Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis.

Abstract:

:Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.

journal_name

Phys Med Biol

authors

Monnin P,Marshall NW,Bosmans H,Bochud FO,Verdun FR

doi

10.1088/0031-9155/56/14/003

subject

Has Abstract

pub_date

2011-07-21 00:00:00

pages

4221-38

issue

14

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)86253-0

journal_volume

56

pub_type

杂志文章
  • Factorial phase imaging: a new concept in the analysis of first-pass cardiac studies.

    abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/10/007

    authors: Houston AS,Elliott AT,Stone DL

    更新日期:1982-10-01 00:00:00

  • Impact of high dose volumetric CT on PTV margin reduction in VMAT prostate radiotherapy.

    abstract::The aim of the study is to determine PTV margin for inter-observer variability in the volumetric modulated arc therapy (VMAT) prostate radiotherapy with high-dose volumetric CT (HDVCT) and conventional helical CT (CCT) for planning. Secondly to investigate the impact of geometric (PTV expansion) and dosimetric (confor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab050f

    authors: Cho YB,Alasti H,Kong V,Catton C,Berlin A,Chung P,Bayley A,Jaffray D

    更新日期:2019-03-14 00:00:00

  • Reducing scan angle using adaptive prior knowledge for a limited-angle intrafraction verification (LIVE) system for conformal arc radiotherapy.

    abstract::The purpose of this study is to develop an adaptive prior knowledge guided image estimation technique to reduce the scan angle needed in the limited-angle intrafraction verification (LIVE) system for 4D-CBCT reconstruction. The LIVE system has been previously developed to reconstruct 4D volumetric images on-the-fly du...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6913

    authors: Zhang Y,Yin FF,Zhang Y,Ren L

    更新日期:2017-05-07 00:00:00

  • A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.

    abstract::A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/020

    authors: Asuni G,Jensen JM,McCurdy BM

    更新日期:2011-02-21 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • The dosimetry for a coronary artery stent coated with radioactive 188Re and 32P.

    abstract::Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/310

    authors: Fox RA,Henson PW

    更新日期:2000-12-01 00:00:00

  • Analytical description of dose profile behaviour in Gamma Knife radiosurgery.

    abstract::Stereotactic Gamma Knife radiosurgery utilizes ionizing beams from (60)Co sources and relies on a combination of collimator sizes, weighting, etc to generate a high-dose region that is conformal with a designated target volume. Dose computation is typically performed by computer, but in this paper, single collimator d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/003

    authors: Fenner J,Gwilliam M,Mehrem R,Bird A,Walton L

    更新日期:2008-04-21 00:00:00

  • Correction of proton resonance frequency shift temperature maps for magnetic field disturbances caused by breathing.

    abstract::Respiratory induced resonance offset (RIRO) is a periodic disturbance of a magnetic field due to breathing. Such disturbance handicaps the accuracy of the proton resonance frequency shift (PRFS) method of MRI temperature mapping in anatomies situated nearby the lungs and chest wall. In this work, we propose a method c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/18/015

    authors: Shmatukha AV,Bakker CJ

    更新日期:2006-09-21 00:00:00

  • Effective dose conversion coefficient for gamma ray exposure from an overhead plume.

    abstract::The external radiation exposure from an overhead plume containing gamma emitting radionuclides can contribute substantial dose to the ground receptor during normal operations as well as accidental release conditions of nuclear facilities. In order to estimate the effective dose conversion coefficients (DCCs) directly,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2c92

    authors: Dey R,Patni HK,Deo Singh K,Kulkarni MS,Anand S

    更新日期:2019-08-01 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • The transformation method for the MIRD absorbed fraction as applied to various physiques.

    abstract::A transformation method was investigated for applying the MIRD absorbed fraction to internal dose calculations for an individual. The transformation method consists of two parts, transformation of the target organ mass, and of the distance between source and target organs. The variation of the specific absorbed fracti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/4/006

    authors: Yamaguchi H,Kato Y,Shiragai A

    更新日期:1975-07-01 00:00:00

  • Real-time prediction and gating of respiratory motion using an extended Kalman filter and Gaussian process regression.

    abstract::Motion-adaptive radiotherapy aims to deliver a conformal dose to the target tumour with minimal normal tissue exposure by compensating for tumour motion in real time. The prediction as well as the gating of respiratory motion have received much attention over the last two decades for reducing the targeting error of th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/233

    authors: Bukhari W,Hong SM

    更新日期:2015-01-07 00:00:00

  • Response, thermal regulatory threshold and thermal breakdown threshold of restrained RF-exposed mice at 905 MHz.

    abstract::The objective of this study was the determination of the thermal regulatory and the thermal breakdown thresholds for in-tube restrained B6C3F1 and NMRI mice exposed to radiofrequency electromagnetic fields at 905 MHz. Different levels of the whole-body averaged specific absorption rate (SAR = 0, 2, 5, 7.2, 10, 12.6 an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/017

    authors: Ebert S,Eom SJ,Schuderer J,Apostel U,Tillmann T,Dasenbrock C,Kuster N

    更新日期:2005-11-07 00:00:00

  • Electron depth-dose dependence on energy spectral quality.

    abstract::Electron depth-dose curves and spectra have been measured from an experimental accelerator on which both energy and spectral shape could be varied independently. The measurements were made at nominal energies of 6 and 12 MeV, with the energy spread (FWHM) varied from 1.7% to over 10% of average energy. Changes in dept...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/005

    authors: Johnsen SW,LaRiviere PD,Tanabe E

    更新日期:1983-12-01 00:00:00

  • On the correction, perturbation and modification of small field detectors in relative dosimetry.

    abstract::The purpose of this study was to derive a complete set of correction and perturbation factors for output factors (OF) and dose profiles. Modern small field detectors were investigated including a plastic scintillator (Exradin W1, SI), a liquid ionization chamber (microLion 31018, PTW), an unshielded diode (Exradin D1V...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5937

    authors: Papaconstadopoulos P,Tessier F,Seuntjens J

    更新日期:2014-10-07 00:00:00

  • Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods.

    abstract::The High-Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography (PET) scanner. Recently, a 3D filtered backprojection (3D-FBP) reconstruction method has been implemented to reduce bias in short duration frames, currently observed in 3D ordinary Poisson OSEM (3D-OP-OSEM) reconstruc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/12/010

    authors: van Velden FH,Kloet RW,van Berckel BN,Wolfensberger SP,Lammertsma AA,Boellaard R

    更新日期:2008-06-21 00:00:00

  • Computational dosimetry for grounded and ungrounded human models due to contact current.

    abstract::This study presents the computational dosimetry of contact currents for grounded and ungrounded human models. The uncertainty of the quasi-static (QS) approximation of the in situ electric field induced in a grounded/ungrounded human body due to the contact current is first estimated. Different scenarios of cylindrica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/15/5153

    authors: Chan KH,Hattori J,Laakso I,Hirata A,Taki M

    更新日期:2013-08-07 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Robust treatment planning with 4D intensity modulated carbon ion therapy for multiple targets in stage IV non-small cell lung cancer.

    abstract::Intensity modulated particle therapy (IMPT) with carbon ions can generate highly conformal treatment plans; however, IMPT is limited in robustness against range and positioning uncertainty. This is particularly true for moving targets, even though all motion states of a 4DCT are considered in 4D-IMPT. Here, we expand ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba1a3

    authors: Wolf M,Anderle K,Durante M,Graeff C

    更新日期:2020-11-06 00:00:00

  • Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems.

    abstract::Radiographic imaging of large patients is compromised by x-ray scatter. Optimization of digital x-ray imaging systems used for projection radiography requires the use of the best possible antiscatter grid. The performance of antiscatter grids used in conjunction with digital x-ray imaging systems can be characterized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/010

    authors: Fetterly KA,Schueler BA

    更新日期:2007-08-21 00:00:00

  • An alternative to gamma histograms for ROI-based quantitative dose comparisons.

    abstract::An alternative to gamma (gamma) histograms for ROI-based quantitative comparisons of dose distributions using the gamma concept is proposed. The method provides minimum values of dose difference and distance-to-agreement such that a pre-set fraction of the region of interest passes the gamma test. Compared to standard...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N03

    authors: Dvorak P

    更新日期:2009-06-21 00:00:00

  • Investigating the robustness of ion beam therapy treatment plans to uncertainties in biological treatment parameters.

    abstract::Uncertainties in determining clinically used relative biological effectiveness (RBE) values for ion beam therapy carry the risk of absolute and relative misestimations of RBE-weighted doses for clinical scenarios. This study assesses the consequences of hypothetical misestimations of input parameters to the RBE modell...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/7983

    authors: Böhlen TT,Brons S,Dosanjh M,Ferrari A,Fossati P,Haberer T,Patera V,Mairani A

    更新日期:2012-12-07 00:00:00

  • Iterative image-domain ring artifact removal in cone-beam CT.

    abstract::Ring artifacts in cone beam computed tomography (CBCT) images are caused by pixel gain variations using flat-panel detectors, and may lead to structured non-uniformities and deterioration of image quality. The purpose of this study is to propose a method of general ring artifact removal in CBCT images. This method is ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7017

    authors: Liang X,Zhang Z,Niu T,Yu S,Wu S,Li Z,Zhang H,Xie Y

    更新日期:2017-07-07 00:00:00

  • A water calorimeter for neutron dosimetry.

    abstract::A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/005

    authors: Galloway G,Greening JR,Williams JR

    更新日期:1986-04-01 00:00:00

  • Radio-enhancement by gold nanoparticles and their impact on water radiolysis for x-ray, proton and carbon-ion beams.

    abstract::Gold nanoparticle (GNP) radio-enhancement is a promising technique to increase the dose deposition in a tumor while sparing neighboring healthy tissue. Previous experimental studies showed effects on cell survival and tumor control for keV x-rays but surprisingly also for MV-photons, proton and carbon-ion beams. In a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab314c

    authors: Rudek B,McNamara A,Ramos-Méndez J,Byrne H,Kuncic Z,Schuemann J

    更新日期:2019-08-28 00:00:00

  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • Experimental verification of numerical simulations of cryosurgery with application to computerized planning.

    abstract::As a part of an ongoing effort to develop computerized planning tools for cryosurgery, an experimental study has been conducted to verify a recently developed numerical technique for bioheat transfer simulations. Experiments were performed on gelatin solution as a phantom material, using proprietary liquid-nitrogen cr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/15/013

    authors: Rossi MR,Rabin Y

    更新日期:2007-08-07 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00

  • The use of the Henyey-Greenstein phase function in Monte Carlo simulations in biomedical optics.

    abstract::Monte Carlo (MC) simulations are often at the heart of the testing procedure in biomedical optics. One of the critical points in MC simulations is to define the new photon direction after each scattering event. One of the most popular solutions is to use the Henyey-Greenstein phase function or some linear combinations...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/17/N04

    authors: Binzoni T,Leung TS,Gandjbakhche AH,Rüfenacht D,Delpy DT

    更新日期:2006-09-07 00:00:00

  • Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis.

    abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/671

    authors: Li Q,Gavrielides MA,Zeng R,Myers KJ,Sahiner B,Petrick N

    更新日期:2015-01-21 00:00:00