Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation.

Abstract:

PURPOSE:A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. METHODS:A multi-slot collimator with tilted apertures was integrated into an O-arm system for long-length imaging. The multi-slot projective geometry leads to slight view disparity in both long-length projection images (referred to as "line scans") and tomosynthesis "slot reconstructions" produced using a weighted-backprojection method. The radiation dose for long-length imaging was measured, and the utility of long-length, intraoperative tomosynthesis was evaluated in phantom and cadaver studies. Leveraging the depth resolution provided by parallax views, an algorithm for 3D-2D registration of the patient and surgical devices was adapted for registration with line scans and slot reconstructions. Registration performance using single-plane or dual-plane long-length images was evaluated and compared to registration accuracy achieved using standard biplane radiographs. RESULTS:Longitudinal coverage of ~50-64 cm was achieved with a single long-length slot scan, providing a field-of-view up to (40 × 64) cm2, depending on patient positioning. The dose-area product (reference point air kerma × x-ray field area) for a slot scan ranged from ~702-1757 mGy ⋅ cm2, equivalent to ~2.5 s of fluoroscopy and comparable to other long-length imaging systems. Long-length scanning produced high-resolution tomosynthesis reconstructions, covering ~12-16 vertebral levels. 3D image registration using dual-plane slot reconstructions achieved median target registration error (TRE) of 1.2 mm and 0.6° in cadaver studies, outperforming registration to line scans (TRE = 2.8 mm and 2.2°) and biplane radiographs (TRE = 2.5 mm and 1.1°). 3D registration using single-plane slot reconstructions leveraged the ~7-14° angular separation between slots to achieve median TRE ~2 mm and < 2° from a single scan. CONCLUSION:The multi-slot configuration provided intraoperative visualization of long spine segments, facilitating target localization, assessment of global spinal alignment, and evaluation of long surgical constructs. 3D-2D registration to long-length tomosynthesis reconstructions yielded a promising means of guidance and verification with accuracy exceeding that of 3D-2D registration to conventional radiographs.

journal_name

Phys Med Biol

authors

Zhang X,Uneri A,Wu P,Ketcha MD,Jones C,Huang Y,Lo SL,Helm PA,Siewerdsen JH

doi

10.1088/1361-6560/abde96

subject

Has Abstract

pub_date

2021-01-21 00:00:00

eissn

0031-9155

issn

1361-6560

pub_type

杂志文章
  • Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device.

    abstract::This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel pha...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2582

    authors: Grasland-Mongrain P,Miller-Jolicoeur E,Tang A,Catheline S,Cloutier G

    更新日期:2016-03-21 00:00:00

  • Assessment of the exposure to biologically effective UV radiation using a dosimetric technique to evaluate the solar spectrum.

    abstract::A cost-effective method employing polysulphone, nalidixic acid, 8-methoxypsoralen and phenothiazine as UV dosimeters is presented for evaluating the UV spectrum. The exposure measured by each dosimeter is a function of the source spectrum and the spectral response of the material. Each material has a different spectra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/005

    authors: Parisi AV,Wong JC,Moore GI

    更新日期:1997-01-01 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Production of clinically useful positron emitter beams during carbon ion deceleration.

    abstract::In external beam radiation therapy, radioactive beams offer the best clinical solution to simultaneously treat and in vivo monitor the dose delivery and tumor response using PET or PET-CT imaging. However, difficulties mainly linked to the low production efficiency have so far limited their use. This study is devoted ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/6/005

    authors: Lazzeroni M,Brahme A

    更新日期:2011-03-21 00:00:00

  • A temperature-based feedback control system for electromagnetic phased-array hyperthermia: theory and simulation.

    abstract::A hybrid proportional-integral-in-time and cost-minimizing-in-space feedback control system for electromagnetic, deep regional hyperthermia is proposed. The unique features of this controller are that (1) it uses temperature, not specific absorption rate, as the criterion for selecting the relative phases and amplitud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/5/306

    authors: Kowalski ME,Jin JM

    更新日期:2003-03-07 00:00:00

  • Intensity of the flash associated with laser-induced plasma in the eye.

    abstract::A bright flash of light is emitted by the plasma formed at the focus of an ophthalmic Nd: YAG laser. The purpose of this investigation is to determine whether the plasma flash constitutes a hazard to the operator. The intensity of the flash at the slit lamp eyepiece was measured and the experimentally derived value wa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/9/009

    authors: Moseley H,Allan D

    更新日期:1987-09-01 00:00:00

  • Substituting gelatine with Pluronic F-127 matrix in 3D polymer gel dosimeters can improve nuclear magnetic resonance, thermal and optical properties.

    abstract::This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPARnd (VIP) and VIPARCT (VIC). The current research outcomes s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9d5

    authors: Jaszczak M,Wach R,Maras P,Dudek M,Kozicki M

    更新日期:2018-09-06 00:00:00

  • Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    abstract::A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/14/5413

    authors: Abuhaimed A,Martin CJ,Sankaralingam M,Gentle DJ

    更新日期:2015-07-21 00:00:00

  • Comparison of large-area position-sensitive solid-state photomultipliers for small animal PET.

    abstract::This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SS...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/24/8119

    authors: Schmall JP,Du J,Yang Y,Dokhale PA,McClish M,Christian J,Shah KS,Cherry SR

    更新日期:2012-12-21 00:00:00

  • The impact of morphology on light transport in cancellous bone.

    abstract::In recent years, optical techniques based on diffusion approximation have demonstrated their ability to gain rich spectral information about bone. However, these methods normally assume homogeneity, while cancellous bone and marrow form a highly heterogeneous two-phase medium. This paper studies the limitations of thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/17/003

    authors: Margallo-Balbás E,Taroni P,Pifferi A,Koolstra JH,v Ruijven LJ,French PJ

    更新日期:2010-09-07 00:00:00

  • Improving single-event proton CT by removing nuclear interaction events within the energy/range detector.

    abstract::Data filtering is crucial for accurate relative stopping power (RSP) reconstruction in proton CT (pCT). In this work, we assess different filters and their performance for the US pCT collaboration prototype pCT system in Monte Carlo (MC) simulations. The potential of using the recently proposed [Formula: see text]-E f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2671

    authors: Volz L,Piersimoni P,Johnson RP,Bashkirov VA,Schulte RW,Seco J

    更新日期:2019-08-01 00:00:00

  • A model-based approach to investigate the effect of elevated interstitial fluid pressure on strain elastography.

    abstract::Finite element (FE) modeling provides a useful tool to understand the mechanical behavior of complex tissues, such as cancers, in a variety of testing conditions. Although a number of numerical and analytical models for cancerous tumors are retrievable in the literature, none of these models is capable of completely d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aae572

    authors: Islam MT,Reddy JN,Righetti R

    更新日期:2018-10-24 00:00:00

  • Ionization chamber volume determination and quality assurance using micro-CT imaging.

    abstract::Ion chamber dosimetry requires a high degree of precision, at all steps within the dosimetric process, in order to ensure accurate dose measurements. This work presents a novel technique for ion chamber volume determination and quality assurance, using micro-computed tomography (micro-CT). Four nominally identical Exr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/012

    authors: McNiven AL,Umoh J,Kron T,Holdsworth DW,Battista JJ

    更新日期:2008-09-21 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • The Monte Carlo calculation of integral radiation dose in xeromammography.

    abstract::A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/003

    authors: Dance DR

    更新日期:1980-01-01 00:00:00

  • Conversion factors for the estimation of effective dose in paediatric cardiac angiography.

    abstract::Conversion factors, which relate the kerma-area product to effective dose, have been estimated for paediatric cardiac x-ray angiography. Monte Carlo techniques have been used to calculate the conversion factors for a wide range of projection angles for children of five ages and for adults. Correction factors are provi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/10/323

    authors: Schmidt PW,Dance DR,Skinner CL,Smith IA,McNeill JG

    更新日期:2000-10-01 00:00:00

  • Exact solutions to the multiregion time-dependent bioheat equation. II: Numerical evaluation of the solutions.

    abstract::Analytic solutions to the time-dependent multiregion bioheat equation are evaluated numerically for cartesian and spherical models. Principle and alternate branch contributions to the solutions are examined. The calculations include a parametric investigation and analyses of temperature behaviour in idealised upper th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/7/005

    authors: Durkee JW Jr,Antich PP,Lee CE

    更新日期:1990-07-01 00:00:00

  • Cadmium in man measured in vivo by x-ray fluorescence analysis.

    abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/004

    authors: Ahlgren L,Mattsson S

    更新日期:1981-01-01 00:00:00

  • Automatic extraction of pectoral muscle in the MLO view of mammograms.

    abstract::A mammogram is the standard modality used for breast cancer screening. Computer-aided detection (CAD) approaches are helpful for improving breast cancer detection rates when applied to mammograms. However, automated analysis of a mammogram often leads to inaccurate results in the presence of the pectoral muscle. There...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/23/8493

    authors: Feudjio CK,Klein J,Tiedeu A,Colot O

    更新日期:2013-12-07 00:00:00

  • Self-adaptive ultrasonic beam amplifiers: application to transcostal shock wave therapy.

    abstract::Ultrasound shock wave therapy is increasingly used for non-invasive surgery. It requires the focusing of very high pressure amplitude in precisely controlled focal spots. In transcostal therapy of the heart or the liver, the high impedance mismatch between the bones and surrounding tissues gives rise to strong aberrat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9b5

    authors: Robin J,Simon A,Arnal B,Tanter M,Pernot M

    更新日期:2018-09-06 00:00:00

  • Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons-a Monte Carlo simulation study.

    abstract::We propose and evaluate the performance of an improved preclinical positron emission tomography (PET) scanner design, referred to as Polaroid-PET, consisting of a detector equipped with a layer of horizontal Polaroid to filter scintillation photons with vertical polarization. This makes it possible to improve the spat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaeb8

    authors: Sanaat A,Ashrafi-Belgabad A,Zaidi H

    更新日期:2020-12-02 00:00:00

  • The influence of a clear layer on near-infrared spectrophotometry measurements using a liquid neonatal head phantom.

    abstract::It is difficult to test near-infrared spectrophotometry instruments in vivo. Therefore we constructed a liquid phantom which mimics the neonatal head. It consists of a spherical 3.5 mm thick layer of silicone rubber simulating skin and bone and a 0.5 mm thick clear layer of polypropylene imitating cerebrospinal fluid....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/313

    authors: Wolf M,Keel M,Dietz V,von Siebenthal K,Bucher HU,Baenziger O

    更新日期:1999-07-01 00:00:00

  • Automated stroke lesion segmentation in non-contrast CT scans using dense multi-path contextual generative adversarial network.

    abstract::Stroke lesion volume is a key radiologic measurement in assessing prognosis of acute ischemic stroke (AIS) patients. The aim of this paper is to develop an automated segmentation method for accurately segmenting follow-up ischemic and hemorrhagic lesion from multislice non-contrast CT (NCCT) volumes of AIS patients. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba166

    authors: Kuang H,Menon BK,Qiu W

    更新日期:2020-11-05 00:00:00

  • Development of a platform for co-registered ultrasound and MR contrast imaging in vivo.

    abstract::Imaging of the microvasculature is often performed using contrast agents in combination with either ultrasound (US) or magnetic resonance (MR) imaging. Contrast agents are used to enhance medical imaging by highlighting microvascular properties and function. Dynamic signal changes arising from the passage of contrast ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/020

    authors: Chandrana C,Bevan P,Hudson J,Pang I,Burns P,Plewes D,Chopra R

    更新日期:2011-02-07 00:00:00

  • Respiratory motion prediction by using the adaptive neuro fuzzy inference system (ANFIS).

    abstract::The quality of radiation therapy delivered for treating cancer patients is related to set-up errors and organ motion. Due to the margins needed to ensure adequate target coverage, many breast cancer patients have been shown to develop late side effects such as pneumonitis and cardiac damage. Breathing-adapted radiatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/19/020

    authors: Kakar M,Nyström H,Aarup LR,Nøttrup TJ,Olsen DR

    更新日期:2005-10-07 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Simultaneous optimization of RBE-weighted dose and nanometric ionization distributions in treatment planning with carbon ions.

    abstract::Inverse treatment planning in intensity modulated particle therapy (IMPT) with scanned carbon-ion beams is currently based on the optimization of RBE-weighted dose to satisfy requirements of target coverage and limited toxicity to organs-at-risk (OARs) and healthy tissues. There are many feasible IMPT plans that meet ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf400

    authors: Burigo LN,Ramos-Méndez J,Bangert M,Schulte RW,Faddegon B

    更新日期:2019-01-04 00:00:00

  • An image reconstruction method with a locally adaptive gating scheme for PET data.

    abstract::In conventional gating approaches for positron emission tomography (PET), a single number of gates is predetermined for the whole field of view (FOV) regardless of spatially variant motion blurring effects, which compromises image quality by under-gating regions of large motion and over-gating static regions. To achie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac71b

    authors: Wang J,Dong Y,Li H,Feng T

    更新日期:2018-08-10 00:00:00

  • Bilinear models for inter- and intra-patient variation of the prostate.

    abstract::We propose bilinear models for capturing and effectively decoupling the expected shape variations of an organ both across the patient population and within a specific patient. Bilinear models have been successfully introduced in other areas of computer vision, but they have rarely been used in medical imaging applicat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/13/010

    authors: Jeong Y,Radke RJ,Lovelock DM

    更新日期:2010-07-07 00:00:00