Abstract:
:Nuclear emulsions of the Ilford K series, exposed to X-rays from 15 to 150 kVp and systematically underdeveloped, exhibit supralinear blackness--exposure curves ranging from 1- to 4-hit in character, and whose shape is the same at all excitation voltages. Processing can be so adjusted that the curve shape is well represented by the alpha--beta model, and matches an experimental dose--response curve obtained with hamster cells after irradiation with gamma rays. The effective grain size of these emulsions is 1.3 micron when normalised to unit density material for comparison with the radiation sensitive elements of biological cells. With fractionated exposures, response curves which mimic Elkind recovery are produced.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Katz R,Pennington ECdoi
10.1088/0031-9155/23/6/007subject
Has Abstractpub_date
1978-11-01 00:00:00pages
1115-23issue
6eissn
0031-9155issn
1361-6560journal_volume
23pub_type
杂志文章abstract::Using Cherenkov radiation in positron emission tomography (PET) has the potential to improve the time of flight (TOF) resolution and reduce the cost of detectors. In previous studies promising TOF results were achieved when lead fluoride (PbF2) crystals were used instead of a scintillator. In this work, a whole-body P...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab6f97
更新日期:2020-03-06 00:00:00
abstract::Volumetric scintillation dosimetry has the potential to provide fast, high-resolution, three-dimensional radiation dosimetry. However, scintillators exhibit a nonlinear response at the high linear energy transfer (LET) values characteristic of proton Bragg peaks. The purpose of this study was to develop a quenching co...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/2/261
更新日期:2013-01-21 00:00:00
abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/41/10/024
更新日期:1996-10-01 00:00:00
abstract::Cardiac and respiratory motion artefacts in PET imaging have been traditionally resolved by acquiring the data in gated mode. However, gated PET images are usually characterized by high noise content due to their low photon statistics. In this paper, we present a novel 4D model for the PET imaging system, which can in...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/15/012
更新日期:2006-08-07 00:00:00
abstract::To evaluate the effect of approximations in clinical analytical calculations performed by a treatment planning system (TPS) on dosimetric indices in intensity modulated proton therapy. TPS calculated dose distributions were compared with dose distributions as estimated by Monte Carlo (MC) simulations, calculated with ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa845
更新日期:2018-02-09 00:00:00
abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/18/009
更新日期:2010-09-21 00:00:00
abstract::The aim of this study is to investigate the feasibility of using conventional jaws to deliver inverse planned intensity-modulated radiotherapy (IMRT) plans for patients with prostate cancer. For ten patients, each had one three-dimensional conformal plan (3D plan) and seven inverse IMRT plans using direct aperture opt...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,随机对照试验
doi:10.1088/0031-9155/52/8/007
更新日期:2007-04-21 00:00:00
abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5452
更新日期:2017-04-21 00:00:00
abstract::Most tissue characterization methods use RF data originating from backscattering processes in the insonified tissue. Characterization of the tissue of a thin layer (e.g., an artery wall) poses problems because of the small amount of data available. The tissue layer may be so thin that there are no RF data that are not...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/10/002
更新日期:1991-10-01 00:00:00
abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/12/006
更新日期:1985-12-01 00:00:00
abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/23/7479
更新日期:2014-12-07 00:00:00
abstract::Tserng and Kalhan have raised the question of the appropriate equation to use for the measurement of turnover rate in a stable-isotope study. In a comparison of glucose turnover measured with 2H-glucose and with 13C-glucose they used five apparently different equations and obtained conflicting answers. There is, howev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/30/10/013
更新日期:1985-10-01 00:00:00
abstract::Incorrect prediction of skin dose in external beam radiotherapy (EBR) can have normal tissue complication such as acute skin desquamation and skin necrosis. The absorbed dose of skin should be evaluated within basal layer, placed between the epidermis and dermis layers. However, current treatment planning systems (TPS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2ef5
更新日期:2019-08-14 00:00:00
abstract::High-resolution computations of induced fields are used to assess equivalent source levels for human exposure to uniform low-frequency electric and magnetic fields. These results pertain to 60 Hz foot-to-head electric excitation of the body in three positions with respect to a ground plane, and to magnetic excitation ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/12/001
更新日期:1997-12-01 00:00:00
abstract::For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/2/008
更新日期:1999-02-01 00:00:00
abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/1/90
更新日期:2016-01-07 00:00:00
abstract::The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been develo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/10/019
更新日期:2007-05-21 00:00:00
abstract::The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues beco...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/17/014
更新日期:2011-09-07 00:00:00
abstract::In positron emission tomography (PET), there is an increasing interest in studying not only the regional mean tracer concentration, but its variation arising from local differences in physiology, the tissue heterogeneity. However, in reconstructed images this physiological variation is shadowed by a large reconstructi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/14/4849
更新日期:2013-07-21 00:00:00
abstract::We investigate the effect of multiple scattering on the optical coherence tomography (OCT) signal and the Doppler OCT signal of flowing blood. Doppler OCT measurements at 1300 nm are performed on flowing diluted porcine blood with hematocrit ranging between 0% and 15%. Measured blood hematocrit and mean red blood cell...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/7/1907
更新日期:2012-04-07 00:00:00
abstract::Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/14/003
更新日期:2011-07-21 00:00:00
abstract::Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/20/003
更新日期:2010-10-21 00:00:00
abstract::Diffuse optical imaging using non-ionizing radiation is a non-invasive method that shows promise towards breast cancer diagnosis. Hand-held optical imagers show potential for clinical translation of the technology, yet they have not been used towards 3D tomography. Herein, 3D tomography of human breast tissue in vivo ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/5/1563
更新日期:2013-03-07 00:00:00
abstract::Mechanical properties of biological tissues are significant biomarkers for diagnosing various diseases. Assessing the viscoelastic properties of multi-layer tissues has remained challenging for a long time. Some shear wave models have been proposed to estimate thin-layer tissues' viscoelasticity recently. However, the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abca04
更新日期:2020-11-12 00:00:00
abstract::The established theory for the collection efficiency of an ionisation chamber irradiated by a series of uniform short pulses is extended to the more complex case of irradiation in a pulsed and electromagnetically swept electron beam. The radial variation of exposure rate is assumed to be Gaussian with scale constant e...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/27/2/001
更新日期:1982-02-01 00:00:00
abstract::An efficient registration strategy is described that aims to help solve delicate medical imaging registration problems. It consists of running several registration methods for each dataset and selecting the best one for each specific dataset, according to an evaluation criterion. Finally, the quality of the registrati...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/22/6997
更新日期:2014-11-21 00:00:00
abstract::Boundary element methods (BEM) are used for forward computation of bioelectromagnetic fields in multi-compartment volume conductor models. Most BEM approaches assume that each compartment is in contact with at most one external compartment. In this work, I present a general surface integral equation and BEM discretiza...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/22/N606
更新日期:2016-11-21 00:00:00
abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac4f2
更新日期:2018-06-07 00:00:00
abstract::Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/1/195
更新日期:2015-01-07 00:00:00
abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/5/007
更新日期:2004-03-07 00:00:00