Pulsed EPR imaging: image reconstruction using selective acquisition sequences.

Abstract:

:Pulsed nuclear magnetic resonance imaging (NMRI) apparatus has developed very quickly. On the other hand, the development of apparatus for pulsed electron paramagnetic resonance imaging (EPRI) has been very slow. This fact is due to the extremely reduced relaxation times of the paramagnetic probes. EPR linewidths are larger than typical NMR linewidths. These large linewidths are also responsible for a substantial worsening of spatial resolution. Due to the brevity of the electronic relaxation times, not all the acquisition/reconstruction techniques currently used in NMRI (such as spin-echo, gradient-echo, etc) can be applied in pulsed EPRI. In fact, the usable sequences in pulsed EPRI are only acquisitions from projections, where it is possible to use stationary magnetic field gradients. Moreover, the use of high fixed magnetic field gradients induces a short decay time constant T2*. The low T2* value can make it impossible for the analogue to digital conversion system (ADC) to reproduce signal variations during the whole acquisition interval and the resolution can worsen. A new pulsed EPRI acquisition sequence from projections, based on selective reception, is presented that is particularly useful in solving the problems of worsening of spatial resolution associated with the use of an ADC. In order to demonstrate the capabilities of our acquisition method, simulated numerical tests will also be reported.

journal_name

Phys Med Biol

authors

Di Giuseppe S,Placidi G,Brivati JA,Alecci M,Sotgiu A

doi

10.1088/0031-9155/44/6/409

subject

Has Abstract

pub_date

1999-06-01 00:00:00

pages

N137-44

issue

6

eissn

0031-9155

issn

1361-6560

journal_volume

44

pub_type

杂志文章
  • Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams.

    abstract::The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three dimensional treatment planning system (Helax-TMS,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/302

    authors: Russell KR,Isacsson U,Saxner M,Ahnesjö A,Montelius A,Grusell E,Dahlgren CV,Lorin S,Glimelius B

    更新日期:2000-01-01 00:00:00

  • On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution.

    abstract::The performance of a light sharing and recirculation mechanism that allows the extraction of depth of interaction (DOI) are investigated in this paper, with a particular focus on timing. In parallel, a method to optimize the coincidence time resolution (CTR) of PET detectors by use of the DOI information is proposed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2cb0

    authors: Pizzichemi M,Polesel A,Stringhini G,Gundacker S,Lecoq P,Tavernier S,Paganoni M,Auffray E

    更新日期:2019-08-07 00:00:00

  • 3D radiotherapy dose prediction on head and neck cancer patients with a hierarchically densely connected U-net deep learning architecture.

    abstract::The treatment planning process for patients with head and neck (H&N) cancer is regarded as one of the most complicated due to large target volume, multiple prescription dose levels, and many radiation-sensitive critical structures near the target. Treatment planning for this site requires a high level of human experti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab039b

    authors: Nguyen D,Jia X,Sher D,Lin MH,Iqbal Z,Liu H,Jiang S

    更新日期:2019-03-18 00:00:00

  • Effect of material property heterogeneity on biomechanical modeling of prostate under deformation.

    abstract::Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/195

    authors: Samavati N,McGrath DM,Jewett MA,van der Kwast T,Ménard C,Brock KK

    更新日期:2015-01-07 00:00:00

  • Scanned proton radiotherapy for mobile targets-the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.

    abstract::The most advanced delivery technique for proton radiotherapy is active spot scanning. So far, predominantly static targets have been treated with active spot scanning, since mobile targets in combination with dynamic treatment delivery can lead to interplay effects, causing inhomogeneous dose distributions. One way to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/22/016

    authors: Knopf AC,Hong TS,Lomax A

    更新日期:2011-11-21 00:00:00

  • Monitoring the irradiation field of 12C and 16O SOBP beams using positron emitters produced through projectile fragmentation reactions.

    abstract::In order to effectively utilize the prominent properties of heavy ions in radiotherapy, it is important to evaluate both the position of the field irradiated with incident ions and the absorbed dose distribution in a patient's body. One of the methods for this purpose is the utilization of the positron emitters produc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/002

    authors: Inaniwa T,Kohno T,Tomitani T,Sato S

    更新日期:2008-02-07 00:00:00

  • Dosimetric accuracy of planning and delivering small proton therapy fields.

    abstract::A detailed Monte Carlo model of a proton therapy treatment head was commissioned to simulate the delivery of small field proton treatments. Small fields are challenging in the planning and quality assurance process because of aperture scattering and dosimetric disequilibrium. Four patients with small fields used in al...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/003

    authors: Bednarz B,Daartz J,Paganetti H

    更新日期:2010-12-21 00:00:00

  • Comparison of in vivo scintillation probes and gamma cameras for detection of small, deep tumours.

    abstract::An in vivo probe was compared with a gamma camera for the task of detecting radiolabelled tumour models in a water phantom. The probe, which contained a 1 cm diameter NaI(T1) detector, was designed and used by us for surgical staging studies of gynaecological patients. Tumours were spherical sources of different sizes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/6/008

    authors: Barber HB,Barrett HH,Woolfenden JM,Myers KJ,Hickernell TS

    更新日期:1989-06-01 00:00:00

  • Detection of in situ mammary cancer in a transgenic mouse model: in vitro and in vivo MRI studies demonstrate histopathologic correlation.

    abstract::Improving the prevention and detection of preinvasive ductal carcinoma in situ (DCIS) is expected to lower both morbidity and mortality from breast cancer. Transgenic mouse models can be used as a 'test bed' to develop new imaging methods and to evaluate the efficacy of candidate preventive therapies. We hypothesized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/014

    authors: Jansen SA,Conzen SD,Fan X,Krausz T,Zamora M,Foxley S,River J,Newstead GM,Karczmar GS

    更新日期:2008-10-07 00:00:00

  • The dosimetry for a coronary artery stent coated with radioactive 188Re and 32P.

    abstract::Radiation dose distributions have been calculated for 188Re and 32P activity on a coronary artery stent. The doses have been calculated both as a function of position along the stent and of depth into the artery wall. Comparisons of the dose from identical activities of 188Re and 32P on the stent show that the major d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/310

    authors: Fox RA,Henson PW

    更新日期:2000-12-01 00:00:00

  • Brachytherapy technology and physics practice since 1950: a half-century of progress.

    abstract::The 50-year tenure of Physics in Medicine and Biology has coincided with some of the most important developments in radiological science, including the introduction of artificial radioactivity, computers and 3D imaging into medicine. These events have profoundly influenced the development of brachytherapy. Although it...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R18

    authors: Williamson JF

    更新日期:2006-07-07 00:00:00

  • Quantitative analysis of a micro array anode structured target for hard x-ray grating interferometry.

    abstract::Talbot-Lau interferometry (TLI) provides additional contrast modes for x-ray imaging that are complementary to conventional absorption radiography. TLI is particularly interesting because it is one of the few practical methods for realizing phase contrast with x-rays that is compatible with large-spot high power x-ray...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab6578

    authors: Zan G,Vine DJ,Yun W,Lewis SJY,Wang Q,Wang G

    更新日期:2020-02-04 00:00:00

  • Extended three-compartment model for the transport and distribution of Hippuran.

    abstract::The distribution and transport of Hippuran is discussed. The activity leaving both kidneys has been calculated and compared with the bladder activity. It is shown that the Impulse Response Function of the ureter and bladder may be obtained by deconvolution, and data are presented relating to studies on one patient. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/2/002

    authors: Knesaurek K,Spaventi S

    更新日期:1981-03-01 00:00:00

  • Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

    abstract::In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6571

    authors: Roncali E,Phipps JE,Marcu L,Cherry SR

    更新日期:2012-10-21 00:00:00

  • Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment.

    abstract::Fast heat extraction is critically important to obtain the maximal benefit of cryogen spray cooling (CSC) during laser therapy of shallow skin lesions, such as port wine stain birthmarks. However, a film of liquid cryogen can build up on the skin surface, impairing heat transfer due to the relatively low thermal condu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/301

    authors: Majaron B,Svaasand LO,Aguilar G,Nelson JS

    更新日期:2002-09-21 00:00:00

  • A limited-angle CT reconstruction method based on anisotropic TV minimization.

    abstract::This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/7/2119

    authors: Chen Z,Jin X,Li L,Wang G

    更新日期:2013-04-07 00:00:00

  • Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons-a Monte Carlo simulation study.

    abstract::We propose and evaluate the performance of an improved preclinical positron emission tomography (PET) scanner design, referred to as Polaroid-PET, consisting of a detector equipped with a layer of horizontal Polaroid to filter scintillation photons with vertical polarization. This makes it possible to improve the spat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaeb8

    authors: Sanaat A,Ashrafi-Belgabad A,Zaidi H

    更新日期:2020-12-02 00:00:00

  • Classification of movement intention by spatially filtered electromagnetic inverse solutions.

    abstract::We couple standardized low-resolution electromagnetic tomography, an inverse solution for electroencephalography (EEG) and the common spatial pattern, which is here conceived as a data-driven beamformer, to classify the benchmark BCI (brain-computer interface) competition 2003, data set IV. The data set is from an exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/8/002

    authors: Congedo M,Lotte F,Lécuyer A

    更新日期:2006-04-21 00:00:00

  • On the accuracy and effectiveness of dose reconstruction for tomotherapy.

    abstract::Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the inci...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/303

    authors: Kapatoes JM,Olivera GH,Balog JP,Keller H,Reckwerdt PJ,Mackie TR

    更新日期:2001-04-01 00:00:00

  • Monte Carlo verification of IMRT dose distributions from a commercial treatment planning optimization system.

    abstract::The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/9/303

    authors: Ma CM,Pawlicki T,Jiang SB,Li JS,Deng J,Mok E,Kapur A,Xing L,Ma L,Boyer AL

    更新日期:2000-09-01 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • An expression for backscatter factors for orthovoltage x-rays.

    abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/021

    authors: Xiao Y,Bjärngard B

    更新日期:1998-05-01 00:00:00

  • List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

    abstract::Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this wor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/17/006

    authors: Lamare F,Ledesma Carbayo MJ,Cresson T,Kontaxakis G,Santos A,Le Rest CC,Reader AJ,Visvikis D

    更新日期:2007-09-07 00:00:00

  • Pre-optimization of radiotherapy treatment planning: an artificial neural network classification aided technique.

    abstract::A method has been developed which, by using the geometric information from treatment sample cases, selects from a given data set an initial treatment plan as a step for treatment plan optimization. The method uses an artificial neural network (ANN) classification technique to select a best matching plan from the 'opti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/6/306

    authors: Hosseini-Ashrafi ME,Bagherebadian H,Yahaqi E

    更新日期:1999-06-01 00:00:00

  • Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    abstract::A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/14/5413

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJ

    更新日期:2015-07-21 00:00:00

  • A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

    abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/010

    authors: Tong S,Alessio AM,Kinahan PE,Liu H,Shi P

    更新日期:2011-04-21 00:00:00

  • Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources.

    abstract::Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides or, in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc708

    authors: Schwarz BC,Godwin WJ,Wayson MB,Dewji SA,Jokisch DW,Lee C,Bolch WE

    更新日期:2020-11-03 00:00:00

  • Online compensation for target motion with scanned particle beams: simulation environment.

    abstract::Target motion is one of the major limitations of each high precision radiation therapy. Using advanced active beam delivery techniques, such as the magnetic raster scanning system for particle irradiation, the interplay between time-dependent beam and target position heavily distorts the applied dose distribution. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/14/001

    authors: Li Q,Groezinger SO,Haberer T,Rietzel E,Kraft G

    更新日期:2004-07-21 00:00:00

  • Effects of tissue mechanical and acoustic anisotropies on the performance of a cross-correlation-based ultrasound strain imaging method.

    abstract::The anisotropic mechanical properties (mechanical anisotropy) and view-dependent ultrasonic backscattering (acoustic anisotropy) of striated muscle due to the underlying myofiber arrangement have been well documented, but whether they impact on ultrasound strain imaging (USI) techniques remains unclear. The aim of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa530b

    authors: Li H,Lee WN

    更新日期:2017-02-21 00:00:00