An automatic method for determining the centre of rotation of a mechanically scanned reflection UCT system.

Abstract:

:A method will be described for determining the centre of rotation of a mechanically scanned reflection ultrasound computed tomography system. It is based on the principle of obtaining opposing images of a test object containing many point targets. The method is automatic in the sense that the centre of rotation is calculated by a computer without the need for an operator to make direct measurements on the mechanical system. For the particular reflection UCT system described here, the centre of rotation is obtained in 3-5 min with a repeatability (+/-2 SD) of +/-0.3 mm. Ways in which even higher accuracy can be obtained are discussed. The basic principle of the method is applicable to any concentric imaging system for which a good approximation to an ideal point target can be produced.

journal_name

Phys Med Biol

authors

Jago JR

doi

10.1088/0031-9155/39/12/017

subject

Has Abstract

pub_date

1994-12-01 00:00:00

pages

2367-71

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

39

pub_type

杂志文章
  • Modelling infrared temperature measurements: implications for laser irradiation and cryogen cooling studies.

    abstract::The use of thermographic techniques has increased as infrared detector technology has evolved and improved. For laser-tissue interactions, thermal cameras have been used to monitor the thermal response of tissue to pulsed and continuous wave irradiation. It is important to note that the temperature indicated by the th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/319

    authors: Choi B,Pearce JA,Welch AJ

    更新日期:2000-02-01 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • A feasibility study of the use of fluorescence bronchoscopy for localization of small lung tumours.

    abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/014

    authors: Profio AE,Doiron DR

    更新日期:1977-09-01 00:00:00

  • Towards a gold standard for quantitative coronary arteriography.

    abstract::Densitometric quantification of coronary artery stenoses in angiographic images can be problematic for two reasons: (i) the x-rays are inadequately oriented with respect to the vessel segments of interest at image acquisition; (ii) non-linear effects due for instance to beam hardening, scattered radiation and veiling ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/12/011

    authors: Doriot PA,Dorsaz PA,Dorsaz L,Bodenmann JJ

    更新日期:1997-12-01 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Temperature simulations in tissue with a realistic computer generated vessel network.

    abstract::The practical use of a discrete vessel thermal model for hyperthermia treatment planning requires a number of choices with respect to the unknown part of the patient's vasculature. This work presents a study of the thermal effects of blood flow in a simple tissue geometry with a detailed artificial vessel network. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/317

    authors: Van Leeuwen GM,Kotte AN,Raaymakers BW,Lagendijk JJ

    更新日期:2000-04-01 00:00:00

  • Optimization of a depth of interaction encoding PET block detector for a PET/MRI insert.

    abstract::Preclinical positron emission tomography, combined with magnetic resonance imaging (PET/MRI), is increasingly used as a tool to simultaneously characterize functional processes in vivo. Many emerging preclinical applications, however, are limited by PET detection sensitivity, especially when generating short imaging f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaef59

    authors: Selfridge AR,Cherry SR,Judenhofer MS

    更新日期:2018-12-06 00:00:00

  • Implementation of biologically conformal radiation therapy (BCRT) in an algorithmic segmentation-based inverse planning approach.

    abstract::The development of new biological imaging technologies offers the opportunity to further individualize radiotherapy. Biologically conformal radiation therapy (BCRT) implies the use of the spatial distribution of one or more radiobiological parameters to guide the IMRT dose prescription. Our aim was to implement BCRT i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/N02

    authors: Vanderstraeten B,De Gersem W,Duthoy W,De Neve W,Thierens H

    更新日期:2006-08-21 00:00:00

  • 3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture.

    abstract::The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human experti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab039b

    authors: Nguyen D,Jia X,Sher D,Lin MH,Iqbal Z,Liu H,Jiang S

    更新日期:2019-03-18 00:00:00

  • Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study.

    abstract::The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/021

    authors: Deeley MA,Chen A,Datteri R,Noble JH,Cmelak AJ,Donnelly EF,Malcolm AW,Moretti L,Jaboin J,Niermann K,Yang ES,Yu DS,Yei F,Koyama T,Ding GX,Dawant BM

    更新日期:2011-07-21 00:00:00

  • A potential method for in vivo range verification in proton therapy treatment.

    abstract::Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respira...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/5/016

    authors: Lu HM

    更新日期:2008-03-07 00:00:00

  • Filtered back-projection reconstruction for attenuation proton CT along most likely paths.

    abstract::This work investigates the attenuation of a proton beam to reconstruct the map of the linear attenuation coefficient of a material which is mainly caused by the inelastic interactions of protons with matter. Attenuation proton computed tomography (pCT) suffers from a poor spatial resolution due to multiple Coulomb sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/3258

    authors: Quiñones CT,Létang JM,Rit S

    更新日期:2016-05-07 00:00:00

  • A double-tuned (1)H/(23)Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI.

    abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/019

    authors: Wetterling F,Tabbert M,Junge S,Gallagher L,Macrae IM,Fagan AJ

    更新日期:2010-12-21 00:00:00

  • Female pelvic synthetic CT generation based on joint intensity and shape analysis.

    abstract::Using MRI for radiotherapy treatment planning and image guidance is appealing as it provides superior soft tissue information over CT scans and avoids possible systematic errors introduced by aligning MR to CT images. This study presents a method that generates Synthetic CT (MRCT) volumes by performing probabilistic t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/8/2935

    authors: Liu L,Jolly S,Cao Y,Vineberg K,Fessler JA,Balter JM

    更新日期:2017-04-21 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • Effects of f-number on the histotripsy intrinsic threshold and cavitation bubble cloud behavior.

    abstract::Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Although previous work has provided significant insight into the process of intrinsic threshold histotripsy, the majority of these studies have used highly focused (i.e. f-number  <  0.6...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa54c7

    authors: Vlaisavljevich E,Gerhardson T,Hall T,Xu Z

    更新日期:2017-02-21 00:00:00

  • Effect of temperature on the optical properties of ex vivo human dermis and subdermis.

    abstract::The effect of temperature on the optical properties of human dermis and subdermis as a function of near-infrared wavelength has been studied between 25 degrees C and 40 degrees C. Measurements were performed ex vivo on a total of nine skin samples taken from the abdomen of three individuals. The results show a reprodu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/9/004

    authors: Laufer J,Simpson R,Kohl M,Essenpreis M,Cope M

    更新日期:1998-09-01 00:00:00

  • Radiofrequency and microwave dielectric properties of aqueous cryoprotectant agents: dimethyl sulphoxide and 2,3-butanediol.

    abstract::Earlier work on the dielectric properties of cryoprotectant agents is extended using a modified measuring cell and method of data reduction yielding results more efficiently over a temperature range from -75 to +25 degrees C at frequencies from 27 MHz to 3 GHz. Dimethyl sulphoxide and butanediol are investigated at lo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/011

    authors: Evans S,bin Azeman A

    更新日期:1998-10-01 00:00:00

  • Comparison of SAR and induced current densities in adults and children exposed to electromagnetic fields from electronic article surveillance devices.

    abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/009

    authors: Martínez-Búrdalo M,Sanchis A,Martín A,Villar R

    更新日期:2010-02-21 00:00:00

  • Quantitative analysis of bony birth canal for periacetabular osteotomy patient by template fitting.

    abstract::Periacetabular osteotomy (PAO) is a joint preservation procedure for developmental dysplasia of the hip. Such a procedure requires osteotomy of the medial wall of the acetabulum, which may cause the narrow of the bony birth canal and increase the risk of complications during the childbirth process in the future. Using...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abcb22

    authors: Shao L,Li H,Liu X,Wang Y,Shi L,Ai D,Fan J,Song H,Zhang H,Yang J

    更新日期:2021-01-22 00:00:00

  • Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    abstract::For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron stor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8231

    authors: Buhr H,Büermann L,Gerlach M,Krumrey M,Rabus H

    更新日期:2012-12-21 00:00:00

  • Monte Carlo dosimetric study of the BEBIG Co-60 HDR source.

    abstract::Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterlo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/N03

    authors: Ballester F,Granero D,Pérez-Calatayud J,Casal E,Agramunt S,Cases R

    更新日期:2005-11-07 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • The energy response of a T.P.A. Mk-II ionization chamber using GEANT4 Monte Carlo simulation.

    abstract::The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The sample position resulting in the maximum response along the axial direction of the chamber was obtained. The parameters of the simulation wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/012

    authors: Seneviratne MD,Reinhard MI,Baldock C

    更新日期:2007-07-07 00:00:00

  • Tradeoffs of integrating real-time tracking into IGRT for prostate cancer treatment.

    abstract::This study investigated the integration of the Calypso real-time tracking system, based on implanted ferromagnetic transponders and a detector array, into the current process for image-guided radiation treatment (IGRT) of prostate cancer at our institution. The current IGRT process includes magnetic resonance imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/N03

    authors: Zhu X,Bourland JD,Yuan Y,Zhuang T,O'Daniel J,Thongphiew D,Wu QJ,Das SK,Yoo S,Yin FF

    更新日期:2009-09-07 00:00:00

  • Site-specific volumetric analysis of lung tumour motion.

    abstract::The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/005

    authors: Pepin EW,Wu H,Sandison GA,Langer M,Shirato H

    更新日期:2010-06-21 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • Automated detection of spinal centrelines, vertebral bodies and intervertebral discs in CT and MR images of lumbar spine.

    abstract::We propose a completely automated algorithm for the detection of the spinal centreline and the centres of vertebral bodies and intervertebral discs in images acquired by computed tomography (CT) and magnetic resonance (MR) imaging. The developed methods are based on the analysis of the geometry of spinal structures an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/015

    authors: Stern D,Likar B,Pernus F,Vrtovec T

    更新日期:2010-01-07 00:00:00

  • A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

    abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/010

    authors: Tong S,Alessio AM,Kinahan PE,Liu H,Shi P

    更新日期:2011-04-21 00:00:00