Abstract:
:A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to the ratio of the cumulative dose at the middle of a CT scan to the volume weighted CTDI (CTDIvol), and was investigated for conventional multi-slice CT scanners operating with a moving table. As the stationary table mode, which is the basis for cone beam CT (CBCT) scans, differs from that used for conventional CT scans, the aim of this study was to investigate the extension of the Gx(L) function to CBCT scans. An On-Board Imager (OBI) system integrated with a TrueBeam linac was simulated with Monte Carlo EGSnrc/BEAMnrc, and the absorbed dose was calculated within PMMA, polyethylene (PE), and water head and body phantoms using EGSnrc/DOSXYZnrc, where the body PE body phantom emulated the ICRU/AAPM phantom. Beams of width 40-500 mm and beam qualities at tube potentials of 80-140 kV were studied. Application of a modified function of beam width (W) termed Gx(W), for which the cumulative dose for CBCT scans f (0) is normalized to the weighted CTDI (CTDIw) for a reference beam of width 40 mm, was investigated as a possible option. However, differences were found in Gx(W) with tube potential, especially for body phantoms, and these were considered to be due to differences in geometry between wide beams used for CBCT scans and those for conventional CT. Therefore, a modified function Gx(W)100 has been proposed, taking the form of values of f (0) at each position in a long phantom, normalized with respect to dose indices f 100(150)x measured with a 100 mm pencil ionization chamber within standard 150 mm PMMA phantoms, using the same scanning parameters, beam widths and positions within the phantom. f 100(150)x averages the dose resulting from a CBCT scan over the 100 mm length. Like the Gx(L) function, the Gx(W)100 function showed only a weak dependency on tube potential at most positions for the phantoms studied. The results were fitted to polynomial equations from which f (0) within the longer PMMA, PE, or water phantoms can be evaluated from measurements of f 100(150)x. Comparisons with other studies, suggest that these functions may be suitable for application to any CT or CBCT scan acquired with stationary table mode.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJdoi
10.1088/0031-9155/60/14/5413subject
Has Abstractpub_date
2015-07-21 00:00:00pages
5413-38issue
14eissn
0031-9155issn
1361-6560journal_volume
60pub_type
杂志文章abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/21/5/011
更新日期:1976-09-01 00:00:00
abstract::Current dosimetry protocols recommend the use of plane-parallel ionization chambers for the dosimetry of clinical electron beams. The necessary perturbation corrections p(wall) and p(cav) are assumed to be unity, independent of the depth of measurement and the energy of the primary electrons. To verify these assumptio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/8/011
更新日期:2009-04-21 00:00:00
abstract::ICRP Publication 116 on 'Conversion coefficients for radiological protection quantities for external radiation exposures', provides fluence-to-dose conversion coefficients for organ-absorbed doses and effective dose for various types of external exposures (ICRP 2010 ICRP Publication 116). The publication supersedes th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/18/5209
更新日期:2014-09-21 00:00:00
abstract::Elevated interstitial fluid pressure is one of the barriers of drug delivery in solid tumors. Recent studies have shown that normalization of tumor vasculature by anti-angiogenic factors may improve the delivery of conventional cytotoxic drugs, possibly by increasing blood flow, decreasing interstitial fluid pressure,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/4/1477
更新日期:2015-02-21 00:00:00
abstract::Commercial TPSs typically model the tongue-and-groove (TG) by extending the projections of the leaf sides by a certain constant width. However, this model may produce discrepancies of as much as 7%-10% in the calculated average doses, especially for the High Definition multi-leaf collimator (MLC) (Hernandez et al 2017...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf098
更新日期:2018-12-10 00:00:00
abstract::Radiomic features achieve promising results in cancer diagnosis, treatment response prediction, and survival prediction. Our goal is to compare the handcrafted (explicitly designed) and deep learning (DL)-based radiomic features extracted from pre-treatment diffusion-weighted magnetic resonance images (DWIs) for predi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7970
更新日期:2020-04-02 00:00:00
abstract::We present a comparison of simulated low-frequency electromagnetic fields in the human body, calculated by means of the electro-quasistatic formulation. The geometrical data in these simulations were provided by an anatomically realistic, high-resolution human body model, while the dielectric properties of the various...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/19/N02
更新日期:2005-10-07 00:00:00
abstract::All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose e...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/11/010
更新日期:2009-06-07 00:00:00
abstract::Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabili...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/20/004
更新日期:2004-10-21 00:00:00
abstract::During image-guided cancer radiation treatment, three-dimensional (3D) tumor volumetric information is important for treatment success. However, it is typically not feasible to image a patient's 3D tumor continuously in real time during treatment due to concern over excessive patient radiation dose. We present a new i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa56b2
更新日期:2017-02-21 00:00:00
abstract::While megavoltage cone-beam computed tomography (CBCT) using an electronic portal imaging device (EPID) provides many advantages over kilovoltage (kV) CBCT, clinical adoption is limited by its high doses. Multi-layer imager (MLI) EPIDs increase DQE(0) while maintaining high resolution. However, even well-designed, hig...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa160
更新日期:2018-01-30 00:00:00
abstract::Non-invasive evaluation of the Achilles tendon elastic properties may enhance diagnosis of tendon injury and the assessment of recovery treatments. Shear wave elastography has shown to be a powerful tool to estimate tissue mechanical properties. However, its applicability to quantitatively evaluate tendon stiffness is...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/3/505
更新日期:2014-02-07 00:00:00
abstract::The purpose of this study was to evaluate the impact of numerical errors caused by the floating point representation of real numbers in a GPU-based Monte Carlo code used for dose calculation in radiation oncology, and to identify situations where this type of error arises. The program used as a benchmark was bGPUMCD. ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/13/5007
更新日期:2015-07-07 00:00:00
abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/20/4/006
更新日期:1975-07-01 00:00:00
abstract::In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be idea...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/14/011
更新日期:2011-07-21 00:00:00
abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/12/002
更新日期:1991-12-01 00:00:00
abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/18/311
更新日期:2002-09-21 00:00:00
abstract::Electronic article surveillance (EAS) devices are widely used in most stores as anti-theft systems. In this work, the compliance with international guidelines in the human exposure to these devices is analysed by using the finite-difference time-domain (FDTD) method. Two sets of high resolution numerical phantoms of d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/4/009
更新日期:2010-02-21 00:00:00
abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/313
更新日期:1999-07-01 00:00:00
abstract::This is a proof of principle study on an algorithm for optimizing external beam radiotherapy in terms of both photon beamlet energy and fluence. This simultaneous beamlet energy and fluence optimization is denoted modulated photon radiotherapy (XMRT). XMRT is compared with single-energy intensity modulated radiotherap...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/4/1476
更新日期:2016-02-21 00:00:00
abstract::Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct ra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/7/016
更新日期:2006-04-07 00:00:00
abstract::The poor agreement in the photon calibrations of tissue-equivalent ionisation chambers between different participants in two major neutron dosimetry intercomparisons is noted. The methods of converting measurements made with a calibrated secondary standard exposure meter to the absorbed dose in the wall of a tissue-eq...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/25/2/002
更新日期:1980-03-01 00:00:00
abstract::Time- and space-resolved diffuse reflectance measurements were used to identify the optical parameters, the reduced scattering and absorption coefficients, of bulk living tissue in the region from 1.15 to 1.52 microm. Although in this region the detector was limited in its temporal resolution, we applied a peak-time s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/11/021
更新日期:2006-06-07 00:00:00
abstract::For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron stor...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/24/8231
更新日期:2012-12-21 00:00:00
abstract::Recent theoretical research on spatiobiologically integrated radiotherapy has focused on optimization models that adapt fluence-maps to the evolution of tumor state, for example, cell densities, as observed in quantitative functional images acquired over the treatment course. We propose an optimization model that adap...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aab4b6
更新日期:2018-03-27 00:00:00
abstract::The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead o...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/11/002
更新日期:2011-06-07 00:00:00
abstract::We have shown that irradiation changes the dielectric properties of human skin at radiofrequencies. Both the dielectric constant and the conductivity of the irradiated skin decrease, especially at low frequencies. The experimental data were analysed using two bioelectric models. Relevant dielectric parameters were det...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/6/001
更新日期:1994-06-01 00:00:00
abstract::This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa97f8
更新日期:2017-12-19 00:00:00
abstract::Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and ¹⁰⁰Mo(p,2n)(99m)Tc reaction has been considered. In this context, the production yields of (99m)Tc and various other radioactive and stable isotopes which will be created in the ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/17/002
更新日期:2011-09-07 00:00:00
abstract::A mathematical procedure, using Fourier deconvolution, is described whereby diffusion-free proximity functions can be obtained from cloud-chamber data. Such non-diffused distributions can be used to obtain further microdosimetric and nanodosimetric quantities hitherto not available from experiments, thus making the cl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/33/11/004
更新日期:1988-11-01 00:00:00