Analysis of a large number of clinical studies for breast cancer radiotherapy: estimation of radiobiological parameters for treatment planning.

Abstract:

:Numerous studies of early-stage breast cancer treated with breast conserving surgery (BCS) and radiotherapy (RT) have been published in recent years. Both external beam radiotherapy (EBRT) and/or brachytherapy (BT) with different fractionation schemes are currently used. The present RT practice is largely based on empirical experience and it lacks a reliable modelling tool to compare different RT modalities or to design new treatment strategies. The purpose of this work is to derive a plausible set of radiobiological parameters that can be used for RT treatment planning. The derivation is based on existing clinical data and is consistent with the analysis of a large number of published clinical studies on early-stage breast cancer. A large number of published clinical studies on the treatment of early breast cancer with BCS plus RT (including whole breast EBRT with or without a boost to the tumour bed, whole breast EBRT alone, brachytherapy alone) and RT alone are compiled and analysed. The linear quadratic (LQ) model is used in the analysis. Three of these clinical studies are selected to derive a plausible set of LQ parameters. The potential doubling time is set a priori in the derivation according to in vitro measurements from the literature. The impact of considering lower or higher T(pot) is investigated. The effects of inhomogeneous dose distributions are considered using clinically representative dose volume histograms. The derived LQ parameters are used to compare a large number of clinical studies using different regimes (e.g., RT modality and/or different fractionation schemes with different prescribed dose) in order to validate their applicability. The values of the equivalent uniform dose (EUD) and biologically effective dose (BED) are used as a common metric to compare the biological effectiveness of each treatment regime. We have obtained a plausible set of radiobiological parameters for breast cancer: alpha = 0.3 Gy(-1), alpha/beta = 10 Gy and sub-lethal damage repair time T(rep) = 1 h (mono-exponential behaviour is assumed). This set of parameters is consistent with in vitro experiments and with previously reported analyses. Using this set of parameters, we have found that most of the studies, using BCS plus whole breast RT and a boost to the tumour bed, have EUDs ranging from 60-70 Gy. No correlation is found between BED and the local recurrence rate. The treatments of BCS plus brachytherapy alone have a wide range of EUD (30-50 Gy), which is significantly lower than the treatments with whole breast EBRT plus a boost of the tumour bed. The studies with different fractionation schemes for whole breast EBRT also show a significant variation of EUD. Carefully designed clinical studies with large numbers of patients are required to determine clinically the relative effectiveness of these treatment variations. The derived LQ parameter set based on clinical data is consistent with in vitro experiments and previous studies. As demonstrated in the present work, these radiobiological parameters can be potentially useful in radiotherapy treatment planning for early breast cancer, e.g., in comparing biological effectiveness of different radiotherapy modalities, different fractionation schemes and in designing new treatment strategies.

journal_name

Phys Med Biol

authors

Guerrero M,Li XA

doi

10.1088/0031-9155/48/20/004

subject

Has Abstract

pub_date

2003-10-21 00:00:00

pages

3307-26

issue

20

eissn

0031-9155

issn

1361-6560

journal_volume

48

pub_type

杂志文章,meta分析
  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol.

    abstract::The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast. The conversion factors currently used were obtained by computer simulation of a model breast with a composition of 50% adipose and 50% glandular tissues by ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/11/308

    authors: Dance DR,Skinner CL,Young KC,Beckett JR,Kotre CJ

    更新日期:2000-11-01 00:00:00

  • Influence of beam characteristics and detector size in negative-pion dose studies.

    abstract::Dose calculations were performed for a tissue phantom irradiated by uniform circular beams of negative pions with an assumed gaussian momentum distribution. The mean momentum of the pions was varied from 104.4 to 171.5 MeV/c (mean range 5-20 cm in unit-density tissue) and the momentum spread from 0 to 5% of the mean. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/3/012

    authors: Hamm RN,Wright HA,Turner JE

    更新日期:1979-05-01 00:00:00

  • Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems.

    abstract::Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa307

    authors: Wood TJ,Moore CS,Saunderson JR,Beavis AW

    更新日期:2018-01-16 00:00:00

  • Quantification and normalization of x-ray mammograms.

    abstract::The analysis of (x-ray) mammograms remains qualitative, relying on the judgement of clinicians. We present a novel method to compute a quantitative, normalized measure of tissue radiodensity traversed by the primary beam incident on each pixel of a mammogram, a measure we term the standard attenuation rate (SAR). SAR ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6519

    authors: Tromans CE,Cocker MR,Brady SM

    更新日期:2012-10-21 00:00:00

  • Effects of bone- and air-tissue inhomogeneities on the dose distributions of the Leksell Gamma Knife calculated with PENELOPE.

    abstract::Monte Carlo simulation with PENELOPE (version 2003) is applied to calculate Leksell Gamma Knife dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/018

    authors: Al-Dweri FM,Rojas EL,Lallena AM

    更新日期:2005-12-07 00:00:00

  • Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications.

    abstract::The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/5/005

    authors: Zoetelief J,Broerse JJ

    更新日期:1983-05-01 00:00:00

  • Ion concentration and haematocrit as determinants of impedance in an erythrocyte suspension model of renal medullary tissue.

    abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/11/011

    authors: Niewiadomski W,Sadowski J,Badzyńska B,Rasmussen SN

    更新日期:1990-11-01 00:00:00

  • Ionization chamber correction factors for MR-linacs.

    abstract::Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to system...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac4f2

    authors: Pojtinger S,Dohm OS,Kapsch RP,Thorwarth D

    更新日期:2018-06-07 00:00:00

  • A water calorimeter for neutron dosimetry.

    abstract::A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/005

    authors: Galloway G,Greening JR,Williams JR

    更新日期:1986-04-01 00:00:00

  • Characterization of female breast lesions from multi-wavelength time-resolved optical mammography.

    abstract::Characterization of both malignant and benign lesions in the female breast is presented as the result of a clinical study that involved more than 190 subjects in the framework of the OPTIMAMM European project. All the subjects underwent optical mammography, by means of a multi-wavelength time-resolved mammograph, in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/11/004

    authors: Spinelli L,Torricelli A,Pifferi A,Taroni P,Danesini G,Cubeddu R

    更新日期:2005-06-07 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images.

    abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1cdd

    authors: Meier JG,Einstein SA,Diab RH,Erasmus LJ,Xu G,Mawlawi OR

    更新日期:2019-05-16 00:00:00

  • Arc-modulated radiation therapy based on linear models.

    abstract::This paper reports an inverse arc-modulated radiation therapy planning technique based on linear models. It is implemented with a two-step procedure. First, fluence maps for 36 fixed-gantry beams are generated using a linear model-based intensity-modulated radiation therapy (IMRT) optimization algorithm. The 2D fluenc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/020

    authors: Zhu X,Thongphiew D,McMahon R,Li T,Chankong V,Yin FF,Wu QJ

    更新日期:2010-07-07 00:00:00

  • Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media.

    abstract::A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/11/301

    authors: Chetty IJ,Moran JM,Nurushev TS,McShan DL,Fraass BA,Wilderman SJ,Bielajew AF

    更新日期:2002-06-07 00:00:00

  • Comments on 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy'.

    abstract::By analyzing the radiobiological model, and the equations derived from the model, it is shown that the main results of the article 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy' by Wiklund et al (2011 Phys. Med. Biol. 56 7585-600) are valid only under the condition...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/58/18/6585

    authors: Grusell E

    更新日期:2013-09-21 00:00:00

  • Relating two techniques for handling uncertainties in IMRT optimization.

    abstract::Radiotherapy treatment planning is associated with uncertainties. Examples are uncertainties in the tumour location due to organ movement or the inter/intra observer variability in target definition. Different approaches to incorporate uncertainties into IMRT optimization have been proposed. In this note, we point out...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/N04

    authors: Unkelbach J,Oelfke U

    更新日期:2006-12-07 00:00:00

  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00

  • Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy.

    abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/007

    authors: Schreibmann E,Lahanas M,Xing L,Baltas D

    更新日期:2004-03-07 00:00:00

  • Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment.

    abstract::Fast heat extraction is critically important to obtain the maximal benefit of cryogen spray cooling (CSC) during laser therapy of shallow skin lesions, such as port wine stain birthmarks. However, a film of liquid cryogen can build up on the skin surface, impairing heat transfer due to the relatively low thermal condu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/301

    authors: Majaron B,Svaasand LO,Aguilar G,Nelson JS

    更新日期:2002-09-21 00:00:00

  • Review on the characteristics of radiation detectors for dosimetry and imaging.

    abstract::The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been tran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/20/R303

    authors: Seco J,Clasie B,Partridge M

    更新日期:2014-10-21 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Infrasonic analysis of carotid vibration as a diagnostic method in carotid insufficiency syndrome.

    abstract::The infrasonic part of the spectrum of the carotid artery wall vibration in the neck was obtained. Differences between the spectral content and vibrational amplitude in normal and occluded carotids were found. The application of this technique in clinical practice could be useful in the detection of the carotid insuff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/011

    authors: Anastassiades AJ,Petounis AD

    更新日期:1976-01-01 00:00:00

  • Synchrotron microangiography with no contrast agent.

    abstract::Coherent x-rays from synchrotron sources are increasingly used in non-conventional radiological techniques ('phase-contrast' radiology). Our experiments demonstrate that by using white (unmonochromatic) radiation and a time-resolving system, it is possible to image microscopic details of moving blood vessels in differ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/4/002

    authors: Hwu Y,Tsai WL,Je JH,Seol SK,Kim B,Groso A,Margaritondo G,Lee KH,Seong JK

    更新日期:2004-02-21 00:00:00

  • The use of customized spreadsheets in radiation therapy.

    abstract::A number of radiation-therapy-related uses based on a commercially available spreadsheet program have been developed at our facility. The graphics and display capabilities inherent in these spreadsheet programs allow for concise visual results. The spreadsheets are used as an independent check for several types of rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/6/007

    authors: Balog JP,Sibata CH,Podgorsak MB,Shin KH

    更新日期:1995-06-01 00:00:00

  • Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation.

    abstract::The purpose of this work is to model electron contamination in clinical photon beams and to commission the source model using measured data for Monte Carlo treatment planning. In this work, a planar source is used to represent the contaminant electrons at a plane above the upper jaws. The source size depends on the di...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/12/013

    authors: Yang J,Li JS,Qin L,Xiong W,Ma CM

    更新日期:2004-06-21 00:00:00

  • High resolution propagation-based imaging system for in vivo dynamic computed tomography of lungs in small animals.

    abstract::We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab8d2

    authors: Preissner M,Murrie RP,Pinar I,Werdiger F,Carnibella RP,Zosky GR,Fouras A,Dubsky S

    更新日期:2018-04-20 00:00:00

  • Reduced-order constrained optimization in IMRT planning.

    abstract::This paper presents a new algorithm for constrained intensity-modulated radiotherapy (IMRT) planning, made tractable by a dimensionality reduction using a set of plans obtained by fast, unconstrained optimizations. The main result is to reduce planning time by an order of magnitude, producing viable five field prostat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/23/007

    authors: Lu R,Radke RJ,Yang J,Happersett L,Yorke E,Jackson A

    更新日期:2008-12-07 00:00:00

  • Medical applications of synchrotron radiation.

    abstract::The medical imaging and therapeutic technologies that are based on the use of radiation are reviewed briefly, with special emphasis on the recent developments of synchrotron radiation (SR) methods. New results have been achieved in all of these areas since the last comprehensive reviews were written in this field. Thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/48/13/201

    authors: Suortti P,Thomlinson W

    更新日期:2003-07-07 00:00:00

  • Fibre-optic sensors in health care.

    abstract::Biomedical fibre-optic sensors are attractive for the measurement of physical, chemical and biochemical parameters and for spectral measurements directly performed on the patient. An overview of fibre-optic sensors for in vivo monitoring is given, with particular attention paid to the advantages that these sensors are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/42/5/015

    authors: Mignani AG,Baldini F

    更新日期:1997-05-01 00:00:00