarni PV,Smith BJ,Arbique GM,Lewis MA,Nguyen T,Raheja A,Thambi G,Parkey RW

    更新日期:1998-10-01 00:00:00

  • Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging.

    abstract::In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/615

    authors: van Gorp JS,Bakker CJ,Bouwman JG,Smink J,Zijlstra F,Seevinck PR

    更新日期:2015-01-21 00:00:00

  • Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound.

    abstract::Ultrasound may provide a quantitative technique for the characterization of cartilage changes typical of early osteoarthrosis. In this study, specific changes in bovine articular cartilage were induced using collagenase and chondroitinase ABC, enzymes that selectively degrade collagen fibril network and digest proteog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/303

    authors: Töyräs J,Rieppo J,Nieminen MT,Helminen HJ,Jurvelin JS

    更新日期:1999-11-01 00:00:00

  • Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams.

    abstract::The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three dimensional treatment planning system (Helax-TMS,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/302

    authors: Russell KR,Isacsson U,Saxner M,Ahnesjö A,Montelius A,Grusell E,Dahlgren CV,Lorin S,Glimelius B

    更新日期:2000-01-01 00:00:00

  • Influence of the physical state and straggling on the computation of the radiation dose due to radon daughters deposited in the lung.

    abstract::The effect of the physical state (phase) of the absorbing medium and the energy straggling of the alpha particles on the calculation of the radiation dose due to the daughter products of radon deposited in the lung have been studied in detail. The stopping power data for alpha particles in water and water vapour have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/8/004

    authors: Haque AK,Al-affan IA

    更新日期:1987-08-01 00:00:00