Abstract:
:Gold nanoparticle (GNP) radio-enhancement is a promising technique to increase the dose deposition in a tumor while sparing neighboring healthy tissue. Previous experimental studies showed effects on cell survival and tumor control for keV x-rays but surprisingly also for MV-photons, proton and carbon-ion beams. In a systematic study, we use the Monte Carlo simulation tool TOPAS-nBio to model the GNP radio-enhancement within a cell as a function of GNP concentration, size and clustering for a wide range of energies for photons, protons and, for the first time, carbon-ions. Moreover, we include water radiolysis, which has been recognized as a major pathway of GNP mediated radio-enhancement. At a GNP concentration of 0.5% and a GNP diameter of 10 nm, the dose enhancement ratio was highest for 50 keV x-rays (1.36) and decreased in the orthovoltage (1.04 at 250 keV) and megavoltage range (1.01 at 1 MeV). The dose enhancement linearly increased with GNP concentration and decreased with GNP size and degree of clustering for all radiation modalities. While the highest physical dose enhancement at 5% concentrations was only 1.003 for 10 MeV protons and 1.004 for 100 MeV carbon-ions, we find the number of hydroxyl ([Formula: see text]) altered by 23% and 3% after 1 [Formula: see text]s at low, clinically-relevant concentrations. For the same concentration and proton-impact, the G-value is most sensitive to the nanoparticle size with 46 times more radical interactions at GNPs for 2 nm than for 50 nm GNP diameter within 1 [Formula: see text]s. Nanoparticle clustering was found to decrease the number of interactions at GNPs, e.g. for a cluster of 25 GNPs by a factor of 3.4. The changes in G-value correlate to the average distance between the chemical species and the GNPs. While the radiochemistry of GNP-loaded water has yet to be fully understood, this work offers a first relative quantification of radiolysis products for a broad parameter-set.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Rudek B,McNamara A,Ramos-Méndez J,Byrne H,Kuncic Z,Schuemann Jdoi
10.1088/1361-6560/ab314csubject
Has Abstractpub_date
2019-08-28 00:00:00pages
175005issue
17eissn
0031-9155issn
1361-6560journal_volume
64pub_type
杂志文章abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab13f2
更新日期:2019-04-23 00:00:00
abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/24/004
更新日期:2003-12-21 00:00:00
abstract::A 3D anatomical computational model is developed to assess thermal effects due to exposure to the electromagnetic field required to power a new investigational active implantable microvalve for the treatment of glaucoma. Such a device, located in the temporal superior eye quadrant, produces a filtering bleb, which is ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5dae
更新日期:2017-05-07 00:00:00
abstract::The National Physical Laboratory (NPL) provides a high-energy photon calibration service using 4-19 MV x-rays and 60Co gamma-radiation for secondary standard dosemeters in terms of absorbed dose to water. The primary standard used for this service is a graphite calorimeter and so absorbed dose calibrations must be con...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/3/306
更新日期:2002-02-07 00:00:00
abstract::Users of nuclear and atomic data for biomedical purposes often have difficulty in identifying the most up-to-date and appropriate sources of such data. The biomedical Subcommittee of the UK Nuclear Data Committee have prepared a list of recommended data sources available at the beginning of 1978 on radioactive decay s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/1/001
更新日期:1979-01-01 00:00:00
abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/N241
更新日期:2015-06-21 00:00:00
abstract::The presence of motion artifacts is a typical problem in thoracic imaging. However, synchronizing the respiratory cycle with computed tomography (CT) image acquisition can reduce these artifacts. We currently employ a method of in vivo respiratory-gated micro-CT imaging for small laboratory animals (mice). This proced...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/17/023
更新日期:2004-09-07 00:00:00
abstract::It seems likely that long term patency of small bore vascular prostheses is dependent upon, among other things, the mechanical properties of their walls. Arteries are visco-elastic but there is no accurate method of measuring the visco-elasticity of arterial substitutes in vivo. The most successful vascular substitute...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/28/9/006
更新日期:1983-09-01 00:00:00
abstract::Accumulating evidence shows that hyperthermia improves head-and-neck cancer treatment. Over the last decade, we introduced a radiofrequency applicator, named HYPERcollar, which enables local heating also of deep locations in this region. Based on clinical experience, we redesigned the HYPERcollar for improved comfort,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/17/5997
更新日期:2013-09-07 00:00:00
abstract::In carbon ion therapy treatment planning, the relative biological effectiveness (RBE) is accounted for by optimization of the RBE-weighted dose (biological dose). The RBE calculation methods currently applied clinically in carbon ion therapy are derived from the microdosimetric kinetic model (MKM) in Japan and the loc...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aae8b4
更新日期:2018-11-12 00:00:00
abstract::This study investigates the dosimetric impact of using population-based Hounsfield units (HUs) and ICRU-based HUs as a function of the number of tissue segments for bulk density assignment toward MRI-based treatment planning in the abdomen. To avoid potential geometric differences between CT and MR images, CT images r...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aacfb1
更新日期:2018-07-24 00:00:00
abstract::Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/42/2/010
更新日期:1997-02-01 00:00:00
abstract::This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SS...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/24/8119
更新日期:2012-12-21 00:00:00
abstract::Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/51/14/R01
更新日期:2006-07-21 00:00:00
abstract::Pulsed nuclear magnetic resonance imaging (NMRI) apparatus has developed very quickly. On the other hand, the development of apparatus for pulsed electron paramagnetic resonance imaging (EPRI) has been very slow. This fact is due to the extremely reduced relaxation times of the paramagnetic probes. EPR linewidths are ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/6/409
更新日期:1999-06-01 00:00:00
abstract::Correct classification of cystoscopy images depends on the interpreter's experience. Bladder cancer is a common lesion that can only be confirmed by biopsying the tissue, therefore, the automatic identification of tumors plays a significant role in early stage diagnosis and its accuracy. To our best knowledge, the use...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaa3af
更新日期:2018-02-02 00:00:00
abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...
journal_title:Physics in medicine and biology
pub_type: 评论,杂志文章
doi:10.1088/1361-6560/aae0e4
更新日期:2018-10-03 00:00:00
abstract::Voltage-sensitive dyes are an important tool in visualizing electrical activity in cardiac tissue. Until today, they have mainly been applied in cardiac electrophysiology to subsurface imaging. In the present study, we assess different imaging methods used in optical tomography with respect to their effectiveness in v...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/2/003
更新日期:2005-01-21 00:00:00
abstract::Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/6/006
更新日期:2008-03-21 00:00:00
abstract::Three major linear accelerator vendors offer gantry-mounted single (monoscopic) x-ray imagers. The use of monoscopic imaging to estimate three-dimensional (3D) target positions has not been fully explored. The purpose of this work is to develop and investigate a robust monoscopic method for real-time tumour tracking, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/11/006
更新日期:2008-06-07 00:00:00
abstract::This study aims to build a feasible mathematical model to analyze the mass evolution of NSCLC during standard fractionated radiotherapy. Seventy-three cases of NSCLC who were received radiotherapy with prescription dose of 2 Gy × 30 fx were selected retrospectively and divided into adenocarcinoma (ADC) group and squ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab47c0
更新日期:2019-11-26 00:00:00
abstract::Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its hea...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/22/010
更新日期:2006-11-21 00:00:00
abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/4/005
更新日期:1979-07-01 00:00:00
abstract::The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to 100 GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication. For the calculation, the radiation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/7/009
更新日期:2009-04-07 00:00:00
abstract::A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/9/005
更新日期:1994-09-01 00:00:00
abstract::Heavy-ion radiotherapy exploits the high biological effectiveness of localized energy deposition delivered by so-called Bragg-peak particles. Recent publications have challenged the established procedures to calculate biological effective dose distributions in treatment planning. They emphasize the importance of very ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/7/N03
更新日期:2009-04-07 00:00:00
abstract::Monte Carlo-based simulation of positron emission tomography (PET) data plays a key role in the design and optimization of data correction and processing methods. Our first aim was to adapt and configure the PET-SORTEO Monte Carlo simulation program for the geometry of the widely distributed Inveon PET preclinical sca...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/19/6749
更新日期:2013-10-07 00:00:00
abstract::Non-invasive evaluation of the Achilles tendon elastic properties may enhance diagnosis of tendon injury and the assessment of recovery treatments. Shear wave elastography has shown to be a powerful tool to estimate tissue mechanical properties. However, its applicability to quantitatively evaluate tendon stiffness is...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/3/505
更新日期:2014-02-07 00:00:00
abstract::A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed metho...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abac9d
更新日期:2020-11-17 00:00:00
abstract::For low-energy (up to 150 kV) x-rays, the ratio of mass-energy absorption coefficients for water to air, (mu(en)/rho)w.air, and the backscatter factor B are used in the conversion of air kerma, measured free-in-air, to water kerma on the surface of a water phantom. For clinical radiotherapy, similar conversion factors...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/1/011
更新日期:1999-01-01 00:00:00