Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Abstract:

:Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter modeling can be applied to non-parallel-beam projection geometries.

journal_name

Phys Med Biol

authors

Du Y,Bhattacharya M,Frey EC

doi

10.1088/0031-9155/59/11/2813

subject

Has Abstract

pub_date

2014-06-07 00:00:00

pages

2813-28

issue

11

eissn

0031-9155

issn

1361-6560

journal_volume

59

pub_type

杂志文章
  • Assessment of organ-specific neutron equivalent doses in proton therapy using computational whole-body age-dependent voxel phantoms.

    abstract::Proton beams used for radiotherapy will produce neutrons when interacting with matter. The purpose of this study was to quantify the equivalent dose to tissue due to secondary neutrons in pediatric and adult patients treated by proton therapy for brain lesions. Assessment of the equivalent dose to organs away from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/3/012

    authors: Zacharatou Jarlskog C,Lee C,Bolch WE,Xu XG,Paganetti H

    更新日期:2008-02-07 00:00:00

  • A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.

    abstract::A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/005

    authors: Pradhan AS,Quast U,Sharma PK

    更新日期:1994-09-01 00:00:00

  • Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications.

    abstract::The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/5/005

    authors: Zoetelief J,Broerse JJ

    更新日期:1983-05-01 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • Quantitative analysis of synchrotron radiation intravenous angiographic images.

    abstract::A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-st...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/50/4/011

    authors: Sarnelli A,Nemoz C,Elleaume H,Estève F,Bertrand B,Bravin A

    更新日期:2005-02-21 00:00:00

  • Soft-tissue phase-contrast tomography with an x-ray tube source.

    abstract::We report the first experimental soft-tissue phase-contrast tomography results using a conventional x-ray tube source, with a millimeter-sized focal spot. The setup is based on a Talbot-Lau grating interferometer operated at a mean energy of 28 keV. We present three-dimensional ex vivo images of a chicken heart sample...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/9/010

    authors: Bech M,Jensen TH,Feidenhans'l R,Bunk O,David C,Pfeiffer F

    更新日期:2009-05-07 00:00:00

  • Relative electron density determination using a physics based parameterization of photon interactions in medical DECT.

    abstract::Radiotherapy and particle therapy treatment planning require accurate knowledge of the electron density and elemental composition of the tissues in the beam path to predict the local dose deposition. We describe a method for the analysis of dual energy computed tomography (DECT) images that provides the electron densi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/9/3825

    authors: van Abbema JK,van Goethem MJ,Greuter MJ,van der Schaaf A,Brandenburg S,van der Graaf ER

    更新日期:2015-05-07 00:00:00

  • Laser shaping of corneal transplants in vitro: area ablation with small overlapping laser spots produced by a pulsed scanning laser beam using an optimizing ablation algorithm.

    abstract::Area laser lathing and trephination of donor corneas is used to produce different types of grafts for human transplantation. 193 nm (ArF excimer) laser radiation is used, since this is known to give a non-thermal laser-tissue interaction with a minimal zone of tissue damage. To guarantee the highest degree of flexibil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/5/005

    authors: Homolka P,Biowski R,Kaminski S,Barisani T,Husinsky W,Bergmann H,Grabner G

    更新日期:1999-05-01 00:00:00

  • Modeling localized delivery of Doxorubicin to the brain following focused ultrasound enhanced blood-brain barrier permeability.

    abstract::Doxorubicin (Dox) is a well-established chemotherapeutic agent, however it has limited efficacy in treating brain malignancies due to the presence of the blood-brain barrier (BBB). Recent preclinical studies have demonstrated that focused ultrasound induced BBB disruption (BBBD) enables efficient delivery of Dox to th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/5987

    authors: Nhan T,Burgess A,Lilge L,Hynynen K

    更新日期:2014-10-21 00:00:00

  • The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

    abstract::Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/24/010

    authors: Pukala J,Meeks SL,Bova FJ,Langen KM

    更新日期:2011-12-21 00:00:00

  • Single-shot K-edge subtraction x-ray discrete computed tomography with a polychromatic source and the Pixie-III detector.

    abstract::K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7105

    authors: Brun F,Di Trapani V,Albers J,Sacco P,Dreossi D,Brombal L,Rigon L,Longo R,Mittone A,Dullin C,Bravin A,Delogu P

    更新日期:2020-03-06 00:00:00

  • Experimental verification of a model for predicting transient temperature distributions by focused ultrasound.

    abstract::A thermal model for predicting time-dependent temperature distributions during ultrasound heating was tested quantitatively. The relevant thermal processes incorporated in the model are heat conduction and ultrasound power absorption, and the required input parameters include the absolute ultrasound power, the shape a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/9/001

    authors: Chin RB,Zagzebski JA,Madsen EL

    更新日期:1991-09-01 00:00:00

  • Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles.

    abstract::The objective of this work is to test analytical models to calculate the luminescence efficiency of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to heavy charged particles with energies relevant to space dosimetry and particle therapy. We used the track structure model to obtain an analytica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/437

    authors: Sawakuchi GO,Yukihara EG

    更新日期:2012-01-21 00:00:00

  • Automated 3D ultrasound image analysis for first trimester assessment of fetal health.

    abstract::The first trimester fetal ultrasound scan is important to confirm fetal viability, to estimate the gestational age of the fetus, and to detect fetal anomalies early in pregnancy. First trimester ultrasound images have a different appearance than for the second trimester scan, reflecting the different stage of fetal de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3ad1

    authors: Ryou H,Yaqub M,Cavallaro A,Papageorghiou AT,Alison Noble J

    更新日期:2019-09-17 00:00:00

  • The feasibility of using a liquid-filled Cerenkov counter of gamma-ray counting of large samples.

    abstract::The feasibility of detecting gamma rays with energies below 1.5 MeV by means of a large-volume liquid-filled Cerenkov counter has been examined, together with the characteristics and limitations of an experimental counter. Various liquids (water, glycerol, sodium iodide solution; and glycerol plus a wavelength shifter...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/23/3/007

    authors: Hesp R

    更新日期:1978-05-01 00:00:00

  • A multiplicative correction factor for tissue heterogeneities.

    abstract::A new multiplicative correction factor for tissue heterogeneities based on an exact expression for homogeneous non-unit-density media is proposed. O'Connor's density scaling theorem is invoked to evaluate the medium-specific tissue-maximum ratios used in the exact formulation. Monte Carlo calculations were performed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/10/005

    authors: Petti PL,Siddon RL,Bjärngard BE

    更新日期:1986-10-01 00:00:00

  • Evaluation of nonuniform field exposures with coupling factors.

    abstract::In this study, the safety compliance for nonuniform field exposures is discussed using coupling factor concepts. The coupling factor, which is defined in the International Electrotechnical Commission 62311 standard, is extended to consider the effects of harmonics and also to apply to the specific absorption rate (for...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/8129

    authors: Sunohara T,Hirata A,Laakso I,De Santis V,Onishi T

    更新日期:2015-10-21 00:00:00

  • The GSF family of voxel phantoms.

    abstract::Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/47/1/307

    authors: Petoussi-Henss N,Zanki M,Fill U,Regulla D

    更新日期:2002-01-07 00:00:00

  • Normalized glandular dose (DgN) coefficients from experimental mammographic x-ray spectra.

    abstract::Mean glandular dose is the quantity used for dosimetry in mammography and depends on breast-related characteristics, such as thickness and density, and on the x-ray spectrum used for breast imaging. This work aims to present an experimentally-based method to derive polyenergetic normalized glandular dose coefficients ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab171a

    authors: Santos JC,Tomal A,de Barros N,Costa PR

    更新日期:2019-05-10 00:00:00

  • A new method to reconstruct intra-fractional prostate motion in volumetric modulated arc therapy.

    abstract::Intra-fractional motion is a concern during prostate radiation therapy, as it may cause deviations between planned and delivered radiation doses. Because accurate motion information during treatment delivery is critical to address dose deviation, we developed the projection marker matching method (PM3), a novel method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e37

    authors: Chi Y,Rezaeian NH,Shen C,Zhou Y,Lu W,Yang M,Hannan R,Jia X

    更新日期:2017-07-07 00:00:00

  • Kinetic parameter estimation from SPECT cone-beam projection measurements.

    abstract::Kinetic parameters are commonly estimated from dynamically acquired nuclear medicine data by first reconstructing a dynamic sequence of images and subsequently fitting the parameters to time-activity curves generated from regions of interest overlaid upon the image sequence. Biased estimates can result from images rec...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/4/024

    authors: Huesman RH,Reutter BW,Zeng GL,Gullberg GT

    更新日期:1998-04-01 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00

  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • A temperature-based feedback control system for electromagnetic phased-array hyperthermia: theory and simulation.

    abstract::A hybrid proportional-integral-in-time and cost-minimizing-in-space feedback control system for electromagnetic, deep regional hyperthermia is proposed. The unique features of this controller are that (1) it uses temperature, not specific absorption rate, as the criterion for selecting the relative phases and amplitud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/5/306

    authors: Kowalski ME,Jin JM

    更新日期:2003-03-07 00:00:00

  • Dielectric characteristics of packed human erythrocytes with haemoglobins F, AA, AS and SS.

    abstract::The radiofrequency dielectric behaviour of packed human erythrocytes has been investigated in normal haemoglobins F and AA and also abnormal haemoglobins homozygous SS and heterozygous AS. Dielectric measurements were made in tightly packed blood cells at an average room temperature of 26.5 +/- 0.5 degrees C in the fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/4/002

    authors: Laogun AA,Ajayi NO,Okafor LO,Osamo NO

    更新日期:1983-04-01 00:00:00

  • Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

    abstract::Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:

    authors: Marshall NW,Kotre CJ

    更新日期:2002-03-21 00:00:00

  • Dielectric properties of porcine glands, gonads and body fluids.

    abstract::Dielectric properties of porcine glandular tissues and gonads (in vivo) and body fluids (in vitro) have been obtained in the frequency range of 50 MHz to 20 GHz. The experimental data were fitted to a two term Cole-Cole expression. The data presented complement the available dielectric properties of tissues in the lit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/N339

    authors: Peyman A,Gabriel C

    更新日期:2012-10-07 00:00:00

  • Treatment plan modification using voxel-based weighting factors/dose prescription.

    abstract::Under various clinical situations, it is desirable to modify the original treatment plan to better suit the clinical goals. In this work, a method to help physicians modify treatment plans based on their clinical preferences is proposed. The method uses a weighted quadratic dose objective function. The commonly used o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/15/315

    authors: Wu C,Olivera GH,Jeraj R,Keller H,Mackie TR

    更新日期:2003-08-07 00:00:00

  • Modelling the electrical properties of tissue as a porous medium.

    abstract::Models of the electrical properties of biological tissue have been the subject of many studies. These models have sought to explain aspects of the dielectric dispersion of tissue. This paper develops a mathematical model of the complex permittivity of tissue as a function of frequency f, in the range 10(4) < f < 10(7)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/23/016

    authors: Smye SW,Evans CJ,Robinson MP,Sleeman BD

    更新日期:2007-12-07 00:00:00