Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

Abstract:

:Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose. The additional effective dose is quantified for prostate radiotherapy and compared to dose from other localization modalities. The software PCXMC 2.0 was used to calculate the effective dose delivered to a phantom as a function of imager angle and field size for a Varian On-Board Imager. The average angular effective dose was calculated for a field size of 6 cm × 6 cm. The average angular effective dose was used in calculations for different treatment scenarios. Treatment scenarios considered were treatment type and fractionation. For all treatment scenarios, (i.e. conventionally fractionated and stereotactic body radiotherapy (SBRT), IMRT and IMAT), the total KIM dose at 1 Hz ranged from 2-10 mSv. This imaging dose is less than the Navotek radioactive implant dose (64 mSv) and a standard SBRT cone beam computed tomography pretreatment scan dose (22 mSv) over an entire treatment regime. KIM delivers an acceptably low effective dose for daily use as a real-time image-guidance method for prostate radiotherapy.

journal_name

Phys Med Biol

authors

Ng JA,Booth J,Poulsen P,Kuncic Z,Keall PJ

doi

10.1088/0031-9155/58/17/5983

subject

Has Abstract

pub_date

2013-09-07 00:00:00

pages

5983-96

issue

17

eissn

0031-9155

issn

1361-6560

journal_volume

58

pub_type

杂志文章
  • Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.

    abstract::An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/404

    authors: Alanen E,Lahtinen T,Nuutinen J

    更新日期:1999-07-01 00:00:00

  • Denoising of multi b-value diffusion-weighted MR images using deep image prior.

    abstract::The clinical value of multiple b-value diffusion-weighted (DW) magnetic resonance imaging (MRI) has been shown in many studies. However, DW-MRI often suffers from low signal-to-noise ratio, especially at high b-values. To address this limitation, we present an image denoising method based on the concept of deep image ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8105

    authors: Lin YC,Huang HM

    更新日期:2020-05-11 00:00:00

  • Integral equations and boundary-element solution for static potential in a general piece-wise homogeneous volume conductor.

    abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/22/N606

    authors: Stenroos M

    更新日期:2016-11-21 00:00:00

  • Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

    abstract::Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:

    authors: Marshall NW,Kotre CJ

    更新日期:2002-03-21 00:00:00

  • Prediction of positron emitter distributions for range monitoring in carbon ion therapy: an analytical approach.

    abstract::Range verification is one of the most relevant tasks in ion beam therapy. In the case of carbon ion therapy, positron emission tomography (PET) is the most widely used method for this purpose, which images the [Formula: see text]-activation following nuclear interactions of the ions with the tissue nuclei. Since the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab17f9

    authors: Hofmann T,Fochi A,Parodi K,Pinto M

    更新日期:2019-05-21 00:00:00

  • Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry.

    abstract::The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual trace...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3585

    authors: White SA,Landry G,van Gils F,Verhaegen F,Reniers B

    更新日期:2012-06-07 00:00:00

  • Measurements of angular distributions of Rayleigh and Mie scattering events in biological models.

    abstract::Remission spectroscopy in living tissues can only be performed because scattering processes induce a pronounced amount of backscattered light. New types of scattering chambers were constructed in order to investigate the angular distribution of light intensities caused by scattering events typical for living tissues. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/12/012

    authors: Frank KH,Kessler M,Appelbaum K,Albrecht HP,Mauch ED

    更新日期:1989-12-01 00:00:00

  • A radiographic technique for measuring the powder packing density in the cavities of trabecular bone.

    abstract::An X-ray technique has been developed to enable reproducible and quantitative data to be obtained from radiographs taken by a diagnostic X-ray machine. Careful attention has been paid to the alignment of the specimen and the diagnostic tube and to operating conditions. The choice of X-ray spectrum is described togethe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/4/003

    authors: King SD

    更新日期:1977-07-01 00:00:00

  • Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy.

    abstract::Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4601

    authors: Han X,Pearson E,Pelizzari C,Al-Hallaq H,Sidky EY,Bian J,Pan X

    更新日期:2015-06-21 00:00:00

  • Temperature distribution in atherosclerotic coronary arteries: influence of plaque geometry and flow (a numerical study).

    abstract::Intravascular coronary thermography is a method that may detect vulnerable, atherosclerotic plaques and is currently evaluated in a clinical setting. Active macrophages or enzymatic heat releasing processes in vulnerable plaques may act as heat sources. To better understand the parameters of influence on thermographic...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/19/001

    authors: ten Have AG,Gijsen FJ,Wentzel JJ,Slager CJ,van der Steen AF

    更新日期:2004-10-07 00:00:00

  • Effect of dominant features on neural network performance in the classification of mammographic lesions.

    abstract::Two different classifiers, an artificial neural network (ANN) and a hybrid system (one step rule-based method followed by an artificial neural network) have been investigated to merge computer-extracted features in the task of differentiating between malignant and benign masses. A database consisting of 65 cases (38 m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/10/315

    authors: Huo Z,Giger ML,Metz CE

    更新日期:1999-10-01 00:00:00

  • Modelling individual temperature profiles from an isolated perfused bovine tongue.

    abstract::To predict the temperature distribution during hyperthermia treatments a thermal model that accounts for the thermal effect of blood flow is mandatory. The DIscrete VAsculature (DIVA) thermal model developed at our department is able to do so; geometrically described vessels are handled individually and the remaining ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/314

    authors: Raaymakers BW,Crezee J,Lagendijk JJ

    更新日期:2000-03-01 00:00:00

  • Temperature elevation in the eye of anatomically based human head models for plane-wave exposures.

    abstract::This study investigated the temperature elevation in the eye of anatomically based human head models for plane-wave exposures. The finite-difference time-domain method is used for analyzing electromagnetic absorption and temperature elevation. The eyes in the anatomic models have average dimensions and weight. Computa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/003

    authors: Hirata A,Watanabe S,Fujiwara O,Kojima M,Sasaki K,Shiozawa T

    更新日期:2007-11-07 00:00:00

  • Automated 3D ultrasound image analysis for first trimester assessment of fetal health.

    abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3ad1

    authors: Ryou H,Yaqub M,Cavallaro A,Papageorghiou AT,Alison Noble J

    更新日期:2019-09-17 00:00:00

  • Relative electron density determination using a physics based parameterization of photon interactions in medical DECT.

    abstract::Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides the electron densi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/9/3825

    authors: van Abbema JK,van Goethem MJ,Greuter MJ,van der Schaaf A,Brandenburg S,van der Graaf ER

    更新日期:2015-05-07 00:00:00

  • Comment on 'the use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics'.

    abstract::In this letter the authors highlight the presence of an error appearing in the discussion of the note 'The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics' previously published by them (Binzoni et al 2006 Phys. Med. Biol. 51 N313). In the light of this error, the discussion ...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/51/22/L01

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-11-21 00:00:00

  • FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines.

    abstract::This study investigated the relationship between the specific absorption rate and temperature elevation in an anatomically-based model named NORMAN for exposure to radio-frequency far fields in the ICNIRP guidelines (1998 Health Phys. 74 494-522). The finite-difference time-domain method is used for analyzing the elec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/020

    authors: Hirata A,Asano T,Fujiwara O

    更新日期:2007-08-21 00:00:00

  • Diaphragm correction factors for free-air chamber standards for air kerma in x-rays.

    abstract::At present, only a correction factor for photon transmission, k(l), is systematically applied for the entrance diaphragm of free-air chamber standards for air kerma. In the present work, the Monte Carlo code PENELOPE is used to re-evaluate k(l) for the BIPM standards and new correction factors are calculated for photo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/009

    authors: Burns DT,Kessler C

    更新日期:2009-05-07 00:00:00

  • Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.

    abstract::The measurement of beam data for dynamic wedge dosimetry requires the integration of radiation dose at points across the radiation field during the dose delivery. The different measurement techniques required when using a linear diode array to measure beam profiles and when using ionization chambers to measure depth d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/3/005

    authors: Bidmead AM,Garton AJ,Childs PJ

    更新日期:1995-03-01 00:00:00

  • Effects of body habitus on internal radiation dose calculations using the 5-year-old anthropomorphic male models.

    abstract::Computational phantoms are commonly used in internal radiation dosimetry to assess the amount and distribution pattern of energy deposited in various parts of the human body from different internal radiation sources. Radiation dose assessments are commonly performed on predetermined reference computational phantoms wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa75b4

    authors: Xie T,Kuster N,Zaidi H

    更新日期:2017-07-13 00:00:00

  • Single patient convolutional neural networks for real-time MR reconstruction: a proof of concept application in lung tumor segmentation for adaptive radiotherapy.

    abstract::Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab408e

    authors: Dietz B,Yun J,Yip E,Gabos Z,Fallone BG,Wachowicz K

    更新日期:2019-09-23 00:00:00

  • Multi-layer imager design for mega-voltage spectral imaging.

    abstract::The architecture of multi-layer imagers (MLIs) can be exploited to provide megavoltage spectral imaging (MVSPI) for specific imaging tasks. In the current work, we investigated bone suppression and gold fiducial contrast enhancement as two clinical tasks which could be improved with spectral imaging. A method based on...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabe21

    authors: Myronakis M,Hu YH,Fueglistaller R,Wang A,Baturin P,Huber P,Morf D,Star-Lack J,Berbeco R

    更新日期:2018-05-10 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • In vivo micro-CT lung imaging via a computer-controlled intermittent iso-pressure breath hold (IIBH) technique.

    abstract::Respiratory research with mice using micro-computed tomography (micro-CT) has been predominantly hindered by the limited resolution and signal-to-noise ratio (SNR) as a result of respiratory motion artefacts. In this study, we develop a novel technique for capturing the lung microstructure in vivo using micro-CT, thro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/008

    authors: Namati E,Chon D,Thiesse J,Hoffman EA,de Ryk J,Ross A,McLennan G

    更新日期:2006-12-07 00:00:00

  • Optimization of multiply acquired magnetic flux density B(z) using ICNE-Multiecho train in MREIT.

    abstract::The aim of magnetic resonance electrical impedance tomography (MREIT) is to visualize the electrical properties, conductivity or current density of an object by injection of current. Recently, the prolonged data acquisition time when using the injected current nonlinear encoding (ICNE) method has been advantageous for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/9/021

    authors: Nam HS,Kwon OI

    更新日期:2010-05-07 00:00:00

  • An investigation into the vector ellipticity of extremely low frequency magnetic fields from appliances in UK homes.

    abstract::Elliptically polarized magnetic fields induce higher currents in the body compared with their plane polarized counterparts. This investigation examines the degree of vector ellipticity of extremely low frequency magnetic fields (ELF-MFs) in the home, with regard to the adverse health effects reportedly associated with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/016

    authors: Ainsbury EA,Conein E,Henshaw DL

    更新日期:2005-07-07 00:00:00

  • Large blood vessel cooling in heated tissues: a numerical study.

    abstract::Large blood vessels can produce steep temperature gradients in heated tissues leading to inadequate tissue temperatures during hyperthermia. This paper utilizes a finite difference scheme to solve the basic equations of heat transfer and fluid flow to model blood vessel cooling. Unlike previous formulations, heat tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/4/001

    authors: Kolios MC,Sherar MD,Hunt JW

    更新日期:1995-04-01 00:00:00

  • Volume-selective and spectroscopically resolved NMR investigation of diffusion and relaxation in fertilised hen eggs.

    abstract::A radiofrequency and field-gradient pulse sequence is presented permitting the non-invasive, volume-selective and spectroscopically resolved determination of incoherent transport parameters with the aid of an NMR field-gradient method. With proton NMR, diffusion or (quasi-incoherent) perfusion coefficients as low as 1...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/1/007

    authors: Klammler F,Kimmich R

    更新日期:1990-01-01 00:00:00

  • Medical personnel and patient dosimetry during coronary angiography and intervention.

    abstract::Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/48/18/307

    authors: Efstathopoulos EP,Makrygiannis SS,Kottou S,Karvouni E,Giazitzoglou E,Korovesis S,Tzanalaridou E,Raptou PD,Katritsis DG

    更新日期:2003-09-21 00:00:00