Abstract:
:It is a challenging problem to resolve and identify drug (or non-specific fluorophore) distribution throughout the whole body of small animals in vivo. In this article, an algorithm of unmixing multispectral fluorescence tomography (MFT) images based on independent component analysis (ICA) is proposed to solve this problem. ICA is used to unmix the data matrix assembled by the reconstruction results from MFT. Then the independent components (ICs) that represent spatial structures and the corresponding spectrum courses (SCs) which are associated with spectral variations can be obtained. By combining the ICs with SCs, the recovered MFT images can be generated and fluorophore concentration can be calculated. Simulation studies, phantom experiments and animal experiments with different concentration contrasts and spectrum combinations are performed to test the performance of the proposed algorithm. Results demonstrate that the proposed algorithm can not only provide the spatial information of fluorophores, but also recover the actual reconstruction of MFT images.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Pu H,Zhang G,He W,Liu F,Guang H,Zhang Y,Bai J,Luo Jdoi
10.1088/0031-9155/59/17/5025subject
Has Abstractpub_date
2014-09-07 00:00:00pages
5025-42issue
17eissn
0031-9155issn
1361-6560journal_volume
59pub_type
杂志文章abstract::In vitro dielectric properties of ageing porcine tissues were measured in the frequency range of 50 MHz-20 GHz, and the total combined uncertainties of the measurements were assessed. The results show statistically significant reduction with age in both permittivity and conductivity of 10 out of 15 measured tissues. A...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/2/004
更新日期:2009-01-21 00:00:00
abstract::The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab9501
更新日期:2020-10-07 00:00:00
abstract::Proton computed tomography (pCT) promises to reduce or even eliminate range uncertainties inherent in the conversion of Hounsfield units into relative stopping power (RSP) for proton therapy treatment planning. This is of particular interest for proton irradiation studies in animal models due to the high precision req...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8afc
更新日期:2020-08-13 00:00:00
abstract::Elevated interstitial fluid pressure is one of the barriers of drug delivery in solid tumors. Recent studies have shown that normalization of tumor vasculature by anti-angiogenic factors may improve the delivery of conventional cytotoxic drugs, possibly by increasing blood flow, decreasing interstitial fluid pressure,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/4/1477
更新日期:2015-02-21 00:00:00
abstract::Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/12/3759
更新日期:2012-06-21 00:00:00
abstract::Monte Carlo calculations of the energy response of LiF dosemeters have been carried out to help resolve the discrepancy between the measurements of Holt, Edelstein and Clark (1975) and those of Paliwal and Almond (1975) and others. It is concluded that the assumptions used by Holt et al. are largely responsible. They ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/22/5/003
更新日期:1977-09-01 00:00:00
abstract::Radiotherapy calculations often involve complex geometries such as interfaces between materials of vastly differing atomic number, such as lung, bone and/or air interfaces. Monte Carlo methods have been used to calculate accurately the perturbation effects of the interfaces. However, these methods can be computational...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/51/9/010
更新日期:2006-05-07 00:00:00
abstract::Respiratory-correlated cone-beam CT (CBCT) not only inhibits rapid scanning due to the slow speed of the LINAC head gantry rotation, but its implementation for routine patient imaging is impractical because of the high radiation dose delivered during the process. Digital tomosynthesis (DTS) is a potentially faster tec...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab0d50
更新日期:2019-05-02 00:00:00
abstract::The free space method using a pair of lens antennas was modified for the complex permittivity measurement of biological samples from 20 to 110 GHz. Two methodologies were used to obtain the complex permittivities by the free space method, which were based on the reflection and transmission coefficients. The measuremen...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/5/1625
更新日期:2013-03-07 00:00:00
abstract::A method will be described for determining the centre of rotation of a mechanically scanned reflection ultrasound computed tomography system. It is based on the principle of obtaining opposing images of a test object containing many point targets. The method is automatic in the sense that the centre of rotation is cal...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/39/12/017
更新日期:1994-12-01 00:00:00
abstract::The temperature sensitivities of absorption and reduced scattering coefficients in the range 700-1000 nm are determined for the liquid phantom Intralipid using spatially resolved continuous wave measurements. The measurements were conducted on a 10 L heated volume of 1% Intralipid subjected to a 40-30 degrees C coolin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/9/003
更新日期:2007-05-07 00:00:00
abstract::Experimental radiobiological investigations of fast neutron beams involve irradiation of thin cell layers. The irradiation of cells is done either in free air or with a material such as graphite, TE plastic or bone-equivalent plastic covering the cells. This paper discusses the computed dose distributions in LET at sh...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/24/5/007
更新日期:1979-09-01 00:00:00
abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/6/1685
更新日期:2012-03-21 00:00:00
abstract::Cone-beam computed tomography (CBCT) has been clinically used to verify patient position and to localize the target of treatment in image-guided radiation therapy (IGRT). However, when the chest and the upper abdomen are scanned, respiratory-induced motion blurring limits the utility of CBCT. In order to mitigate this...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/20/006
更新日期:2008-10-21 00:00:00
abstract::Contrast enhanced ultrasound (CEUS) and dynamic contrast enhanced ultrasound (DCE-US) can be used to provide information about the vasculature aiding diagnosis and monitoring of a number of pathologies including cancer. In the development of a CEUS imaging system, there are many choices to be made, such as whether to ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab13f2
更新日期:2019-04-23 00:00:00
abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/15/5853
更新日期:2015-08-07 00:00:00
abstract::The analysis of (x-ray) mammograms remains qualitative, relying on the judgement of clinicians. We present a novel method to compute a quantitative, normalized measure of tissue radiodensity traversed by the primary beam incident on each pixel of a mammogram, a measure we term the standard attenuation rate (SAR). SAR ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/20/6519
更新日期:2012-10-21 00:00:00
abstract::There are three ways to determine the spectrum of a clinical photon beam: direct measurement, modelling the source and reconstruction from ion-chamber measurements. We focus on reconstruction because the necessary equipment is readily available and it provides independent confirmation of source models for a given mach...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/49/22/005
更新日期:2004-11-21 00:00:00
abstract::To calculate photon spectra for a 10 MV x-ray beam emitted by a medical linear accelerator, we performed numerical analysis using the aluminium transmission data obtained along the central axis of the beam under the narrow beam condition corresponding to a 3x3 cm2 field at a 100 cm distance from the source. We used th...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/2/014
更新日期:2007-01-21 00:00:00
abstract::Magnetic resonance-guided radiation therapy (MR-GRT) offers great potential to improve radiation treatment outcomes by providing more accurate and patient-tailored therapy. Despite superior soft tissue contrast in MRI, one of the challenges towards MRI-only workflows is that the process often requires some sort of 'MR...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab2623
更新日期:2019-07-16 00:00:00
abstract::Investigate 3D (spatial and temporal) convolutional neural networks (CNNs) for real-time on-the-fly magnetic resonance imaging (MRI) reconstruction. In particular, we investigated the applicability of training CNNs on a patient-by-patient basis for the purpose of lung tumor segmentation. Data were acquired with our 3 ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab408e
更新日期:2019-09-23 00:00:00
abstract::A special parallel-plate ionization chamber was developed. The motivation for the construction of this new chamber was mainly to fulfil the need of a reference system for computed tomography standard beams in the Calibration Laboratory of IPEN. However, the chamber was tested also in standard radiation beams of mammog...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/16/012
更新日期:2005-08-21 00:00:00
abstract::This paper presents a computer simulation of photon interaction with collimator septa, which allows the point spread function of scintillation camera collimators to be calculated. The method simulates photon attenuation along their propagation direction in a determinist way. Using this simulation, the spatial resoluti...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/35/5/006
更新日期:1990-05-01 00:00:00
abstract::An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/56/20/007
更新日期:2011-10-21 00:00:00
abstract::This study presents a theoretical approach to the dosimetry for small and non-equilibrium radiation fields. We applied the newly developed VMCBC algorithm to the dosimetry for megavoltage photon beams using Monte Carlo techniques. The approach assumes that a Monte Carlo simulated beam can be calibrated per incident pa...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/13/006
更新日期:2008-07-07 00:00:00
abstract::Several papers have recently addressed the issue of estimating chromophore concentration in optoacoustic imaging (OAI) using multiple wavelengths. The choice of wavelengths obviously affects the accuracy and precision of the estimates. One might assume that the wavelengths that maximize the extinction coefficients of ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/55/23/004
更新日期:2010-12-07 00:00:00
abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/1/004
更新日期:2009-01-07 00:00:00
abstract::The electrostimulation excitation threshold of a nerve depends on temporal and frequency parameters of the stimulus. These dependences were investigated in terms of: (1) strength-duration (SD) curve for a single monophasic rectangular pulse, and (2) frequency dependence of the excitation threshold for a continuous sin...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/12/4364
更新日期:2016-06-21 00:00:00
abstract::This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel pha...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/6/2582
更新日期:2016-03-21 00:00:00
abstract::Various forms of GAFChromic film have been used for several years as radiographic media for measuring dose distributions of brachytherapy sources and small radiation fields. Upon irradiation the film changes colour and darkens with time post-irradiation. The darkening is most rapid in the first 24 h, and it has been s...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/43/10/001
更新日期:1998-10-01 00:00:00