4D digital tomosynthesis image reconstruction using brute force-based adaptive total variation (BF-ATV) in a prototype LINAC system.

Abstract:

:Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster technique that delivers a much lower radiation dose by reducing the number of projections in a limited angular range. Unfortunately, 4D-DTS introduces strong aliasing artifacts in the reconstructed images due to the sparsely sampled projections in each respiratory phase bin. The authors hereby suggest a novel low-dose 4D-DTS image reconstruction method that achieves a compromise between the occurrence of aliasing artifacts and image smoothing using a brute force-based adaptive weighting parameter searching technique. We used a prototype LINAC system mounted with a flat-panel detector to acquire tomosynthesis projections of respiratory motion in a phantom in the anterior-posterior (AP) and lateral views. Three different 4D-DTS image reconstruction schemes that included conventional filtered back-projection (FBP), adaptive steepest descent projection onto convex sets (ASD-POCS), and the proposed brute force-based adaptive total variation (BF-ATV) were implemented in four different respiratory phase bins for both AP and lateral views. All reconstructions were accelerated using a single GPU card to reduce the computation time. To study the performance of the algorithm under various sparse conditions, we operated the prototype system in three different gantry sweep modes. The results indicate that the proposed BF-ATV method yields the largest structural similarities in the differenced image between the ground-truth dataset acquired using the slow gantry sweep mode and the sparse dataset from both moderate and fast sweep modes. In addition, the proposed method maintained the object sharpness with less streaking lines and small loss of sharpness compared to the conventional FBP and ASD-POCS methods. In conclusion, the proposed low-dose 4D-DTS reconstruction scheme may provide better performance due in part to its rapid scanning. Therefore, it is potentially applicable to practical 4D imaging for radiotherapy.

journal_name

Phys Med Biol

authors

Choi S,Lee S,Kang YN,Hsieh SS,Kim HJ

doi

10.1088/1361-6560/ab0d50

subject

Has Abstract

pub_date

2019-05-02 00:00:00

pages

095029

issue

9

eissn

0031-9155

issn

1361-6560

journal_volume

64

pub_type

杂志文章
  • Theoretical modeling of yields for proton-induced reactions on natural and enriched molybdenum targets.

    abstract::Recent acute shortage of medical radioisotopes prompted investigations into alternative methods of production and the use of a cyclotron and ¹⁰⁰Mo(p,2n)(99m)Tc reaction has been considered. In this context, the production yields of (99m)Tc and various other radioactive and stable isotopes which will be created in the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/002

    authors: Celler A,Hou X,Bénard F,Ruth T

    更新日期:2011-09-07 00:00:00

  • Simulational validation of color magnetic particle imaging (cMPI).

    abstract::Exploiting the field response of magnetic tracers, magnetic particle imaging (MPI) allows direct, local quantification of the tracer concentration in bulk structures. Here, we investigated the use of characteristic field response functions to spatially resolve the absolute concentration of multiple nanoparticle specie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6521

    authors: Han SH,Cho E,Lee DK,Cho G,Kim YR,Cho H

    更新日期:2014-11-07 00:00:00

  • Monte Carlo correction factors for a Farmer 0.6 cm3 ion chamber dose measurement in the build-up region of the 6 MV clinical beam.

    abstract::Reference dosimetry of photon fields is a well-established subject and currently available protocols (such as the IAEA TRS-398 and AAPM TG-51) provide methods for converting the ionization chamber (IC) reading into dose to water, provided reference conditions of charged particle equilibrium (CPE) are fulfilled. But th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/011

    authors: Pena J,Sánchez-Doblado F,Capote R,Terrón JA,Gómez F

    更新日期:2006-03-21 00:00:00

  • A robust state-space kinetics-guided framework for dynamic PET image reconstruction.

    abstract::Dynamic PET image reconstruction is a challenging issue due to the low SNR and the large quantity of spatio-temporal data. We propose a robust state-space image reconstruction (SSIR) framework for activity reconstruction in dynamic PET. Unlike statistically-based frame-by-frame methods, tracer kinetic modeling is inco...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/8/010

    authors: Tong S,Alessio AM,Kinahan PE,Liu H,Shi P

    更新日期:2011-04-21 00:00:00

  • The experimental dose ranges influence the LETd dependency of the proton minimum RBE (RBEmin).

    abstract::Cell experiments have shown the proton relative biological effectiveness (RBE) to vary with dose and linear energy transfer (LET), which has led to development of variable RBE models. The RBE is normally estimated from two independent functions, the RBEmax and RBEmin, describing the extreme RBE at low and high doses. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab369a

    authors: Rørvik E,Thörnqvist S,Ytre-Hauge KS

    更新日期:2019-09-23 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

    abstract::To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novik...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/018

    authors: Tang Q,Zeng GL,Huang Q

    更新日期:2006-12-07 00:00:00

  • Isotope computed tomography using cone-beam geometry: a comparison of two reconstruction algorithms.

    abstract::A CT scanner has been constructed specifically to determine the three-dimensional distribution of bone mineral in the medullary cavities of the radius, ulna and femur. A source of x-rays (153Gd) and a multiwire proportional counter (MWPC) are mounted at opposite ends of a diameter of an annular mounting. The limb is p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/002

    authors: Horsman A,Sutcliffe J,Burkinshaw L,Wild P,Skilling J,Webb S

    更新日期:1987-10-01 00:00:00

  • A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model.

    abstract::Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm2) was developed in terms of TERMA and a total energy depo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/001

    authors: Aspradakis MM,Redpath AT

    更新日期:1997-08-01 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

    abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5929

    authors: Li Q,Olafsson R,Ingram P,Wang Z,Witte R

    更新日期:2012-10-07 00:00:00

  • Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.

    abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7905

    authors: Bernatowicz K,Lomax AJ,Knopf A

    更新日期:2013-11-21 00:00:00

  • Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries.

    abstract::This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/9/N49

    authors: Agnew A,Agnew CE,Grattan MW,Hounsell AR,McGarry CK

    更新日期:2014-05-07 00:00:00

  • Methodologies in the modeling of combined chemo-radiation treatments.

    abstract::The variety of treatment options for cancer patients has increased significantly in recent years. Not only do we combine radiation with surgery and chemotherapy, new therapeutic approaches such as immunotherapy and targeted therapies are starting to play a bigger role. Physics has made significant contributions to rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/R344

    authors: Grassberger C,Paganetti H

    更新日期:2016-11-07 00:00:00

  • Calculation of van't Hoff enthalpy associated with aspirin-induced change in liposomal membrane anisotropy.

    abstract::The lipid disordering effect of aspirin on the liposomal membrane of dipalmitoyl phosphatidyl choline has recently been studied using the fluorescence polarization method. From the anisotropy-temperature curve, we have calculated here the associated change in van't Hoff enthalpy. Since the fluorescence technique requi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/3/003

    authors: De S,Ghosh AK,Basu R,Nandy P

    更新日期:1996-03-01 00:00:00

  • STIR: software for tomographic image reconstruction release 2.

    abstract::We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to var...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/867

    authors: Thielemans K,Tsoumpas C,Mustafovic S,Beisel T,Aguiar P,Dikaios N,Jacobson MW

    更新日期:2012-02-21 00:00:00

  • A facility for biomedical experiments with thermal neutrons.

    abstract::The Studsvik thermal-neutron facility was originally designed for neutron capture radiography (NCR) at high thermal-neutron fluence and low fast-neutron contamination. It has now been modified to permit irradiation of living cells and animals without the need for stopping and restarting the R2-0 reactor. Previous calc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/8/006

    authors: Pettersson OA,Chiangmai SN,Grusell E,Larsson B

    更新日期:1993-08-01 00:00:00

  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00

  • An absorptiometry method for the determination of arterial blood concentration of injected iodinated contrast agent.

    abstract::A single photon absorptiometry method to measure the arterial concentration of injected iodinated contrast agent was developed. A prototype absorptiometry unit was built which consists of either a square or circular cross section acrylic (polymethylmethacrylate) cuvette connected to an arterial catheter at one end and...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/9/002

    authors: Yeung WT,Lee TY,Del Maestro RF,Kozak R,Bennett JD,Brown T

    更新日期:1992-09-01 00:00:00

  • Radiance and particle fluence.

    abstract::The concepts of radiance and fluence are fundamental to the description of a radiation field. The International Commission on Radiological Units and Measurements (ICRU) has defined fluence in terms of the number of the radiation particles crossing a small sampling sphere. A second definition has been proposed in which...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/6/011

    authors: Papiez L,Battista JJ

    更新日期:1994-06-01 00:00:00

  • A comprehensive study of the use of temporal moments in time-resolved diffuse optical tomography: part I. Theoretical material.

    abstract::The problem of fluorescence diffuse optical tomography consists in localizing fluorescent markers from near-infrared light measurements. Among the different available acquisition modalities, the time-resolved modality is expected to provide measurements of richer information content. To extract this information, the m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/23/004

    authors: Ducros N,Hervé L,Da Silva A,Dinten JM,Peyrin F

    更新日期:2009-12-07 00:00:00

  • Arc-modulated radiation therapy based on linear models.

    abstract::This paper reports an inverse arc-modulated radiation therapy planning technique based on linear models. It is implemented with a two-step procedure. First, fluence maps for 36 fixed-gantry beams are generated using a linear model-based intensity-modulated radiation therapy (IMRT) optimization algorithm. The 2D fluenc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/020

    authors: Zhu X,Thongphiew D,McMahon R,Li T,Chankong V,Yin FF,Wu QJ

    更新日期:2010-07-07 00:00:00

  • Beam configurations for 3D tomographic intensity modulated radiation therapy.

    abstract::We extend the theory of three-dimensional (3D) tomographic intensity modulated radiation therapy (IMRT). The geometry consists of two-dimensional modulated beams on a sphere centred in the tumour. The theory provides an efficient algorithm for computing beam modulation patterns that approximately 'reconstruct' the pre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/5/306

    authors: Levine RY,Braunstein M

    更新日期:2002-03-07 00:00:00

  • Improved iterative tomographic reconstruction for x-ray imaging with edge-illumination.

    abstract::Iterative tomographic reconstruction has been established as a viable alternative for data analysis in phase-sensitive x-ray imaging based on the edge-illumination principle. However, previously published approaches did not account for drifts of optical elements during a scan, which can lead to artefacts. Up to now, t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab439d

    authors: Modregger P,Meganck J,Hagen CK,Massimi L,Olivo A,Endrizzi M

    更新日期:2019-10-10 00:00:00

  • Implementation of biologically conformal radiation therapy (BCRT) in an algorithmic segmentation-based inverse planning approach.

    abstract::The development of new biological imaging technologies offers the opportunity to further individualize radiotherapy. Biologically conformal radiation therapy (BCRT) implies the use of the spatial distribution of one or more radiobiological parameters to guide the IMRT dose prescription. Our aim was to implement BCRT i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/16/N02

    authors: Vanderstraeten B,De Gersem W,Duthoy W,De Neve W,Thierens H

    更新日期:2006-08-21 00:00:00

  • Radiation binary targeted therapy for HER-2 positive breast cancers: assumptions, theoretical assessment and future directions.

    abstract::A novel radiation targeted therapy is investigated for HER-2 positive breast cancers. The proposed concept combines two known approaches, but never used together for the treatment of advanced, relapsed or metastasized HER-2 positive breast cancers. The proposed radiation binary targeted concept is based on the anti HE...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/001

    authors: Mundy DW,Harb W,Jevremovic T

    更新日期:2006-03-21 00:00:00

  • New materials for dielectric simulation of tissues.

    abstract::Two novel materials have been developed to simulate the dielectric properties of human muscle and fat at 1000 MHz. These materials, which are based on ethanediol set with gelatine, are easily made and have good mechanical properties. The complex permittivity, epsilon *, of each material was measured with an open-ended...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/12/002

    authors: Robinson MP,Richardson MJ,Green JL,Preece AW

    更新日期:1991-12-01 00:00:00

  • Error propagation in quantitative biplane cineroentgenography.

    abstract::The propagation of errors in quantitative biplane cineroentgenography was investigated to see which variables were the most critical. The analysis was carried out both for the propagation of root-mean-square errors and for errors as derived by a Taylor expansion of the reconstruction equations. The reconstruction is m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/4/009

    authors: Smith WM,Starmer CF

    更新日期:1978-07-01 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • Modelling simple helically delivered dose distributions.

    abstract::In a previous paper, we described quality assurance procedures for Hi-Art helical tomotherapy machines. Here, we develop further some ideas discussed briefly in that paper. Simple helically generated dose distributions are modelled, and relationships between these dose distributions and underlying characteristics of H...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/7/013

    authors: Fenwick JD,Tomé WA,Kissick MW,Mackie TR

    更新日期:2005-04-07 00:00:00