Quantification and normalization of x-ray mammograms.

Abstract:

:The analysis of (x-ray) mammograms remains qualitative, relying on the judgement of clinicians. We present a novel method to compute a quantitative, normalized measure of tissue radiodensity traversed by the primary beam incident on each pixel of a mammogram, a measure we term the standard attenuation rate (SAR). SAR enables: the estimation of breast density which is linked to cancer risk; direct comparison between images; the full potential of computer aided diagnosis to be utilized; and a basis for digital breast tomosynthesis reconstruction. It does this by removing the effects of the imaging conditions under which the mammogram is acquired. First, the x-ray spectrum incident upon the breast is calculated, and from this, the energy exiting the breast is calculated. The contribution of scattered radiation is calculated and subtracted. The SAR measure is the scaling factor that must be applied to the reference material in order to match the primary attenuation of the breast. Specifically, this is the scaled reference material attenuation which when traversed by an identical beam to that traversing the breast, and when subsequently detected, results in the primary component of the pixel intensity observed in the breast image. We present results using two tissue equivalent phantoms, as well as a sensitivity analysis to detector response changes over time and possible errors in compressed thickness measurement.

journal_name

Phys Med Biol

authors

Tromans CE,Cocker MR,Brady SM

doi

10.1088/0031-9155/57/20/6519

subject

Has Abstract

pub_date

2012-10-21 00:00:00

pages

6519-40

issue

20

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • In vivo evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis.

    abstract::Non-invasive evaluation of the Achilles tendon elastic properties may enhance diagnosis of tendon injury and the assessment of recovery treatments. Shear wave elastography has shown to be a powerful tool to estimate tissue mechanical properties. However, its applicability to quantitatively evaluate tendon stiffness is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/3/505

    authors: Brum J,Bernal M,Gennisson JL,Tanter M

    更新日期:2014-02-07 00:00:00

  • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT).

    abstract::In this work, we investigate longitudinal sampling and aliasing effects in multi-slice helical CT. We demonstrate that longitudinal aliasing can be a significant, complicated, and potentially detrimental effect in multi-slice helical CT reconstructions. Multi-slice helical CT scans are generally undersampled longitudi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/15/318

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-07 00:00:00

  • Calculation of radiation exposures from patients to whom radioactive materials have been administered.

    abstract::Spreadsheet templates which calculate cumulative exposures to other persons from patients to whom radioactive materials have been administered have been developed by the authors. Calculations can be based on any specified single-, bi- or tri-exponential whole-body clearance rate and a diurnal (or any other periodic) c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/3/003

    authors: Cormack J,Shearer J

    更新日期:1998-03-01 00:00:00

  • Experimental determination of pCo perturbation factors for plane-parallel chambers.

    abstract::For plane-parallel chambers used in electron dosimetry, modern dosimetry protocols recommend a cross-calibration against a calibrated cylindrical chamber. The rationale for this is the unacceptably large (up to 3-4%) chamber-to-chamber variations of the perturbation factors (pwall)Co, which have been reported for plan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/52/23/026

    authors: Kapsch RP,Bruggmoser G,Christ G,Dohm OS,Hartmann GH,Schüle E

    更新日期:2007-12-07 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • Dark-field signal extraction in propagation-based phase-contrast imaging.

    abstract::A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed metho...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abac9d

    authors: Gureyev TE,Paganin DM,Arhatari B,Taba ST,Lewis S,Brennan PC,Quiney HM

    更新日期:2020-11-17 00:00:00

  • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.

    abstract::Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/7/003

    authors: Baker SJ,Budgell GJ,MacKay RI

    更新日期:2005-04-07 00:00:00

  • An experimental and Monte Carlo investigation of the energy dependence of alanine/EPR dosimetry: I. Clinical x-ray beams.

    abstract::The energy dependence of alanine/EPR dosimetry, in terms of absorbed dose-to-water for clinical 6, 10, 25 MV x-rays and 60Co gamma-rays was investigated by measurements and Monte Carlo (MC) calculations. The dose rates were traceable to the NRC primary standard for absorbed dose, a sealed water calorimetry. The electr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/2/006

    authors: Zeng GG,McEwen MR,Rogers DW,Klassen NV

    更新日期:2004-01-21 00:00:00

  • An automatic algorithm to exploit the symmetries of the system response matrix in positron emission tomography iterative reconstruction.

    abstract::Positron emission tomography (PET) iterative 3D reconstruction is a very computational demanding task. One of the main issues of the iterative reconstruction concerns the management of the system response matrix (SRM). The SRM models the relationship between the projection and the voxel space and its memory footprint ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae12b

    authors: Camarlinghi N,Sportelli G,Guerra AD,Belcari N

    更新日期:2018-09-28 00:00:00

  • Detector arrangement and sampling characteristics in rotary positron-emission computed tomography.

    abstract::A rotary positron-emission computed tomography system has been proposed in which detectors are mounted unequally spaced on a ring, so as to provide fine and uniform linear sampling during a 360 degree rotation of the ring around its centre. The usefulness of a simple iterative method for searching for a suitable arran...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/011

    authors: Yamamoto M

    更新日期:1981-05-01 00:00:00

  • A biological approach to the platelet survival curve with criticism of previous interpretations.

    abstract::The biological mechanisms of platelet destruction must be correctly identified before platelet survival curves can be interpreted. This report develops a theory of platelet destruction which is compared with experiments performed on platelets labelled with the radioactive isotope 51Cr. Platelet destruction rate is a c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/12/001

    authors: Trowbridge EA,Martin JF

    更新日期:1983-12-01 00:00:00

  • A neural network regression model for relative dose computation.

    abstract::This paper describes a neural network (NN) regression model for relative dose computation. The input signal of the NN model includes depths and field sizes and the output is the relative dose, for example, percentage depth dose (%DD) or tissue-air ratio (TAR) in this paper. After a functional link has been created, th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/4/307

    authors: Wu X,Zhu Y

    更新日期:2000-04-01 00:00:00

  • Monte Carlo correction factors for a Farmer 0.6 cm3 ion chamber dose measurement in the build-up region of the 6 MV clinical beam.

    abstract::Reference dosimetry of photon fields is a well-established subject and currently available protocols (such as the IAEA TRS-398 and AAPM TG-51) provide methods for converting the ionization chamber (IC) reading into dose to water, provided reference conditions of charged particle equilibrium (CPE) are fulfilled. But th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/6/011

    authors: Pena J,Sánchez-Doblado F,Capote R,Terrón JA,Gómez F

    更新日期:2006-03-21 00:00:00

  • The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450 MHz dipole near field.

    abstract::As the use of radiofrequency (RF) electromagnetic (EM) fields has increased along with increased use of wireless communication, the possible related health risks have also been widely discussed. One safety aspect is the interaction of medical implants and RF devices like mobile phones. In the literature, effects on ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/5/001

    authors: Virtanen H,Keshvari J,Lappalainen R

    更新日期:2007-03-07 00:00:00

  • Modelling pencil-beam divergence with the electron pencil-beam redefinition algorithm.

    abstract::The electron pencil-beam redefinition algorithm (PBRA), which is used to calculate electron beam dose distributions, assumes that the virtual source of each pencil beam is identical to that of the broad beam incident on the patient. In the present work, a virtual source specific for each pencil beam is modelled by inc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/306

    authors: Boyd RA,Hogstrom KR,White RA,Starkschall G

    更新日期:2001-11-01 00:00:00

  • Posture-specific phantoms representing female and male adults in Monte Carlo-based simulations for radiological protection.

    abstract::Does the posture of a patient have an effect on the organ and tissue absorbed doses caused by x-ray examinations? This study aims to find the answer to this question, based on Monte Carlo (MC) simulations of commonly performed x-ray examinations using adult phantoms modelled to represent humans in standing as well as ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/15/014

    authors: Cassola VF,Kramer R,Brayner C,Khoury HJ

    更新日期:2010-08-07 00:00:00

  • Segmentation and classification of thyroid follicular neoplasm using cascaded convolutional neural network.

    abstract::In this paper, we present a segmentation and classification method for thyroid follicular neoplasms based on a combination of the prior-based level set method and deep convolutional neural network. The proposed method aims to discriminate thyroid follicular adenoma (TFA) and follicular thyroid carcinoma (FTC) in ultra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc6f2

    authors: Yang B,Yan M,Yan Z,Zhu C,Xu D,Dong F

    更新日期:2020-11-02 00:00:00

  • An integrated platform for image-guided cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an effective procedure for patients with heart failure but 30% of patients do not respond. This may be due to sub-optimal placement of the left ventricular (LV) lead. It is hypothesized that the use of cardiac anatomy, myocardial scar distribution and dyssynchrony information...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/10/2953

    authors: Ma YL,Shetty AK,Duckett S,Etyngier P,Gijsbers G,Bullens R,Schaeffter T,Razavi R,Rinaldi CA,Rhode KS

    更新日期:2012-05-21 00:00:00

  • Volumetric CT with sparse detector arrays (and application to Si-strip photon counters).

    abstract::Novel x-ray medical imaging sensors, such as photon counting detectors (PCDs) and large area CCD and CMOS cameras can involve irregular and/or sparse sampling of the detector plane. Application of such detectors to CT involves undersampling that is markedly different from the commonly considered case of sparse angular...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/90

    authors: Sisniega A,Zbijewski W,Stayman JW,Xu J,Taguchi K,Fredenberg E,Lundqvist M,Siewerdsen JH

    更新日期:2016-01-07 00:00:00

  • Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

    abstract::Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/7/310

    authors: Zaidi H,Diaz-Gomez M,Boudraa A,Slosman DO

    更新日期:2002-04-07 00:00:00

  • Comparing the effectiveness and efficiency of various gating approaches for PBS proton therapy of pancreatic cancer using 4D-MRI datasets.

    abstract::Abdominal organ motion may lead to considerable uncertainties in pencil-beam scanning (PBS) proton therapy of pancreatic cancer. Beam gating, where irradiation only occurs in certain breathing phases in which the gating conditions are fulfilled, may be an option to reduce the interplay effect between tumor motion and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1175

    authors: Dolde K,Naumann P,Dávid C,Kachelriess M,Lomax AJ,Weber DC,Saito N,Burigo LN,Pfaffenberger A,Zhang Y

    更新日期:2019-04-10 00:00:00

  • Algorithm and performance of a clinical IMRT beam-angle optimization system.

    abstract::This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/19/007

    authors: Djajaputra D,Wu Q,Wu Y,Mohan R

    更新日期:2003-10-07 00:00:00

  • Transport-based quantitative photoacoustic tomography: simulations and experiments.

    abstract::In this paper we describe a method for quantitative photoacoustic tomography (qPAT) based on the photon radiative transfer equation (RTE) coupled with the Helmholtz photoacoustic wave equation. Considerable simulations and tissue-like phantom experiments are conducted to evaluate transport-based qPAT in comparison wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/009

    authors: Yao L,Sun Y,Jiang H

    更新日期:2010-04-07 00:00:00

  • Feasibility of polymer gel-based measurements of radiation isocenter accuracy in magnetic fields.

    abstract::For conventional irradiation devices, the radiation isocenter accuracy is determined by star shot measurements on films. In magnetic resonance (MR)-guided radiotherapy devices, the results of this test may be altered by the magnetic field and the need to align the radiation and imaging isocenter may require a modifica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac228

    authors: Dorsch S,Mann P,Lang C,Haering P,Runz A,Karger CP

    更新日期:2018-05-29 00:00:00

  • Suitability of EBT3 GafChromic film for quality assurance in MR-guided radiotherapy at 0.35 T with and without real-time MR imaging.

    abstract::The 0.35 T 60Co MRIdian system (ViewRay Inc., Mountain View) has been in clinical use in our institution since May 2016. For quality assurance (QA) of dose delivery and end-to-end testing for this machine, a reliable dosimeter is required. However, it is possible that a magnetic field may cause perturbations to dosime...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad58d

    authors: Barten DLJ,Hoffmans D,Palacios MA,Heukelom S,van Battum LJ

    更新日期:2018-08-20 00:00:00

  • Recovery of total I-131 activity within focal volumes using SPECT and 3D OSEM.

    abstract::We experimentally investigated the SPECT recovery of I-131 activity in multiple spheres located simultaneously at different locations within a cylindrical phantom that had an elliptical cross section. The sphere volumes ranged from 209 cc down to 4.2 cc. A Prism 3000 camera and two types of parallel-hexagonal-hole col...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/3/017

    authors: Koral KF,Yendiki A,Dewaraja YK

    更新日期:2007-02-07 00:00:00

  • Out-of-field doses from pediatric craniospinal irradiations using 3D-CRT, IMRT, helical tomotherapy and electron-based therapy.

    abstract::Medulloblastoma treatment involves irradiation of the entire central nervous system, i.e. craniospinal irradiation (CSI). This is associated with the significant exposure of large volumes of healthy tissue and there is growing concern regarding treatment-associated side effects. The current study compares out-of-field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6c9e

    authors: De Saint-Hubert M,Verellen D,Poels K,Crijns W,Magliona F,Depuydt T,Vanhavere F,Struelens L

    更新日期:2017-07-07 00:00:00

  • Thresholds for visual detection of Young's modulus contrast in simulated ultrasound image movies.

    abstract::Elasticity imaging (EI) is being developed to allow the evaluation of the mechanical properties of soft tissue, but these properties are already assessed in routine ultrasound breast examination using a method that involves the subjective interpretation of tissue motion seen in real-time B-mode image movies during pal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/301

    authors: Miller NR,Bamber JC

    更新日期:2000-08-01 00:00:00

  • Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

    abstract::Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4665

    authors: Nasr AT,Alexander K,Schreiner LJ,McAuley KB

    更新日期:2015-06-21 00:00:00

  • Developing a 'multiPatchPET' system in GATE for a PET system design with irregular geometries.

    abstract::This work modified the commonly used Monte Carlo tool package GATE by developing a new 'multiPatchPET' system so that GATE users can easily simulate PET systems with irregular geometries. The motivation was to design a brain PET scanner with high sensitivity. It is known that compact PET scanners with a large solid co...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad8fd

    authors: Chen G,Weng F,Hong X,Tao W,Zhao Z,Peng Q,Huang Q

    更新日期:2018-09-06 00:00:00