The effect of temporal HU variations on the uncertainty of dose recalculations performed on MVCT images.

Abstract:

:Over the course of radiation therapy, a patient's anatomy may change substantially. The relatively recent addition of frequent in-room imaging to assist with patient localization has provided a database of images that may be used to recalculate dose distributions for adaptive radiotherapy purposes. The TomoTherapy Hi-Art II unit (Accuray Inc., Sunnyvale, CA, USA) uses a helical scanning geometry and a megavoltage (MV) beam to acquire volumetric patient images. This study evaluated the uncertainty of dose calculations performed on megavoltage CT (MVCT) images as a function of temporal Hounsfield Unit (HU) variations observed in the imaging system over three years on two machines. A baseline error between dose calculations performed on kVCT and MVCT images was established using a series of phantoms. This baseline error ranged from -1.4% to 0.6%. Materials of differing densities were imaged and MVCT numbers were measured periodically. The MVCT number of solid water varied from 5 to 103 HU and consistently increased prior to target replacement. Finally, the dosimetric uncertainty of the temporal HU variation was assessed using MVCT images of typical head and neck, lung and prostate cancer patients. Worst-case MVCT recalculation errors could approach 5%, 7% and 10% for the head and neck, lung and prostate images, respectively. However, if a tolerance of ±30 HU were maintained for the MVCT number of solid water, dosimetric errors were limited to ±2.5%, ±3% and ±4%, respectively.

journal_name

Phys Med Biol

authors

Pukala J,Meeks SL,Bova FJ,Langen KM

doi

10.1088/0031-9155/56/24/010

subject

Has Abstract

pub_date

2011-12-21 00:00:00

pages

7829-41

issue

24

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(11)05865-9

journal_volume

56

pub_type

杂志文章
  • 3D prompt gamma imaging for proton beam range verification.

    abstract::We tested the ability of a single Compton camera (CC) to produce 3-dimensional (3D) images of prompt gammas (PGs) emitted during the irradiation of a tissue-equivalent plastic phantom with proton pencil beams for clinical doses delivered at clinical dose rates. PG measurements were made with a small prototype CC place...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa203

    authors: Draeger E,Mackin D,Peterson S,Chen H,Avery S,Beddar S,Polf JC

    更新日期:2018-01-30 00:00:00

  • Gating characteristics of an Elekta radiotherapy treatment unit measured with three types of detector.

    abstract::The characteristics of an Elekta Precise treatment machine with a gating interface were investigated. Three detectors were used: a Farmer ionization chamber, a MatriXX ionization chamber array and an in-house, single pulse-measurement ionization chamber (IVC). Measurements were made of dosimetric accuracy, flatness an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/N02

    authors: Evans PM,Symonds-Tayler JR,Colgan R,Hugo GD,Letts N,Sandin C

    更新日期:2010-04-21 00:00:00

  • Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis.

    abstract::Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/003

    authors: Monnin P,Marshall NW,Bosmans H,Bochud FO,Verdun FR

    更新日期:2011-07-21 00:00:00

  • Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method.

    abstract::Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories throu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/4/013

    authors: Bodammer NC,Kaufmann J,Kanowski M,Tempelmann C

    更新日期:2009-02-21 00:00:00

  • Measurement of total body nitrogen and oxygen by irradiation with cyclotron neutrons and 'delayed' gamma ray counting.

    abstract::Measurement of total body nitrogen is assuming increasing importance in the nutritional evaluation of seriously ill patients. Nitrogen has been previously measured either by counting (i) the annihilation radiation from 13N immediately after neutron irradiation with 14 MeV neutrons or (ii) the 'prompt' gamma rays from ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/4/008

    authors: Spinks TJ,Goode AW,Ranicar AS,Steere E

    更新日期:1984-04-01 00:00:00

  • A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging.

    abstract::A dedicated small-animal x-ray micro computed tomography (micro-CT) system has been developed to screen laboratory small animals such as mice and rats. The micro-CT system consists of an indirect-detection flat-panel x-ray detector with a field-of-view of 120 x 120 mm2, a microfocus x-ray source, a rotational subject ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/014

    authors: Lee SC,Kim HK,Chun IK,Cho MH,Lee SY,Cho MH

    更新日期:2003-12-21 00:00:00

  • Computational dosimetry in embryos exposed to electromagnetic plane waves over the frequency range of 10 MHz-1.5 GHz.

    abstract::This paper presents calculated specific absorption rate (SAR) dosimetry in 4 and 8 week Japanese pregnant-woman models exposed to plane waves over the frequency range of 10 MHz-1.5 GHz. Two types of 2 mm spatial-resolution pregnant-woman models comprised a woman model, which is similar to the average-sized Japanese ad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/N01

    authors: Kawai H,Nagaoka T,Watanabe S,Saito K,Takahashi M,Ito K

    更新日期:2010-01-07 00:00:00

  • A rigid motion correction method for helical computed tomography (CT).

    abstract::We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/5/2047

    authors: Kim JH,Nuyts J,Kyme A,Kuncic Z,Fulton R

    更新日期:2015-03-07 00:00:00

  • Learning image based surrogate relevance criterion for atlas selection in segmentation.

    abstract::Picking geometrically relevant atlases from the whole training set is crucial to multi-atlas based image segmentation, especially with extensive data of heterogeneous quality in the Big Data era. Unfortunately, there is very limited understanding of how currently used image similarity criteria reveal geometric relevan...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/11/4223

    authors: Zhao T,Ruan D

    更新日期:2016-06-07 00:00:00

  • Monte Carlo aided room scatter studies in the primary air kerma strength standardization of a remote afterloading 192Ir HDR source.

    abstract::Corrections for room scatter, [ksc(d, H)]RM, were derived using Monte Carlo methods for rooms of various sizes, including the brachytherapy treatment room, in which primary air kerma strength standardization of a remote afterloading microSelectron 192Ir HDR source was carried out, using a 60 cm3 spherical graphite ion...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/9/303

    authors: Selvam TP,Rajan KN,Nagarajan PS,Sethulakshmi P,Bhatt BC

    更新日期:2001-09-01 00:00:00

  • Measurement of image contrast using diffraction enhanced imaging.

    abstract::Refraction contrast of simple objects obtained using diffraction enhanced imaging (DEI) was studied and compared to conventional radiographic contrast. Lucite cylinders and nylon wires were imaged using monochromatic synchrotron radiation at the National Synchrotron Light Source (http://nslsweb. nsls.bnl.gov/nsls/Defa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/3/304

    authors: Kiss MZ,Sayers DE,Zhong Z

    更新日期:2003-02-07 00:00:00

  • Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT.

    abstract::Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe026

    authors: Hur J,Kim D,Shin YG,Lee H

    更新日期:2021-01-26 00:00:00

  • 50 μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis.

    abstract::Wafer-scale CMOS active pixel sensors (APSs) have been developed recently for x-ray imaging applications. The small pixel pitch and low noise are very promising properties for medical imaging applications such as digital breast tomosynthesis (DBT). In this work, we evaluated experimentally and through modeling the ima...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/23/8977

    authors: Zhao C,Konstantinidis AC,Zheng Y,Anaxagoras T,Speller RD,Kanicki J

    更新日期:2015-12-07 00:00:00

  • Integration of dynamic contrast-enhanced magnetic resonance imaging and T2-weighted imaging radiomic features by a canonical correlation analysis-based feature fusion method to predict histological grade in ductal breast carcinoma.

    abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fd3

    authors: Fan M,Liu Z,Xie S,Xu M,Wang S,Gao X,Li L

    更新日期:2019-10-23 00:00:00

  • Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    abstract::Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/2/016

    authors: Ziegler R,Brendel B,Rinneberg H,Nielsen T

    更新日期:2009-01-21 00:00:00

  • PDE-constrained LDDMM via geodesic shooting and inexact Gauss-Newton-Krylov optimization using the incremental adjoint Jacobi equations.

    abstract::The class of non-rigid registration methods proposed in the framework of PDE-constrained large deformation diffeomorphic metric mapping is a particularly interesting family of physically meaningful diffeomorphic registration methods. Inexact Gauss-Newton-Krylov optimization has shown an excellent numerical accuracy an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf598

    authors: Hernandez M

    更新日期:2019-01-07 00:00:00

  • The feasibility of using poroelastographic techniques for distinguishing between normal and lymphedematous tissues in vivo.

    abstract::Lymphedema is a common condition involving an abnormal accumulation of lymphatic fluid in the interstitial space that causes swelling, most often in the arm(s) and leg(s). Lymphedema is a significant lifelong concern that can be congenital or develop following cancer treatment or cancer metastasis. Common methods of e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/013

    authors: Righetti R,Garra BS,Mobbs LM,Kraemer-Chant CM,Ophir J,Krouskop TA

    更新日期:2007-11-07 00:00:00

  • Ultrasound scattering from spherical tumours.

    abstract::The interaction of biomedical ultrasound with spherical tumours in the human body is investigated using analytic methods which predict the angular distribution of the ultrasound scattered by the tumour. Both the tumour and the surrounding tissue are considered to be lossy elastic media, which support shear-wave modes ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/11/001

    authors: Hinders MK,Collins JJ,Collins MM,Fang TM,Sandri GV

    更新日期:1992-11-01 00:00:00

  • The Monte Carlo calculation of integral radiation dose in xeromammography.

    abstract::A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/1/003

    authors: Dance DR

    更新日期:1980-01-01 00:00:00

  • Quantitative analysis of synchrotron radiation intravenous angiographic images.

    abstract::A medical research protocol on clinical intravenous coronary angiography has been completed at the European Synchrotron Radiation Facility (ESRF) biomedical beamline. The aim was to investigate the accuracy of intravenous coronary angiography based on the K-edge digital subtraction technique for the detection of in-st...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/50/4/011

    authors: Sarnelli A,Nemoz C,Elleaume H,Estève F,Bertrand B,Bravin A

    更新日期:2005-02-21 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • The importance of radiometer angular response for ultraviolet phototherapy dosimetry.

    abstract::The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/4/003

    authors: Martin CJ,Currie GD,Pye SD

    更新日期:1999-04-01 00:00:00

  • Ion concentration and haematocrit as determinants of impedance in an erythrocyte suspension model of renal medullary tissue.

    abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/11/011

    authors: Niewiadomski W,Sadowski J,Badzyńska B,Rasmussen SN

    更新日期:1990-11-01 00:00:00

  • Accounting for range uncertainties in the optimization of intensity modulated proton therapy.

    abstract::Treatment plans optimized for intensity modulated proton therapy (IMPT) may be sensitive to range variations. The dose distribution may deteriorate substantially when the actual range of a pencil beam does not match the assumed range. We present two treatment planning concepts for IMPT which incorporate range uncertai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/009

    authors: Unkelbach J,Chan TC,Bortfeld T

    更新日期:2007-05-21 00:00:00

  • Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

    abstract::Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4665

    authors: Nasr AT,Alexander K,Schreiner LJ,McAuley KB

    更新日期:2015-06-21 00:00:00

  • Investigation of the performance of antiscatter grids: Monte Carlo simulation studies.

    abstract::Monte Carlo methods have been applied to the study of the performance of antiscatter grids in radiography. Photon histories for imaging with a 20 cm thick water phantom irradiated with an 80 kV x-ray spectrum were generated by Monte Carlo simulation. The scattering and absorption of the photons transmitted from the ph...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/6/002

    authors: Chan HP,Doi K

    更新日期:1982-06-01 00:00:00

  • Kinetic filtering of [(18)F]Fluorothymidine in positron emission tomography studies.

    abstract::[(18)F]Fluorothymidine (FLT) is a cell proliferation marker that undergoes predominantly hepatic metabolism and therefore shows a high level of accumulation in the liver, as well as in rapidly proliferating tumours. Furthermore, the tracer's uptake is substantial in other organs including the heart. We present a nonli...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/010

    authors: Gray KR,Contractor KB,Kenny LM,Al-Nahhas A,Shousha S,Stebbing J,Wasan HS,Coombes RC,Aboagye EO,Turkheimer FE,Rosso L

    更新日期:2010-02-07 00:00:00

  • Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

    abstract::A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/12/006

    authors: Meissner P,Jacob M,Rassow J

    更新日期:1988-12-01 00:00:00

  • Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.

    abstract::Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/6/006

    authors: Zink K,Wulff J

    更新日期:2008-03-21 00:00:00

  • The Fokker-Planck equation for coupled Brown-Néel-rotation.

    abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa186

    authors: Weizenecker J

    更新日期:2018-01-22 00:00:00