Dual-head gamma camera system for intraoperative localization of radioactive seeds.

Abstract:

:Breast-conserving surgery is a standard option for the treatment of patients with early-stage breast cancer. This form of surgery may result in incomplete excision of the tumor. Iodine-125 labeled titanium seeds are currently used in clinical practice to reduce the number of incomplete excisions. It seems likely that the number of incomplete excisions can be reduced even further if intraoperative information about the location of the radioactive seed is combined with preoperative information about the extent of the tumor. This can be combined if the location of the radioactive seed is established in a world coordinate system that can be linked to the (preoperative) image coordinate system. With this in mind, we propose a radioactive seed localization system which is composed of two static ceiling-suspended gamma camera heads and two parallel-hole collimators. Physical experiments and computer simulations which mimic realistic clinical situations were performed to estimate the localization accuracy (defined as trueness and precision) of the proposed system with respect to collimator-source distance (ranging between 50 cm and 100 cm) and imaging time (ranging between 1 s and 10 s). The goal of the study was to determine whether or not a trueness of 5 mm can be achieved if a collimator-source distance of 50 cm and imaging time of 5 s are used (these specifications were defined by a group of dedicated breast cancer surgeons). The results from the experiments indicate that the location of the radioactive seed can be established with an accuracy of 1.6 mm  ±  0.6 mm if a collimator-source distance of 50 cm and imaging time of 5 s are used (these experiments were performed with a 4.5 cm thick block phantom). Furthermore, the results from the simulations indicate that a trueness of 3.2 mm or less can be achieved if a collimator-source distance of 50 cm and imaging time of 5 s are used (this trueness was achieved for all 14 breast phantoms which were used in this study). Based on these results we conclude that the proposed system can be a valuable tool for (real-time) intraoperative breast cancer localization.

journal_name

Phys Med Biol

authors

Arsenali B,de Jong HW,Viergever MA,Dickerscheid DB,Beijst C,Gilhuijs KG

doi

10.1088/0031-9155/60/19/7655

subject

Has Abstract

pub_date

2015-10-07 00:00:00

pages

7655-70

issue

19

eissn

0031-9155

issn

1361-6560

journal_volume

60

pub_type

杂志文章
  • Dose evaluation of boron neutron capture synovectomy using the THOR epithermal neutron beam: a feasibility study.

    abstract::Rheumatoid arthritis is one of the most common epidemic diseases in the world. For some patients, the treatment with steroids or nonsteroidal anti-inflammatory drugs is not effective, thus necessitating physical removal of the inflamed synovium. Alternative approaches other than surgery will provide appropriate diseas...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/6/014

    authors: Wu J,Chang SJ,Chuang KS,Hsueh YW,Yeh KC,Wang JN,Tsai WP

    更新日期:2007-03-21 00:00:00

  • Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging.

    abstract::In this study, we explore the potential of compressed sensing (CS) accelerated broadband 3D phase-encoded turbo spin-echo (3D-PE-TSE) for the purpose of geometrically undistorted imaging in the presence of field inhomogeneities. To achieve this goal 3D-PE-SE and 3D-PE-TSE sequences with broadband rf pulses and dedicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/615

    authors: van Gorp JS,Bakker CJ,Bouwman JG,Smink J,Zijlstra F,Seevinck PR

    更新日期:2015-01-21 00:00:00

  • Dosimetric consequences of tumour motion due to respiration for a scanned proton beam.

    abstract::A method for simulating spot-scanned delivery to a moving tumour was developed which uses patient-specific image and plan data. The magnitude of interplay effects was investigated for two patient cases under different fractionation and respiratory motion variation scenarios. The use of volumetric rescanning for motion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/20/003

    authors: Kraus KM,Heath E,Oelfke U

    更新日期:2011-10-21 00:00:00

  • A study of the impact of x-ray tube performance on angiography system imaging efficiency.

    abstract::This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abbb7a

    authors: Dehairs M,Bosmans H,Marshall NW

    更新日期:2020-11-24 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.

    abstract::In critical organ in vivo x-ray dosimetry, the relative contaminating electron contribution to the total dose and total detector response outside the field will be different to the corresponding contributions at the central axis detector calibration position, mainly due to the effects of shielding in the linear accele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/24/013

    authors: Edwards CR,Mountford PJ,Moloney AJ

    更新日期:2006-12-21 00:00:00

  • In vivo evaluation of a new system for 3D computerized angiography.

    abstract::A new system has been designed and built to validate the concept of 3D computerized angiography (CA). This system can acquire a set of 2D digital subtracted angiography images while rotating around a patient and then, using these images, reconstruct a 3D representation of the opacified vasculature. The design principl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/3/020

    authors: Saint-Félix D,Trousset Y,Picard C,Ponchut C,Roméas R,Rougée A

    更新日期:1994-03-01 00:00:00

  • The exponential edge-gradient effect in x-ray computed tomography.

    abstract::The exponential edge-gradient effect must arise in any x-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of x-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/010

    authors: Joseph PM,Spital RD

    更新日期:1981-05-01 00:00:00

  • Modelling of temperature and perfusion during scalp cooling.

    abstract::Hair loss is a feared side effect of chemotherapy treatment. It may be prevented by cooling the scalp during administration of cytostatics. The supposed mechanism is that by cooling the scalp, both temperature and perfusion are diminished, affecting drug supply and drug uptake in the hair follicle. However, the effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/17/010

    authors: Janssen FE,Van Leeuwen GM,Van Steenhoven AA

    更新日期:2005-09-07 00:00:00

  • An automatic method for determining the centre of rotation of a mechanically scanned reflection UCT system.

    abstract::A method will be described for determining the centre of rotation of a mechanically scanned reflection ultrasound computed tomography system. It is based on the principle of obtaining opposing images of a test object containing many point targets. The method is automatic in the sense that the centre of rotation is cal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/12/017

    authors: Jago JR

    更新日期:1994-12-01 00:00:00

  • Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations.

    abstract::A Monte Carlo model of a novel electronic portal imaging device (EPID) has been developed using Geant4 and its performance for imaging and dosimetry applications in radiotherapy has been characterised. The EPID geometry is based on a physical prototype under ongoing investigation and comprises an array of plastic scin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6827

    authors: Blake SJ,McNamara AL,Vial P,Holloway L,Kuncic Z

    更新日期:2014-11-21 00:00:00

  • An extended diffraction-enhanced imaging method for implementing multiple-image radiography.

    abstract::Diffraction-enhanced imaging (DEI) is an analyser-based x-ray imaging method that produces separate images depicting the projected x-ray absorption and refractive properties of an object. Because the imaging model of DEI does not account for ultra-small-angle x-ray scattering (USAXS), the images produced in DEI can co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/011

    authors: Chou CY,Anastasio MA,Brankov JG,Wernick MN,Brey EM,Connor DM,Zhong Z

    更新日期:2007-04-07 00:00:00

  • Iterative volume morphing and learning for mobile tumor based on 4DCT.

    abstract::During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa56b2

    authors: Mao S,Wu H,Sandison G,Fang S

    更新日期:2017-02-21 00:00:00

  • Simulated lesion, human observer performance comparison between thin-section dedicated breast CT images versus computed thick-section simulated projection images of the breast.

    abstract::The objective of this study was to compare the lesion detection performance of human observers between thin-section computed tomography images of the breast, with thick-section (>40 mm) simulated projection images of the breast. Three radiologists and six physicists each executed a two alterative force choice (2AFC) s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3347

    authors: Chen L,Boone JM,Abbey CK,Hargreaves J,Bateni C,Lindfors KK,Yang K,Nosratieh A,Hernandez A,Gazi P

    更新日期:2015-04-21 00:00:00

  • A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer.

    abstract::The aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture opt...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0031-9155/52/8/007

    authors: Kim Y,Verhey LJ,Xia P

    更新日期:2007-04-21 00:00:00

  • Anatomically-aided PET reconstruction using the kernel method.

    abstract::This paper extends the kernel method that was proposed previously for dynamic PET reconstruction, to incorporate anatomical side information into the PET reconstruction model. In contrast to existing methods that incorporate anatomical information using a penalized likelihood framework, the proposed method incorporate...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6668

    authors: Hutchcroft W,Wang G,Chen KT,Catana C,Qi J

    更新日期:2016-09-21 00:00:00

  • An in vivo method of measurement of the mechanical properties of vascular prostheses: the mechanical properties of saphenous vein bypass grafts.

    abstract::It seems likely that long term patency of small bore vascular prostheses is dependent upon, among other things, the mechanical properties of their walls. Arteries are visco-elastic but there is no accurate method of measuring the visco-elasticity of arterial substitutes in vivo. The most successful vascular substitute...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/9/006

    authors: Chapman BL,Charlesworth D

    更新日期:1983-09-01 00:00:00

  • Terahertz near-field imaging.

    abstract::A near-field probe is described that enables high spatial resolution imaging with terahertz (THz) pulses. The spatial resolution capabilities of the system lie in the range of few microns and we demonstrate a resolution of 7 microm using broad-banded THz pulses with an intensity maximum near 0.5 THz. We present a stud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/308

    authors: Federici JF,Mitrofanov O,Lee M,Hsu JW,Brener I,Harel R,Wynn JD,Pfeiffer LN,West KW

    更新日期:2002-11-07 00:00:00

  • An efficient strategy based on an individualized selection of registration methods. Application to the coregistration of MR and SPECT images in neuro-oncology.

    abstract::An efficient registration strategy is described that aims to help solve delicate medical imaging registration problems. It consists of running several registration methods for each dataset and selecting the best one for each specific dataset, according to an evaluation criterion. Finally, the quality of the registrati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6997

    authors: Tacchella JM,Roullot E,Lefort M,Cohen ME,Guillevin R,Petrirena G,Delattre JY,Habert MO,Yeni N,Kas A,Frouin F

    更新日期:2014-11-21 00:00:00

  • Fully three-dimensional positron emission tomography.

    abstract::Fully three-dimensional positron emission tomography is considered and a reconstruction algorithm derived. The reconstruction problem is formulated mathematically as a three-dimensional convolution integral of a point spread function with an unknown positron activity distribution and is solved by Fourier transform met...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/010

    authors: Colsher JG

    更新日期:1980-01-01 00:00:00

  • An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

    abstract::To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novik...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/018

    authors: Tang Q,Zeng GL,Huang Q

    更新日期:2006-12-07 00:00:00

  • Bayesian multiresolution method for local tomography in dental x-ray imaging.

    abstract::Dental tomographic cone-beam x-ray imaging devices record truncated projections and reconstruct a region of interest (ROI) inside the head. Image reconstruction from the resulting local tomography data is an ill-posed inverse problem. A new Bayesian multiresolution method is proposed for local tomography reconstructio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/22/008

    authors: Niinimäki K,Siltanen S,Kolehmainen V

    更新日期:2007-11-21 00:00:00

  • Review on the characteristics of radiation detectors for dosimetry and imaging.

    abstract::The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/20/R303

    authors: Seco J,Clasie B,Partridge M

    更新日期:2014-10-21 00:00:00

  • Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies.

    abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/10/007

    authors: Houston AS,Elliott AT,Stone DL

    更新日期:1982-10-01 00:00:00

  • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

    abstract::A 4D ordered-subsets maximum a posteriori (OSMAP) algorithm for dynamic SPECT is described which uses a temporal prior that constrains each voxel's behaviour in time to conform to a compartmental model. No a priori limitations on kinetic parameters are applied; rather, the parameter estimates evolve as the algorithm i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/5/315

    authors: Kadrmas DJ,Gullberg GT

    更新日期:2001-05-01 00:00:00

  • T1 and extracellular volume fraction mapping in cardiac magnetic resonance: estimation of accuracy and precision of a novel algorithm.

    abstract::Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also est...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcca

    authors: Borrazzo C,Pacilio M,Galea N,Preziosi E,Carnì M,Francone M,Catalano C,Carbone I

    更新日期:2019-02-11 00:00:00

  • An iodine-125 thyroid measurement method.

    abstract::A two-probe technique has been developed to measure 125I in the thyroid. In this technique simultaneous emissions from a source are detected as coincidence events between two probes rather than as a sum peak in a single probe (the sum peak method). The background count rate when counting coincidence events between pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/3/004

    authors: Burns PA,Peggie JR

    更新日期:1980-05-01 00:00:00

  • Effect of fiducial marker localization on stereotactic target coordinate calculation in CT slices and radiographs.

    abstract::Novel methods are presented which allow the estimation of the effect of stereotactic fiducial marker localization on target localization in a stereotactic surgery planning program based on the integration of image data from various modalities. The results of simulations are presented. A method for the evaluation of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/11/008

    authors: Lemieux L,Jagoe R

    更新日期:1994-11-01 00:00:00

  • An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

    abstract::Radiation dose calculation using models of the human anatomy has been a subject of great interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers of this field did not foresee the exponential growth of research activity as observed today. This review article walks the reader through...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/18/R233

    authors: Xu XG

    更新日期:2014-09-21 00:00:00

  • Verification of the super-omni wedge concept.

    abstract::This study verifies the concept of the super-omni wedge by validating its equations for effective wedge orientation and wedge angle and by comparing the dose distributions it produces with those produced by other wedge techniques. To validate the equations, we calculated dose distributions for 20 combinations of wedge...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/9/313

    authors: Dai J,Zhu Y,Wu X

    更新日期:2001-09-01 00:00:00