Measurement of total body nitrogen and oxygen by irradiation with cyclotron neutrons and 'delayed' gamma ray counting.

Abstract:

:Measurement of total body nitrogen is assuming increasing importance in the nutritional evaluation of seriously ill patients. Nitrogen has been previously measured either by counting (i) the annihilation radiation from 13N immediately after neutron irradiation with 14 MeV neutrons or (ii) the 'prompt' gamma rays from thermal neutron capture by 14N during irradiation with 14 MeV neutrons or with those produced by isotopic sources or a cyclotron. The present work describes studies into the feasibility of measuring 13N produced by irradiation with a neutron beam from the MRC Cyclotron. A complication of this method is that 13N is also produced in a reaction with 16O. Direct measurement of oxygen by use of the reactions 16O(n, p)16N or 16O(n, 2n)15O enables this interference to be estimated. The former reaction is possible with both 14 meV and cyclotron-produced neutrons but the 7.1 s half-life of 16N requires detectors to be placed in or very close to the irradiation site. In our particular circumstances this is not possible but the more energetic cyclotron neutron spectrum allows the production of 15O which has a half-life of 2.05 min and can be measured in a remote whole-body counter. A disadvantage with the cyclotron beam, in comparison with 14 MeV neutrons, is that a higher dose is required for similar accuracy. A reproducibility of about 4% is obtained with a dose equivalent of 0.01 Sv.

journal_name

Phys Med Biol

authors

Spinks TJ,Goode AW,Ranicar AS,Steere E

doi

10.1088/0031-9155/29/4/008

subject

Has Abstract

pub_date

1984-04-01 00:00:00

pages

385-94

issue

4

eissn

0031-9155

issn

1361-6560

journal_volume

29

pub_type

杂志文章
  • Understanding radionuclide production in gas target systems: the effect of adsorption on the target body.

    abstract::Gas target systems have been used for decades on cyclotrons to produce radionuclides for medical imaging. However, the activity recovered from such targets is often lower than its theoretically predicted value. Past research has suggested that nuclide interactions with the walls of the target body may play a key role ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aadf7b

    authors: Zacchia NA,Buckley KR,Martinez GM,Ruth TJ,Martinez DM,Hoehr C

    更新日期:2018-09-28 00:00:00

  • Changes in lung tumor shape during respiration.

    abstract::Evidence that some lung tumors change shape during respiration is derived from respiratory gated CT data by statistical shape modeling and image manipulation. Some tumors behave as rigid objects while others show systematic shape changes. Two views of lung motion are presented to allow analysis of the results. In the ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/4/919

    authors: Kyriakou E,McKenzie DR

    更新日期:2012-02-21 00:00:00

  • Comments on 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy'.

    abstract::By analyzing the radiobiological model, and the equations derived from the model, it is shown that the main results of the article 'The influence of dose heterogeneity on tumor control probability in fractionated radiation therapy' by Wiklund et al (2011 Phys. Med. Biol. 56 7585-600) are valid only under the condition...

    journal_title:Physics in medicine and biology

    pub_type: 评论,信件

    doi:10.1088/0031-9155/58/18/6585

    authors: Grusell E

    更新日期:2013-09-21 00:00:00

  • Dual-head gamma camera system for intraoperative localization of radioactive seeds.

    abstract::Breast-conserving surgery is a standard option for the treatment of patients with early-stage breast cancer. This form of surgery may result in incomplete excision of the tumor. Iodine-125 labeled titanium seeds are currently used in clinical practice to reduce the number of incomplete excisions. It seems likely that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7655

    authors: Arsenali B,de Jong HW,Viergever MA,Dickerscheid DB,Beijst C,Gilhuijs KG

    更新日期:2015-10-07 00:00:00

  • Influence of the SURLAS applicator on radiation dose distributions during simultaneous thermoradiotherapy with helical tomotherapy.

    abstract::Simultaneous thermoradiotherapy has been shown to maximize the effect of hyperthermia as a radiation sensitizer in cancer treatment. Here we follow our previous work on feasibility of thermoradiotherapy with the scanning ultrasound reflector linear array system (SURLAS) and TomoTherapy HiArt treatment system, and inve...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/10/004

    authors: Novák P,Peñagarícano JA,Nahirnyak V,Corry P,Moros EG

    更新日期:2008-05-21 00:00:00

  • A multi-frequency sparse hemispherical ultrasound phased array for microbubble-mediated transcranial therapy and simultaneous cavitation mapping.

    abstract::Focused ultrasound (FUS) phased arrays show promise for non-invasive brain therapy. However, the majority of them are limited to a single transmit/receive frequency and therefore lack the versatility to expose and monitor the treatment volume. Multi-frequency arrays could offer variable transmit focal sizes under a fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/24/8476

    authors: Deng L,O'Reilly MA,Jones RM,An R,Hynynen K

    更新日期:2016-12-21 00:00:00

  • 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.

    abstract::Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/749

    authors: Chin E,Loewen SK,Nichol A,Otto K

    更新日期:2013-02-21 00:00:00

  • Power deposition in the head and neck of an anatomically based human body model for plane wave exposures.

    abstract::At certain frequencies, when the human head becomes a resonant structure, the power absorbed by the head and neck, when the body is exposed to a vertically polarized plane wave propagating from front to back, becomes significantly larger than would ordinarily be expected from its shadow cross section. This has possibl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/026

    authors: Tinniswood AD,Furse CM,Gandhi OP

    更新日期:1998-08-01 00:00:00

  • Female pelvic synthetic CT generation based on joint intensity and shape analysis.

    abstract::Using MRI for radiotherapy treatment planning and image guidance is appealing as it provides superior soft tissue information over CT scans and avoids possible systematic errors introduced by aligning MR to CT images. This study presents a method that generates Synthetic CT (MRCT) volumes by performing probabilistic t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/8/2935

    authors: Liu L,Jolly S,Cao Y,Vineberg K,Fessler JA,Balter JM

    更新日期:2017-04-21 00:00:00

  • Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    abstract::For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of det...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/002

    authors: Sykes JR,Lindsay R,Dean CJ,Brettle DS,Magee DR,Thwaites DI

    更新日期:2008-10-07 00:00:00

  • Terahertz near-field imaging.

    abstract::A near-field probe is described that enables high spatial resolution imaging with terahertz (THz) pulses. The spatial resolution capabilities of the system lie in the range of few microns and we demonstrate a resolution of 7 microm using broad-banded THz pulses with an intensity maximum near 0.5 THz. We present a stud...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/21/308

    authors: Federici JF,Mitrofanov O,Lee M,Hsu JW,Brener I,Harel R,Wynn JD,Pfeiffer LN,West KW

    更新日期:2002-11-07 00:00:00

  • Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

    abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4635

    authors: Nemallapudi MV,Gundacker S,Lecoq P,Auffray E,Ferri A,Gola A,Piemonte C

    更新日期:2015-06-21 00:00:00

  • Separating components of variation in measurement series using maximum likelihood estimation. Application to patient position data in radiotherapy.

    abstract::Maximum likelihood estimation (MLE) is presented as a statistical tool to evaluate the contribution of measurement error to any measurement series where the same quantity is measured using different independent methods. The technique was tested against artificial data sets; generated for values of underlying variation...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/6019

    authors: Sage JP,Mayles WP,Mayles HM,Syndikus I

    更新日期:2014-10-21 00:00:00

  • Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT.

    abstract::Optimization-based algorithms for image reconstruction in multispectral (or photon-counting) computed tomography (MCT) remains a topic of active research. The challenge of optimization-based image reconstruction in MCT stems from the inherently non-linear data model that can lead to a non-convex optimization program f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a4b

    authors: Chen B,Zhang Z,Sidky EY,Xia D,Pan X

    更新日期:2017-11-02 00:00:00

  • Examination of errors caused by random summing in in vivo prompt gamma ray analysis.

    abstract::A technique is described for examining the mode of operation of radiation detectors and estimating the losses and gains caused by random summing effects in spectra acquired at high counting rates. The technique is applied to estimating the errors caused by random summing when measuring the amounts of carbon and nitrog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/8/010

    authors: Yankuba S,Oldroyd B,Metcalfe SC,Godfrey JE,Oxby CB

    更新日期:1989-08-01 00:00:00

  • Adaptive anisotropic diffusion filtering of Monte Carlo dose distributions.

    abstract::The Monte Carlo method is the most accurate method for radiotherapy dose calculations, if used correctly. However, any Monte Carlo dose calculation is burdened with statistical noise. In this paper, denoising of Monte Carlo dose distributions with a three-dimensional adaptive anisotropic diffusion method was investiga...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/17/303

    authors: Miao B,Jeraj R,Bao S,Mackie TR

    更新日期:2003-09-07 00:00:00

  • Measurement of scattered radiation in a volumetric 64-slice CT scanner using three experimental techniques.

    abstract::Compton scatter poses a significant threat to volumetric x-ray computed tomography, bringing cupping and streak artefacts thus impacting qualitative and quantitative imaging procedures. To perform appropriate scatter compensation, it is necessary to estimate the magnitude and spatial distribution of x-ray scatter. The...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/8/010

    authors: Akbarzadeh A,Ay MR,Ghadiri H,Sarkar S,Zaidi H

    更新日期:2010-04-21 00:00:00

  • A dedicated phantom design for positron emission mammography performance evaluation.

    abstract::A standard protocol for performance evaluation of positron emission mammography (PEM) systems has not yet been established. In this work we propose a methodology based on the design of specific phantoms for this imaging modality with component dimensions in accordance with typical breast lesion sizes together with the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba7d1

    authors: Torres-Urzúa LF,Alva-Sanchez H,Martinez-Davalos A,García-Pérez FO,Peruyero-Rivas RM,Rodriguez-Villafuerte M

    更新日期:2020-07-21 00:00:00

  • Investigation of ultrasonic properties of PAG and MAGIC polymer gel dosimeters.

    abstract::Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range invest...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/24/307

    authors: Mather ML,De Deene Y,Whittaker AK,Simon GP,Rutgers R,Baldock C

    更新日期:2002-12-21 00:00:00

  • Evaluation of deformable image registration and a motion model in CT images with limited features.

    abstract::Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2539

    authors: Liu F,Hu Y,Zhang Q,Kincaid R,Goodman KA,Mageras GS

    更新日期:2012-05-07 00:00:00

  • Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model.

    abstract::The classical Sievert integral method is a valuable tool for dose rate calculations around brachytherapy sources, combining simplicity with reasonable computational times. However, its accuracy in predicting dose rate anisotropy around 192Ir brachytherapy sources has been repeatedly put into question. In this work, we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/309

    authors: Karaiskos P,Angelopoulos A,Baras P,Rozaki-Mavrouli H,Sandilos P,Vlachos L,Sakelliou L

    更新日期:2000-02-01 00:00:00

  • A control systems approach for the simulation of renal dynamic software phantoms for nuclear medicine.

    abstract::For renal dynamic studies, the COST B2 hybrid phantom is an example of an artificially created software phantom. Although this phantom is useful, it is not possible to implement the phantom in a self-consistent fashion to produce, for example, a collection of tracer in the bladder which is related to the flow from the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/008

    authors: Houston AS,Sampson WF,Jose RM,Boyce JF

    更新日期:1999-02-01 00:00:00

  • Hybrid scatter correction applied to quantitative holmium-166 SPECT.

    abstract::Ho-166 is a combined beta-gamma emitter of which the betas can be used therapeutically. From the 81 keV gammas of Ho-166, SPECT images can be obtained, which give opportunities to guide Ho-166 therapy. Accurate reconstruction of Ho-166 images is currently hampered by photopeak-scatter in the patient, down-scatter in t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/004

    authors: de Wit TC,Xiao J,Nijsen JF,van het Schip FD,Staelens SG,van Rijk PP,Beekman FJ

    更新日期:2006-10-07 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • The biomechanics of simple steatosis and steatohepatitis.

    abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aac09a

    authors: Parker KJ,Ormachea J,Drage MG,Kim H,Hah Z

    更新日期:2018-05-17 00:00:00

  • Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

    abstract::Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/947

    authors: Cao Q,Thawait G,Gang GJ,Zbijewski W,Reigel T,Brown T,Corner B,Demehri S,Siewerdsen JH

    更新日期:2015-02-07 00:00:00

  • Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

    abstract::Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/9/2441

    authors: Ding A,Mille MM,Liu T,Caracappa PF,Xu XG

    更新日期:2012-05-07 00:00:00

  • Modeling localized delivery of Doxorubicin to the brain following focused ultrasound enhanced blood-brain barrier permeability.

    abstract::Doxorubicin (Dox) is a well-established chemotherapeutic agent, however it has limited efficacy in treating brain malignancies due to the presence of the blood-brain barrier (BBB). Recent preclinical studies have demonstrated that focused ultrasound induced BBB disruption (BBBD) enables efficient delivery of Dox to th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/20/5987

    authors: Nhan T,Burgess A,Lilge L,Hynynen K

    更新日期:2014-10-21 00:00:00

  • Calculation of turnover rates in stable-isotope studies.

    abstract::Tserng and Kalhan have raised the question of the appropriate equation to use for the measurement of turnover rate in a stable-isotope study. In a comparison of glucose turnover measured with 2H-glucose and with 13C-glucose they used five apparently different equations and obtained conflicting answers. There is, howev...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/013

    authors: Wootton R,Ford GC,Cheng KN,Halliday D

    更新日期:1985-10-01 00:00:00

  • Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

    abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/3/001

    authors: Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

    更新日期:1988-03-01 00:00:00