Evaluation of multiple-sphere head models for MEG source localization.

Abstract:

:Magnetoencephalography (MEG) source analysis has largely relied on spherical conductor models of the head to simplify forward calculations of the brain's magnetic field. Multiple- (or overlapping, local) sphere models, where an optimal sphere is selected for each sensor, are considered an improvement over single-sphere models and are computationally simpler than realistic models. However, there is limited information available regarding the different methods used to generate these models and their relative accuracy. We describe a variety of single- and multiple-sphere fitting approaches, including a novel method that attempts to minimize the field error. An accurate boundary element method simulation was used to evaluate the relative field measurement error (12% on average) and dipole fit localization bias (3.5 mm) of each model over the entire brain. All spherical models can contribute in the order of 1 cm to the localization bias in regions of the head that depart significantly from a sphere (inferior frontal and temporal). These spherical approximation errors can give rise to larger localization differences when all modeling effects are taken into account and with more complex source configurations or other inverse techniques, as shown with a beamformer example. Results differed noticeably depending on the source location, making it difficult to recommend a fitting method that performs best in general. Given these limitations, it may be advisable to expand the use of realistic head models.

journal_name

Phys Med Biol

authors

Lalancette M,Quraan M,Cheyne D

doi

10.1088/0031-9155/56/17/010

subject

Has Abstract

pub_date

2011-09-07 00:00:00

pages

5621-35

issue

17

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)82010-5

journal_volume

56

pub_type

杂志文章
  • Detection of in situ mammary cancer in a transgenic mouse model: in vitro and in vivo MRI studies demonstrate histopathologic correlation.

    abstract::Improving the prevention and detection of preinvasive ductal carcinoma in situ (DCIS) is expected to lower both morbidity and mortality from breast cancer. Transgenic mouse models can be used as a 'test bed' to develop new imaging methods and to evaluate the efficacy of candidate preventive therapies. We hypothesized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/014

    authors: Jansen SA,Conzen SD,Fan X,Krausz T,Zamora M,Foxley S,River J,Newstead GM,Karczmar GS

    更新日期:2008-10-07 00:00:00

  • A control systems approach for the simulation of renal dynamic software phantoms for nuclear medicine.

    abstract::For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/008

    authors: Houston AS,Sampson WF,Jose RM,Boyce JF

    更新日期:1999-02-01 00:00:00

  • The use of a realistic VMAT delivery emulator to optimize dynamic machine parameters for improved treatment efficiency.

    abstract::The delivery of volumetric modulated arc therapy (VMAT) requires the simultaneous movement of the linear accelerator gantry, multi-leaf collimators and jaws while the dose rate is varied. In this study, a VMAT delivery emulator was developed to accurately predict the characteristics of a given treatment plan, incorpor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/024

    authors: Boylan CJ,Rowbottom CG,Mackay RI

    更新日期:2011-07-07 00:00:00

  • Estimating photon interaction coefficients from single energy x-ray CT.

    abstract::Single energy x-ray analysis is explored in the context of computed tomography (CT), whereby Hounsfield numbers (HN) are used to estimate electron density N(e) and parameters that describe composition. We examine measurements with tissue substitute materials and theoretical HN for a broad range of tissues. Results are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/8079

    authors: Midgley SM

    更新日期:2012-12-07 00:00:00

  • A promising new mechanism of ionizing radiation detection for positron emission tomography: modulation of optical properties.

    abstract::Using conventional scintillation detection, the fundamental limit in positron emission tomography (PET) time resolution is strongly dependent on the inherent temporal variances generated during the scintillation process, yielding an intrinsic physical limit for the coincidence time resolution of around 100 ps. On the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7600

    authors: Tao L,Daghighian HM,Levin CS

    更新日期:2016-11-07 00:00:00

  • Radiation damage, repopulation and cell recovery analysis of in vitro tumour cell megacolony culture data using a non-Poissonian cell repopulation TCP model.

    abstract::The effects of radiation damage, tumour repopulation and cell sublethal damage repair and the possibility of extracting information about the model parameters describing them are investigated in this work. Previously published data on two different cultured cell lines were analysed with the help of a tumour control pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/006

    authors: Stavrev P,Weldon M,Warkentin B,Stavreva N,Fallone BG

    更新日期:2005-07-07 00:00:00

  • Terahertz near-field imaging.

    abstract::A near-field probe is described that enables high spatial resolution imaging with terahertz (THz) pulses. The spatial resolution capabilities of the system lie in the range of few microns and we demonstrate a resolution of 7 microm using broad-banded THz pulses with an intensity maximum near 0.5 THz. We present a stud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/308

    authors: Federici JF,Mitrofanov O,Lee M,Hsu JW,Brener I,Harel R,Wynn JD,Pfeiffer LN,West KW

    更新日期:2002-11-07 00:00:00

  • Robust radiation therapy optimization using simulated treatment courses for handling deformable organ motion.

    abstract::We describe a radiation therapy treatment plan optimization method that explicitly considers the effects of interfraction organ motion through optimization on the clinical target volume (CTV), and investigate how it compares to conventional planning using a planning target volume (PTV). The method uses simulated treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abd591

    authors: Fredriksson A,Engwall E,Andersson B

    更新日期:2020-12-21 00:00:00

  • [A simulation method for studying scintillation camera collimators].

    abstract::This paper presents a computer simulation of photon interaction with collimator septa, which allows the point spread function of scintillation camera collimators to be calculated. The method simulates photon attenuation along their propagation direction in a determinist way. Using this simulation, the spatial resoluti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/5/006

    authors: Gantet P,Esquerré JP,Danet B,Guiraud R

    更新日期:1990-05-01 00:00:00

  • Pulsed focused ultrasound lowers interstitial fluid pressure and increases nanoparticle delivery and penetration in head and neck squamous cell carcinoma xenograft tumors.

    abstract::Nanocarriers offer a promising approach to significantly improve therapeutic delivery to solid tumors as well as limit the side effects associated with anti-cancer agents. However, their relatively large size can negatively affect their ability to efficiently penetrate into more interior tumor regions, ultimately redu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9705

    authors: Mohammadabadi A,Huynh RN,Wadajkar AS,Lapidus RG,Kim AJ,Raub CB,Frenkel V

    更新日期:2020-06-22 00:00:00

  • Direct detection of 6 MV x-rays from a medical linear accelerator using a semiconducting polymer diode.

    abstract::Recently, a new family of low-cost x-radiation detectors have been developed, based on semiconducting polymer diodes, which are easy to process, mechanically flexible, relatively inexpensive, and able to cover large areas. To test their potential for radiotherapy applications such as beam monitors or dosimeters, as an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4471

    authors: Mills CA,Chan YF,Intaniwet A,Shkunov M,Nisbet A,Keddie JL,Sellin PJ

    更新日期:2013-07-07 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • Characteristics of boron-dose enhancer dependent on dose protocol and 10B concentration for BNCT using near-threshold 7Li(p,n)7Be direct neutrons.

    abstract::The dependence of boron-dose enhancer (BDE) characteristics on dose protocol and 10B concentration was evaluated for BNCT using near-threshold 7Li(p,n)7Be direct neutrons. The treatable protocol depth (TPD) was utilized as an evaluation index. MCNP calculations were performed for near-threshold 7Li(p,n)7Be at a proton...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/1/013

    authors: Tanaka K,Kobayashi T,Bengua G,Nakagawa Y,Endo S,Hoshi M

    更新日期:2005-01-07 00:00:00

  • A point kernel algorithm for microbeam radiation therapy.

    abstract::Microbeam radiation therapy (MRT) is a treatment approach in radiation therapy where the treatment field is spatially fractionated into arrays of a few tens of micrometre wide planar beams of unusually high peak doses separated by low dose regions of several hundred micrometre width. In preclinical studies, this treat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8d63

    authors: Debus C,Oelfke U,Bartzsch S

    更新日期:2017-10-19 00:00:00

  • Dose distribution to spinal structures from intrathecally administered yttrium-90.

    abstract::Previous treatment of cerebrospinal fluid (CSF) malignancies by intrathecal administration of (131)I-radiolabelled monoclonal antibodies has led to the assumption that more healthy tissue will be spared when a pure beta-emitter such as (90)Y replaces (131)I. The purpose of this study is to compare and quantitatively e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/1/014

    authors: Mardirossian G,Hall M,Montebello J,Stevens P

    更新日期:2006-01-07 00:00:00

  • A thin target approach for portal imaging in medical accelerators.

    abstract::A new thin-target method (patent pending) is described for portal imaging with low-energy (tens of keV) photons from a medical linear accelerator operating in a special mode. Low-energy photons are usually produced in the accelerator target, but are absorbed by the target and flattening filter, both made of medium- or...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/016

    authors: Tsechanski A,Bielajew AF,Faermann S,Krutman Y

    更新日期:1998-08-01 00:00:00

  • Improved dose-calculation accuracy in proton treatment planning using a simplified Monte Carlo method verified with three-dimensional measurements in an anthropomorphic phantom.

    abstract::Treatment planning for proton tumor therapy requires a fast and accurate dose-calculation method. We have implemented a simplified Monte Carlo (SMC) method in the treatment planning system of the National Cancer Center Hospital East for the double-scattering beam delivery scheme. The SMC method takes into account the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/018

    authors: Hotta K,Kohno R,Takada Y,Hara Y,Tansho R,Himukai T,Kameoka S,Matsuura T,Nishio T,Ogino T

    更新日期:2010-06-21 00:00:00

  • Automatic extraction of pectoral muscle in the MLO view of mammograms.

    abstract::A mammogram is the standard modality used for breast cancer screening. Computer-aided detection (CAD) approaches are helpful for improving breast cancer detection rates when applied to mammograms. However, automated analysis of a mammogram often leads to inaccurate results in the presence of the pectoral muscle. There...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/23/8493

    authors: Feudjio CK,Klein J,Tiedeu A,Colot O

    更新日期:2013-12-07 00:00:00

  • Normalized glandular dose (DgN) coefficients from experimental mammographic x-ray spectra.

    abstract::Mean glandular dose is the quantity used for dosimetry in mammography and depends on breast-related characteristics, such as thickness and density, and on the x-ray spectrum used for breast imaging. This work aims to present an experimentally-based method to derive polyenergetic normalized glandular dose coefficients ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab171a

    authors: Santos JC,Tomal A,de Barros N,Costa PR

    更新日期:2019-05-10 00:00:00

  • Radionuclides and carrier molecules for therapy.

    abstract::Although radionuclide therapy has been around for a long time, this modality of cancer treatment has been limited mainly to the use of [32P]-phosphate and [131I]-sodium iodide. The last few years, however, have seen an increased interest in this area due to new developments of radionuclides and carrier molecules that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/41/10/004

    authors: Zweit J

    更新日期:1996-10-01 00:00:00

  • Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

    abstract::Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurement...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/1/002

    authors: Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

    更新日期:2004-01-07 00:00:00

  • A novel linear programming approach to fluence map optimization for intensity modulated radiation therapy treatment planning.

    abstract::We present a novel linear programming (LP) based approach for efficiently solving the intensity modulated radiation therapy (IMRT) fluence-map optimization (FMO) problem to global optimality. Our model overcomes the apparent limitations of a linear-programming approach by approximating any convex objective function by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/21/005

    authors: Romeijn HE,Ahuja RK,Dempsey JF,Kumar A,Li JG

    更新日期:2003-11-07 00:00:00

  • A limited-angle CT reconstruction method based on anisotropic TV minimization.

    abstract::This paper presents a compressed sensing (CS)-inspired reconstruction method for limited-angle computed tomography (CT). Currently, CS-inspired CT reconstructions are often performed by minimizing the total variation (TV) of a CT image subject to data consistency. A key to obtaining high image quality is to optimize t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/7/2119

    authors: Chen Z,Jin X,Li L,Wang G

    更新日期:2013-04-07 00:00:00

  • List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

    abstract::Respiratory motion in emission tomography leads to reduced image quality. Developed correction methodology has been concentrating on the use of respiratory synchronized acquisitions leading to gated frames. Such frames, however, are of low signal-to-noise ratio as a result of containing reduced statistics. In this wor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/17/006

    authors: Lamare F,Ledesma Carbayo MJ,Cresson T,Kontaxakis G,Santos A,Le Rest CC,Reader AJ,Visvikis D

    更新日期:2007-09-07 00:00:00

  • Simulation of small-angle x-ray scattering from collagen fibrils and comparison with experimental patterns.

    abstract::Simulation of small-angle x-ray scattering from collagen in healthy and cancerous breast tissue may reveal detailed information on the structural changes in collagen. Collagen fibril is modelled as a cylinder with axially periodic step-function electron density, and packing is approximated by placing the cylinders in ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/012

    authors: Suhonen H,Fernández M,Serimaa R,Suortti P

    更新日期:2005-11-21 00:00:00

  • Depth of ionization chamber in water.

    abstract::The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/8/007

    authors: Tailor RC,Tello VM

    更新日期:1995-08-01 00:00:00

  • An algorithm to include the bremsstrahlung contamination in the determination of the absorbed dose in electron beams.

    abstract::None of the existing protocols or codes of practice for high-energy electron dosimetry take any account of the accelerator-generated bremsstrahlung always present in electron beams. This results in a systematic error in the derivation of the absorbed dose. The purpose of this study is to draw attention to this omissio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/7/004

    authors: Klevenhagen SC

    更新日期:1994-07-01 00:00:00

  • Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography.

    abstract::The objective of this study was to be able to distinguish between healthy skin tissue and malignant ones, furthermore determining a unique pattern of roughness for each skin lesion by microtopographic analysis of the skin surface of Mexican patients during the period from April to October 2002. The standard technique ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/008

    authors: del Carmen López Pacheco M,da Cunha Martins-Costa MF,Zapata AJ,Cherit JD,Gallegos ER

    更新日期:2005-12-07 00:00:00

  • Cross-sections for the inactivation of ribonuclease by slow heavy ions.

    abstract::Average cross-sections for inactivation of dry ribonuclease by H, He and N projectiles with energies between 100 eV and 10 keV are presented. The trend of the damage cross-sections with particle energy is consistent with the trend of the molecular quasi-elastic scattering and ionization cross-sections. A tentative rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/6/005

    authors: Watt DE,Sutcliffe JF

    更新日期:1975-11-01 00:00:00

  • Using mathematical morphology to determine left ventricular contours.

    abstract::The aim of this study is to investigate the use of mathematical morphology for the determination of left ventricular contours in scintigraphic images using multigated radionuclide angiography. We have developed a completely automatic method that first restores the image with a Wiener filter, then finds the region wher...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/12/012

    authors: Pladellorens J,Serrat J,Castell A,Yzuel MJ

    更新日期:1993-12-01 00:00:00