Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

Abstract:

:A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the photodiode the infrared emission of the planchet and the TLD-detector produced a high output signal above about 200 degrees C. In addition to this background signal an infrared emission from the TLD-300 detectors could be detected. This infrared TL-signal exhibited the same dose dependences as the visible signal, but the amplitude was higher than that of the visible TL-signal. For the applied photodiode the ratio of the infrared TL-signal to the visible TL-signal was about 24 for the 100 degrees C peak, about 15 for the 150 degrees C peak and 6 for the 240 degrees C peak.

journal_name

Phys Med Biol

authors

Meissner P,Jacob M,Rassow J

doi

10.1088/0031-9155/33/12/006

subject

Has Abstract

pub_date

1988-12-01 00:00:00

pages

1407-15

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

33

pub_type

杂志文章
  • Experimental validation of Monte Carlo calculations with a voxelized Rando-Alderson phantom: a study on influence parameters.

    abstract::The development and improvement of techniques for an accurate dose assessment in medical physics is an important task. In this study, we focus on the validation of Monte Carlo calculations, by comparing organ doses assessed experimentally with thermoluminescent detectors in the Rando-Alderson phantom with doses calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/20/018

    authors: Struelens L,Vanhavere F,Smans K

    更新日期:2008-10-21 00:00:00

  • In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    abstract::The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1596

    authors: Balidemaj E,de Boer P,van Lier AL,Remis RF,Stalpers LJ,Westerveld GH,Nederveen AJ,van den Berg CA,Crezee J

    更新日期:2016-02-21 00:00:00

  • Single-shot K-edge subtraction x-ray discrete computed tomography with a polychromatic source and the Pixie-III detector.

    abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7105

    authors: Brun F,Di Trapani V,Albers J,Sacco P,Dreossi D,Brombal L,Rigon L,Longo R,Mittone A,Dullin C,Bravin A,Delogu P

    更新日期:2020-03-06 00:00:00

  • Coverage-based constraints for IMRT optimization.

    abstract::Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8132

    authors: Mescher H,Ulrich S,Bangert M

    更新日期:2017-09-05 00:00:00

  • Derivation of mean dose tolerances for new fractionation schemes and treatment modalities.

    abstract::Avoiding toxicities in radiotherapy requires the knowledge of tolerable organ doses. For new, experimental fractionation schemes (e.g. hypofractionation) these are typically derived from traditional schedules using the biologically effective dose (BED) model. In this report we investigate the difficulties of establish...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9836

    authors: Perkó Z,Bortfeld T,Hong T,Wolfgang J,Unkelbach J

    更新日期:2018-02-05 00:00:00

  • Three-dimensional optical tomography of the premature infant brain.

    abstract::For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/23/303

    authors: Hebden JC,Gibson A,Yusof RM,Everdell N,Hillman EM,Delpy DT,Arridge SR,Austin T,Meek JH,Wyatt JS

    更新日期:2002-12-07 00:00:00

  • A beam profile generation algorithm for wedged half-beam blocked asymmetric fields.

    abstract::A method is presented to predict beam profiles and outputs for wedged asymmetric fields defined by independent collimator jaws allowing fast generation of beam profiles whilst requiring very little additional data to that already used by most treatment planning systems in generating symmetric field isodoses. Symmetric...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/004

    authors: Millin AE,Smith CW

    更新日期:1994-01-01 00:00:00

  • Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system.

    abstract::To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/9/307

    authors: Liu HL,Chen YY,Yen JY,Lin WL

    更新日期:2003-05-07 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00

  • A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation.

    abstract::The purpose of this study was to evaluate the impact of numerical errors caused by the floating point representation of real numbers in a GPU-based Monte Carlo code used for dose calculation in radiation oncology, and to identify situations where this type of error arises. The program used as a benchmark was bGPUMCD. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5007

    authors: Magnoux V,Ozell B,Bonenfant É,Després P

    更新日期:2015-07-07 00:00:00

  • Glandular dose in breast computed tomography with synchrotron radiation.

    abstract::The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/569

    authors: Mettivier G,Fedon C,Di Lillo F,Longo R,Sarno A,Tromba G,Russo P

    更新日期:2016-01-21 00:00:00

  • Hybrid scatter correction applied to quantitative holmium-166 SPECT.

    abstract::Ho-166 is a combined beta-gamma emitter of which the betas can be used therapeutically. From the 81 keV gammas of Ho-166, SPECT images can be obtained, which give opportunities to guide Ho-166 therapy. Accurate reconstruction of Ho-166 images is currently hampered by photopeak-scatter in the patient, down-scatter in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/004

    authors: de Wit TC,Xiao J,Nijsen JF,van het Schip FD,Staelens SG,van Rijk PP,Beekman FJ

    更新日期:2006-10-07 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • Stopping cross-sections of various gases for alpha particles in the energy region 0.2 to 5.5 MeV.

    abstract::A single experimental apparatus has been designed to allow measurements of stopping cross-sections of materials in liquid and vapour phase, for alpha particles, using an indirect method. The method, in which residual energies for increasing absorber thicknesses are obtained and differentiated, has been used in a numbe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/5/004

    authors: Thwaites DI

    更新日期:1980-09-01 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • T1 and extracellular volume fraction mapping in cardiac magnetic resonance: estimation of accuracy and precision of a novel algorithm.

    abstract::Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also est...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcca

    authors: Borrazzo C,Pacilio M,Galea N,Preziosi E,Carnì M,Francone M,Catalano C,Carbone I

    更新日期:2019-02-11 00:00:00

  • Brachytherapy technology and physics practice since 1950: a half-century of progress.

    abstract::The 50-year tenure of Physics in Medicine and Biology has coincided with some of the most important developments in radiological science, including the introduction of artificial radioactivity, computers and 3D imaging into medicine. These events have profoundly influenced the development of brachytherapy. Although it...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R18

    authors: Williamson JF

    更新日期:2006-07-07 00:00:00

  • Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

    abstract::Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/947

    authors: Cao Q,Thawait G,Gang GJ,Zbijewski W,Reigel T,Brown T,Corner B,Demehri S,Siewerdsen JH

    更新日期:2015-02-07 00:00:00

  • High-energy radiation monitoring based on radio-fluorogenic co-polymerization. I: Small volume in situ probe.

    abstract::A method of radiation dosimetry is described which is based on the radiation-induced initiation of polymerization of a bulk monomer (e.g. methyl methacrylate) containing a small concentration (about 100 ppm) of a compound which is non-fluorescent but which becomes highly fluorescent when it is incorporated into a grow...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/015

    authors: Warman JM,de Haas MP,Luthjens LH

    更新日期:2009-05-21 00:00:00

  • Monte Carlo simulations of a nozzle for the treatment of ocular tumours with high-energy proton beams.

    abstract::By the end of 2002, 33 398 patients worldwide had been treated with proton radiotherapy, 10 829 for eye diseases. The dose prediction algorithms used today for ocular proton therapy treatment planning rely on parameterizations of measured proton dose distributions, i.e., broad-beam and pencil-beam techniques, whose pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/002

    authors: Newhauser W,Koch N,Hummel S,Ziegler M,Titt U

    更新日期:2005-11-21 00:00:00

  • Optimization of magnetic flux density measurement using multiple RF receiver coils and multi-echo in MREIT.

    abstract::Magnetic Resonance Electrical Impedance Tomography (MREIT) is an MRI method that enables mapping of internal conductivity and/or current density via measurements of magnetic flux density signals. The MREIT measures only the z-component of the induced magnetic flux density B = (Bx, By, Bz) by external current injection...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4827

    authors: Jeong WC,Chauhan M,Sajib SZ,Kim HJ,Serša I,Kwon OI,Woo EJ

    更新日期:2014-09-07 00:00:00

  • Coupled radiative transfer equation and diffusion approximation model for photon migration in turbid medium with low-scattering and non-scattering regions.

    abstract::In this paper, a coupled radiative transfer equation and diffusion approximation model is extended for light propagation in turbid medium with low-scattering and non-scattering regions. The light propagation is modelled with the radiative transfer equation in sub-domains in which the assumptions of the diffusion appro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/011

    authors: Tarvainen T,Vauhkonen M,Kolehmainen V,Arridge SR,Kaipio JP

    更新日期:2005-10-21 00:00:00

  • Investigating the robustness of ion beam therapy treatment plans to uncertainties in biological treatment parameters.

    abstract::Uncertainties in determining clinically used relative biological effectiveness (RBE) values for ion beam therapy carry the risk of absolute and relative misestimations of RBE-weighted doses for clinical scenarios. This study assesses the consequences of hypothetical misestimations of input parameters to the RBE modell...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/7983

    authors: Böhlen TT,Brons S,Dosanjh M,Ferrari A,Fossati P,Haberer T,Patera V,Mairani A

    更新日期:2012-12-07 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • The ArcCHECK diode array for dosimetric verification of HybridArc.

    abstract::The aim of this work is to evaluate dosimetric accuracy of a new treatment modality, HybridArc, in iPlan RT Dose 4.5 (BrainLAB, Feldkirchen, Germany) using a four-dimensional diode array (ArcCHECK, Sun Nuclear Corporation, Melbourne, USA). HybridArc is able to enhance dynamic conformal arcs with inversely planned elem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/16/021

    authors: Petoukhova AL,van Egmond J,Eenink MG,Wiggenraad RG,van Santvoort JP

    更新日期:2011-08-21 00:00:00

  • Assessment of noise in a digital image using the join-count statistic and the Moran test.

    abstract::We assume that the data bits of a pixel in digital images can be divided into signal and noise bits. The signal bits occupy the most significant part of the pixel and the noise bits the least significant part. The signal part of each pixel are correlated while the noise parts are uncorrelated. Two statistical methods,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/2/004

    authors: Chuang KS,Huang HK

    更新日期:1992-02-01 00:00:00

  • Fast calculation of 3D radiofrequency ablation zone based on a closed-form solution of heat conduction equation fitted by ex vivo measurements.

    abstract::Fast calculation or simulation of the ablation zone induced by radiofrequency ablation (RFA) has a critical role in hepatic RFA planning and therapy. However, it remains challenging to approximate the ablation zone in real time, especially when more than one probe is involved in one ablation session. This paper presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe052

    authors: Chen R,Zhang J,Kong D,Lou Q,Lu F

    更新日期:2021-01-27 00:00:00

  • Dual-head gamma camera system for intraoperative localization of radioactive seeds.

    abstract::Breast-conserving surgery is a standard option for the treatment of patients with early-stage breast cancer. This form of surgery may result in incomplete excision of the tumor. Iodine-125 labeled titanium seeds are currently used in clinical practice to reduce the number of incomplete excisions. It seems likely that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7655

    authors: Arsenali B,de Jong HW,Viergever MA,Dickerscheid DB,Beijst C,Gilhuijs KG

    更新日期:2015-10-07 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

    abstract::Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a4b

    authors: Chen B,Zhang Z,Sidky EY,Xia D,Pan X

    更新日期:2017-11-02 00:00:00