Comparison between TG-51 and TRS-398: electron contamination effect on photon beam-quality specification.

Abstract:

:Two dosimetry protocols based on absorbed dose to water have recently been implemented: TG-51 and TRS-398. These protocols use different beam-quality indices: %dd(10)x and TPR20,10. The effect of electron contamination in measurements of %dd(10)x has been proposed as a disadvantage of the TG-51. For actual measurements of %dd(10)x in five clinical beams (Primus 6-18 MV, SL-75/5 6 MV, SL-18 6-15 MV) a purging magnet was employed to remove the electron contamination. Also, %dd(10)x was measured in the different ways described in TG-51 for high-energy beams: with a lead foil at 50 cm from the phantom surface, at 30 cm, and for open beam. Moreover, TPR20,10 was determined. Also, periodic quality-control measurements were used for comparing both quality indices and variation over time, but D20,10 was used instead of TPR20,10 and measurements in open beam for the %dd(10)x determination. Considering both protocols, S(w,air) and kQ were calculated in order to compare the results with the experimental data. Significant differences (0.3% for kQ) were only found for the two high-energy beams, but when the electron contamination is underestimated by TG-51, the difference in kQ is lower. Differences in the other cases and variations over time were less than 0.1%.

journal_name

Phys Med Biol

authors

Lopez Medina A,Teijeiro A,Salvador F,Medal D,Vazquez J,Salgado M,Carrion MC

doi

10.1088/0031-9155/49/1/002

subject

Has Abstract

pub_date

2004-01-07 00:00:00

pages

17-32

issue

1

eissn

0031-9155

issn

1361-6560

journal_volume

49

pub_type

杂志文章
  • Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy.

    abstract::In this note a technique is described for direct aperture optimization of components deliverable by a variable aperture collimator (VAC) for intensity-modulated radiation therapy. The first key result found was that, provided a large number of VAC components were selected for optimization, the resulting fluence profil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/n02

    authors: Webb S

    更新日期:2004-03-07 00:00:00

  • Proton beam monitor chamber calibration.

    abstract::The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic prot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/17/4961

    authors: Gomà C,Lorentini S,Meer D,Safai S

    更新日期:2014-09-07 00:00:00

  • Optimization of the artificial urinary sphincter: modelling and experimental validation.

    abstract::The artificial urinary sphincter should be long enough to prevent strangulation effects of the urethral tissue and short enough to avoid the improper dissection of the surrounding tissue. To optimize the sphincter length, the empirical three-parameter urethra compression model is proposed based on the mechanical prope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/023

    authors: Marti F,Leippold T,John H,Blunschi N,Müller B

    更新日期:2006-03-07 00:00:00

  • Spectral phase-based automatic calibration scheme for swept source-based optical coherence tomography systems.

    abstract::The automatic calibration in Fourier-domain optical coherence tomography (FD-OCT) systems allows for high resolution imaging with precise depth ranging functionality in many complex imaging scenarios, such as microsurgery. However, the accuracy and speed of the existing automatic schemes are limited due to the functio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7652

    authors: Ratheesh KM,Seah LK,Murukeshan VM

    更新日期:2016-11-07 00:00:00

  • 3D prompt gamma imaging for proton beam range verification.

    abstract::We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC place...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa203

    authors: Draeger E,Mackin D,Peterson S,Chen H,Avery S,Beddar S,Polf JC

    更新日期:2018-01-30 00:00:00

  • A theoretical approach for non-equilibrium radiation dosimetry.

    abstract::This study presents a theoretical approach to the dosimetry for small and non-equilibrium radiation fields. We applied the newly developed VMCBC algorithm to the dosimetry for megavoltage photon beams using Monte Carlo techniques. The approach assumes that a Monte Carlo simulated beam can be calibrated per incident pa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/006

    authors: Ding GX,Duggan DM,Coffey CW

    更新日期:2008-07-07 00:00:00

  • Modelling individual temperature profiles from an isolated perfused bovine tongue.

    abstract::To predict the temperature distribution during hyperthermia treatments a thermal model that accounts for the thermal effect of blood flow is mandatory. The DIscrete VAsculature (DIVA) thermal model developed at our department is able to do so; geometrically described vessels are handled individually and the remaining ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/3/314

    authors: Raaymakers BW,Crezee J,Lagendijk JJ

    更新日期:2000-03-01 00:00:00

  • Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    abstract::The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excise...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/001

    authors: Stupic KF,Elkins ND,Pavlovskaya GE,Repine JE,Meersmann T

    更新日期:2011-07-07 00:00:00

  • Dynamics of the upper urinary tract: I. Peristaltic flow through a distensible tube of limited length.

    abstract::A theoretical analysis and numerical solutions are presented for viscosity-dominated flow through a uniform, highly distensible tube with a slit-shaped cross section undergoing peristalsis. At flow rates below an intrinsic upper limit to the peristaltic carrying capacity of the tube, provided that there is always at l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/7/002

    authors: Griffiths DJ

    更新日期:1987-07-01 00:00:00

  • Ionization quenching in scintillators used for dosimetry of mixed particle fields.

    abstract::Ionization quenching in ion beam dosimetry is often related to the fluence- or dose-averaged linear energy transfer (LET). Both quantities are however averaged over a wide LET range and a mixed field of primary and secondary ions. We propose a novel method to correct the quenched luminescence in scintillators exposed ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab12f2

    authors: Christensen JB,Almhagen E,Stolarczyk L,Vestergaard A,Bassler N,Andersen CE

    更新日期:2019-04-29 00:00:00

  • Measurement of the dielectric properties of the epidermis and dermis at frequencies from 0.5 GHz to 110 GHz.

    abstract::Numerous studies have reported the measurements of the dielectric properties of the skin. Clarifying the manner in which the human body interacts with electromagnetic waves is essential for medical research and development, as well as for the safety assessment of electromagnetic wave exposure. The skin comprises sever...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/16/4739

    authors: Sasaki K,Wake K,Watanabe S

    更新日期:2014-08-21 00:00:00

  • Physics of contrast mechanism and averaging effect of linear attenuation coefficients in a computerized transverse axial tomography CTAT) transmission scanner.

    abstract::Detailed studies of the basic contrast mechanisms in computerized transverse axial tomography scanners have been carried out. Contrast is related to the effective atomic numbers and electron densities of materials and the resultant linear attenuation coefficients. We have therefore quantitatively evaluated various sam...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/4/006

    authors: Tsai CM,Cho ZH

    更新日期:1976-07-01 00:00:00

  • The energy response of a T.P.A. Mk-II ionization chamber using GEANT4 Monte Carlo simulation.

    abstract::The low energy model of the GEANT4 Monte Carlo toolkit was used to simulate the energy response of a T.P.A. Mk-II ionization chamber under a variety of different conditions. The sample position resulting in the maximum response along the axial direction of the chamber was obtained. The parameters of the simulation wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/012

    authors: Seneviratne MD,Reinhard MI,Baldock C

    更新日期:2007-07-07 00:00:00

  • Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study.

    abstract::The purpose of this work was to characterize expert variation in segmentation of intracranial structures pertinent to radiation therapy, and to assess a registration-driven atlas-based segmentation algorithm in that context. Eight experts were recruited to segment the brainstem, optic chiasm, optic nerves, and eyes, o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/021

    authors: Deeley MA,Chen A,Datteri R,Noble JH,Cmelak AJ,Donnelly EF,Malcolm AW,Moretti L,Jaboin J,Niermann K,Yang ES,Yu DS,Yei F,Koyama T,Ding GX,Dawant BM

    更新日期:2011-07-21 00:00:00

  • A 4D biomechanical lung phantom for joint segmentation/registration evaluation.

    abstract::At present, there exists few openly available methods for evaluation of simultaneous segmentation and registration algorithms. These methods allow for a combination of both techniques to track the tumor in complex settings such as adaptive radiotherapy. We have produced a quality assurance platform for evaluating this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/19/7012

    authors: Markel D,Levesque I,Larkin J,Léger P,El Naqa I

    更新日期:2016-10-07 00:00:00

  • Arranging optical fibres for the spatial resolution improvement of topographical images.

    abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/18/311

    authors: Yamamoto T,Maki A,Kadoya T,Tanikawa Y,Yamad Y,Okada E,Koizumi H

    更新日期:2002-09-21 00:00:00

  • Examination of errors caused by random summing in in vivo prompt gamma ray analysis.

    abstract::A technique is described for examining the mode of operation of radiation detectors and estimating the losses and gains caused by random summing effects in spectra acquired at high counting rates. The technique is applied to estimating the errors caused by random summing when measuring the amounts of carbon and nitrog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/8/010

    authors: Yankuba S,Oldroyd B,Metcalfe SC,Godfrey JE,Oxby CB

    更新日期:1989-08-01 00:00:00

  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • Energy response of optically stimulated luminescent dosimeters for non-reference measurement locations in a 6 MV photon beam.

    abstract::Optically stimulated luminescent dosimeters (OSLDs) are becoming increasingly popular for measuring an absorbed dose in clinical radiotherapy. OSLDs have known energy dependence, and this is accounted for by either calibrating the OSLD with a specific nominal energy, or using a standard energy correction factor to acc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2505

    authors: Scarboro SB,Followill DS,Kerns JR,White RA,Kry SF

    更新日期:2012-05-07 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    abstract::X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the imag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/009

    authors: Brunner S,Nett BE,Tolakanahalli R,Chen GH

    更新日期:2011-02-21 00:00:00

  • Analytical calculation of the portal scatter to primary dose ratio: an EGS4 Monte Carlo and experimental validation at large air gaps.

    abstract::An analytical approximation for the scatter to primary dose ratio (SPR) on the central axis was validated against Monte Carlo results and experimental measurements for homogeneous and inhomogeneous phantoms. The analytical approximation only included first-order Compton scatter. The contribution to the total SPR from ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/6/310

    authors: Ozard SR,Grein EE

    更新日期:2001-06-01 00:00:00

  • Design and performance of the micro-dose calibrator.

    abstract::A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT) module prototype built to evaluate its performance. The design of the micro-dose calibrator is based on the con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadb3b

    authors: Adler S,Choyke P

    更新日期:2018-09-10 00:00:00

  • Comparison of Geant4 multiple Coulomb scattering models with theory for radiotherapy protons.

    abstract::Usually, Monte Carlo models are validated against experimental data. However, models of multiple Coulomb scattering (MCS) in the Gaussian approximation are exceptional in that we have theories which are probably more accurate than the experiments which have, so far, been done to test them. In problems directly sensiti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6ce3

    authors: Makarova A,Gottschalk B,Sauerwein W

    更新日期:2017-07-06 00:00:00

  • 4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

    abstract::A 4D ordered-subsets maximum a posteriori (OSMAP) algorithm for dynamic SPECT is described which uses a temporal prior that constrains each voxel's behaviour in time to conform to a compartmental model. No a priori limitations on kinetic parameters are applied; rather, the parameter estimates evolve as the algorithm i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/5/315

    authors: Kadrmas DJ,Gullberg GT

    更新日期:2001-05-01 00:00:00

  • Measurement and simulation of unmyelinated nerve electrostimulation: Lumbricus terrestris experiment and numerical model.

    abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4364

    authors: Šarolić A,Živković Z,Reilly JP

    更新日期:2016-06-21 00:00:00

  • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.

    abstract::Multileaf collimator (MLC) calibration and quality control is a time-consuming procedure typically involving the processing, scanning and analysis of films to measure leaf and collimator positions. Faster and more reliable calibration procedures are required for these tasks, especially with the introduction of intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/7/003

    authors: Baker SJ,Budgell GJ,MacKay RI

    更新日期:2005-04-07 00:00:00

  • Effect of errors in the system matrix on maximum a posteriori image reconstruction.

    abstract::Statistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/14/007

    authors: Qi J,Huesman RH

    更新日期:2005-07-21 00:00:00

  • An investigation into the vector ellipticity of extremely low frequency magnetic fields from appliances in UK homes.

    abstract::Elliptically polarized magnetic fields induce higher currents in the body compared with their plane polarized counterparts. This investigation examines the degree of vector ellipticity of extremely low frequency magnetic fields (ELF-MFs) in the home, with regard to the adverse health effects reportedly associated with...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/13/016

    authors: Ainsbury EA,Conein E,Henshaw DL

    更新日期:2005-07-07 00:00:00

  • Large-angle x-ray scatter in Talbot-Lau interferometry for breast imaging.

    abstract::Monte Carlo simulations were used to investigate large-angle x-ray scatter at design energy of 25 keV during small field of view (9.6 cm × 5 cm) differential phase contrast imaging of the breast using Talbot-Lau interferometry. Homogenous, adipose and fibroglandular breasts of uniform thickness ranging from 2 to 8 cm ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/21/6387

    authors: Vedantham S,Shi L,Karellas A

    更新日期:2014-11-07 00:00:00