Mass-energy absorption coefficient and backscatter factor ratios for kilovoltage x-ray beams.

Abstract:

:For low-energy (up to 150 kV) x-rays, the ratio of mass-energy absorption coefficients for water to air, (mu(en)/rho)w.air, and the backscatter factor B are used in the conversion of air kerma, measured free-in-air, to water kerma on the surface of a water phantom. For clinical radiotherapy, similar conversion factors are needed for the determination of the absorbed dose to biological tissues on (or near) the surface of a human body. We have computed the mu(en)/rho ratios and B factor ratios for different biological tissues including muscle, soft tissue, lung, skin and bone relative to water. The mu(en)/rho ratios were obtained by integrating the respective mass-energy absorption coefficients over the in-air primary photon spectra. We have also calculated the mu(en)/rho ratios at different depths in a water phantom in order to convert the measured in-phantom water kerma to the absorbed dose to various biological tissues. The EGS4/DOSIMETER Monte Carlo code system has been used for the simulation of the energy fluence at different depths in a water phantom irradiated by a kilovoltage x-ray beam of variable beam quality (HVL: 0.1 mm Al-5 mm Cu), field size and source-surface distance (SSD). The same code was also used in the calculation of the B factor ratios, soft tissue to water and bone to water. The results show that the B factor for bone differs from the B factor for water by up to 20% for a 100 kV beam (HVL: 2.65 mm Al) with a 100 cm2 field. On the other hand, the difference in the B factor between water and soft tissue is insignificant (well within 1% generally). This means that the B factors for water may be directly used to convert the 'in-air' water kerma to surface kerma for human soft tissues.

journal_name

Phys Med Biol

authors

Ma CM,Seuntjens JP

doi

10.1088/0031-9155/44/1/011

subject

Has Abstract

pub_date

1999-01-01 00:00:00

pages

131-43

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

44

pub_type

杂志文章
  • Multiobjective evolutionary optimization of the number of beams, their orientations and weights for intensity-modulated radiation therapy.

    abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/007

    authors: Schreibmann E,Lahanas M,Xing L,Baltas D

    更新日期:2004-03-07 00:00:00

  • 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.

    abstract::Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/749

    authors: Chin E,Loewen SK,Nichol A,Otto K

    更新日期:2013-02-21 00:00:00

  • On the impact of longitudinal breathing motion randomness for tomotherapy delivery.

    abstract::The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing. This explanation is developed by the use of longitudinal (1D) simulations of mock and surrogate data and tested with a fully 4D ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/001

    authors: Kissick MW,Flynn RT,Westerly DC,Hoban PW,Mo X,Soisson ET,McCall KC,Mackie TR,Jeraj R

    更新日期:2008-09-21 00:00:00

  • An investigation into the vector ellipticity of extremely low frequency magnetic fields from appliances in UK homes.

    abstract::Elliptically polarized magnetic fields induce higher currents in the body compared with their plane polarized counterparts. This investigation examines the degree of vector ellipticity of extremely low frequency magnetic fields (ELF-MFs) in the home, with regard to the adverse health effects reportedly associated with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/016

    authors: Ainsbury EA,Conein E,Henshaw DL

    更新日期:2005-07-07 00:00:00

  • Inverse treatment planning using volume-based objective functions.

    abstract::The results of optimization of inverse treatment plans depend on a choice of the objective function. Even when the optimal solution for a given cost function can be obtained, a better solution may exist for a given clinical scenario and it could be obtained with a revised objective function. In the approach presented ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/12/003

    authors: Bednarz G,Michalski D,Anne PR,Valicenti RK

    更新日期:2004-06-21 00:00:00

  • Influence of beam characteristics and detector size in negative-pion dose studies.

    abstract::Dose calculations were performed for a tissue phantom irradiated by uniform circular beams of negative pions with an assumed gaussian momentum distribution. The mean momentum of the pions was varied from 104.4 to 171.5 MeV/c (mean range 5-20 cm in unit-density tissue) and the momentum spread from 0 to 5% of the mean. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/3/012

    authors: Hamm RN,Wright HA,Turner JE

    更新日期:1979-05-01 00:00:00

  • Benchmarking GATE/Geant4 for 16O ion beam therapy.

    abstract::Oxygen ([Formula: see text]) ions are a potential alternative to carbon ions in ion beam therapy. Their enhanced linear energy transfer indicates a higher relative biological effectiveness and a reduced oxygen enhancement ratio. Due to the limited availability of [Formula: see text] ion beams, Monte Carlo (MC) transpo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa807e

    authors: Resch AF,Fuchs H,Georg D

    更新日期:2017-09-05 00:00:00

  • Dosimetry robustness with stochastic optimization.

    abstract::All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/010

    authors: Nohadani O,Seco J,Martin BC,Bortfeld T

    更新日期:2009-06-07 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.

    abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7905

    authors: Bernatowicz K,Lomax AJ,Knopf A

    更新日期:2013-11-21 00:00:00

  • A finite element method for the determination of the relative response of ionization chambers in MR-linacs: simulation and experimental validation up to 1.5 T.

    abstract::In magnetic resonance (MR) guided radiotherapy, the magnetic field-dependent change in the dose response of ionization chambers is typically included by means of a correction factor [Formula: see text]. This factor can be determined experimentally or calculated by means of Monte Carlo (MC) simulations. To date, a smal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2837

    authors: Pojtinger S,Kapsch RP,Dohm OS,Thorwarth D

    更新日期:2019-07-04 00:00:00

  • Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study.

    abstract::We show how the spectral imaging framework should be modified to account for a high fraction of Compton interactions in low Z detector materials such as silicon. Using this framework, where deposited energies differ from actual photon energies, we compare the performance of a silicon strip detector, including the infl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/7/014

    authors: Bornefalk H,Danielsson M

    更新日期:2010-04-07 00:00:00

  • FPGA-based distributed coincidence processor for high count-rate online PET coincidence data acquisition.

    abstract::For PET online data acquisition, a centralized coincidence processor (CCP) with a single-thread data processing has been used to select coincidence events for many PET scanners. CCP has the advantage of highly integrated circuit, compact connection between detector front-end and system electronics, and centralized con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abde85

    authors: Cheng X,Hu K,Yang D,Shao Y

    更新日期:2021-01-21 00:00:00

  • Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators.

    abstract::The measurement of beam data for dynamic wedge dosimetry requires the integration of radiation dose at points across the radiation field during the dose delivery. The different measurement techniques required when using a linear diode array to measure beam profiles and when using ionization chambers to measure depth d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/3/005

    authors: Bidmead AM,Garton AJ,Childs PJ

    更新日期:1995-03-01 00:00:00

  • Single-shot K-edge subtraction x-ray discrete computed tomography with a polychromatic source and the Pixie-III detector.

    abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7105

    authors: Brun F,Di Trapani V,Albers J,Sacco P,Dreossi D,Brombal L,Rigon L,Longo R,Mittone A,Dullin C,Bravin A,Delogu P

    更新日期:2020-03-06 00:00:00

  • Dose-volume histogram prediction using density estimation.

    abstract::Knowledge of what dose-volume histograms can be expected for a previously unseen patient could increase consistency and quality in radiotherapy treatment planning. We propose a machine learning method that uses previous treatment plans to predict such dose-volume histograms. The key to the approach is the framing of d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/17/6923

    authors: Skarpman Munter J,Sjölund J

    更新日期:2015-09-07 00:00:00

  • The response of cells in culture to fractionated radiation: a theoretical approach.

    abstract::A mathematical model has been constructed to simulate the response of cells in vitro to fractionated doses of radiation. The model is capable of describing most of the radiobiological functions that are commonly studied. Input data are measurable cell properties. The details of the model and methods of acquiring the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/5/011

    authors: Niederer J,Cunningham JR

    更新日期:1976-09-01 00:00:00

  • MR-guided transcranial brain HIFU in small animal models.

    abstract::Recent studies have demonstrated the feasibility of transcranial high-intensity focused ultrasound (HIFU) therapy in the brain using adaptive focusing techniques. However, the complexity of the procedures imposes provision of accurate targeting, monitoring and control of this emerging therapeutic modality in order to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/2/003

    authors: Larrat B,Pernot M,Aubry JF,Dervishi E,Sinkus R,Seilhean D,Marie Y,Boch AL,Fink M,Tanter M

    更新日期:2010-01-21 00:00:00

  • In vivo dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer--a phantom study.

    abstract::A phantom study for dosimetry in the urethra using alanine/ESR during (192)Ir HDR brachytherapy of prostate cancer is presented. The measurement method of the secondary standard of the Physikalisch-Technische Bundesanstalt had to be slightly modified in order to be able to measure inside a Foley catheter. The absorbed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/022

    authors: Anton M,Wagner D,Selbach HJ,Hackel T,Hermann RM,Hess CF,Vorwerk H

    更新日期:2009-05-07 00:00:00

  • Preliminary evaluation of biomechanical modeling of lung deflation during minimally invasive surgery using pneumothorax computed tomography scans.

    abstract::During minimally invasive surgery (MIS) for lung tumor resection, the localization of tumors or nodules relies on visual inspection of the deflated lung on intra-procedural video. For patients with tumors or nodules located deeper in the lung, this localization is not possible without prior invasive marking techniques...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb6ba

    authors: Lesage AJ,Rajaram R,Tam AL,Rigaud BS,Brock KK,Rice DC,Cazoulat G

    更新日期:2020-09-09 00:00:00

  • Positron autoradiography for intravascular imaging: feasibility evaluation.

    abstract::Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/4/014

    authors: Shikhaliev PM,Xu T,Ducote JL,Easwaramoorthy B,Mukherjee J,Molloi S

    更新日期:2006-02-21 00:00:00

  • Improved accuracy of markerless motion tracking on bone suppression images: preliminary study for image-guided radiation therapy (IGRT).

    abstract::The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images obtained by the dual-energy subtraction technique. This study was performed to evaluate the usefulness of bone suppression image processing in image-guided radiation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/n209

    authors: Tanaka R,Sanada S,Sakuta K,Kawashima H

    更新日期:2015-05-21 00:00:00

  • Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

    abstract::Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5983

    authors: Ng JA,Booth J,Poulsen P,Kuncic Z,Keall PJ

    更新日期:2013-09-07 00:00:00

  • Investigation of the refractive index decrement of 3D printing materials for manufacturing breast phantoms for phase contrast imaging.

    abstract::3D breast modelling for 2D and 3D breast x-ray imaging would benefit from the availability of digital and physical phantoms that reproduce accurately the complexity of the breast anatomy. While a number of groups have produced digital phantoms with increasing level of complexity, physical phantoms reproducing that sof...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab0670

    authors: Esposito G,Mettivier G,Bliznakova K,Bliznakov Z,Bosmans H,Bravin A,Buliev I,Di Lillo F,Ivanov D,Minutillo M,Sarno A,Vignero J,Russo P

    更新日期:2019-03-27 00:00:00

  • Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

    abstract::Temporal regularization plays a critical role in cardiac gated dynamic SPECT reconstruction, of which the goal is to obtain an image sequence from a single acquisition which simultaneously shows both cardiac motion and tracer distribution change over the course of imaging (termed 5D). In our recent work, we explored t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/17/5523

    authors: Niu X,Yang Y,King MA

    更新日期:2012-09-07 00:00:00

  • Quantitative imaging of coronary flows using 3D ultrafast Doppler coronary angiography.

    abstract::Coronary flow rate remains complex to assess in clinical practice using non-invasive, non-ionizing imaging tools. In this study, we introduce 3D ultrafast Doppler coronary angiography (3D UDCA), an ultrasound-based method to assess coronary blood flows in three-dimensions at high volume-rate and in one single heartbea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8d78

    authors: Correia M,Maresca D,Goudot G,Villemain O,Bizé A,Sambin L,Tanter M,Ghaleh B,Pernot M

    更新日期:2020-06-05 00:00:00

  • 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry.

    abstract::When dosimetric effects in time-dependent geometries are studied, usually either the results of individual three-dimensional (3D) calculations are combined or probability-based approaches are applied. These methods may become cumbersome and time-consuming if high time resolution is required or if the geometry is compl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/5/020

    authors: Paganetti H,Jiang H,Trofimov A

    更新日期:2005-03-07 00:00:00

  • Correction factors for parallel-plate chambers used in plastic phantoms in electron dosimetry.

    abstract::In electron beam dosimetry using parallel-plate chambers solid phantoms are sometimes necessary. To obtain the dose to water from the ionization obtained in the solid phantom, fluence correction factors and perturbation factors have to be applied. In this study fluence factors in a perturbation free geometry have been...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/007

    authors: Nilsson B,Montelius A,Andreo P,Johansson J

    更新日期:1997-11-01 00:00:00

  • Spinal pedicle screw planning using deformable atlas registration.

    abstract::Spinal screw placement is a challenging task due to small bone corridors and high risk of neurological or vascular complications, benefiting from precision guidance/navigation and quality assurance (QA). Implicit to both guidance and QA is the definition of a surgical plan-i.e. the desired trajectories and device sele...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5f42

    authors: Goerres J,Uneri A,De Silva T,Ketcha M,Reaungamornrat S,Jacobson M,Vogt S,Kleinszig G,Osgood G,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-07 00:00:00

  • Derivation of mean dose tolerances for new fractionation schemes and treatment modalities.

    abstract::Avoiding toxicities in radiotherapy requires the knowledge of tolerable organ doses. For new, experimental fractionation schemes (e.g. hypofractionation) these are typically derived from traditional schedules using the biologically effective dose (BED) model. In this report we investigate the difficulties of establish...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9836

    authors: Perkó Z,Bortfeld T,Hong T,Wolfgang J,Unkelbach J

    更新日期:2018-02-05 00:00:00