Novel iterative reconstruction method with optimal dose usage for partially redundant CT-acquisition.

Abstract:

:In CT imaging, a variety of applications exist which are strongly SNR limited. However, in some cases redundant data of the same body region provide additional quanta. Examples in dual energy CT, the spatial resolution has to be compromised to provide good SNR for material decomposition. However, the respective spectral dataset of the same body region provides additional quanta which might be utilized to improve SNR of each spectral component. Perfusion CT is a high dose application, and dose reduction is highly desirable. However, a meaningful evaluation of perfusion parameters might be impaired by noisy time frames. On the other hand, the SNR of the average of all time frames is extremely high.In redundant CT acquisitions, multiple image datasets can be reconstructed and averaged to composite image data. These composite image data, however, might be compromised with respect to contrast resolution and/or spatial resolution and/or temporal resolution. These observations bring us to the idea of transferring high SNR of composite image data to low SNR 'source' image data, while maintaining their resolution.It has been shown that the noise characteristics of CT image data can be improved by iterative reconstruction (Popescu et al 2012 Book of Abstracts, 2nd CT Meeting (Salt Lake City, UT) p 148). In case of data dependent Gaussian noise it can be modelled with image-based iterative reconstruction at least in an approximate manner (Bruder et al 2011 Proc. SPIE 7961 79610J). We present a generalized update equation in image space, consisting of a linear combination of the previous update, a correction term which is constrained by the source image data, and a regularization prior, which is initialized by the composite image data. This iterative reconstruction approach we call bimodal reconstruction (BMR). Based on simulation data it is shown that BMR can improve low contrast detectability, substantially reduces the noise power and has the potential to recover spatial resolution of the source image data.For different CT applications: dual energy imaging, liver imaging, spiral imaging, cardiac imaging, we show that SNR can efficiently be transferred from the composite image to the source image data at constant patient dose, while maintaining resolution properties of the source data.

journal_name

Phys Med Biol

authors

Bruder H,Raupach R,Sunnegardh J,Allmendinger T,Klotz E,Stierstorfer K,Flohr T

doi

10.1088/0031-9155/60/21/8567

subject

Has Abstract

pub_date

2015-11-07 00:00:00

pages

8567-82

issue

21

eissn

0031-9155

issn

1361-6560

journal_volume

60

pub_type

杂志文章
  • Development of an MR-compatible gamma probe for combined MR/RI guided surgery.

    abstract::We have developed and tested an MR-compatible gamma probe to simultaneously obtain anatomical information and functional information during surgery. The probe consists of a probe head, an optical fibre bundle and a photo-multiplier tube (PMT). The NaI(T1) scintillator contained in the probe head is connected to a 7 m ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/15/005

    authors: Yamamoto S,Kuroda K,Senda M

    更新日期:2004-08-07 00:00:00

  • Influence of anisotropic compartments on magnetic field and electric potential distributions generated by artificial current dipoles inside a torso phantom.

    abstract::The purpose of this study is the analysis of the influence of anisotropic conductivity on magnetic fields and electric potentials by means of phantom measurements. An artificial rotating current dipole was placed in the middle of an anisotropic skein arrangement in a torso phantom filled with saline solution. The sign...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/017

    authors: Liehr M,Haueisen J

    更新日期:2008-01-07 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00

  • Curvature correction of retinal OCTs using graph-based geometry detection.

    abstract::In this paper, we present a new algorithm as an enhancement and preprocessing step for acquired optical coherence tomography (OCT) images of the retina. The proposed method is composed of two steps, first of which is a denoising algorithm with wavelet diffusion based on a circular symmetric Laplacian model, and the se...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2925

    authors: Kafieh R,Rabbani H,Abramoff MD,Sonka M

    更新日期:2013-05-07 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

    abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4635

    authors: Nemallapudi MV,Gundacker S,Lecoq P,Auffray E,Ferri A,Gola A,Piemonte C

    更新日期:2015-06-21 00:00:00

  • Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach.

    abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab17f9

    authors: Hofmann T,Fochi A,Parodi K,Pinto M

    更新日期:2019-05-21 00:00:00

  • Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction.

    abstract::Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadc88

    authors: Uzunov NM,Melendez-Alafort L,Bello M,Cicoria G,Zagni F,De Nardo L,Selva A,Mou L,Rossi-Alvarez C,Pupillo G,Di Domenico G,Uccelli L,Boschi A,Groppi F,Salvini A,Taibi A,Duatti A,Martini P,Pasquali M,Loriggiola M,Mare

    更新日期:2018-09-19 00:00:00

  • Experimental pencil beam kernels derivation for 3D dose calculation in flattening filter free modulated fields.

    abstract::This paper presents a method to obtain the pencil-beam kernels that characterize a megavoltage photon beam generated in a flattening filter free (FFF) linear accelerator (linac) by deconvolution from experimental measurements at different depths. The formalism is applied to perform independent dose calculations in mod...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/50

    authors: Azcona JD,Barbés B,Wang L,Burguete J

    更新日期:2016-01-07 00:00:00

  • Assessment of induced radio-frequency electromagnetic fields in various anatomical human body models.

    abstract::The reference levels for testing compliance of human exposure with radio-frequency (RF) safety limits have been derived from very simplified models of the human. In order to validate these findings for anatomical models, we investigated the absorption characteristics for various anatomies ranging from 6 year old child...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/004

    authors: Kühn S,Jennings W,Christ A,Kuster N

    更新日期:2009-02-21 00:00:00

  • Monte Carlo modelling of electron beams from medical accelerators.

    abstract::Monte Carlo simulation of radiation transport is considered to be one of the most accurate methods of radiation therapy dose calculation. With the rapid development of computer technology, Monte Carlo based treatment planning for radiation therapy is becoming practical. A basic requirement for Monte Carlo treatment pl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/12/201

    authors: Ma CM,Jiang SB

    更新日期:1999-12-01 00:00:00

  • Monitoring the irradiation field of 12C and 16O SOBP beams using positron emitters produced through projectile fragmentation reactions.

    abstract::In order to effectively utilize the prominent properties of heavy ions in radiotherapy, it is important to evaluate both the position of the field irradiated with incident ions and the absorbed dose distribution in a patient's body. One of the methods for this purpose is the utilization of the positron emitters produc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/002

    authors: Inaniwa T,Kohno T,Tomitani T,Sato S

    更新日期:2008-02-07 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • A mathematical model of the biologically effective dose of solar UVA received by patients undergoing oral psoralen photochemotherapy for psoriasis.

    abstract::A theoretical analysis is presented of the biologically effective dose of the solar long wave ultraviolet radiation (UVA) received by patients who are being treated for psoriasis by oral psoralen photochemotherapy. It is shown that patients treated during the summer months in the UK may well receive a UV dose which is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/6/011

    authors: Diffey BL

    更新日期:1981-11-01 00:00:00

  • Mapping initial and general recombination in scanning proton pencil beams.

    abstract::The ion recombination is examined in parallel-plate ionization chambers in scanning proton beams at the Danish Centre for Particle Therapy and the Skandion Clinic. The recombination correction factor k s is investigated for clinically relevant energies between 70 MeV and 244 MeV for dose rates below 400 Gy min-1 in ai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8579

    authors: Christensen JB,Almhagen E,Stolarczyk L,Liszka M,Hernandez GG,Bassler N,Nørrevang O,Vestergaard A

    更新日期:2020-06-05 00:00:00

  • Monte Carlo dosimetric study of the BEBIG Co-60 HDR source.

    abstract::Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterlo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/N03

    authors: Ballester F,Granero D,Pérez-Calatayud J,Casal E,Agramunt S,Cases R

    更新日期:2005-11-07 00:00:00

  • An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery.

    abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8534

    authors: Capaldi DPI,Skinner LB,Dubrowski P,Yu AS

    更新日期:2020-06-10 00:00:00

  • Locally linear constraint based optimization model for material decomposition.

    abstract::Dual spectral computed tomography (DSCT) has a superior material distinguishability than the conventional single spectral computed tomography (SSCT). However, the decomposition process is an illposed problem, which is sensitive to noise. Thus, the decomposed image quality is degraded, and the corresponding signal-to-n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8e13

    authors: Wang Q,Zhu Y,Yu H

    更新日期:2017-10-19 00:00:00

  • The recombination correction for an ionisation chamber exposed to pulsed radiation in a 'swept beam' technique. I. Theory.

    abstract::The established theory for the collection efficiency of an ionisation chamber irradiated by a series of uniform short pulses is extended to the more complex case of irradiation in a pulsed and electromagnetically swept electron beam. The radial variation of exposure rate is assumed to be Gaussian with scale constant e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/2/001

    authors: Boag JW

    更新日期:1982-02-01 00:00:00

  • Deep learning-based radiomic features for improving neoadjuvant chemoradiation response prediction in locally advanced rectal cancer.

    abstract::Radiomic features achieve promising results in cancer diagnosis, treatment response prediction, and survival prediction. Our goal is to compare the handcrafted (explicitly designed) and deep learning (DL)-based radiomic features extracted from pre-treatment diffusion-weighted magnetic resonance images (DWIs) for predi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7970

    authors: Fu J,Zhong X,Li N,Van Dams R,Lewis J,Sung K,Raldow AC,Jin J,Qi XS

    更新日期:2020-04-02 00:00:00

  • A feasibility study of the use of fluorescence bronchoscopy for localization of small lung tumours.

    abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/014

    authors: Profio AE,Doiron DR

    更新日期:1977-09-01 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Effective dose conversion coefficient for gamma ray exposure from an overhead plume.

    abstract::The external radiation exposure from an overhead plume containing gamma emitting radionuclides can contribute substantial dose to the ground receptor during normal operations as well as accidental release conditions of nuclear facilities. In order to estimate the effective dose conversion coefficients (DCCs) directly,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2c92

    authors: Dey R,Patni HK,Deo Singh K,Kulkarni MS,Anand S

    更新日期:2019-08-01 00:00:00

  • Distributed three-dimensional simulation of B-mode ultrasound imaging using a first-order k-space method.

    abstract::Computational modeling is an important tool in ultrasound imaging research, but realistic three-dimensional (3D) simulations can exceed the capabilities of serial computers. This paper uses a 3D simulator based on a k-space method that incorporates relaxation absorption and nonreflecting boundary conditions. The simul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/007

    authors: Daoud MI,Lacefield JC

    更新日期:2009-09-07 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • Motion induced interplay effects for VMAT radiotherapy.

    abstract::The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab957

    authors: Edvardsson A,Nordström F,Ceberg C,Ceberg S

    更新日期:2018-04-19 00:00:00

  • Measuring the imaged-object distance with a stationary high-spatial-resolution scintillation camera.

    abstract::A method to measure the detector-to-object distance from the images obtained with stationary high-spatial-resolution gamma-ray cameras for in vivo studies has been developed. It exploits the shift of the imaged object in the image plane, obtained at a certain tilt of the parallel-hole collimator. A linear dependence o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/9/N04

    authors: Uzunov N,Bello M,Boccaccio P,Moschini G,Bollini D,de Notaristefani F

    更新日期:2006-05-07 00:00:00

  • Laser speckle imaging of blood flow in microcirculation.

    abstract::Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scannin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/020

    authors: Cheng H,Luo Q,Liu Q,Lu Q,Gong H,Zeng S

    更新日期:2004-04-07 00:00:00

  • A novel linear programming approach to fluence map optimization for intensity modulated radiation therapy treatment planning.

    abstract::We present a novel linear programming (LP) based approach for efficiently solving the intensity modulated radiation therapy (IMRT) fluence-map optimization (FMO) problem to global optimality. Our model overcomes the apparent limitations of a linear-programming approach by approximating any convex objective function by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/21/005

    authors: Romeijn HE,Ahuja RK,Dempsey JF,Kumar A,Li JG

    更新日期:2003-11-07 00:00:00

  • Monte Carlo and water calorimetric determination of kilovoltage beam radiotherapy ionization chamber correction factors.

    abstract::The in-phantom calibration method for radiotherapy kilovoltage x-ray beams requires ionization chamber correction factors. The overall ionization chamber correction factor accounts for changes in the chamber response due to the displacement of water by the chamber cavity and wall, the presence of the stem and the chan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab82e7

    authors: Bancheri J,Ketelhut S,Büermann L,Seuntjens J

    更新日期:2020-05-11 00:00:00