Leuco-crystal-violet micelle gel dosimeters: I. Influence of recipe components and potential sensitizers.

Abstract:

:Radiochromic leuco crystal violet (LCV) micelle gel dosimeters are promising three-dimensional radiation dosimeters because of their spatial stability and suitability for optical readout. The effects of surfactant type and surfactant concentration on dose sensitivity of LCV micelle gels are tested, demonstrating that dose sensitivity and initial colour of the gel increases with increasing Triton x-100 (Tx100) concentration. Using Cetyl Trimethyl Ammonium Bromide (CTAB) in place of Tx100 produces gels that are nearly colourless prior to irradiation, but reduces the dose sensitivity. The separate effects of Tri-chloro acetic acid concentration and pH are investigated, revealing that controlling the pH near 3.6 is crucial for achieving high dose sensitivity. The sensitizing effect of chlorinated species on dose sensitivity is tested using 2,2,2-trichloroethanol (TCE), chloroform, and 1,1,1-trichloro-2-methyl-2-propanol hemihydrate. TCE gives the largest improvement in dose sensitivity and is recommended for use in micelle gel dosimeters because it is less volatile and safer to use than chloroform. Preliminary experiments on a new gel containing CTAB as the surfactant and TCE show that this new gel gives a dose sensitivity that is 24% higher than that of previous LCV micelle gels and is nearly colourless prior to irradiation.

journal_name

Phys Med Biol

authors

Nasr AT,Alexander K,Schreiner LJ,McAuley KB

doi

10.1088/0031-9155/60/12/4665

subject

Has Abstract

pub_date

2015-06-21 00:00:00

pages

4665-83

issue

12

eissn

0031-9155

issn

1361-6560

journal_volume

60

pub_type

杂志文章
  • Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks (RNNs).

    abstract::Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3564

    authors: Liu C,Li Z,Hu W,Xing L,Peng H

    更新日期:2019-09-04 00:00:00

  • The validation of tomotherapy dose calculations in low-density lung media.

    abstract::The dose-calculation accuracy of the tomotherapy Hi-Art II(R) (Tomotherapy, Inc., Madison, WI) treatment planning system (TPS) in the presence of low-density lung media was investigated. In this evaluation, a custom-designed heterogeneous phantom mimicking the mediastinum geometry was used. Gammex LN300 and balsa wood...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/8/004

    authors: Chaudhari SR,Pechenaya OL,Goddu SM,Mutic S,Rangaraj D,Bradley JD,Low D

    更新日期:2009-04-21 00:00:00

  • Dosimetry robustness with stochastic optimization.

    abstract::All radiation therapy treatment planning relies on accurate dose calculation. Uncertainties in dosimetric prediction can significantly degrade an otherwise optimal plan. In this work, we introduce a robust optimization method which handles dosimetric errors and warrants for high-quality IMRT plans. Unlike other dose e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/11/010

    authors: Nohadani O,Seco J,Martin BC,Bortfeld T

    更新日期:2009-06-07 00:00:00

  • Precise measurement of cerebral blood flow in newborn piglets from the bolus passage of indocyanine green.

    abstract::Indocyanine green (ICG) is a near-infrared dye that has the potential to be used as a tracer for the minimally invasive measurement of cerebral blood flow (CBF). In order to examine the technique, the arterial and cerebral concentrations of ICG were measured in newborn piglets during the bolus passage of ICG at normoc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/8/312

    authors: Springett R,Sakata Y,Delpy DT

    更新日期:2001-08-01 00:00:00

  • Modeling the radiation-induced cell death in a therapeutic proton beam using thermoluminescent detectors and radiation transport simulations.

    abstract::Changes in the relative biological effectiveness (RBE) of the radiation-induced cell killing of human salivary glands (HSG) were assessed along the Bragg peak of a 60 MeV clinical proton beam by means of coupling biophysical models with the results of Monte Carlo radiation transport simulations and experimental measur...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab491f

    authors: Parisi A,Olko P,Swakoń J,Horwacik T,Jabłoński H,Malinowski L,Nowak T,Struelens L,Vanhavere F

    更新日期:2020-01-10 00:00:00

  • Super-resolution reconstruction of 4D-CT lung data via patch-based low-rank matrix reconstruction.

    abstract::Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related heal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8a48

    authors: Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Y

    更新日期:2017-10-03 00:00:00

  • Volume estimation of low-contrast lesions with CT: a comparison of performances from a phantom study, simulations and theoretical analysis.

    abstract::Measurements of lung nodule volume with multi-detector computed tomography (MDCT) have been shown to be more accurate and precise compared to conventional lower dimensional measurements. Quantifying the size of lesions is potentially more difficult when the object-to-background contrast is low as with lesions in the l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/671

    authors: Li Q,Gavrielides MA,Zeng R,Myers KJ,Sahiner B,Petrick N

    更新日期:2015-01-21 00:00:00

  • Comparison of recent codes of practice for high-energy photon dosimetry.

    abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/006

    authors: Mijnheer BJ,Wittkämper FW

    更新日期:1986-04-01 00:00:00

  • A static beam delivery device for fast scanning proton arc-therapy.

    abstract::Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called "arcs"). This technique can potentially ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe02b

    authors: Nesteruk KP,Bolsi A,Lomax AJ,Meer D,van de Water S,Schippers JM

    更新日期:2021-01-26 00:00:00

  • The measurement of silicon in a lung phantom--a comparison of two nuclear reactions for in vivo activation analysis.

    abstract::The amount of silica in the human lung may be estimated by measurement of silicon using in vivo neutron activation analysis. A pulsed, fast neutron beam, produced with a 2 MV Van de Graaff generator using the 2H + 2H reaction, was used to irradiate a Si-doped chest phantom in order to determine minimum detection limit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/6/004

    authors: Kacperek A,Ryde SJ,Evans CJ,Dutton J,Morgan WD,Sivyer A

    更新日期:1993-06-01 00:00:00

  • Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer.

    abstract::Image-guided radiation therapy using implanted fiducial markers is a common solution for prostate localization to improve targeting accuracy. However, fiducials that are typically used for conventional photon radiotherapy cause large dose perturbations in patients who receive proton radiotherapy. A proposed solution h...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/23/S13

    authors: Cheung J,Kudchadker RJ,Zhu XR,Lee AK,Newhauser WD

    更新日期:2010-12-07 00:00:00

  • Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry.

    abstract::The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual trace...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3585

    authors: White SA,Landry G,van Gils F,Verhaegen F,Reniers B

    更新日期:2012-06-07 00:00:00

  • Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    abstract::Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with wat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/16/017

    authors: Cirio R,Garelli E,Schulte R,Amerio S,Boriano A,Bourhaleb F,Coutrakon G,Donetti M,Giordanengo S,Koss P,Madon E,Marchetto F,Nastasi U,Peroni C,Santuari D,Sardo A,Scielzo G,Stasi M,Trevisiol E

    更新日期:2004-08-21 00:00:00

  • A double-tuned (1)H/(23)Na dual resonator system for tissue sodium concentration measurements in the rat brain via Na-MRI.

    abstract::A method for quantifying the tissue sodium concentration (TSC) in the rat brain from ²³Na-MR images was developed. TSC is known to change in a variety of common human diseases and holds considerable potential to contribute to their study; however, its accurate measurement in small laboratory animals has been hindered ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/24/019

    authors: Wetterling F,Tabbert M,Junge S,Gallagher L,Macrae IM,Fagan AJ

    更新日期:2010-12-21 00:00:00

  • Effect on tumour control of time interval between surgery and postoperative radiotherapy: an empirical approach using Monte Carlo simulation.

    abstract::In this work, a procedure, based on Monte Carlo techniques, to analyse the effect on the tumour control probability of the time interval between surgery and postoperative radiotherapy is presented. The approach includes the tumour growth as well as the survival of tumour cells undergoing fractionated radiotherapy. Bot...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/13/005

    authors: Al-Dweri FM,Guirado D,Lallena AM,Pedraza V

    更新日期:2004-07-07 00:00:00

  • Counting losses in multidetector radiation counters.

    abstract::We examined the reasons for the reduction in response of a multidetector radiation counting system when operated at high count-rates and established a convenient method of correction which is accurate to within +/- 1% up to 0-6 X 10(5) counts per second. In its application the method uses the observed count-rates from...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/009

    authors: Oxby CB,Oldroyd B,Appleby DB

    更新日期:1976-01-01 00:00:00

  • A novel technique for measuring the low-dose envelope of pencil-beam scanning spot profiles.

    abstract::To investigate the profile measurement capabilities of an IBA-Dosimetry scintillation detector and to assess its feasibility for determining the low-intensity tails of pencil-beam scanning spots, the responses of the scintillation detector and Gafchromic EBT2 film to a 115 MeV proton spot were measured in-air at the i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/12/N171

    authors: Lin L,Ainsley CG,Mertens T,De Wilde O,Talla PT,McDonough JE

    更新日期:2013-06-21 00:00:00

  • Implementation and analysis of relief patterns of the surface of benign and malignant lesions of the skin by microtopography.

    abstract::The objective of this study was to be able to distinguish between healthy skin tissue and malignant ones, furthermore determining a unique pattern of roughness for each skin lesion by microtopographic analysis of the skin surface of Mexican patients during the period from April to October 2002. The standard technique ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/23/008

    authors: del Carmen López Pacheco M,da Cunha Martins-Costa MF,Zapata AJ,Cherit JD,Gallegos ER

    更新日期:2005-12-07 00:00:00

  • Accelerated time-of-flight (TOF) PET image reconstruction using TOF bin subsetization and TOF weighting matrix pre-computation.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) technology has recently regained popularity in clinical PET studies for improving image quality and lesion detectability. Using TOF information, the spatial location of annihilation events is confined to a number of image voxels along each line of response, there...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/1309

    authors: Mehranian A,Kotasidis F,Zaidi H

    更新日期:2016-02-07 00:00:00

  • Evaluation of inverse methods and head models for EEG source localization using a human skull phantom.

    abstract::We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/1/306

    authors: Baillet S,Riera JJ,Marin G,Mangin JF,Aubert J,Garnero L

    更新日期:2001-01-01 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • Dose conversion coefficients for paediatric CT examinations with automatic tube current modulation.

    abstract::A common dose-saving technique used in modern CT devices is automatic tube current modulation (TCM), which was originally designed to also reduce the dose in paediatric CT patients. In order to be able to deduce detailed organ doses of paediatric models, dose conversion coefficients normalized to CTDI(vol) for an eigh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/20/6309

    authors: Schlattl H,Zankl M,Becker J,Hoeschen C

    更新日期:2012-10-21 00:00:00

  • Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams.

    abstract::The measurement of output factors (OF) for the small photon beams generated by Leksell Gamma Knife® (LGK) radiotherapy units is a challenge for the physicist due to the under or over estimation of these factors by a vast majority of the detectors commercially available. Output correction factors, introduced in the int...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/10/3959

    authors: Benmakhlouf H,Johansson J,Paddick I,Andreo P

    更新日期:2015-05-21 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Cross-sections for the inactivation of ribonuclease by slow heavy ions.

    abstract::Average cross-sections for inactivation of dry ribonuclease by H, He and N projectiles with energies between 100 eV and 10 keV are presented. The trend of the damage cross-sections with particle energy is consistent with the trend of the molecular quasi-elastic scattering and ionization cross-sections. A tentative rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/6/005

    authors: Watt DE,Sutcliffe JF

    更新日期:1975-11-01 00:00:00

  • Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging.

    abstract::With high-dose administration of (90)Y labeled antibodies, it is possible to image (90)Y without an admixture of (111)In. We have earlier shown that it is possible to perform quantitative (90)Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/19/014

    authors: Minarik D,Ljungberg M,Segars P,Gleisner KS

    更新日期:2009-10-07 00:00:00

  • A dose calculation method including scatter for IMRT optimization.

    abstract::IMRT optimization is an iterative process in which many dose calculations may be necessary. A fast and accurate dose calculation engine is essential for the optimization program to converge to a reliable solution in a reasonable time. Previously we developed a fast dose calculation method for IMRT optimization based o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/19/011

    authors: Wu Q

    更新日期:2004-10-07 00:00:00

  • Introducing the Jacobian-volume-histogram of deforming organs: application to parotid shrinkage evaluation.

    abstract::The Jacobian of the deformation field of elastic registration between images taken during radiotherapy is a measure of inter-fraction local deformation. The histogram of the Jacobian values (Jac) within an organ was introduced (JVH-Jacobian-volume-histogram) and first applied in quantifying parotid shrinkage. MVCTs of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/008

    authors: Fiorino C,Maggiulli E,Broggi S,Liberini S,Cattaneo GM,Dell'oca I,Faggiano E,Di Muzio N,Calandrino R,Rizzo G

    更新日期:2011-06-07 00:00:00

  • Initial assessment of a simple system for frequency domain diffuse optical tomography.

    abstract::Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/10/011

    authors: Pogue BW,Patterson MS,Jiang H,Paulsen KD

    更新日期:1995-10-01 00:00:00

  • Derivation of mean dose tolerances for new fractionation schemes and treatment modalities.

    abstract::Avoiding toxicities in radiotherapy requires the knowledge of tolerable organ doses. For new, experimental fractionation schemes (e.g. hypofractionation) these are typically derived from traditional schedules using the biologically effective dose (BED) model. In this report we investigate the difficulties of establish...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9836

    authors: Perkó Z,Bortfeld T,Hong T,Wolfgang J,Unkelbach J

    更新日期:2018-02-05 00:00:00