Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectors.

Abstract:

:In previous work we demonstrated the potential of positron emission tomography (PET) detectors with depth-of-interaction (DOI) encoding capability based on phosphor-coated crystals. A DOI resolution of 8 mm full-width at half-maximum was obtained for 20 mm long scintillator crystals using a delayed charge integration linear regression method (DCI-LR). Phosphor-coated crystals modify the pulse shape to allow continuous DOI information determination, but the relationship between pulse shape and DOI is complex. We are therefore interested in developing a sensitive and robust method to estimate the DOI. Here, linear discriminant analysis (LDA) was implemented to classify the events based on information extracted from the pulse shape. Pulses were acquired with 2×2×20 mm(3) phosphor-coated crystals at five irradiation depths and characterized by their DCI values or Laguerre coefficients. These coefficients were obtained by expanding the pulses on a Laguerre basis set and constituted a unique signature for each pulse. The DOI of individual events was predicted using LDA based on Laguerre coefficients (Laguerre-LDA) or DCI values (DCI-LDA) as discriminant features. Predicted DOIs were compared to true irradiation depths. Laguerre-LDA showed higher sensitivity and accuracy than DCI-LDA and DCI-LR and was also more robust to predict the DOI of pulses with higher statistical noise due to low light levels (interaction depths further from the photodetector face). This indicates that Laguerre-LDA may be more suitable to DOI estimation in smaller crystals where lower collected light levels are expected. This novel approach is promising for calculating DOI using pulse shape discrimination in single-ended readout depth-encoding PET detectors.

journal_name

Phys Med Biol

authors

Roncali E,Phipps JE,Marcu L,Cherry SR

doi

10.1088/0031-9155/57/20/6571

subject

Has Abstract

pub_date

2012-10-21 00:00:00

pages

6571-85

issue

20

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

    abstract::Electrical properties (EP), namely conductivity and permittivity, can provide endogenous contrast for tissue characterization. Using electrical property tomography (EPT), maps of EP can be generated from conventional MRI data. This report investigates the feasibility and accuracy of EPT at 21.1 T for multiple RF coils...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3259

    authors: Amouzandeh G,Mentink-Vigier F,Helsper S,Bagdasarian FA,Rosenberg JT,Grant SC

    更新日期:2020-02-28 00:00:00

  • Multiline 3D beamforming using micro-beamformed datasets for pediatric transesophageal echocardiography.

    abstract::Until now, no matrix transducer has been realized for 3D transesophageal echocardiography (TEE) in pediatric patients. In 3D TEE with a matrix transducer, the biggest challenges are to connect a large number of elements to a standard ultrasound system, and to achieve a high volume rate (>200 Hz). To address these issu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab45e

    authors: Bera D,Raghunathan SB,Chen C,Chen Z,Pertijs MAP,Verweij MD,Daeichin V,Vos HJ,van der Steen AFW,de Jong N,Bosch JG

    更新日期:2018-03-29 00:00:00

  • Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    abstract::Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registratio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa62c5

    authors: Uneri A,De Silva T,Goerres J,Jacobson MW,Ketcha MD,Reaungamornrat S,Kleinszig G,Vogt S,Khanna AJ,Osgood GM,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-21 00:00:00

  • An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators.

    abstract::A leaf-setting algorithm is developed for generating arbitrary beam intensity profiles in discrete levels using dynamic multileaf collimators (DMLCs). The algorithm starts with the algebraic expression for the area under the beam profile. It is shown that the coefficients in this expression can be transformed into the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/6/019

    authors: Ma L,Boyer AL,Xing L,Ma CM

    更新日期:1998-06-01 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Photothermal effects of laser tissue soldering.

    abstract::Low-strength anastomoses and thermal damage of tissue are major concerns in laser tissue welding techniques where laser energy is used to induce thermal changes in the molecular structure of the tissues being joined, hence allowing them to bond together. Laser tissue soldering, on the other hand, is a bonding techniqu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/4/013

    authors: McNally KM,Sorg BS,Welch AJ,Dawes JM,Owen ER

    更新日期:1999-04-01 00:00:00

  • Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection.

    abstract::Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/15/014

    authors: Cassola VF,Kramer R,Brayner C,Khoury HJ

    更新日期:2010-08-07 00:00:00

  • Low density contrast agents for x-ray phase contrast imaging: the use of ambient air for x-ray angiography of excised murine liver tissue.

    abstract::We report a new preparative method for providing contrast through reduction in electron density that is uniquely suited for propagation-based differential x-ray phase contrast imaging. The method, which results in an air or fluid filled vasculature, makes possible visualization of the smallest microvessels, roughly do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/017

    authors: Laperle CM,Hamilton TJ,Wintermeyer P,Walker EJ,Shi D,Anastasio MA,Derdak Z,Wands JR,Diebold G,Rose-Petruck C

    更新日期:2008-12-07 00:00:00

  • Intensity modulated radiation therapy for oropharyngeal cancer: the sensitivity of plan objectives and constraints to set-up uncertainty.

    abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/15/003

    authors: Ploquin N,Song W,Lau H,Dunscombe P

    更新日期:2005-08-07 00:00:00

  • Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo.

    abstract::Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim o...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/18/001

    authors: Kolen AF,Miller NR,Ahmed EE,Bamber JC

    更新日期:2004-09-21 00:00:00

  • Three-dimensional performance of a small-diameter positron emission tomograph.

    abstract::Recently, the initial 2D physical characterization of a small-diameter positron emission tomograph, designed specifically for scanning of small laboratory animals, was reported. The physical characteristics of the tomograph operating in 3D mode have now been measured and compared to those obtained in 2D mode. In 3D, t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/2/010

    authors: Bloomfield PM,Myers R,Hume SP,Spinks TJ,Lammertsma AA,Jones T

    更新日期:1997-02-01 00:00:00

  • Shear wave elastography plaque characterization with mechanical testing validation: a phantom study.

    abstract::Determining plaque vulnerability is critical when selecting the most suitable treatment for patients with atherosclerotic plaque. Currently, clinical non-invasive ultrasound-based methods for plaque characterization are limited to visual assessment of plaque morphology and new quantitative methods are needed. In this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/8/3151

    authors: Widman E,Maksuti E,Larsson D,Urban MW,Bjällmark A,Larsson M

    更新日期:2015-04-21 00:00:00

  • High-energy x-ray Talbot-Lau radiography of a human knee.

    abstract::We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. I...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa7721

    authors: Horn F,Gelse K,Jabari S,Hauke C,Kaeppler S,Ludwig V,Meyer P,Michel T,Mohr J,Pelzer G,Rieger J,Riess C,Seifert M,Anton G

    更新日期:2017-08-01 00:00:00

  • A complete distortion correction for MR images: II. Rectification of static-field inhomogeneities by similarity-based profile mapping.

    abstract::Radiotherapy treatment planning relies on the use of geometrically correct images. This paper presents a fully automatic tool for correcting MR images for the effects of B(0) inhomogeneities. The post-processing method is based on the gradient-reversal technique of Chang and Fitzpatrick (1992 IEEE Trans. Med. Imaging ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/014

    authors: Reinsberg SA,Doran SJ,Charles-Edwards EM,Leach MO

    更新日期:2005-06-07 00:00:00

  • Estimation of tissue resistivities from multiple-electrode impedance measurements.

    abstract::In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/001

    authors: Eyüboğlu BM,Pilkington TC,Wolf PD

    更新日期:1994-01-01 00:00:00

  • Optimization of the artificial urinary sphincter: modelling and experimental validation.

    abstract::The artificial urinary sphincter should be long enough to prevent strangulation effects of the urethral tissue and short enough to avoid the improper dissection of the surrounding tissue. To optimize the sphincter length, the empirical three-parameter urethra compression model is proposed based on the mechanical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/023

    authors: Marti F,Leippold T,John H,Blunschi N,Müller B

    更新日期:2006-03-07 00:00:00

  • 4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

    abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0d50

    authors: Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

    更新日期:2019-05-02 00:00:00

  • Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

    abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4635

    authors: Nemallapudi MV,Gundacker S,Lecoq P,Auffray E,Ferri A,Gola A,Piemonte C

    更新日期:2015-06-21 00:00:00

  • A comparison of direct reconstruction algorithms in proton computed tomography.

    abstract::Several direct algorithms have been proposed to take into account the non-linear path of protons in the reconstruction of a proton CT (pCT) image. This paper presents a comparison between five of them, in terms of spatial resolution and relative stopping power (RSP) accuracy. Our comparison includes (1) a distance-dri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d53

    authors: Khellaf F,Krah N,Létang JM,Collins-Fekete CA,Rit S

    更新日期:2020-06-01 00:00:00

  • Measurement of image contrast using diffraction enhanced imaging.

    abstract::Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Defa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/3/304

    authors: Kiss MZ,Sayers DE,Zhong Z

    更新日期:2003-02-07 00:00:00

  • Simulation of small-angle x-ray scattering from collagen fibrils and comparison with experimental patterns.

    abstract::Simulation of small-angle x-ray scattering from collagen in healthy and cancerous breast tissue may reveal detailed information on the structural changes in collagen. Collagen fibril is modelled as a cylinder with axially periodic step-function electron density, and packing is approximated by placing the cylinders in ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/012

    authors: Suhonen H,Fernández M,Serimaa R,Suortti P

    更新日期:2005-11-21 00:00:00

  • A breathing thorax phantom with independently programmable 6D tumour motion for dosimetric measurements in radiation therapy.

    abstract::Irradiation of moving targets using a scanned ion beam can cause clinically intolerable under- and overdosages within the target volume due to the interplay effect. Several motion mitigation techniques such as gating, beam tracking and rescanning are currently investigated to overcome this restriction. To enable detai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/8/2235

    authors: Steidl P,Richter D,Schuy C,Schubert E,Haberer T,Durante M,Bert C

    更新日期:2012-04-21 00:00:00

  • Analysis of a large number of clinical studies for breast cancer radiotherapy: estimation of radiobiological parameters for treatment planning.

    abstract::Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on emp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,meta分析

    doi:10.1088/0031-9155/48/20/004

    authors: Guerrero M,Li XA

    更新日期:2003-10-21 00:00:00

  • Monte Carlo calculation of VMAT and helical tomotherapy dose distributions for lung stereotactic treatments with intra-fraction motion.

    abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2807

    authors: Belec J,Clark BG

    更新日期:2013-05-07 00:00:00

  • The use of customized spreadsheets in radiation therapy.

    abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/6/007

    authors: Balog JP,Sibata CH,Podgorsak MB,Shin KH

    更新日期:1995-06-01 00:00:00

  • An integrated platform for image-guided cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/10/2953

    authors: Ma YL,Shetty AK,Duckett S,Etyngier P,Gijsbers G,Bullens R,Schaeffter T,Razavi R,Rinaldi CA,Rhode KS

    更新日期:2012-05-21 00:00:00

  • Microwave thermal ablation using CT-scanner for predicting the variation of ablated region over time: advantages and limitations.

    abstract::This study aims at investigating in real-time the structural and dynamical changes occurring in an ex vivo tissue during a microwave thermal ablation (MTA) procedure. The experimental set-up was based on ex vivo liver tissue inserted in a dedicated box, in which 3 fibre-optic (FO) temperature probes were introduced to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1a67

    authors: Strigari L,Minosse S,D'Alessio D,Farina L,Cavagnaro M,Cassano B,Pinto R,Vallati G,Lopresto V

    更新日期:2019-05-31 00:00:00

  • Dosimetry system for the irradiation of thin biological samples with therapeutic proton beams.

    abstract::The design and performance of a dosimetric system for the irradiation of thin biological samples with therapeutic proton beams is reported. Protons with initial energies between 40 MeV and 250 MeV are degraded with polystyrene blocks of variable thickness in order to place the sample, an aqueous layer of 10 microm thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/3/304

    authors: Bashkirov V,Schulte RW

    更新日期:2002-02-07 00:00:00

  • Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility.

    abstract::Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3759

    authors: Parodi K,Mairani A,Brons S,Hasch BG,Sommerer F,Naumann J,Jäkel O,Haberer T,Debus J

    更新日期:2012-06-21 00:00:00

  • Normal levels of total body sodium and chlorine by neutron activation analysis.

    abstract::In vivo neutron activation analysis was used to measure total body sodium and chlorine in 18 male and 18 female normal adults. Corrections for body size were developed. Normalisation factors were derived which enable the prediction of the normal levels of sodium and chlorine in a subject. The coefficient of variation ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/3/002

    authors: Kennedy NS,Eastell R,Smith MA,Tothill P

    更新日期:1983-03-01 00:00:00