Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach.

Abstract:

:Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the positron emitter activity profile is not directly proportional to the dose distribution, until today only its comparison to a prediction of the PET profile allows for treatment verification. Usually, this prediction is obtained from time-consuming Monte Carlo simulations of high computational effort, which impacts the clinical workflow. To solve this issue in proton therapy, a convolution approach was suggested to predict positron emitter activity profiles from depth dose distributions analytically. In this work, we introduce an approach to predict positron emitter distributions from depth dose profiles in carbon ion therapy. While the distal fall-off position of the positron emitter profile is predicted from a convolution approach similar to the one suggested for protons, additional analytical functions are introduced to describe the characteristics of the positron emitter distribution in tissue. The feasibility of this approach is demonstrated with monoenergetic depth dose profiles and spread out Bragg peaks in homogeneous and heterogeneous phantoms. In all cases, the positron emitter profile is predicted with high precision and the distal fall-off position is reproduced with millimeter accuracy.

journal_name

Phys Med Biol

authors

Hofmann T,Fochi A,Parodi K,Pinto M

doi

10.1088/1361-6560/ab17f9

subject

Has Abstract

pub_date

2019-05-21 00:00:00

pages

105022

issue

10

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    abstract::The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1596

    authors: Balidemaj E,de Boer P,van Lier AL,Remis RF,Stalpers LJ,Westerveld GH,Nederveen AJ,van den Berg CA,Crezee J

    更新日期:2016-02-21 00:00:00

  • Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

    abstract::Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2441

    authors: Ding A,Mille MM,Liu T,Caracappa PF,Xu XG

    更新日期:2012-05-07 00:00:00

  • On the surviving fraction in irradiated multicellular tumour spheroids: calculation of overall radiosensitivity parameters, influence of hypoxia and volume effects.

    abstract::We model the heterogeneous response to radiation of multicellular tumour spheroids assuming position- and volume-dependent radiosensitivity. We propose a method to calculate the overall radiosensitivity parameters to obtain the surviving fraction of tumours. A mathematical model of a spherical tumour with a hypoxic co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/005

    authors: Horas JA,Olguin OR,Rizzotto MG

    更新日期:2005-04-21 00:00:00

  • Markerless positional verification using template matching and triangulation of kV images acquired during irradiation for lung tumors treated in breath-hold.

    abstract::Lung tumors treated in breath-hold are subject to inter- and intra-breath-hold variations, which makes tumor position monitoring during each breath-hold important. A markerless technique is desirable, but limited tumor visibility on kV images makes this challenging. We evaluated if template matching  +  triangulation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac1a9

    authors: Hazelaar C,Dahele M,Mostafavi H,van der Weide L,Slotman B,Verbakel W

    更新日期:2018-05-29 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • Effect of material property heterogeneity on biomechanical modeling of prostate under deformation.

    abstract::Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/195

    authors: Samavati N,McGrath DM,Jewett MA,van der Kwast T,Ménard C,Brock KK

    更新日期:2015-01-07 00:00:00

  • Study of the PTW microLion chamber temperature dependence.

    abstract::The use of liquid ionization chambers in radiotherapy has grown during the past few years. While for air ionization chambers the k(TP) correction for air mass density due to pressure and temperature variations is well known, less work has been done on the case of liquid ionization chambers, where there is still the ne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2705

    authors: Gómez F,González-Castaño D,Díaz-Botana P,Pardo-Montero J

    更新日期:2014-06-07 00:00:00

  • Computed LET distributions in the build-up region of tissue for 14 MeV neutrons.

    abstract::Experimental radiobiological investigations of fast neutron beams involve irradiation of thin cell layers. The irradiation of cells is done either in free air or with a material such as graphite, TE plastic or bone-equivalent plastic covering the cells. This paper discusses the computed dose distributions in LET at sh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/5/007

    authors: Bhatia DP,Nagarajan PS

    更新日期:1979-09-01 00:00:00

  • Dynamic manipulation of the subharmonic scattering of phospholipid-coated microbubbles.

    abstract::In this paper, the influence of a dynamic variation in the ambient pressure on the subharmonic response of phospholipid-coated microbubbles was investigated. The ambient pressure in water was modulated by a 2.5 kHz acoustic wave with a peak amplitude of 15 kPa. We investigated the fundamental and subharmonic emissions...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/19/018

    authors: Faez T,Renaud G,Defontaine M,Calle S,de Jong N

    更新日期:2011-10-07 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent.

    abstract::A single photon absorptiometry method to measure the arterial concentration of injected iodinated contrast agent was developed. A prototype absorptiometry unit was built which consists of either a square or circular cross section acrylic (polymethylmethacrylate) cuvette connected to an arterial catheter at one end and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/9/002

    authors: Yeung WT,Lee TY,Del Maestro RF,Kozak R,Bennett JD,Brown T

    更新日期:1992-09-01 00:00:00

  • Response of x-ray intensifying screens to scattered and primary radiation.

    abstract::The energy dependence of the luminance ratio due to scattered and primary radiation has been determined for four types of X-ray intensifying screens. A water phantom of 30 cm X 30 cm X 20 cm was used as the scattering medium. Ten narrow band X-ray spectra were used as incident radiation: the mean energies of these spe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/007

    authors: Koedooder K,Venema HW

    更新日期:1984-10-01 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation.

    abstract::The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/008

    authors: Fiorino C,Maggiulli E,Broggi S,Liberini S,Cattaneo GM,Dell'oca I,Faggiano E,Di Muzio N,Calandrino R,Rizzo G

    更新日期:2011-06-07 00:00:00

  • Modelling individual temperature profiles from an isolated perfused bovine tongue.

    abstract::To predict the temperature distribution during hyperthermia treatments a thermal model that accounts for the thermal effect of blood flow is mandatory. The DIscrete VAsculature (DIVA) thermal model developed at our department is able to do so; geometrically described vessels are handled individually and the remaining ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/314

    authors: Raaymakers BW,Crezee J,Lagendijk JJ

    更新日期:2000-03-01 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coil.

    abstract::Heating induced near deep brain stimulation (DBS) lead electrodes during magnetic resonance imaging with a 3 T transceive head coil was measured, modeled, and imaged in three cadaveric porcine heads (mean body weight = 85.47 ± 3.19 kg, mean head weight = 5.78 ± 0.32 kg). The effect of the placement of the extra-crania...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5651

    authors: Shrivastava D,Abosch A,Hughes J,Goerke U,DelaBarre L,Visaria R,Harel N,Vaughan JT

    更新日期:2012-09-07 00:00:00

  • Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    abstract::A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/14/5413

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJ

    更新日期:2015-07-21 00:00:00

  • Mathematical modelling of the human cardiovascular system in the presence of stenosis.

    abstract::This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large n...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/3/004

    authors: Sud VK,Srinivasan RS,Charles JB,Bungo MW

    更新日期:1993-03-01 00:00:00

  • Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography.

    abstract::The objective of this study was to be able to distinguish between healthy skin tissue and malignant ones, furthermore determining a unique pattern of roughness for each skin lesion by microtopographic analysis of the skin surface of Mexican patients during the period from April to October 2002. The standard technique ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/008

    authors: del Carmen López Pacheco M,da Cunha Martins-Costa MF,Zapata AJ,Cherit JD,Gallegos ER

    更新日期:2005-12-07 00:00:00

  • Comment on 'the use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics'.

    abstract::In this letter the authors highlight the presence of an error appearing in the discussion of the note 'The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics' previously published by them (Binzoni et al 2006 Phys. Med. Biol. 51 N313). In the light of this error, the discussion ...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/51/22/L01

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-11-21 00:00:00

  • Medical applications of synchrotron radiation.

    abstract::The medical imaging and therapeutic technologies that are based on the use of radiation are reviewed briefly, with special emphasis on the recent developments of synchrotron radiation (SR) methods. New results have been achieved in all of these areas since the last comprehensive reviews were written in this field. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/48/13/201

    authors: Suortti P,Thomlinson W

    更新日期:2003-07-07 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP).

    abstract::Microbeam radiation therapy (MRT) is a pre-clinical, spatially-fractionated treatment modality noted for its ability to achieve a large differential response between normal and tumoral tissues. In the present study, TOPAS Monte Carlo (MC) simulations were used to optimize the design of a compact, affordable multi-slit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad7e2

    authors: Esplen NM,Chergui L,Johnstone CD,Bazalova-Carter M

    更新日期:2018-08-29 00:00:00

  • An iodine-125 thyroid measurement method.

    abstract::A two-probe technique has been developed to measure 125I in the thyroid. In this technique simultaneous emissions from a source are detected as coincidence events between two probes rather than as a sum peak in a single probe (the sum peak method). The background count rate when counting coincidence events between pro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/3/004

    authors: Burns PA,Peggie JR

    更新日期:1980-05-01 00:00:00

  • Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications.

    abstract::The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/5/005

    authors: Zoetelief J,Broerse JJ

    更新日期:1983-05-01 00:00:00

  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • A task-based quality control metric for digital mammography.

    abstract::A reader study was conducted to tune the parameters of an observer model used to predict the detectability index (dʹ ) of test objects as a task-based quality control (QC) metric for digital mammography. A simple test phantom was imaged to measure the model parameters, namely, noise power spectrum,modulation transfer ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6621

    authors: Bloomquist AK,Mainprize JG,Mawdsley GE,Yaffe MJ

    更新日期:2014-11-07 00:00:00

  • Novel adaptive beam-dependent margins for additional OAR sparing.

    abstract::Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae658

    authors: Tsang HS,Kamerling CP,Ziegenhein P,Nill S,Oelfke U

    更新日期:2018-10-29 00:00:00