Monte Carlo optimization of a microbeam collimator design for use on the small animal radiation research platform (SARRP).

Abstract:

:Microbeam radiation therapy (MRT) is a pre-clinical, spatially-fractionated treatment modality noted for its ability to achieve a large differential response between normal and tumoral tissues. In the present study, TOPAS Monte Carlo (MC) simulations were used to optimize the design of a compact, affordable multi-slit collimator (MSC) suitable for use with the small animal radiation research platform (SARRP). MRT dose distributions in a (1  ×  1  ×  3)cm3 water phantom were simulated for a tungsten MSC using different focal spot sizes (0.4, 3 mm), beam energies (40, 80, 220 kVp), slit widths (100, 125, 150, 175, 200 µm), collimator thicknesses (1.5, 2.5, 3 cm) and collimator-to-surface distances (CSD of 1 and 3 cm). Key MRT figures of merit, namely the peak-to-valley dose ratio (PVDR), full-width at half-maximum and peak dose rate were determined. Use of the small focal spot maximized the PVDR (~40 at surface) and reduced the system's sensitivity to changes in CSD, but decreased the collimated beam output to 55.2 cGy min-1. The large focal spot was ill-suited for large CSD irradiations, but increased the beam output by a factor of 2.8, to 153.0 cGy min-1, and decreased the sensitivity to changes in slit width. A modular MSC, using divergent plastic spacer materials in place of excavated slits, was also investigated. Polypropylene and polyethylene terephthalate material spacers were considered and while neither reduced the PVDR compared to air slits, the dose rate was reduced by 37% and 47%, respectively. Lastly, a steel parallel-slit MSC was used in a preliminary test of MRT delivery using the SARRP. Discrepancies between the results of film dosimetry and the corresponding MC simulations highlight the need to fabricate a more well-defined collimator for use in future validation and radiobiological work. The simulated results of this study are being used to inform the design of such a collimator, which will additionally boast a high degree of modularity at reasonable cost.

journal_name

Phys Med Biol

authors

Esplen NM,Chergui L,Johnstone CD,Bazalova-Carter M

doi

10.1088/1361-6560/aad7e2

subject

Has Abstract

pub_date

2018-08-29 00:00:00

pages

175004

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

63

pub_type

杂志文章
  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • Experimental determination of the energy response of alanine pellets in the high dose rate 192Ir spectrum.

    abstract::An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/20/007

    authors: Schaeken B,Cuypers R,Goossens J,Van den Weyngaert D,Verellen D

    更新日期:2011-10-21 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • Four-dimensional Monte Carlo simulation of time-dependent geometries.

    abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/n03

    authors: Paganetti H

    更新日期:2004-03-21 00:00:00

  • Optimization of the artificial urinary sphincter: modelling and experimental validation.

    abstract::The artificial urinary sphincter should be long enough to prevent strangulation effects of the urethral tissue and short enough to avoid the improper dissection of the surrounding tissue. To optimize the sphincter length, the empirical three-parameter urethra compression model is proposed based on the mechanical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/023

    authors: Marti F,Leippold T,John H,Blunschi N,Müller B

    更新日期:2006-03-07 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • Sensitivity study of the microdosimetric kinetic model parameters for carbon ion radiotherapy.

    abstract::In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the loc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae8b4

    authors: Dahle TJ,Magro G,Ytre-Hauge KS,Stokkevåg CH,Choi K,Mairani A

    更新日期:2018-11-12 00:00:00

  • Artefacts in multi-echo T2 imaging for high-precision gel dosimetry: I. Analysis and compensation of eddy currents.

    abstract::In BANG gel dosimetry, the spin-spin relaxation rate, R2 = I/T2, is related to the radiation dose that has been delivered to the gel phantom. R2 is calculated by fitting the pixel intensities of a set of differently T2-weighted base images. In gel dosimetry for radiotherapy, an accuracy of 5% in dose and 3 mm spatiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/7/307

    authors: De Deene Y,De Wagter C,De Neve W,Achten E

    更新日期:2000-07-01 00:00:00

  • Mathematical model of the CA1 region of the rat hippocampus.

    abstract::A mathematical transcription of the intrinsic circuit of the CA1 region of the rat dorsal hippocampus was made and the model parameters adjusted according to experimental data from intracellular recordings and single channel kinetics. This model was able to simulate well the profile of the field potentials recorded ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/9/014

    authors: Almeida AC,Fernandes de Lima VM,Infantosi AF

    更新日期:1998-09-01 00:00:00

  • Calculation of water equivalent ratios for various materials at proton energies ranging 10-500 MeV using MCNP, FLUKA, and GEANT4 Monte Carlo codes.

    abstract::Dosimetry of proton beams is generally evaluated in liquid water, or alternatively in solid phantoms via water equivalent ratios (WER). WER is defined as the ratio of proton range in liquid water to that in a phantom of certain material. Presently, WER is not available in the literature neither for a wide range of ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad0bd

    authors: Safigholi H,Song WY

    更新日期:2018-07-27 00:00:00

  • Ionization quenching in scintillators used for dosimetry of mixed particle fields.

    abstract::Ionization quenching in ion beam dosimetry is often related to the fluence- or dose-averaged linear energy transfer (LET). Both quantities are however averaged over a wide LET range and a mixed field of primary and secondary ions. We propose a novel method to correct the quenched luminescence in scintillators exposed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab12f2

    authors: Christensen JB,Almhagen E,Stolarczyk L,Vestergaard A,Bassler N,Andersen CE

    更新日期:2019-04-29 00:00:00

  • Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

    abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/7/310

    authors: Zaidi H,Diaz-Gomez M,Boudraa A,Slosman DO

    更新日期:2002-04-07 00:00:00

  • Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

    abstract::Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5983

    authors: Ng JA,Booth J,Poulsen P,Kuncic Z,Keall PJ

    更新日期:2013-09-07 00:00:00

  • Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging.

    abstract::Poly(vinyl alcohol) cryogel, PVA-C, is presented as a tissue-mimicking material, suitable for application in magnetic resonance (MR) imaging and ultrasound imaging. A 10% by weight poly(vinyl alcohol) in water solution was used to form PVA-C, which is solidified through a freeze-thaw process. The number of freeze-thaw...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/24/009

    authors: Surry KJ,Austin HJ,Fenster A,Peters TM

    更新日期:2004-12-21 00:00:00

  • Transport-based quantitative photoacoustic tomography: simulations and experiments.

    abstract::In this paper we describe a method for quantitative photoacoustic tomography (qPAT) based on the photon radiative transfer equation (RTE) coupled with the Helmholtz photoacoustic wave equation. Considerable simulations and tissue-like phantom experiments are conducted to evaluate transport-based qPAT in comparison wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/009

    authors: Yao L,Sun Y,Jiang H

    更新日期:2010-04-07 00:00:00

  • A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model.

    abstract::Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm2) was developed in terms of TERMA and a total energy depo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/001

    authors: Aspradakis MM,Redpath AT

    更新日期:1997-08-01 00:00:00

  • Tradeoffs of integrating real-time tracking into IGRT for prostate cancer treatment.

    abstract::This study investigated the integration of the Calypso real-time tracking system, based on implanted ferromagnetic transponders and a detector array, into the current process for image-guided radiation treatment (IGRT) of prostate cancer at our institution. The current IGRT process includes magnetic resonance imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/N03

    authors: Zhu X,Bourland JD,Yuan Y,Zhuang T,O'Daniel J,Thongphiew D,Wu QJ,Das SK,Yoo S,Yin FF

    更新日期:2009-09-07 00:00:00

  • Semi-empirical formulation of multiple scattering for the Gaussian beam model of heavy charged particles stopping in tissue-like matter.

    abstract::Dose calculation for radiotherapy with protons and heavier ions deals with a large volume of path integrals involving a scattering power of body tissue. This work provides a simple model for such demanding applications. There is an approximate linearity between RMS end-point displacement and range of incident particle...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/N01

    authors: Kanematsu N

    更新日期:2009-03-07 00:00:00

  • Optimization of attenuation correction for positron emission tomography studies of thorax and pelvis using count-based transmission scans.

    abstract::The quality of thorax and pelvis transmission scans and therefore of attenuation correction in PET depends on patient thickness and transmission rod source strength. The purpose of the present study was to assess the feasibility of using count-based transmission scans, thereby guaranteeing more consistent image qualit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/n01

    authors: Boellaard R,van Lingen A,van Balen SC,Lammertsma AA

    更新日期:2004-02-21 00:00:00

  • Bulk optical properties of healthy female breast tissue.

    abstract::We have measured the bulk optical properties of healthy female breast tissues in vivo in the parallel plate, transmission geometry. Fifty-two volunteers were measured. Blood volume and blood oxygen saturation were derived from the optical property data using a novel method that employed a priori spectral information t...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/47/16/302

    authors: Durduran T,Choe R,Culver JP,Zubkov L,Holboke MJ,Giammarco J,Chance B,Yodh AG

    更新日期:2002-08-21 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Novel adaptive beam-dependent margins for additional OAR sparing.

    abstract::Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Unfortunately, whilst the use of margins can increase the probability that sufficient dose is delivered to the CTV, it can also result in delivering high dose of r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae658

    authors: Tsang HS,Kamerling CP,Ziegenhein P,Nill S,Oelfke U

    更新日期:2018-10-29 00:00:00

  • Efficient IMRT inverse planning with a new L1-solver: template for first-order conic solver.

    abstract::Intensity modulated radiation therapy (IMRT) inverse planning using total-variation (TV) regularization has been proposed to reduce the complexity of fluence maps and facilitate dose delivery. Conventionally, the optimization problem with L-1 norm is solved with quadratic programming (QP), which is time consuming and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4139

    authors: Kim H,Suh TS,Lee R,Xing L,Li R

    更新日期:2012-07-07 00:00:00

  • Large-angle x-ray scatter in Talbot-Lau interferometry for breast imaging.

    abstract::Monte Carlo simulations were used to investigate large-angle x-ray scatter at design energy of 25 keV during small field of view (9.6 cm × 5 cm) differential phase contrast imaging of the breast using Talbot-Lau interferometry. Homogenous, adipose and fibroglandular breasts of uniform thickness ranging from 2 to 8 cm ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6387

    authors: Vedantham S,Shi L,Karellas A

    更新日期:2014-11-07 00:00:00

  • Exact analytic reconstruction in x-ray fluorescence CT and approximated versions.

    abstract::X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an appr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/007

    authors: Miqueles EX,De Pierro AR

    更新日期:2010-02-21 00:00:00

  • Modelling the temporal region in patients with temporal lobe epilepsy.

    abstract::EEG interictal epileptiform discharges in temporal lobe epilepsy are associated with magnetic fields. The maxima of magnetic spikes recorded over the spherical portions of the head appear fairly symmetric, whereas those over the lower temporal region often have irregular shapes. Furthermore, their magnitude is often u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/009

    authors: Rose DF,Sato S,Smith PD,White J

    更新日期:1987-01-01 00:00:00

  • A further assessment of an electromagnetic method to measure body composition.

    abstract::Two experimental investigations of the electromagnetic method to measure body composition are presented. In the first experiment, the impedance of a single-loop transmitting antenna, located at the centre of a 150 m helical receiving coil, was observed to have a sharp minimum at 2.40 MHz. The impedance of the antenna ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/011

    authors: Sutcliffe JF,Smye SW,Smith MA

    更新日期:1995-04-01 00:00:00

  • Pre- and post-natal exposure of children to EMF generated by domestic induction cookers.

    abstract::Induction cookers are a type of cooking appliance that uses an intermediate-frequency magnetic field to heat the cooking vessel. The magnetic flux density produced by an induction cooker during operation was measured according to the EN 62233 standard, and the measured values were below the limits set in the standard....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/19/001

    authors: Kos B,Valič B,Miklavčič D,Kotnik T,Gajšek P

    更新日期:2011-10-07 00:00:00