On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios.

Abstract:

:The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical modelling of the body was used at all, the skin was represented as a single homogeneous tissue layer. In the present paper we addressed the possible impacts of posture and skin modelling in scenarios of exposure to a 50 Hz uniform magnetic field on the in situ electric field strength in peripheral tissues, which must be limited in order to avoid peripheral nerve stimulation. We considered different body postures including situations where body parts form large induction loops (e.g. clasped hands) with skin-to-skin and skin-to-metal contact spots and compared the results obtained with a homogeneous single-layer skin model to results obtained with a more realistic two-layer skin representation consisting of a low-conductivity stratum corneum layer on top of a combined layer for the cellular epidermis and dermis. Our results clearly indicated that postures with loops formed of body parts may lead to substantially higher maximum values of induced in situ electric field strengths than in the case of standard postures due to a highly concentrated current density and in situ electric field strength in the skin-to-skin and skin-to-metal contact regions. With a homogeneous single-layer skin, as is used for even the most recent anatomical body models in exposure assessment, the in situ electric field strength may exceed the basic restrictions in such situations, even when the reference levels and maximum permissible exposure values are not exceeded. However, when using the more realistic two-layer skin model the obtained in situ electric field strengths were substantially lower and no violations of the basic restrictions occurred, which can be explained by the current-limiting effect of the low-conductivity stratum corneum layer.

journal_name

Phys Med Biol

authors

Schmid G,Hirtl R

doi

10.1088/0031-9155/61/12/4412

subject

Has Abstract

pub_date

2016-06-21 00:00:00

pages

4412-37

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

61

pub_type

杂志文章
  • Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue.

    abstract::A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa94b6

    authors: McClatchy DM,Rizzo EJ,Meganck J,Kempner J,Vicory J,Wells WA,Paulsen KD,Pogue BW

    更新日期:2017-11-10 00:00:00

  • Wavelet compression in medical terahertz pulsed imaging.

    abstract::This paper concerns the robustness of discrete wavelet transform (DWT) compression in terahertz pulsed imaging (TPI). TPI datasets consist of terahertz time-domain series which are sampled at each 'pixel' of the image, leading to file sizes which are typically of the order of several megabytes (MB) per image. This mak...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/328

    authors: Handley JW,Fitzgerald AJ,Berry E,Boyle RD

    更新日期:2002-11-07 00:00:00

  • Impedance magnetocardiogram.

    abstract::We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart--the so-called magnetocardiogram (MCG)--can be simultaneously detected by using this system. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/403

    authors: Kandori A,Miyashita T,Suzuki D,Yokosawa K,Tsukada K

    更新日期:2001-02-01 00:00:00

  • Construction of a biomechanical head and neck motion model as a guide to evaluation of deformable image registration.

    abstract::The use of deformable image registration methods in the context of adaptive radiotherapy leads to uncertainties in the simulation of the administered dose distributions during the treatment course. Evaluation of these methods is a prerequisite to decide if a plan adaptation will improve the individual treatment. Curre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa69b6

    authors: Teske H,Bartelheimer K,Meis J,Bendl R,Stoiber EM,Giske K

    更新日期:2017-06-21 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • An image reconstruction method with a locally adaptive gating scheme for PET data.

    abstract::In conventional gating approaches for positron emission tomography (PET), a single number of gates is predetermined for the whole field of view (FOV) regardless of spatially variant motion blurring effects, which compromises image quality by under-gating regions of large motion and over-gating static regions. To achie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac71b

    authors: Wang J,Dong Y,Li H,Feng T

    更新日期:2018-08-10 00:00:00

  • Characterization of optical parameters with a human forearm at the region from 1.15 to 1.52 microm using diffuse reflectance measurements.

    abstract::Time- and space-resolved diffuse reflectance measurements were used to identify the optical parameters, the reduced scattering and absorption coefficients, of bulk living tissue in the region from 1.15 to 1.52 microm. Although in this region the detector was limited in its temporal resolution, we applied a peak-time s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/11/021

    authors: Nishimura G,Kida I,Tamura M

    更新日期:2006-06-07 00:00:00

  • Simulation of small-angle x-ray scattering from collagen fibrils and comparison with experimental patterns.

    abstract::Simulation of small-angle x-ray scattering from collagen in healthy and cancerous breast tissue may reveal detailed information on the structural changes in collagen. Collagen fibril is modelled as a cylinder with axially periodic step-function electron density, and packing is approximated by placing the cylinders in ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/012

    authors: Suhonen H,Fernández M,Serimaa R,Suortti P

    更新日期:2005-11-21 00:00:00

  • On the total system error of a robotic radiosurgery system: phantom measurements, clinical evaluation and long-term analysis.

    abstract::The total system error (TSE) of a CyberKnife® system was measured using two phantom-based methods and one patient-based method. The standard radiochromic film (RCF) end-to-end (E2E) test using an anthropomorphic head and neck phantom and isocentric treatment delivery was used with the 6Dskull, Fiducial and Xsight® spi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad516

    authors: Pantelis E,Moutsatsos A,Antypas C,Zoros E,Pantelakos P,Lekas L,Romanelli P,Zourari K,Hourdakis CJ

    更新日期:2018-08-20 00:00:00

  • In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique.

    abstract::Respiratory research with mice using micro-computed tomography (micro-CT) has been predominantly hindered by the limited resolution and signal-to-noise ratio (SNR) as a result of respiratory motion artefacts. In this study, we develop a novel technique for capturing the lung microstructure in vivo using micro-CT, thro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/008

    authors: Namati E,Chon D,Thiesse J,Hoffman EA,de Ryk J,Ross A,McLennan G

    更新日期:2006-12-07 00:00:00

  • Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantom.

    abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/018

    authors: Hotta K,Kohno R,Takada Y,Hara Y,Tansho R,Himukai T,Kameoka S,Matsuura T,Nishio T,Ogino T

    更新日期:2010-06-21 00:00:00

  • A further assessment of an electromagnetic method to measure body composition.

    abstract::Two experimental investigations of the electromagnetic method to measure body composition are presented. In the first experiment, the impedance of a single-loop transmitting antenna, located at the centre of a 150 m helical receiving coil, was observed to have a sharp minimum at 2.40 MHz. The impedance of the antenna ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/011

    authors: Sutcliffe JF,Smye SW,Smith MA

    更新日期:1995-04-01 00:00:00

  • Evaluation of transmission methodology and attenuation correction for the microPET Focus 220 animal scanner.

    abstract::An accurate, low noise estimate of photon attenuation in the subject is required for quantitative microPET studies of molecular tracer distributions in vivo. In this work, several transmission-based measurement techniques were compared, including coincidence mode with and without rod windowing, singles mode with two d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/008

    authors: Lehnert W,Meikle SR,Siegel S,Newport D,Banati RB,Rosenfeld AB

    更新日期:2006-08-21 00:00:00

  • Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

    abstract::A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/12/006

    authors: Meissner P,Jacob M,Rassow J

    更新日期:1988-12-01 00:00:00

  • Dosimetric characteristics of electron beams produced by a mobile accelerator for IORT.

    abstract::Energy and angular distributions of electron beams with different energies were simulated by Monte Carlo calculations. These beams were generated by the NOVAC7 system (Hitesys, Italy), a mobile electron accelerator specifically dedicated to intra-operative radiation therapy (IORT). The electron beam simulations were v...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/008

    authors: Pimpinella M,Mihailescu D,Guerra AS,Laitano RF

    更新日期:2007-10-21 00:00:00

  • Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts.

    abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/003

    authors: Hurkmans C,Knöös T,Nilsson P

    更新日期:1996-08-01 00:00:00

  • Concentrations of Fe, Cu and Zn in breast tissue: a synchrotron XRF study.

    abstract::An x-ray fluorescence system with a synchrotron radiation source was used to quantify the levels of iron, copper and zinc in breast tissue specimens. Healthy tissue and breast carcinomas were investigated as an aid to understanding the mechanisms of breast cancer and as a possible complementary diagnostic tool. Eighty...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/13/310

    authors: Geraki K,Farquharson MJ,Bradley DA

    更新日期:2002-07-07 00:00:00

  • Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media.

    abstract::A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/11/301

    authors: Chetty IJ,Moran JM,Nurushev TS,McShan DL,Fraass BA,Wilderman SJ,Bielajew AF

    更新日期:2002-06-07 00:00:00

  • Spinal pedicle screw planning using deformable atlas registration.

    abstract::Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device sele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5f42

    authors: Goerres J,Uneri A,De Silva T,Ketcha M,Reaungamornrat S,Jacobson M,Vogt S,Kleinszig G,Osgood G,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-07 00:00:00

  • Design and performance of the micro-dose calibrator.

    abstract::A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT) module prototype built to evaluate its performance. The design of the micro-dose calibrator is based on the con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadb3b

    authors: Adler S,Choyke P

    更新日期:2018-09-10 00:00:00

  • X-ray beam filtration, dosimetry phantom size and CT patient dose conversion factors.

    abstract::We examine how the choice of CT x-ray beam filtration and phantom size influences patient dose (D) to computed tomography dose index (CTDI) conversion factors (i.e. D/CTDI). The ratio of head to body phantom CTDI(w) for a defined scan technique is alpha, and the ratio of organ dose when the body filter is changed to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/2/014

    authors: Huda W,Sterzik A,Tipnis S

    更新日期:2010-01-21 00:00:00

  • Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films.

    abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8bf3

    authors: Kawashima M,Matsumura A,Souda H,Tashiro M

    更新日期:2020-06-15 00:00:00

  • Tetrazolium salts-Pluronic F-127 gels for 3D radiotherapy dosimetry.

    abstract::This work is a follow-up study for a recently-proposed 3D radiochromic gel dosimeter that contains a tetrazolium salt and a physical gel matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127). Several tetrazolium salts were examined in this work, including tetrazoli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabbb6

    authors: Kwiatos K,Maras P,Kadlubowski S,Stempień Z,Dudek M,Kozicki M

    更新日期:2018-05-04 00:00:00

  • On the surviving fraction in irradiated multicellular tumour spheroids: calculation of overall radiosensitivity parameters, influence of hypoxia and volume effects.

    abstract::We model the heterogeneous response to radiation of multicellular tumour spheroids assuming position- and volume-dependent radiosensitivity. We propose a method to calculate the overall radiosensitivity parameters to obtain the surviving fraction of tumours. A mathematical model of a spherical tumour with a hypoxic co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/005

    authors: Horas JA,Olguin OR,Rizzotto MG

    更新日期:2005-04-21 00:00:00

  • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.

    abstract::Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/N02

    authors: Klüter S,Sroka-Perez G,Schubert K,Debus J

    更新日期:2011-01-21 00:00:00

  • Automated cell cycle analysis with fluorescence microscopy and image analysis.

    abstract::Automatic cell cycle analysis (DNA histograms) is usually performed with flow cytometry. In cases when only few cells are available, the DNA content has to be measured with a fluorescence microscope combined with sensitive camera systems (SIT, MCP, cooled CCDs) and a frame grabber for image analysis. The fluorescent c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/3/013

    authors: Böcker W,Gantenberg HW,Müller WU,Streffer C

    更新日期:1996-03-01 00:00:00

  • The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging.

    abstract::Diffusion weighted magnetic resonance imaging offers a non-invasive tool to explore the three-dimensional structure of brain white matter in clinical practice. Anisotropic diffusion hardware phantoms are useful for the quantitative validation of this technique. This study provides guidelines on how to manufacture anis...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/009

    authors: Fieremans E,De Deene Y,Delputte S,Ozdemir MS,Achten E,Lemahieu I

    更新日期:2008-10-07 00:00:00

  • Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil.

    abstract::Heating induced near deep brain stimulation (DBS) lead electrodes during magnetic resonance imaging with a 3 T transceive head coil was measured, modeled, and imaged in three cadaveric porcine heads (mean body weight = 85.47 ± 3.19 kg, mean head weight = 5.78 ± 0.32 kg). The effect of the placement of the extra-crania...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5651

    authors: Shrivastava D,Abosch A,Hughes J,Goerke U,DelaBarre L,Visaria R,Harel N,Vaughan JT

    更新日期:2012-09-07 00:00:00

  • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence.

    abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/022

    authors: Taylor ML,Franich RD,Johnston PN,Millar RM,Trapp JV

    更新日期:2007-07-07 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00