Abstract:
:Monte Carlo simulation was used to calculate correction factors for output factor (OF), percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife M6 System. These include the first such data for the InCise MLC. Simulated detectors include diodes, air-filled microchambers, a synthetic microdiamond detector, and point scintillator. Individual perturbation factors were also evaluated. OF corrections show similar trends to previous studies. With a 5 mm fixed collimator the diode correction to convert a measured OF to the corresponding point dose ratio varies between -6.1% and -3.5% for the diode models evaluated, while in a 7.6 mm × 7.7 mm MLC field these are -4.5% to -1.8%. The corresponding microchamber corrections are +9.9% to +10.7% and +3.5% to +4.0%. The microdiamond corrections have a maximum of -1.4% for the 7.5 mm and 10 mm collimators. The scintillator corrections are <1% in all beams. Measured OF showed uncorrected inter-detector differences >15%, reducing to <3% after correction. PDD corrections at d > d max were <2% for all detectors except IBA Razor where a maximum 4% correction was observed at 300 mm depth. OAR corrections were smaller inside the field than outside. At the beam edge microchamber OAR corrections were up to 15%, mainly caused by density perturbations, which blurs the measured penumbra. With larger beams and depths, PTW and IBA diode corrections outside the beam were up to 20% while the Edge detector needed smaller corrections although these did vary with orientation. These effects are most noticeable for large field size and depth, where they are dominated by fluence and stopping power perturbations. The microdiamond OAR corrections were <3% outside the beam. This paper provides OF corrections that can be used for commissioning new CyberKnife M6 Systems and retrospectively checking estimated corrections used previously. We recommend the PDD and OAR corrections are used to guide detector selection and inform the evaluation of results rather than to explicitly correct measurements.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Francescon P,Kilby W,Noll JM,Masi L,Satariano N,Russo Sdoi
10.1088/1361-6560/aa5610subject
Has Abstractpub_date
2017-02-07 00:00:00pages
1076-1095issue
3eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/5/021
更新日期:1998-05-01 00:00:00
abstract::Noise equivalent count rate (NECR) and image noise are two different but related metrics that have been used to predict and assess image quality, respectively. The aim of this study is to investigate, using patient studies, the relationships between injected dose (ID), body mass index (BMI) and scanner type on NECR an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/16/013
更新日期:2011-08-21 00:00:00
abstract::Computational simulations, such as Monte Carlo track structure simulations, offer a powerful tool for quantitatively investigating radiation interactions within cells. The modelling of the spatial distribution of energy deposition events as well as diffusion of chemical free radical species, within realistic biologica...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad8eb
更新日期:2018-09-06 00:00:00
abstract::A method of radiation dosimetry is described which is based on the radiation-induced initiation of polymerization of a bulk monomer (e.g. methyl methacrylate) containing a small concentration (about 100 ppm) of a compound which is non-fluorescent but which becomes highly fluorescent when it is incorporated into a grow...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/10/015
更新日期:2009-05-21 00:00:00
abstract::Dual energy computed tomography (DECT) is currently a subject of extensive investigation. DECT is currently implemented using either a dual source scanner with high and low kVp data acquired from separate sources or a single source scanner with both high and low kVp data acquired in an alternating manner. Both methods...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/21/005
更新日期:2010-11-07 00:00:00
abstract::Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newl...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/9/2441
更新日期:2012-05-07 00:00:00
abstract::This paper analyzes the radio frequencies (RF) exposure in the head tissues of children using a cellular handset or RF sources (a dipole and a generic handset) at 900, 1800, 2100 and 2400 MHz. Based on magnetic resonance imaging, child head models have been developed. The maximum specific absorption rate (SAR) over 10...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/13/019
更新日期:2008-07-07 00:00:00
abstract::Factors influencing the precision of measuring changes in the calcium content of sections of bone, including vertebrae, using reactor neutrons for partial body in vivo activation analysis have been examined and quantified. These factors include (a) the choice of incidient neutron spectrum, (b) the uniformity of activa...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/20/1/007
更新日期:1975-01-01 00:00:00
abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aafcdb
更新日期:2019-02-05 00:00:00
abstract::To address the quality assurance (QA) of a MR-linac which is an MRI combined with a linear accelerator (linac), the traditional linac QA-tests need to be redesigned, since the presence of the static magnetic field in the MR-linac alters the electron trajectory. The latter causes the asymmetry in the dose kernel which ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/3/N50
更新日期:2016-02-07 00:00:00
abstract::The function of the placenta is challenging to characterize and as a result is understudied, despite the growing awareness of the impact of the placental environment on human health and development. Medical imaging has the potential to improve our ability to screen for diseases associated with placental insufficiency,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/1361-6560/aaccd9
更新日期:2018-07-09 00:00:00
abstract::For low-energy (up to 150 kV) x-rays, the ratio of mass-energy absorption coefficients for water to air, (mu(en)/rho)w.air, and the backscatter factor B are used in the conversion of air kerma, measured free-in-air, to water kerma on the surface of a water phantom. For clinical radiotherapy, similar conversion factors...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/1/011
更新日期:1999-01-01 00:00:00
abstract::In this study, an induced electric field in a human body is evaluated for the magnetic field leaked from a wireless power transfer system for charging an electrical vehicle. The magnetic field from the wireless power transfer system is modelled computationally, and its effectiveness is confirmed by comparison with the...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/21/7583
更新日期:2013-11-07 00:00:00
abstract::Few quantitative data are available on the kinetics of polymerization reactions in polymer gel (PAG) dosimeters and their long-term stability. Post-irradiation polymerization reactions have been found to continue for several weeks, posing questions regarding dosimeter stability and its achievement. In this paper we re...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/8/301
更新日期:1999-08-01 00:00:00
abstract::The goal of this study was to assess the impact of set-up uncertainty on compliance with the objectives and constraints of an intensity modulated radiation therapy protocol for early stage cancer of the oropharynx. As the convolution approach to the quantitative study of set-up uncertainties cannot accommodate either ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/15/003
更新日期:2005-08-07 00:00:00
abstract::Gold nanoparticles (GNPs) have shown potential in recent years as a means of therapeutic dose enhancement in radiation therapy. However, a major challenge in moving towards clinical implementation is the exact characterisation of the dose enhancement they provide. Monte Carlo studies attempt to explore this property, ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/5/2014
更新日期:2016-03-07 00:00:00
abstract::The distribution and transport of Hippuran is discussed. The activity leaving both kidneys has been calculated and compared with the bladder activity. It is shown that the Impulse Response Function of the ureter and bladder may be obtained by deconvolution, and data are presented relating to studies on one patient. ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/26/2/002
更新日期:1981-03-01 00:00:00
abstract::The theory of task-based assessment of image quality is reviewed in the context of imaging with ionizing radiation, and objective figures of merit (FOMs) for image quality are summarized. The variation of the FOMs with the task, the observer and especially with the mean number of photons recorded in the image is discu...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/60/2/R1
更新日期:2015-01-21 00:00:00
abstract::A method of measuring the image quality of medical imaging equipment is considered within the framework of statistical decision theory. In this approach, images are regarded as random vectors and image quality is defined in the context of the image information available for performing a specified detection or discrimi...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/1/006
更新日期:1993-01-01 00:00:00
abstract::A non-contact approach for diffuse optical tomography (DOT) has been developed for on-demand image updates using surgical navigation technology. A stereoscopic optical tracker provides real-time localization of reflective spheres mounted to a laser diode and near-infrared camera. Standard camera calibration is combine...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab1f33
更新日期:2019-07-05 00:00:00
abstract::A technique is presented to allow a breathing pattern to be obtained from any multi-slice CT, cone-beam or other series of sequential chest x-ray image sets. The technique requires no extra signals to be recorded and does not need specific external or internal oscillating structures to be visible in the field of view....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/16/003
更新日期:2009-08-21 00:00:00
abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7105
更新日期:2020-03-06 00:00:00
abstract::For PET online data acquisition, a centralized coincidence processor (CCP) with a single-thread data processing has been used to select coincidence events for many PET scanners. CCP has the advantage of highly integrated circuit, compact connection between detector front-end and system electronics, and centralized con...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abde85
更新日期:2021-01-21 00:00:00
abstract::It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The purpose of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/10/309
更新日期:2002-05-21 00:00:00
abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/32/10/010
更新日期:1987-10-01 00:00:00
abstract::An acardiac twin is a severely malformed monochorionic twin fetus that lacks most organs, particularly a heart. It grows during pregnancy, because it is perfused by its developmentally normal co-twin (called the pump twin) via a set of placental arterioarterial and venovenous anastomoses. The pump twin dies intrauteri...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/14/n01
更新日期:2004-07-21 00:00:00
abstract::The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/10/n209
更新日期:2015-05-21 00:00:00
abstract::Ultrasound in the low megahertz frequency range is used by physiotherapists to treat a variety of conditions. The treatments reduce swelling, reduce pain and increase movement at joints. Ultrasound is now also beginning to be used to treat malignant tumours. The tumours are heated to temperatures between 42 degrees an...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/34/11/019
更新日期:1989-11-01 00:00:00
abstract::In radiotherapy with photon beams, the use of dynamic wedges, which are obtained by the movement of one of the jaws, offers an increasing flexibility relative to the traditional use of metal wedges. But it is a disadvantage for the measurement of absorbed dose distributions, because the absorbed dose at each measureme...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/6/009
更新日期:1998-06-01 00:00:00
abstract::Most commonly in radiation therapy, treatments are delivered in a co-planar geometry. Numerous advantages have been reported of adding non-coplanar beams to the treatment plan. The aim of this study was to compare current state-of-the-art VMAT and CyberKnife treatment plans to that of a novel linac design developed at...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab246f
更新日期:2019-06-20 00:00:00