Abstract:
:The aim of this study was to systematically investigate the influence of the inter- and intra-observer segmentation variation of tumors and organs at risk on the simulated temperature coverage of the target. CT scans of six patients with tumors in the pelvic region acquired for radiotherapy treatment planning were used for hyperthermia treatment planning. To study the effect of inter-observer variation, three observers manually segmented in the CT images of each patient the following structures: fat, muscle, bone and the bladder. The gross tumor volumes (GTV) were contoured by three radiation oncology residents and used as the hyperthermia target volumes. For intra-observer variation, one of the observers of each group contoured the structures of each patient three times with a time span of one week between the segmentations. Moreover, the impact of segmentation variations in organs at risk (OARs) between the three inter-observers was investigated on simulated temperature distributions using only one GTV. The spatial overlap between individual segmentations was assessed by the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Additionally, the temperatures T90/T10 delivered to 90%/10% of the GTV, respectively, were assessed for each observer combination. The results of the segmentation similarity evaluation showed that the DSC of the inter-observer variation of fat, muscle, the bladder, bone and the target was 0.68 ± 0.12, 0.88 ± 0.05, 0.73 ± 0.14, 0.91 ± 0.04 and 0.64 ± 0.11, respectively. Similar results were found for the intra-observer variation. The MSD results were similar to the DSCs for both observer variations. A statistically significant difference (p < 0.05) was found for T90 and T10 in the predicted target temperature due to the observer variability. The conclusion is that intra- and inter-observer variations have a significant impact on the temperature coverage of the target. Furthermore, OARs, such as bone and the bladder, may essentially influence the homogeneity of the simulated target temperature distribution.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Aklan B,Hartmann J,Zink D,Siavooshhaghighi H,Merten R,Putz F,Ott O,Fietkau R,Bert Cdoi
10.1088/1361-6560/aa685bsubject
Has Abstractpub_date
2017-05-08 00:00:00pages
4479-4495issue
11eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::'Patlak analysis' is a common approach used in Fdopa PET studies to calculate the uptake constant (Ki) of the tracer. It is assumed in the Patlak analysis that the reversible compartment of tissue radioactivity used is in effective equilibrium with the tracer in plasma. Therefore, using the data prior to equilibrium i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/40/7/007
更新日期:1995-07-01 00:00:00
abstract::The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on a whole-body sized, vertical field, 59 mT permanent magnet. Field cycling is accomplished by the field compensation method, and uses a secondary, resistive magn...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/7/008
更新日期:1998-07-01 00:00:00
abstract::Crucial to all cancer therapy modalities is a strong correlation between treatment and effect. Predictability of therapy success/failure allows for the optimization of treatment protocol and aids in the decision of whether additional treatment is necessary to prevent tumour progression. This work evaluated the relatio...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/17/016
更新日期:2011-09-07 00:00:00
abstract::Digital phantoms continue to play a significant role in modeling and characterizing medical imaging. The currently available XCAT phantom incorporates both the flexibility of mathematical phantoms and the realistic nature of voxelized phantoms. This phantom generates images based on a regular breathing pattern and can...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/11/3597
更新日期:2012-06-07 00:00:00
abstract::This paper addresses fundamental issues that underlie the interpretation of images acquired from turbid tissues by optical-coherence tomography (OCT). The attenuation and backscattering properties of freshly excised rat arteries and their dependence on the focusing and collection optics of the OCT system were measured...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/10/013
更新日期:1994-10-01 00:00:00
abstract::Voltage-sensitive dyes are an important tool in visualizing electrical activity in cardiac tissue. Until today, they have mainly been applied in cardiac electrophysiology to subsurface imaging. In the present study, we assess different imaging methods used in optical tomography with respect to their effectiveness in v...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/2/003
更新日期:2005-01-21 00:00:00
abstract::A calibration of the Fricke dosimeter is a measurement of epsilon G(Fe3+). Although G(Fe3+) is expected to be approximately energy independent for all low-LET radiation, existing data are not adequate to rule out the possibility of changes of a few per cent with beam quality. When a high-precision Fricke dosimeter, wh...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/44/7/303
更新日期:1999-07-01 00:00:00
abstract::Although x-ray mammography is widely developed for breast tumour detection, it suffers from spatial superposition in its two-dimensional (2D) representation of a three-dimensional (3D) breast structure. Accordingly, 3D breast imaging, such as cone-beam computed tomography (CT), arises at the historic moment. In this p...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/48/14/312
更新日期:2003-07-21 00:00:00
abstract::Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused b...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aaf96d
更新日期:2019-01-22 00:00:00
abstract::Several direct algorithms have been proposed to take into account the non-linear path of protons in the reconstruction of a proton CT (pCT) image. This paper presents a comparison between five of them, in terms of spatial resolution and relative stopping power (RSP) accuracy. Our comparison includes (1) a distance-dri...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab7d53
更新日期:2020-06-01 00:00:00
abstract::In vitro dielectric properties of ageing porcine tissues were measured in the frequency range of 50 MHz-20 GHz, and the total combined uncertainties of the measurements were assessed. The results show statistically significant reduction with age in both permittivity and conductivity of 10 out of 15 measured tissues. A...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/2/004
更新日期:2009-01-21 00:00:00
abstract::Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/5/013
更新日期:2006-03-07 00:00:00
abstract::We propose a hybrid multiobjective (MO) evolutionary optimization algorithm (MOEA) for intensity-modulated radiotherapy inverse planning and apply it to optimize the number of incident beams, their orientations and intensity profiles. The algorithm produces a set of efficient solutions, which represent different clini...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/5/007
更新日期:2004-03-07 00:00:00
abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/13/4643
更新日期:2013-07-07 00:00:00
abstract::Optical topography is a method for visualization of conical activity. Ways of improving the spatial resolution of the topographical image with three arrangements of optical fibres are discussed. A distribution of sensitivity is obtained from the phantom experiment, and used to reconstruct topographical images of an ac...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/18/311
更新日期:2002-09-21 00:00:00
abstract::A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT) module prototype built to evaluate its performance. The design of the micro-dose calibrator is based on the con...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aadb3b
更新日期:2018-09-10 00:00:00
abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/11/011
更新日期:1993-11-01 00:00:00
abstract::The amount of silica in the human lung may be estimated by measurement of silicon using in vivo neutron activation analysis. A pulsed, fast neutron beam, produced with a 2 MV Van de Graaff generator using the 2H + 2H reaction, was used to irradiate a Si-doped chest phantom in order to determine minimum detection limit...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/6/004
更新日期:1993-06-01 00:00:00
abstract::A new thin-target method (patent pending) is described for portal imaging with low-energy (tens of keV) photons from a medical linear accelerator operating in a special mode. Low-energy photons are usually produced in the accelerator target, but are absorbed by the target and flattening filter, both made of medium- or...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/8/016
更新日期:1998-08-01 00:00:00
abstract::We describe an improved algorithm for localising equivalent sources of biomagnetic fields in the human brain. The algorithm is an improvement over the sphere model in that it considers two distinct surfaces: an ellipsoid, to model the region of the skull on which the sensors are placed, and a sphere as the medium in w...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/32/1/017
更新日期:1987-01-01 00:00:00
abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8bf3
更新日期:2020-06-15 00:00:00
abstract::Megavoltage (MV) cone-beam computed tomography (CBCT) using an electronic portal imaging (EPID) offers advantageous features, including 3D mapping, treatment beam registration, high-z artifact suppression, and direct radiation dose calculation. Adoption has been slowed by image quality limitations and concerns about i...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac8c6
更新日期:2018-06-20 00:00:00
abstract::Positron emission tomography (PET) has become an important modality in medical and molecular imaging. However, in most PET applications, the resolution is still mainly limited by the physical crystal sizes or the detector's intrinsic spatial resolution. To achieve images with better spatial resolution in a central reg...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/2/647
更新日期:2015-01-21 00:00:00
abstract::The poor agreement in the photon calibrations of tissue-equivalent ionisation chambers between different participants in two major neutron dosimetry intercomparisons is noted. The methods of converting measurements made with a calibrated secondary standard exposure meter to the absorbed dose in the wall of a tissue-eq...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/25/2/002
更新日期:1980-03-01 00:00:00
abstract::The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/12/4412
更新日期:2016-06-21 00:00:00
abstract::It is a challenging problem to resolve and identify drug (or non-specific fluorophore) distribution throughout the whole body of small animals in vivo. In this article, an algorithm of unmixing multispectral fluorescence tomography (MFT) images based on independent component analysis (ICA) is proposed to solve this pr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/17/5025
更新日期:2014-09-07 00:00:00
abstract::For medical applications of ultrasound inside the brain, it is necessary to understand the relationship between the apparent density of skull bone and its corresponding speed of sound and attenuation coefficient. Although there have been previous studies exploring this phenomenon, there is still a need to extend the m...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/1/014
更新日期:2011-01-07 00:00:00
abstract::Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotr...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aadc88
更新日期:2018-09-19 00:00:00
abstract::The values of the replacement correction factors (P(repl), or in the IAEA's notation p(dis)p(cav)) used for cylindrical chambers in high-energy photon beams represent one of the most significant differences between the AAPM and the IAEA dosimetry protocols. In a previous study (Wang L L W and Rogers D W O 2008 Med. Ph...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/6/014
更新日期:2009-03-21 00:00:00
abstract::Dosimetry of proton beams is generally evaluated in liquid water, or alternatively in solid phantoms via water equivalent ratios (WER). WER is defined as the ratio of proton range in liquid water to that in a phantom of certain material. Presently, WER is not available in the literature neither for a wide range of ene...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aad0bd
更新日期:2018-07-27 00:00:00