Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT.

Abstract:

:Beam hardening is inevitable due to the polychromatic X-ray spectrum and energy-dependent attenuation coefficients of materials, leading to the underestimation of artifacts arising from projection data, especially on metal regions. State-of-the-art research on beam-hardening artifacts is based on a numerical method that recursively performs computed tomography (CT) reconstruction, which leads to a heavy computational burden. To address this computational issue, we propose a constrained beam-hardening estimator that provides an efficient numerical solution via a linear combination of two images reconstructed only once during the entire process. The proposed estimator reflects the geometry of metal objects and physical characteristics of beam hardening during the transmission of polychromatic X-ray through a material. Most of the associated parameters are numerically obtained from an initial uncorrected CT image and forward projection transformation without additional optimization procedures. Only the unknown parameter regarding beam-hardening artifact is fine-tuned by linear optimization performed only in the reconstruction image domain. The proposed approach was systematically assessed using numerical simulations and phantom data for qualitative and quantitative comparisons. Compared with existing sinogram inpainting-based and model-based approaches, the proposed scheme in conjunction with the constrained beam-hardening estimator not only provided improved image quality in areas surrounding the metal but also achieved a fast beam-hardening correction due to the analytical reconstruction structure. This work may have significant implications in improving dose calculation accuracy or target volume delineation for treatment planning in radiotherapy.

journal_name

Phys Med Biol

authors

Hur J,Kim D,Shin YG,Lee H

doi

10.1088/1361-6560/abe026

subject

Has Abstract

pub_date

2021-01-26 00:00:00

eissn

0031-9155

issn

1361-6560

pub_type

杂志文章
  • T1 and extracellular volume fraction mapping in cardiac magnetic resonance: estimation of accuracy and precision of a novel algorithm.

    abstract::Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also est...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcca

    authors: Borrazzo C,Pacilio M,Galea N,Preziosi E,Carnì M,Francone M,Catalano C,Carbone I

    更新日期:2019-02-11 00:00:00

  • Temperature elevation in the eye of anatomically based human head models for plane-wave exposures.

    abstract::This study investigated the temperature elevation in the eye of anatomically based human head models for plane-wave exposures. The finite-difference time-domain method is used for analyzing electromagnetic absorption and temperature elevation. The eyes in the anatomic models have average dimensions and weight. Computa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/21/003

    authors: Hirata A,Watanabe S,Fujiwara O,Kojima M,Sasaki K,Shiozawa T

    更新日期:2007-11-07 00:00:00

  • Estimation of torque on mechanical heart valves due to magnetic resonance imaging including an estimation of the significance of the Lenz effect using a computational model.

    abstract::Mitral and aortic valve replacement is a procedure which is common in cardiac surgery. Some of these replacement valves are mechanical and contain moving metal parts. Should the patient in whom such a valve has been implanted be involved in magnetic resonance imaging, there is a possible dangerous interaction between ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/12/320

    authors: Robertson NM,Diaz-Gomez M,Condon B

    更新日期:2000-12-01 00:00:00

  • The preprocessing of retinal images for the detection of fluorescein leakage.

    abstract::Images of the human retina are routinely used in clinical practice for the diagnosis and management of eye disease. Increased permeability of retinal blood vessels, which is a clinically significant feature, can be visualized with a process known as fluorescein angiography as leakage of fluorescence dye into the surro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/1/021

    authors: Cree MJ,Olson JA,McHardy KC,Sharp PF,Forrester JV

    更新日期:1999-01-01 00:00:00

  • Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

    abstract::Developments in positron emission tomography (PET) technology have resulted in systems with finer detector elements designed to further improve spatial resolution. However, there is a limit to what extent reducing detector element size will improve spatial resolution in PET. The spatial resolution of PET imaging is li...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/019

    authors: Levin CS,Hoffman EJ

    更新日期:1999-03-01 00:00:00

  • Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo.

    abstract::Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that ver...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4627

    authors: Zettergren E,Swamy T,Runnels J,Lin CP,Niedre M

    更新日期:2012-07-21 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: the use of the extended CT-scale.

    abstract::Heterogeneity corrections for radiotherapy dose calculations are based on the electron density of the disturbing heterogeneity. However, when CT planning a radiotherapy treatment, where metallic hip implants are present, considerable artefacts are seen in the images. Often, an additional problem arises whereby no info...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/11/308

    authors: Coolens C,Childs PJ

    更新日期:2003-06-07 00:00:00

  • Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator.

    abstract::The MRI accelerator, a combination of a 6 MV linear accelerator with a 1.5 T MRI, facilitates continuous patient anatomy updates regarding translations, rotations and deformations of targets and organs at risk. Accounting for these demands high speed, online intensity-modulated radiotherapy (IMRT) re-optimization. In ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/5/1375

    authors: Bol GH,Hissoiny S,Lagendijk JJ,Raaymakers BW

    更新日期:2012-03-07 00:00:00

  • Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    abstract::Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/20/003

    authors: Qian M,Niu L,Wang Y,Jiang B,Jin Q,Jiang C,Zheng H

    更新日期:2010-10-21 00:00:00

  • Dosimetry comparison and characterisation of an Al K ultrasoft x-ray beam from an MRC cold-cathode source.

    abstract::Ultrasoft x-rays of 0.3-5 keV have provided a unique tool for the investigation of intracellular mechanisms of radiation action in biological organisms, including mammalian cells. However, their use presents unique practical problems in dosimetry and experimental design. Detailed interpretation of the biological resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/002

    authors: Hoshi M,Goodhead DT,Brenner DJ,Bance DA,Chmielewski JJ,Paciotti MA,Bradbury JN

    更新日期:1985-10-01 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance.

    abstract::Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6e38

    authors: Wang Y,Mazur TR,Park JC,Yang D,Mutic S,Li HH

    更新日期:2017-06-21 00:00:00

  • Dose effect of guidewire position in intravascular brachytherapy.

    abstract::It has been reported that the dose effects of metallic guidewires are significant in intravascular brachytherapy (IVBT) using a beta source. The purpose of this work is to investigate the dependence of these dose effects on guidewire position. The EGS4 Monte Carlo codes were used to perform the dose calculations for t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/10/309

    authors: Shih R,Hsu WL,Li XA

    更新日期:2002-05-21 00:00:00

  • Optical attenuation characteristics of breast tissues at visible and near-infrared wavelengths.

    abstract::Optical experiments are described for measuring the attenuation characteristics of breast tissues at visible and near-infrared wavelengths. Total attenuation coefficients post mortem were measured directly in thin tissue sections. They are usually within the range from 10 to 30 mm-1, are rather higher in fat than in f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/5/002

    authors: Key H,Davies ER,Jackson PC,Wells PN

    更新日期:1991-05-01 00:00:00

  • First in-beam PET measurement of beta+ radioactivity induced by hard photon beams.

    abstract::In this note, we present the first experimental results of in-beam PET measurements during high energy photon phantom irradiation. An inhomogeneous phantom was irradiated with pulsed 34 MV bremsstrahlung. The measurements have been conducted with a dedicated double head positron camera. A high material contrast could ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/20/N01

    authors: Kluge T,Möckel D,Pawelke J,Enghardt W

    更新日期:2007-10-21 00:00:00

  • The sliding slit test for dynamic IMRT: a useful tool for adjustment of MLC related parameters.

    abstract::For treatments with dynamic intensity modulated radiotherapy (IMRT), the adjustment of multileaf collimator (MLC) parameters affecting both the optimization algorithm and dose distributions is crucial. The main parameters characterizing the MLC are the transmission (T) and the dosimetric leaf separation (DLS). The aim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/4/001

    authors: Chauvet I,Petitfils A,Lehobey C,Kristner JY,Brunet Y,Lembrez R,Gaboriaud G,Mazal A,Zefkili S,Rosenwald JC

    更新日期:2005-02-21 00:00:00

  • A method for estimating radiation interaction coefficients for tissues from single energy CT.

    abstract::A parametric model for the x-ray linear attenuation coefficient is used to describe the compositional dependence of Hounsfield numbers measured by medical CT scanners. Measurements with materials of known density and composition, that span and evenly sample the compositional range of tissues, are written as linear sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/23/7479

    authors: Midgley SM

    更新日期:2014-12-07 00:00:00

  • Evolutionary pruning of transfer learned deep convolutional neural network for breast cancer diagnosis in digital breast tomosynthesis.

    abstract::Deep learning models are highly parameterized, resulting in difficulty in inference and transfer learning for image recognition tasks. In this work, we propose a layered pathway evolution method to compress a deep convolutional neural network (DCNN) for classification of masses in digital breast tomosynthesis (DBT). T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabb5b

    authors: Samala RK,Chan HP,Hadjiiski LM,Helvie MA,Richter C,Cha K

    更新日期:2018-05-01 00:00:00

  • Diffusion coefficient for photon transport in turbid media.

    abstract::Light propagation in a turbid medium is considered using the linear transport equation. The existence of a diffusion length is proved for the Henyey-Greenstein scattering kernel for all absorption ratios. Numerical methods are given that allow accurate computation of the diffusion coefficient quite easily. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/23/012

    authors: Sahni DC,Dahl EB,Sjöstrand NG

    更新日期:2003-12-07 00:00:00

  • The dose--response relation for rat spinal cord paralysis analyzed in terms of the effective size of the functional subunit.

    abstract::Radiobiological models for estimating normal tissue complication probability (NTCP) are increasingly used in order to quantify or optimize the clinical outcome of radiation therapy. A good NTCP model should fulfill at least the following two requirements: (a) it should predict the sigmoid shape of the corresponding do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/22/016

    authors: Adamus-Górka M,Mavroidis P,Brahme A,Lind BK

    更新日期:2008-11-21 00:00:00

  • A novel microbubble construct for intracardiac or intravascular MR manometry: a theoretical study.

    abstract::It has been demonstrated that gas-filled microbubble contrast agents, based on their volume changes, can serve as pressure probes in an MR field. It was recently reported that such an MR-based pressure measurement with microbubbles at 1.5 T must make use of microbubbles that have a volumetric magnetic susceptibility d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/20/001

    authors: Dharmakumar R,Plewes DB,Wright GA

    更新日期:2005-10-21 00:00:00

  • Suitability of EBT3 GafChromic film for quality assurance in MR-guided radiotherapy at 0.35 T with and without real-time MR imaging.

    abstract::The 0.35 T 60Co MRIdian system (ViewRay Inc., Mountain View) has been in clinical use in our institution since May 2016. For quality assurance (QA) of dose delivery and end-to-end testing for this machine, a reliable dosimeter is required. However, it is possible that a magnetic field may cause perturbations to dosime...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad58d

    authors: Barten DLJ,Hoffmans D,Palacios MA,Heukelom S,van Battum LJ

    更新日期:2018-08-20 00:00:00

  • Computer-aided diagnosis of lung cancer: the effect of training data sets on classification accuracy of lung nodules.

    abstract::This study aims to develop a computer-aided diagnosis (CADx) scheme for classification between malignant and benign lung nodules, and also assess whether CADx performance changes in detecting nodules associated with early and advanced stage lung cancer. The study involves 243 biopsy-confirmed pulmonary nodules. Among ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa610

    authors: Gong J,Liu JY,Sun XW,Zheng B,Nie SD

    更新日期:2018-02-05 00:00:00

  • The Hug-Kellerer equation as the universal cell survival curve.

    abstract::The Hug-Kellerer (H-K) equation is one of the earliest proposed radiation cell survival curves. We examine this equation in view of the recent perceived need for a universal cell survival curve which would be applicable to single radiation fractions at high doses. We derive relationships between the three parameters o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/10/N01

    authors: Ekstrand KE

    更新日期:2010-05-21 00:00:00

  • Filtered back-projection reconstruction for attenuation proton CT along most likely paths.

    abstract::This work investigates the attenuation of a proton beam to reconstruct the map of the linear attenuation coefficient of a material which is mainly caused by the inelastic interactions of protons with matter. Attenuation proton computed tomography (pCT) suffers from a poor spatial resolution due to multiple Coulomb sca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/3258

    authors: Quiñones CT,Létang JM,Rit S

    更新日期:2016-05-07 00:00:00

  • Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs).

    abstract::Recently, the Task Group 103 of the International Commission on Radiological Protection (ICRP) has developed new mesh-type reference computational phantoms (MRCPs) for adult male and female. When compared to the current voxel-type reference computational phantoms in ICRP Publication 110, the MRCPs have several advanta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aafcdb

    authors: Lee H,Yeom YS,Nguyen TT,Choi C,Han H,Shin B,Zhang X,Kim CH,Chung BS,Zankl M

    更新日期:2019-02-05 00:00:00

  • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

    abstract::A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at differe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/018

    authors: Marchant TE,Amer AM,Moore CJ

    更新日期:2008-02-21 00:00:00

  • MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab9d1

    authors: Omidvari N,Topping G,Cabello J,Paul S,Schwaiger M,Ziegler SI

    更新日期:2018-05-01 00:00:00