Arc-modulated radiation therapy based on linear models.

Abstract:

:This paper reports an inverse arc-modulated radiation therapy planning technique based on linear models. It is implemented with a two-step procedure. First, fluence maps for 36 fixed-gantry beams are generated using a linear model-based intensity-modulated radiation therapy (IMRT) optimization algorithm. The 2D fluence maps are decomposed into 1D fluence profiles according to each leaf pair position. Second, a mixed integer linear model is used to construct the leaf motions of an arc delivery that reproduce the 1D fluence profile previously derived from the static gantry IMRT optimization. The multi-leaf collimator (MLC) sequence takes into account the starting and ending leaf positions in between the neighbouring apertures, such that the MLC segments of the entire treatment plan are deliverable in a continuous arc. Since both steps in the algorithm use linear models, implementation is simple and straightforward. Details of the algorithm are presented, and its conceptual correctness is verified with clinical cases representing prostate and head-and-neck treatments.

journal_name

Phys Med Biol

authors

Zhu X,Thongphiew D,McMahon R,Li T,Chankong V,Yin FF,Wu QJ

doi

10.1088/0031-9155/55/13/020

subject

Has Abstract

pub_date

2010-07-07 00:00:00

pages

3873-83

issue

13

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(10)45769-3

journal_volume

55

pub_type

杂志文章
  • Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

    abstract::Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/947

    authors: Cao Q,Thawait G,Gang GJ,Zbijewski W,Reigel T,Brown T,Corner B,Demehri S,Siewerdsen JH

    更新日期:2015-02-07 00:00:00

  • Impact of attenuation correction strategies on the quantification of High Resolution Research Tomograph PET studies.

    abstract::In this study, the quantitative accuracy of different attenuation correction strategies presently available for the High Resolution Research Tomograph (HRRT) was investigated. These attenuation correction methods differ in reconstruction and processing (segmentation) algorithms used for generating a micro-image from m...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/1/007

    authors: van Velden FH,Kloet RW,van Berckel BN,Molthoff CF,de Jong HW,Lammertsma AA,Boellaard R

    更新日期:2008-01-07 00:00:00

  • A Monte Carlo investigation of contaminant electrons due to a novel in vivo transmission detector.

    abstract::A novel transmission detector (IBA Dosimetry, Germany) developed as an IMRT quality assurance tool, intended for in vivo patient dose measurements, is studied here. The goal of this investigation is to use Monte Carlo techniques to characterize treatment beam parameters in the presence of the detector and to compare t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/020

    authors: Asuni G,Jensen JM,McCurdy BM

    更新日期:2011-02-21 00:00:00

  • Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology.

    abstract::We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/1/241

    authors: van Engelen A,Niessen WJ,Klein S,Groen HC,Verhagen HJ,Wentzel JJ,van der Lugt A,de Bruijne M

    更新日期:2012-01-07 00:00:00

  • Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

    abstract::The purpose of this work was to create a computational platform for studying motion in intensity modulated radiotherapy (IMRT). Specifically, the non-uniform rational B-spline (NURB) cardiac and torso (NCAT) phantom was modified for use in a four-dimensional Monte Carlo (4D-MC) simulation system to investigate the eff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/5/014

    authors: McGurk R,Seco J,Riboldi M,Wolfgang J,Segars P,Paganetti H

    更新日期:2010-03-07 00:00:00

  • Superpixel-based and boundary-sensitive convolutional neural network for automated liver segmentation.

    abstract::Segmentation of liver in abdominal computed tomography (CT) is an important step for radiation therapy planning of hepatocellular carcinoma. Practically, a fully automatic segmentation of liver remains challenging because of low soft tissue contrast between liver and its surrounding organs, and its highly deformable s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabd19

    authors: Qin W,Wu J,Han F,Yuan Y,Zhao W,Ibragimov B,Gu J,Xing L

    更新日期:2018-05-04 00:00:00

  • The Monte Carlo calculation of integral radiation dose in xeromammography.

    abstract::A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/003

    authors: Dance DR

    更新日期:1980-01-01 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams.

    abstract::The implementation of two algorithms for calculating dose distributions for radiation therapy treatment planning of intermediate energy proton beams is described. A pencil kernel algorithm and a depth penetration algorithm have been incorporated into a commercial three dimensional treatment planning system (Helax-TMS,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/1/302

    authors: Russell KR,Isacsson U,Saxner M,Ahnesjö A,Montelius A,Grusell E,Dahlgren CV,Lorin S,Glimelius B

    更新日期:2000-01-01 00:00:00

  • Temporal backward projection of optoacoustic pressure transients using fourier transform methods.

    abstract::In medical imaging different techniques have been developed to gain information from inside a tissue. Optoacoustics is a method to generate tomography pictures of tissue using Q-switched laser pulses. Due to thermal and pressure confinement, a short light pulse generates a pressure distribution inside tissue, which mi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/309

    authors: Köstli KP,Frenz M,Bebie H,Weber HP

    更新日期:2001-07-01 00:00:00

  • 1D dynamic beam modulation: methods to counteract inertia effects.

    abstract::Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/401

    authors: Corletto D,Broggi S,Fiorino C,Mangili P,Calandrino R,Lev A,Gennari D,Rudello F

    更新日期:1999-11-01 00:00:00

  • Effect of material property heterogeneity on biomechanical modeling of prostate under deformation.

    abstract::Biomechanical model based deformable image registration has been widely used to account for prostate deformation in various medical imaging procedures. Biomechanical material properties are important components of a biomechanical model. In this study, the effect of incorporating tumor-specific material properties in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/1/195

    authors: Samavati N,McGrath DM,Jewett MA,van der Kwast T,Ménard C,Brock KK

    更新日期:2015-01-07 00:00:00

  • Coupled thermo-electro-mechanical models for thermal ablation of biological tissues and heat relaxation time effects.

    abstract::Thermal ablation is a widely applied electrosurgical process in medical treatment of soft biological tissues. Numerical modeling and simulations play an important role in prediction of temperature distribution and damage volume during the treatment planning stage of associated therapies. In this contribution we report...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4cc5

    authors: Singh S,Melnik R

    更新日期:2019-12-13 00:00:00

  • Cone-beam CT using a mobile C-arm: a registration solution for IGRT with an optical tracking system.

    abstract::A method for registering images acquired from a prototype flat panel mobile C-arm, capable of kilovoltage (kV) cone-beam computed tomography (CT), to a linear accelerator (LINAC) isocenter is presented. A calibration procedure is performed which involves locating reflective markers placed on the C-arm and a phantom in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/12/005

    authors: Sorensen S,Mitschke M,Solberg T

    更新日期:2007-06-21 00:00:00

  • Algorithm and performance of a clinical IMRT beam-angle optimization system.

    abstract::This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/19/007

    authors: Djajaputra D,Wu Q,Wu Y,Mohan R

    更新日期:2003-10-07 00:00:00

  • The integration of DVH-based planning aspects into a convex intensity modulated radiation therapy optimization framework.

    abstract::The formulation of intensity modulated radiation therapy (IMRT) planning aspects frequently uses the dose-volume histogram (DVH), whereas plan computations often happen in the more desirable convex IMRT optimization framework. Inspired by a recent publication of Zinchenko et al (2008 Phys. Med. Biol. 53 3231-50), this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/12/N02

    authors: Kratt K,Scherrer A

    更新日期:2009-06-21 00:00:00

  • Three-dimensional cellular-level imaging using full-field optical coherence tomography.

    abstract::An ultrahigh-resolution full-field optical coherence tomography (OCT) system has been developed for cellular-level imaging of biological media. The system is based on a Linnik interference microscope illuminated with a tungsten halogen lamp, associated with a high-resolution CCD camera. En face tomographic images are ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/010

    authors: Dubois A,Moneron G,Grieve K,Boccara AC

    更新日期:2004-04-07 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • Automated prostate segmentation in whole-body MRI scans for epidemiological studies.

    abstract::The whole prostatic volume (PV) is an important indicator for benign prostate hyperplasia. Correlating the PV with other clinical parameters in a population-based prospective cohort study (SHIP-2) requires valid prostate segmentation in a large number of whole-body MRI scans. The axial proton density fast spin echo fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5899

    authors: Habes M,Schiller T,Rosenberg C,Burchardt M,Hoffmann W

    更新日期:2013-09-07 00:00:00

  • Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation.

    abstract:PURPOSE:A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. M...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abde96

    authors: Zhang X,Uneri A,Wu P,Ketcha MD,Jones C,Huang Y,Lo SL,Helm PA,Siewerdsen JH

    更新日期:2021-01-21 00:00:00

  • Correlation between human and model observer performance for discrimination task in CT.

    abstract::Although physical metrics can objectively characterize computed tomography (CT) image quality, quantitative approaches to predict human observer performance are more accurate and clinically relevant. This study compared a modified channelized Hotelling model observer (CHO) with human observers in a shape discriminatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/13/3389

    authors: Zhang Y,Leng S,Yu L,Carter RE,McCollough CH

    更新日期:2014-07-07 00:00:00

  • Evaluation of multiple-sphere head models for MEG source localization.

    abstract::Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-spher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/010

    authors: Lalancette M,Quraan M,Cheyne D

    更新日期:2011-09-07 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00

  • Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors.

    abstract::Monte Carlo simulation was used to calculate correction factors for output factor (OF), percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife M6 System. These include the first such data for the InCise MLC. Simulated detectors include diodes, air-filled microchambers, a synthetic micro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5610

    authors: Francescon P,Kilby W,Noll JM,Masi L,Satariano N,Russo S

    更新日期:2017-02-07 00:00:00

  • Automatic classification of DMSA scans using an artificial neural network.

    abstract::DMSA imaging is carried out in nuclear medicine to assess the level of functional renal tissue in patients. This study investigated the use of an artificial neural network to perform diagnostic classification of these scans. Using the radiological report as the gold standard, the network was trained to classify DMSA s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1789

    authors: Wright JW,Duguid R,McKiddie F,Staff RT

    更新日期:2014-04-07 00:00:00

  • Arranging optical fibres for the spatial resolution improvement of topographical images.

    abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/311

    authors: Yamamoto T,Maki A,Kadoya T,Tanikawa Y,Yamad Y,Okada E,Koizumi H

    更新日期:2002-09-21 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • Reply to comment on 'origins of the changing detector response in small megavoltage photon radiation fields'.

    abstract::Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) have disputed a finding of Scott et al (2012 Phys. Med. Biol. 57 4461-76) that the variation with field-size of the response of small ion chambers and solid-state dosimeters in small megavoltage photon radiation fields can largely be attributed to density. Furt...

    journal_title:Physics in medicine and biology

    pub_type: 评论,杂志文章

    doi:10.1088/1361-6560/aae0e4

    authors: Fenwick JD,Georgiou G,Rowbottom CG,Underwood TSA,Kumar S

    更新日期:2018-10-03 00:00:00