High-energy x-ray Talbot-Lau radiography of a human knee.

Abstract:

:We report on a radiographic measurement of an ex vivo human knee using a grating-based phase-contrast imaging setup and a medical x-ray tube at a tube voltage of 70 kV. The measurement has been carried out using a Talbot-Lau setup that is suitable to achieve a high visibility in the energy regime of medical imaging. In a medical reading by an experienced trauma surgeon signatures of chondrocalcinosis in the medial meniscus have been identified more evidently using the dark-field image in comparison to the conventional attenuation image. The analysis has been carried out at various dose levels down to 0.14 mGy measured as air kerma, which is a dose comparable to clinically used radiographic devices. The diagnosis has been confirmed by a histological analysis of the meniscus tissue. In the introduced high-frequency filtered phase-contrast image the anterior and posterior horn of the medial meniscus and the posterior cruciate ligament have also been visible. Furthermore, atherosclerotic plaque is visible in both imaging modalities, attenuation and dark-field, despite the presence of overlaying bone. This measurement, for the first time, proves the feasibility of Talbot-Lau x-ray imaging at high-energy spectra above 40 kVp and reasonable dose levels with regard to spacious and dense objects.

journal_name

Phys Med Biol

authors

Horn F,Gelse K,Jabari S,Hauke C,Kaeppler S,Ludwig V,Meyer P,Michel T,Mohr J,Pelzer G,Rieger J,Riess C,Seifert M,Anton G

doi

10.1088/1361-6560/aa7721

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

6729-6745

issue

16

eissn

0031-9155

issn

1361-6560

journal_volume

62

pub_type

杂志文章
  • Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams.

    abstract::For low-energy (up to 150 kV) x-rays, the ratio of mass-energy absorption coefficients for water to air, (mu(en)/rho)w.air, and the backscatter factor B are used in the conversion of air kerma, measured free-in-air, to water kerma on the surface of a water phantom. For clinical radiotherapy, similar conversion factors...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/1/011

    authors: Ma CM,Seuntjens JP

    更新日期:1999-01-01 00:00:00

  • Sparse-view x-ray CT reconstruction via total generalized variation regularization.

    abstract::Sparse-view CT reconstruction algorithms via total variation (TV) optimize the data iteratively on the basis of a noise- and artifact-reducing model, resulting in significant radiation dose reduction while maintaining image quality. However, the piecewise constant assumption of TV minimization often leads to the appea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/12/2997

    authors: Niu S,Gao Y,Bian Z,Huang J,Chen W,Yu G,Liang Z,Ma J

    更新日期:2014-06-21 00:00:00

  • FDTD analysis of human body-core temperature elevation due to RF far-field energy prescribed in the ICNIRP guidelines.

    abstract::This study investigated the relationship between the specific absorption rate and temperature elevation in an anatomically-based model named NORMAN for exposure to radio-frequency far fields in the ICNIRP guidelines (1998 Health Phys. 74 494-522). The finite-difference time-domain method is used for analyzing the elec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/020

    authors: Hirata A,Asano T,Fujiwara O

    更新日期:2007-08-21 00:00:00

  • The validation of tomotherapy dose calculations in low-density lung media.

    abstract::The dose-calculation accuracy of the tomotherapy Hi-Art II(R) (Tomotherapy, Inc., Madison, WI) treatment planning system (TPS) in the presence of low-density lung media was investigated. In this evaluation, a custom-designed heterogeneous phantom mimicking the mediastinum geometry was used. Gammex LN300 and balsa wood...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/004

    authors: Chaudhari SR,Pechenaya OL,Goddu SM,Mutic S,Rangaraj D,Bradley JD,Low D

    更新日期:2009-04-21 00:00:00

  • Low-frequency conductivity tensor imaging with a single current injection using DT-MREIT.

    abstract::Diffusion tensor - magnetic resonance electrical impedance tomography (DT-MREIT) is an imaging modality to obtain low-frequency anisotropic conductivity distribution employing diffusion tensor imaging (DTI) and magnetic resonance electrical impedance tomography (MREIT) techniques. DT-MREIT is based on the linear relat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abddcf

    authors: Sadighi M,Sisman M,Acikgoz BC,Eroglu HH,Eyuboglu BM

    更新日期:2021-01-20 00:00:00

  • Exploration and application of phenomenological RBE models for proton therapy.

    abstract::The relative biological effectiveness (RBE) of protons varies with multiple physical and biological factors. Phenomenological RBE models have been developed to include such factors in the estimation of a variable RBE, in contrast to the clinically applied constant RBE of 1.1. In this study, eleven published phenomenol...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9db

    authors: Rørvik E,Fjæra LF,Dahle TJ,Dale JE,Engeseth GM,Stokkevåg CH,Thörnqvist S,Ytre-Hauge KS

    更新日期:2018-09-13 00:00:00

  • A theoretical study of quantitative flow measurements with constant infusion of short-lived isotopes.

    abstract::Recent developments in the technique of constant infusion and in emission computed tomography have provided a new method for quantitative regional flow measurements. This paper re-examines critically the theoretical relationship between flow and radioactivity during constant infusion of short-lived isotopes. Sensitivi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/6/005

    authors: Huang SC,Phelps ME,Hoffman EJ,Kuhl DE

    更新日期:1979-11-01 00:00:00

  • A variable fluence step clustering and segmentation algorithm for step and shoot IMRT.

    abstract::A step and shoot sequencer was developed that can be integrated into an IMRT optimization algorithm. The method uses non-uniform fluence steps and is adopted to the constraints of an MLC. It consists of a clustering, a smoothing and a segmentation routine. The performance of the algorithm is demonstrated for eight mat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/319

    authors: Bär W,Alber M,Nüsslin F

    更新日期:2001-07-01 00:00:00

  • Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.

    abstract::While megavoltage cone-beam computed tomography (CBCT) using an electronic portal imaging device (EPID) provides many advantages over kilovoltage (kV) CBCT, clinical adoption is limited by its high doses. Multi-layer imager (MLI) EPIDs increase DQE(0) while maintaining high resolution. However, even well-designed, hig...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa160

    authors: Hu YH,Rottmann J,Fueglistaller R,Myronakis M,Wang A,Huber P,Shedlock D,Morf D,Baturin P,Star-Lack J,Berbeco R

    更新日期:2018-01-30 00:00:00

  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations.

    abstract::A photon diffusion model has been developed to calculate the steady-state spatially resolved fluorescence from pencil beam excitation in layered tissue. The model allows the calculation of both the excitation reflectance and the fluorescence escape for an arbitrary continuous depth distribution of tissue optical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/307

    authors: Hyde DE,Farrell TJ,Patterson MS,Wilson BC

    更新日期:2001-02-01 00:00:00

  • A dose calculation method including scatter for IMRT optimization.

    abstract::IMRT optimization is an iterative process in which many dose calculations may be necessary. A fast and accurate dose calculation engine is essential for the optimization program to converge to a reliable solution in a reasonable time. Previously we developed a fast dose calculation method for IMRT optimization based o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/19/011

    authors: Wu Q

    更新日期:2004-10-07 00:00:00

  • MR-based keyhole SPECT for small animal imaging.

    abstract::The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/010

    authors: Lee KS,Roeck WW,Gullberg GT,Nalcioglu O

    更新日期:2011-02-07 00:00:00

  • STIR: software for tomographic image reconstruction release 2.

    abstract::We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to var...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/867

    authors: Thielemans K,Tsoumpas C,Mustafovic S,Beisel T,Aguiar P,Dikaios N,Jacobson MW

    更新日期:2012-02-21 00:00:00

  • Monte Carlo calculation of VMAT and helical tomotherapy dose distributions for lung stereotactic treatments with intra-fraction motion.

    abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2807

    authors: Belec J,Clark BG

    更新日期:2013-05-07 00:00:00

  • Including robustness in multi-criteria optimization for intensity-modulated proton therapy.

    abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/3/591

    authors: Chen W,Unkelbach J,Trofimov A,Madden T,Kooy H,Bortfeld T,Craft D

    更新日期:2012-02-07 00:00:00

  • Feasibility of replacing patient specific cutouts with a computer-controlled electron multileaf collimator.

    abstract::A motorized electron multileaf collimator (eMLC) was developed as an add-on device to the Varian linac for delivery of advanced electron beam therapy. It has previously been shown that electron beams collimated by an eMLC have very similar penumbra to those collimated by applicators and cutouts. Thus, manufacturing pa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5653

    authors: Eldib A,Jin L,Li J,Ma CM

    更新日期:2013-08-21 00:00:00

  • Distributed three-dimensional simulation of B-mode ultrasound imaging using a first-order k-space method.

    abstract::Computational modeling is an important tool in ultrasound imaging research, but realistic three-dimensional (3D) simulations can exceed the capabilities of serial computers. This paper uses a 3D simulator based on a k-space method that incorporates relaxation absorption and nonreflecting boundary conditions. The simul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/17/007

    authors: Daoud MI,Lacefield JC

    更新日期:2009-09-07 00:00:00

  • Implementation of biologically conformal radiation therapy (BCRT) in an algorithmic segmentation-based inverse planning approach.

    abstract::The development of new biological imaging technologies offers the opportunity to further individualize radiotherapy. Biologically conformal radiation therapy (BCRT) implies the use of the spatial distribution of one or more radiobiological parameters to guide the IMRT dose prescription. Our aim was to implement BCRT i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/N02

    authors: Vanderstraeten B,De Gersem W,Duthoy W,De Neve W,Thierens H

    更新日期:2006-08-21 00:00:00

  • Transport calculations of depth-dose distributions for gadolinium neutron capture therapy.

    abstract::Depth-dose distributions were calculated for thermal and epithermal neutron fluence and capture gamma ray dose rates using a two-dimensional neutron-coupled gamma-ray transport code (DOT 3.5) for gadolinium neutron capture therapy. The results show that (i) a capture gamma-ray dose rate of 10 Gy h-1 was obtained with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/1/010

    authors: Matsumoto T

    更新日期:1992-01-01 00:00:00

  • Effects of tissue mechanical and acoustic anisotropies on the performance of a cross-correlation-based ultrasound strain imaging method.

    abstract::The anisotropic mechanical properties (mechanical anisotropy) and view-dependent ultrasonic backscattering (acoustic anisotropy) of striated muscle due to the underlying myofiber arrangement have been well documented, but whether they impact on ultrasound strain imaging (USI) techniques remains unclear. The aim of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa530b

    authors: Li H,Lee WN

    更新日期:2017-02-21 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Computational fluid dynamics modelling of perfusion measurements in dynamic contrast-enhanced computed tomography: development, validation and clinical applications.

    abstract::Dynamic contrast-enhanced computed tomography (DCE-CT) is an imaging tool that aids in evaluating functional characteristics of tissue at different stages of disease management: diagnostic, radiation treatment planning, treatment effectiveness, and monitoring. Clinical validation of DCE-derived perfusion parameters re...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/6111

    authors: Peladeau-Pigeon M,Coolens C

    更新日期:2013-09-07 00:00:00

  • Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

    abstract::A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/12/006

    authors: Meissner P,Jacob M,Rassow J

    更新日期:1988-12-01 00:00:00

  • A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode.

    abstract::Respiratory gating based on external surrogates is performed in many clinics. We have developed a new technique for treatment verification using an electronic portal imaging device (EPID) in cine mode for gated 3D conformal therapy. Implanted radiopaque fiducial markers inside or near the target are required for this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/16/002

    authors: Berbeco RI,Neicu T,Rietzel E,Chen GT,Jiang SB

    更新日期:2005-08-21 00:00:00

  • Investigation of the refractive index decrement of 3D printing materials for manufacturing breast phantoms for phase contrast imaging.

    abstract::3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that sof...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0670

    authors: Esposito G,Mettivier G,Bliznakova K,Bliznakov Z,Bosmans H,Bravin A,Buliev I,Di Lillo F,Ivanov D,Minutillo M,Sarno A,Vignero J,Russo P

    更新日期:2019-03-27 00:00:00

  • A fast inverse consistent deformable image registration method based on symmetric optical flow computation.

    abstract::Deformable image registration is widely used in various radiation therapy applications including daily treatment planning adaptation to map planned tissue or dose to changing anatomy. In this work, a simple and efficient inverse consistency deformable registration method is proposed with aims of higher registration ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/21/017

    authors: Yang D,Li H,Low DA,Deasy JO,El Naqa I

    更新日期:2008-11-07 00:00:00

  • Precision estimation and imaging of normal and shear components of the 3D strain tensor in elastography.

    abstract::In elastography we have previously developed a tracking and correction method that estimates the axial and lateral strain components along and perpendicular to the compressor/scanning axis following an externally applied compression. However, the resulting motion is a three-dimensional problem. Therefore, in order to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/6/311

    authors: Konofagou EE,Ophir J

    更新日期:2000-06-01 00:00:00

  • Radioluminescence in biomedicine: physics, applications, and models.

    abstract::The electromagnetic spectrum contains different frequency bands useful for medical imaging and therapy. Short wavelengths (ionizing radiation) are commonly used for radiological and radionuclide imaging and for cancer radiation therapy. Intermediate wavelengths (optical radiation) are useful for more localized imaging...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6560/aaf4de

    authors: Klein JS,Sun C,Pratx G

    更新日期:2019-02-06 00:00:00

  • Exact analytic reconstruction in x-ray fluorescence CT and approximated versions.

    abstract::X-ray fluorescence computed tomography (XFCT) is a relatively new synchrotron-based imaging modality aiming at reconstructing the distribution of nonradiative elements within a sample irradiated with high-intensity monochromatic x-rays. In a recent paper La Rivière (2004 Phys. Med. Biol. 49 2391-405) presented an appr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/4/007

    authors: Miqueles EX,De Pierro AR

    更新日期:2010-02-21 00:00:00