An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Abstract:

:To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novikov-type algorithm. The new algorithm is able to compensate for uniform attenuation, and computer simulation results show that reconstructed images are less noisy.

journal_name

Phys Med Biol

authors

Tang Q,Zeng GL,Huang Q

doi

10.1088/0031-9155/51/23/018

subject

Has Abstract

pub_date

2006-12-07 00:00:00

pages

6199-211

issue

23

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)28994-2

journal_volume

51

pub_type

杂志文章
  • The fast Padé transform in magnetic resonance spectroscopy for potential improvements in early cancer diagnostics.

    abstract::The convergence rates of the fast Padé transform (FPT) and the fast Fourier transform (FFT) are compared. These two estimators are used to process a time-signal encoded at 4 T by means of one-dimensional magnetic resonance spectroscopy (MRS) for healthy human brain. It is found systematically that at any level of trun...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/010

    authors: Belkić D,Belkić K

    更新日期:2005-09-21 00:00:00

  • Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty.

    abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/15/003

    authors: Ploquin N,Song W,Lau H,Dunscombe P

    更新日期:2005-08-07 00:00:00

  • Quantitative evaluation of regularized phase retrieval algorithms on bone scaffolds seeded with bone cells.

    abstract::In the field of regenerative medicine, there has been a growing interest in studying the combination of bone scaffolds and cells that can maximize newly formed bone. In-line phase-contrast x-ray tomography was used to image porous bone scaffolds (Skelite(©)), seeded with bone forming cells. This technique allows the q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/N215

    authors: Weber L,Langer M,Tavella S,Ruggiu A,Peyrin F

    更新日期:2016-05-07 00:00:00

  • Comparison of large-area position-sensitive solid-state photomultipliers for small animal PET.

    abstract::This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SS...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8119

    authors: Schmall JP,Du J,Yang Y,Dokhale PA,McClish M,Christian J,Shah KS,Cherry SR

    更新日期:2012-12-21 00:00:00

  • Comparison of two respiration monitoring systems for 4D imaging with a Siemens CT using a new dynamic breathing phantom.

    abstract::Four-dimensional computed tomography (4D-CT) requires breathing information from the patient, and for this, several systems are available. Testing of these systems, under realistic conditions, requires a phantom with a moving target and an expandable outer contour. An anthropomorphic phantom was developed to simulate ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/N131

    authors: Vásquez AC,Runz A,Echner G,Sroka-Perez G,Karger CP

    更新日期:2012-05-07 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • On MEG forward modelling using multipolar expansions.

    abstract::Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/4/301

    authors: Jerbi K,Mosher JC,Baillet S,Leahy RM

    更新日期:2002-02-21 00:00:00

  • Correction-less dosimetry of nonstandard photon fields: a new criterion to determine the usability of radiation detectors.

    abstract::In the IAEA-AAPM dosimetry formalism, detector measurements in general nonstandard conditions are corrected using the factor k(f(clin),f(msr))(Q(clin),Q(msr)). This factor needs to be evaluated on a case-by-case basis which is difficult to accomplish in practice. The present paper aims to provide a method that allows ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4973

    authors: Kamio Y,Bouchard H

    更新日期:2014-09-07 00:00:00

  • Fundamental study on diffuse reflective optical tomography.

    abstract::We report a simulation study on diffuse reflective optical computed tomography, in which continuous-wave sources and detectors are placed on the plane surface of a semi-infinite body. We adopted a simple Tikhonov regularization in the inverse problem and demonstrated the feasibility of three-dimensional reconstruction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/10/004

    authors: Endoh R,Suzuki A,Fujii M,Nakayama K

    更新日期:2004-05-21 00:00:00

  • Patch-based anisotropic diffusion scheme for fluorescence diffuse optical tomography--part 2: image reconstruction.

    abstract::Fluorescence diffuse optical tomography (fDOT) provides 3D images of fluorescence distributions in biological tissue, which represent molecular and cellular processes. The image reconstruction problem is highly ill-posed and requires regularisation techniques to stabilise and find meaningful solutions. Quadratic regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1452

    authors: Correia T,Koch M,Ale A,Ntziachristos V,Arridge S

    更新日期:2016-02-21 00:00:00

  • Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    abstract::Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/003

    authors: Qian M,Niu L,Wang Y,Jiang B,Jin Q,Jiang C,Zheng H

    更新日期:2010-10-21 00:00:00

  • Effect of fiducial marker localization on stereotactic target coordinate calculation in CT slices and radiographs.

    abstract::Novel methods are presented which allow the estimation of the effect of stereotactic fiducial marker localization on target localization in a stereotactic surgery planning program based on the integration of image data from various modalities. The results of simulations are presented. A method for the evaluation of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/11/008

    authors: Lemieux L,Jagoe R

    更新日期:1994-11-01 00:00:00

  • A spectral approach to ultrasonic scattering from human tissue: methods, objectives and backscattering measurements.

    abstract::The dearth of information on the physical processes involved in the propagation of ultrasound in tissue and the growing need for such information are discussed. The physical nature of the ultrasonic diagnostic process in considered in terms of a wave phenomenon and the limitations and advantages of frequency spectral ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/5/009

    authors: Chivers RC,Hill CR

    更新日期:1975-09-01 00:00:00

  • Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    abstract::In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/542

    authors: Hou X,Tanguay J,Buckley K,Schaffer P,Bénard F,Ruth TJ,Celler A

    更新日期:2016-01-21 00:00:00

  • The utilization of consistency metrics for error analysis in deformable image registration.

    abstract::The aim of this study was to investigate the utility of consistency metrics, such as inverse consistency, in contour-based deformable registration error analysis. Four images were acquired of the same phantom that has experienced varying levels of deformation. The deformations were simulated with deformable image regi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/18/014

    authors: Bender ET,Tomé WA

    更新日期:2009-09-21 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Biological dose representation for carbon-ion radiotherapy of unconventional fractionation.

    abstract::In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been common practice for efficient operation, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. Treatments are usually fractionated and treatment plans are ev...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/3/1062

    authors: Kanematsu N,Inaniwa T

    更新日期:2017-02-07 00:00:00

  • A facility for in vivo measurement of kidney and liver cadmium by neutron capture prompt gamma ray analysis.

    abstract::An in vivo method for the determination of Cd levels in human kidney and liver has been developed. The method allows detection of absolute quantities of Cd in the left kidney and Cd concentration in the liver. The limit of detection of cadmium is 2.5 mg for the left kidney and 1.8 microgram/g (wet weight) for the live...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/6/003

    authors: Vartsky D,Ellis KJ,Chen NS,Cohn SH

    更新日期:1977-11-01 00:00:00

  • Threshold-driven optimization for reference-based auto-planning.

    abstract::We study threshold-driven optimization methodology for automatically generating a treatment plan that is motivated by a reference DVH for IMRT treatment planning. We present a framework for threshold-driven optimization for reference-based auto-planning (TORA). Commonly used voxel-based quadratic penalties have two co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa731

    authors: Long T,Chen M,Jiang S,Lu W

    更新日期:2018-02-08 00:00:00

  • Dose measurements near a non-radioactive gold seed using radiographic film.

    abstract::The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as inte...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/18/N02

    authors: Chow JC,Grigorov GN

    更新日期:2005-09-21 00:00:00

  • A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopes.

    abstract::Recent developments in the technique of constant infusion and in emission computed tomography have provided a new method for quantitative regional flow measurements. This paper re-examines critically the theoretical relationship between flow and radioactivity during constant infusion of short-lived isotopes. Sensitivi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/6/005

    authors: Huang SC,Phelps ME,Hoffman EJ,Kuhl DE

    更新日期:1979-11-01 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

    abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6635

    authors: Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

    更新日期:2016-09-21 00:00:00

  • In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique.

    abstract::Respiratory research with mice using micro-computed tomography (micro-CT) has been predominantly hindered by the limited resolution and signal-to-noise ratio (SNR) as a result of respiratory motion artefacts. In this study, we develop a novel technique for capturing the lung microstructure in vivo using micro-CT, thro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/008

    authors: Namati E,Chon D,Thiesse J,Hoffman EA,de Ryk J,Ross A,McLennan G

    更新日期:2006-12-07 00:00:00

  • Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

    abstract::In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/21/8567

    authors: Bruder H,Raupach R,Sunnegardh J,Allmendinger T,Klotz E,Stierstorfer K,Flohr T

    更新日期:2015-11-07 00:00:00

  • MTF evaluation of a phosphor-coated CCD for x-ray imaging.

    abstract::A novel digital x-ray detector has been assembled. The imaging system is based on a phosphor-coated charge-coupled device (CCD) obtained by direct deposition of a gadolinium oxysulphide scintillator onto the detector surface. The modulation transfer function has been measured along the two directions of the digital co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/12/016

    authors: Gambaccini M,Taibi A,Del Guerra A,Marziani M,Tuffanelli A

    更新日期:1996-12-01 00:00:00

  • Influence of anisotropic compartments on magnetic field and electric potential distributions generated by artificial current dipoles inside a torso phantom.

    abstract::The purpose of this study is the analysis of the influence of anisotropic conductivity on magnetic fields and electric potentials by means of phantom measurements. An artificial rotating current dipole was placed in the middle of an anisotropic skein arrangement in a torso phantom filled with saline solution. The sign...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/017

    authors: Liehr M,Haueisen J

    更新日期:2008-01-07 00:00:00

  • Clinical ultraviolet dosimetry with a CCD monochromator array spectroradiometer.

    abstract::Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/026

    authors: Coleman A,Sarkany R,Walker S

    更新日期:2008-09-21 00:00:00

  • Directional x-ray dark-field imaging.

    abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/004

    authors: Jensen TH,Bech M,Bunk O,Donath T,David C,Feidenhans'l R,Pfeiffer F

    更新日期:2010-06-21 00:00:00