Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

Abstract:

:Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies.

journal_name

Phys Med Biol

authors

Tan S,Yao J,Yao L,Ward MM

doi

10.1088/0031-9155/57/14/4683

subject

Has Abstract

pub_date

2012-07-21 00:00:00

pages

4683-704

issue

14

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry.

    abstract::This paper investigates cone-beam tomography for a wide class of x-ray source trajectories called saddles. In particular, a mathematical analysis of the number of intersections between a saddle and an arbitrary plane is given. This analysis demonstrates that axially truncated cone-beam projections acquired along a sad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/014

    authors: Pack JD,Noo F,Kudo H

    更新日期:2004-06-07 00:00:00

  • Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle.

    abstract::Amorphous silicon electronic portal imaging devices (EPIDs) are used to perform routine quality control (QC) checks on the multileaf collimators (MLCs) at this centre. Presently, these checks are performed at gantry angle 0 degrees and are considered to be valid for all other angles. Since therapeutic procedures regul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/2/013

    authors: Clarke MF,Budgell GJ

    更新日期:2008-01-21 00:00:00

  • Identifying critical human subpopulations by age groups: radioactivity and the lung.

    abstract::This work studies the effect of age on lung dose commitments arising from the inhalation of an atmosphere containing radionuclides of varying half-lives and physical sizes. This dependence is significant in many cases, approaching a ratio of 2 in several instances when the maximum dose at a given age is compared with ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/27/4/005

    authors: Crawford DJ

    更新日期:1982-04-01 00:00:00

  • Exploiting flow to control the in vitro spatiotemporal distribution of microbubble-seeded acoustic cavitation activity in ultrasound therapy.

    abstract::Focused ultrasound and microbubbles have been extensively used to generate therapeutic bioeffects. Despite encouraging in vivo results, there remains poor control of the magnitude and spatial distribution of these bioeffects due to the limited ability of conventional pulse shapes and sequences to control cavitation dy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/22/6941

    authors: Pouliopoulos AN,Bonaccorsi S,Choi JJ

    更新日期:2014-11-21 00:00:00

  • Characterization of single α-tracks by photoresist detection and AFM analysis-focus on biomedical science and technology.

    abstract::The interactions between energetic ions and biological and/or organic target materials have recently attracted theoretical and experimental attention, due to their implications for detector and device technologies, and for therapeutic applications. Most of the attention has focused on detection of the primary ionizati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/21/7673

    authors: Falzone N,Myhra S,Chakalova R,Hill MA,Thomson J,Vallis KA

    更新日期:2013-11-07 00:00:00

  • Accurate Monte Carlo modelling of the back compartments of SPECT cameras.

    abstract::Today, new single photon emission computed tomography (SPECT) reconstruction techniques rely on accurate Monte Carlo (MC) simulations to optimize reconstructed images. However, existing MC scintillation camera models which usually include an accurate description of the collimator and crystal, lack correct implementati...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/1/006

    authors: Rault E,Staelens S,Van Holen R,De Beenhouwer J,Vandenberghe S

    更新日期:2011-01-07 00:00:00

  • Ultrasound transmission tomography image reconstruction with a fully convolutional neural network.

    abstract::Image reconstruction of ultrasound computed tomography based on the wave equation is able to show much more structural details than simpler ray-based image reconstruction methods. However, to invert the wave-based forward model is computationally demanding. To address this problem, we develop an efficient fully learne...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb5c3

    authors: Zhao W,Wang H,Gemmeke H,van Dongen KWA,Hopp T,Hesser J

    更新日期:2020-11-27 00:00:00

  • A neutron source with an effective energy of 0-5 keV.

    abstract::Calculations indicate that an assembly consisting of an antimony-beryllium source at the centre of a 4 cm radius water sphere surrounded by a 1 mm thick shell of boron-10 will emit neutrons with a broad spectrum at intermediate energies. A device based on this design was constructed using a water-filled, boron-carbide...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/21/1/007

    authors: Harvey JR,Bending RC

    更新日期:1976-01-01 00:00:00

  • Quality assurance in brachytherapy: the displacement effect in the vicinity of 60Co and 192Ir brachytherapy sources.

    abstract::Cylindrical ionization chambers with varying radii have been used to determine the displacement effect at distances between 10 mm and 40 mm from 60Co and 192Ir brachytherapy sources. Agreement with published values of the displacement factor for external 60Co beams is obtained. The shift between the centre of the ioni...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/10/009

    authors: Tölli H,Johansson KA

    更新日期:1993-10-01 00:00:00

  • Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 System: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors.

    abstract::Monte Carlo simulation was used to calculate correction factors for output factor (OF), percentage depth-dose (PDD), and off-axis ratio (OAR) measurements with the CyberKnife M6 System. These include the first such data for the InCise MLC. Simulated detectors include diodes, air-filled microchambers, a synthetic micro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5610

    authors: Francescon P,Kilby W,Noll JM,Masi L,Satariano N,Russo S

    更新日期:2017-02-07 00:00:00

  • Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts.

    abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/003

    authors: Hurkmans C,Knöös T,Nilsson P

    更新日期:1996-08-01 00:00:00

  • The first visualization of chemotherapy-induced tumor apoptosis via magnetic particle imaging in a mouse model.

    abstract::Imaging technologies that allow non-radiative visualization and quantification of apoptosis have a great potential for assessing therapy response, early diagnosis, and disease monitoring. Magnetic particle imaging (MPI), the direct imaging of magnetic nanoparticles as positive contrast agent and sole signal source, en...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abad7c

    authors: Liang X,Wang K,Du J,Tian J,Zhang H

    更新日期:2020-09-24 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • Impedance magnetocardiogram.

    abstract::We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart--the so-called magnetocardiogram (MCG)--can be simultaneously detected by using this system. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/2/403

    authors: Kandori A,Miyashita T,Suzuki D,Yokosawa K,Tsukada K

    更新日期:2001-02-01 00:00:00

  • Regional deep hyperthermia: impact of observer variability in CT-based manual tissue segmentation on simulated temperature distribution.

    abstract::The aim of this study was to systematically investigate the influence of the inter- and intra-observer segmentation variation of tumors and organs at risk on the simulated temperature coverage of the target. CT scans of six patients with tumors in the pelvic region acquired for radiotherapy treatment planning were use...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa685b

    authors: Aklan B,Hartmann J,Zink D,Siavooshhaghighi H,Merten R,Putz F,Ott O,Fietkau R,Bert C

    更新日期:2017-05-08 00:00:00

  • Improved tumour response prediction with equivalent uniform dose in pre-clinical study using direct intratumoural infusion of liposome-encapsulated ¹⁸⁶Re radionuclides.

    abstract::Crucial to all cancer therapy modalities is a strong correlation between treatment and effect. Predictability of therapy success/failure allows for the optimization of treatment protocol and aids in the decision of whether additional treatment is necessary to prevent tumour progression. This work evaluated the relatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/17/016

    authors: Hrycushko BA,Ware S,Li S,Bao A

    更新日期:2011-09-07 00:00:00

  • Ionization chamber volume determination and quality assurance using micro-CT imaging.

    abstract::Ion chamber dosimetry requires a high degree of precision, at all steps within the dosimetric process, in order to ensure accurate dose measurements. This work presents a novel technique for ion chamber volume determination and quality assurance, using micro-computed tomography (micro-CT). Four nominally identical Exr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/18/012

    authors: McNiven AL,Umoh J,Kron T,Holdsworth DW,Battista JJ

    更新日期:2008-09-21 00:00:00

  • A theoretical approach for non-equilibrium radiation dosimetry.

    abstract::This study presents a theoretical approach to the dosimetry for small and non-equilibrium radiation fields. We applied the newly developed VMCBC algorithm to the dosimetry for megavoltage photon beams using Monte Carlo techniques. The approach assumes that a Monte Carlo simulated beam can be calibrated per incident pa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/006

    authors: Ding GX,Duggan DM,Coffey CW

    更新日期:2008-07-07 00:00:00

  • Evaluation of robustness of maximum likelihood cone-beam CT reconstruction with total variation regularization.

    abstract::The objective of this paper is to evaluate an iterative maximum likelihood (ML) cone-beam computed tomography (CBCT) reconstruction with total variation (TV) regularization with respect to the robustness of the algorithm due to data inconsistencies. Three different and (for clinical application) typical classes of err...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5955

    authors: Stsepankou D,Arns A,Ng SK,Zygmanski P,Hesser J

    更新日期:2012-10-07 00:00:00

  • Photon quality correction factors for ionization chambers in an epithermal neutron beam.

    abstract::Photon quality correction factors (kQy) for ionization chamber photon dosimetry in an epithermal neutron beam were determined according to a modified absorbed dose to water formalism which was extended to mixed radiation fields. We have studied two commercially available ionization chambers in the epithermal neutron b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/14/303

    authors: Munck af Rosenschöld PM,Ceberg CP,Giusti V,Andreo P

    更新日期:2002-07-21 00:00:00

  • A high-sensitivity small animal SPECT system.

    abstract::Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) sy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/5/013

    authors: Mitchell GS,Cherry SR

    更新日期:2009-03-07 00:00:00

  • Multi-feature-based plaque characterization in ex vivo MRI trained by registration to 3D histology.

    abstract::We present a new method for automated characterization of atherosclerotic plaque composition in ex vivo MRI. It uses MRI intensities as well as four other types of features: smoothed, gradient magnitude and Laplacian images at several scales, and the distances to the lumen and outer vessel wall. The ground truth for f...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/1/241

    authors: van Engelen A,Niessen WJ,Klein S,Groen HC,Verhagen HJ,Wentzel JJ,van der Lugt A,de Bruijne M

    更新日期:2012-01-07 00:00:00

  • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.

    abstract::Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/N02

    authors: Klüter S,Sroka-Perez G,Schubert K,Debus J

    更新日期:2011-01-21 00:00:00

  • Relative Patlak plot for dynamic PET parametric imaging without the need for early-time input function.

    abstract::The Patlak graphical method is widely used in parametric imaging for modeling irreversible radiotracer kinetics in dynamic PET. The net influx rate of radiotracer can be determined from the slope of the Patlak plot. The implementation of the standard Patlak method requires the knowledge of full-time input function fro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad444

    authors: Zuo Y,Qi J,Wang G

    更新日期:2018-08-10 00:00:00

  • Spectral x-ray imaging: Conditions under which propagation-based phase-contrast is beneficial.

    abstract::Energy-resolved attenuation data in spectral x-ray imaging enables material decomposition, in which the different materials inside an object can be identified and separated virtually. Material decomposition has the drawback of increased noise in the resulting material images relative to the measured images. Recently, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aba318

    authors: Schaff F,Morgan KS,Paganin DM,Kitchen MJ

    更新日期:2020-10-07 00:00:00

  • Cadmium in man measured in vivo by x-ray fluorescence analysis.

    abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/004

    authors: Ahlgren L,Mattsson S

    更新日期:1981-01-01 00:00:00

  • A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements.

    abstract::Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its hea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/22/010

    authors: ten Have AG,Gijsen FJ,Wentzel JJ,Slager CJ,Serruys PW,van der Steen AF

    更新日期:2006-11-21 00:00:00

  • Diagnostic imaging over the last 50 years: research and development in medical imaging science and technology.

    abstract::Over the last 50 years, diagnostic imaging has grown from a state of infancy to a high level of maturity. Many new imaging modalities have been developed. However, modern medical imaging includes not only image production but also image processing, computer-aided diagnosis (CAD), image recording and storage, and image...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R02

    authors: Doi K

    更新日期:2006-07-07 00:00:00

  • Verification of absolute dose rates for intravascular brachytherapy beta sources.

    abstract::The absolute dose rate around beta sources for intravascular brachytherapy was measured with thin thermoluminescent (TL) dosimeters and radiochromic film. The calibration of these dosimeters was performed at the dose maximum in a 6 MeV electron beam of a linear accelerator. Compared to the values given by the manufact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/311

    authors: Piessens M,Reynaert N

    更新日期:2000-08-01 00:00:00

  • Motion induced interplay effects for VMAT radiotherapy.

    abstract::The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab957

    authors: Edvardsson A,Nordström F,Ceberg C,Ceberg S

    更新日期:2018-04-19 00:00:00