Abstract:
:Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 T Philips Achieva system. A retrospective analysis was performed on six non-small cell lung cancer patients who received fully sampled dynamic acquisitions consisting of 650 free breathing images using a bSSFP sequence. We retrospectively undersampled the six patient's data by 5× and 10× acceleration. The retrospective data was used to quantitatively compare the CNN reconstruction to gold truth data via the Dice coefficient (DC) and centroid displacement to compare the tumor segmentations. Reconstruction noise was investigated using the normalized mean square error (NMSE). We further validated the technique using prospectively undersampled data from a volunteer and motion phantom. The retrospectively undersampled data at 5× and 10× acceleration was reconstructed using patient specific trained CNNs. The patient average DCs for the tumor segmentation at 5× and 10× acceleration were 0.94 and 0.92, respectively. These DC values are greater than the inter- and intra-observer segmentations acquired by radiation oncologist experts as reported in a previous study of ours. Furthermore, the patient specific CNN can be trained in under 6 h and the reconstruction time was 65 ms per image. The prospectively undersampled CNN reconstruction data yielded qualitatively acceptable images. We have shown that 3D CNNs can be used for real-time on-the-fly dynamic image reconstruction utilizing both spatial and temporal data in this proof of concept study. We evaluated the technique using six retrospectively undersampled lung cancer patient data sets, as well as prospectively undersampled data acquired from a volunteer and motion phantom. The reconstruction speed achieved for our current implementation was 65 ms per image.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Dietz B,Yun J,Yip E,Gabos Z,Fallone BG,Wachowicz Kdoi
10.1088/1361-6560/ab408esubject
Has Abstractpub_date
2019-09-23 00:00:00pages
195002issue
19eissn
0031-9155issn
1361-6560journal_volume
64pub_type
杂志文章abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/6/1685
更新日期:2012-03-21 00:00:00
abstract::Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/11/3597
更新日期:2012-06-07 00:00:00
abstract::Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major d...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/12/310
更新日期:2000-12-01 00:00:00
abstract::Ion beam therapy offers the possibility of a highly conformal tumor-dose distribution; however, this technique is extremely sensitive to inaccuracies in the treatment procedures. Ambiguities in the conversion of Hounsfield units of the treatment planning x-ray CT to relative stopping power (RSP) can cause uncertaintie...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5602
更新日期:2017-02-07 00:00:00
abstract::Dual-energy x-ray absorptiometry (DXA) is widely applied for estimating body fat. The percentage of body mass as fat (%fat) is predicted from a DXA-estimated R(ST) value defined as the ratio of soft tissue attenuation at two photon energies (e.g., 40 keV and 70 keV). Theoretically, the R(ST) concept depends on the mas...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/9/013
更新日期:2010-05-07 00:00:00
abstract::Rheumatoid arthritis is one of the most common epidemic diseases in the world. For some patients, the treatment with steroids or nonsteroidal anti-inflammatory drugs is not effective, thus necessitating physical removal of the inflamed synovium. Alternative approaches other than surgery will provide appropriate diseas...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/6/014
更新日期:2007-03-21 00:00:00
abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/19/002
更新日期:2008-10-07 00:00:00
abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/21/5/011
更新日期:1976-09-01 00:00:00
abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa186
更新日期:2018-01-22 00:00:00
abstract::Several types of intravascular ultrasound (IVUS) catheters are connected to a motor at their proximal end, in order to let the catheter rotate around its length axis. However, the rotation of the distal axis tip does not follow exactly the rotation of the motor, since the catheter axis is not completely torsion-free a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/001
更新日期:1998-05-01 00:00:00
abstract::Respiratory induced resonance offset (RIRO) is a periodic disturbance of a magnetic field due to breathing. Such disturbance handicaps the accuracy of the proton resonance frequency shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method c...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/18/015
更新日期:2006-09-21 00:00:00
abstract::Nuclear emulsions of the Ilford K series, exposed to X-rays from 15 to 150 kVp and systematically underdeveloped, exhibit supralinear blackness--exposure curves ranging from 1- to 4-hit in character, and whose shape is the same at all excitation voltages. Processing can be so adjusted that the curve shape is well repr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/23/6/007
更新日期:1978-11-01 00:00:00
abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/5/014
更新日期:1977-09-01 00:00:00
abstract::Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that ver...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/14/4627
更新日期:2012-07-21 00:00:00
abstract::Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/1/009
更新日期:1996-01-01 00:00:00
abstract::In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of H...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/7/013
更新日期:2005-04-07 00:00:00
abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad9b5
更新日期:2018-09-06 00:00:00
abstract::Analytic solutions to the time-dependent multiregion bioheat equation are evaluated numerically for cartesian and spherical models. Principle and alternate branch contributions to the solutions are examined. The calculations include a parametric investigation and analyses of temperature behaviour in idealised upper th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/35/7/005
更新日期:1990-07-01 00:00:00
abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/3/1325
更新日期:2015-02-07 00:00:00
abstract::Using iterative three-dimensional (3D) reconstruction techniques for reconstruction of positron emission tomography (PET) is not feasible on most single-processor machines due to the excessive computing time needed, especially so for the large sinogram sizes of our high-resolution research tomograph (HRRT). In our fir...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/15/307
更新日期:2002-08-07 00:00:00
abstract::A new method for correcting simultaneously the attenuation, scatter and resolution effects in SPECT has been developed for the case of a homogeneous medium. It is based on an effective model of the scatter process. This model depends on only four parameters which are determined experimentally and remain independent of...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/4/005
更新日期:1994-04-01 00:00:00
abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/17/4961
更新日期:2014-09-07 00:00:00
abstract::In this paper we describe measurements of the contrast transfer function, modulation transfer function and point-spread function of an optical coherence tomography (OCT) imaging system through scattering layers having a dimension-less scattering depth over the range 0.2-6.9. The results were found to be insensitive to...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/9/014
更新日期:2011-05-07 00:00:00
abstract::Geometric and penetration responses of a multihole focusing collimator to a point source have been determined using a digital computer and a ray tracing technique. Results are presented as point and line spread functions for collimated rays and penetrating rays, and as plane sensitivities and modulation transfer funct...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/1/011
更新日期:1981-01-01 00:00:00
abstract::Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/4/014
更新日期:1998-04-01 00:00:00
abstract::Monte Carlo (MC) simulations are often at the heart of the testing procedure in biomedical optics. One of the critical points in MC simulations is to define the new photon direction after each scattering event. One of the most popular solutions is to use the Henyey-Greenstein phase function or some linear combinations...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/17/N04
更新日期:2006-09-07 00:00:00
abstract::We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer cleara...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/46/8/302
更新日期:2001-08-01 00:00:00
abstract::A new multiplicative correction factor for tissue heterogeneities based on an exact expression for homogeneous non-unit-density media is proposed. O'Connor's density scaling theorem is invoked to evaluate the medium-specific tissue-maximum ratios used in the exact formulation. Monte Carlo calculations were performed a...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/31/10/005
更新日期:1986-10-01 00:00:00
abstract::Monte Carlo simulation with PENELOPE (version 2003) is applied to calculate Leksell Gamma Knife dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different sim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/23/018
更新日期:2005-12-07 00:00:00
abstract::Near-infrared fluorescence optical imaging has the unique opportunity of differentiating diseased lesions from normal lesions based upon environmentally indicated changes in the lifetime of a fluorescent imaging agent. In this paper, we demonstrate three-dimensional lifetime tomography using the gradient-based penalty...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/14/009
更新日期:2007-07-21 00:00:00