Abstract:
:Lung 4D computed tomography (4D-CT), which is a time-resolved CT data acquisition, performs an important role in explicitly including respiratory motion in treatment planning and delivery. However, the radiation dose is usually reduced at the expense of inter-slice spatial resolution to minimize radiation-related health risk. Therefore, resolution enhancement along the superior-inferior direction is necessary. In this paper, a super-resolution (SR) reconstruction method based on a patch low-rank matrix reconstruction is proposed to improve the resolution of lung 4D-CT images. Specifically, a low-rank matrix related to every patch is constructed by using a patch searching strategy. Thereafter, the singular value shrinkage is employed to recover the high-resolution patch under the constraints of the image degradation model. The output high-resolution patches are finally assembled to output the entire image. This method is extensively evaluated using two public data sets. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 9.7%-33.4% and the edge width by 11.4%-24.3%, relative to linear interpolation, back projection (BP) and Zhang et al's algorithm. A new algorithm has been developed to improve the resolution of 4D-CT. In all experiments, the proposed method outperforms various interpolation methods, as well as BP and Zhang et al's method, thus indicating the effectivity and competitiveness of the proposed algorithm.
journal_name
Phys Med Bioljournal_title
Physics in medicine and biologyauthors
Fang S,Wang H,Liu Y,Zhang M,Yang W,Feng Q,Chen W,Zhang Ydoi
10.1088/1361-6560/aa8a48subject
Has Abstractpub_date
2017-10-03 00:00:00pages
7925-7937issue
20eissn
0031-9155issn
1361-6560journal_volume
62pub_type
杂志文章abstract::The dosimetrical characteristics of a new miniature multileaf collimator (ModuLeaf MLC, MRC Systems GmbH, Heidelberg, Germany) attached to the accessory holder of a Siemens accelerator with 6 MV x-rays (PRIMUS, Siemens OCS, Concord, California, USA) have been investigated. In particular, those parameters which are imp...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/47/12/402
更新日期:2002-06-21 00:00:00
abstract::The purpose of this study is to evaluate a new method to improve performance of computer-aided detection (CAD) schemes of screening mammograms with two approaches. In the first approach, we developed a new case based CAD scheme using a set of optimally selected global mammographic density, texture, spiculation, and st...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aa5081
更新日期:2017-01-21 00:00:00
abstract::Brain stereotactic radiosurgery (SRS) treatments require multiple quality assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear accelerator is crucial. In this study, a novel...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab8534
更新日期:2020-06-10 00:00:00
abstract::Due to high noise levels in the voxel kinetics, development of reliable parametric imaging algorithms remains one of most active areas in dynamic brain PET imaging, which in the vast majority of cases involves receptor/transporter studies with reversibly binding tracers. As such, the focus of this work has been to dev...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/3/733
更新日期:2012-02-07 00:00:00
abstract::In this study, we evaluate the feasibility of designing a beveled fiber-optic probe coupled with a ball lens for improving depth-resolved fluorescence measurements of epithelial tissue using Monte Carlo (MC) simulations. The results show that by using the probe configuration with a beveled tip collection fiber and a f...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/4/008
更新日期:2008-02-21 00:00:00
abstract::We are developing a dedicated, combined breast positron emission tomography (PET)-tomosynthesis scanner. Both the PET and digital breast tomosynthesis (DBT) scanners are integrated in a single gantry to provide spatially co-registered 3D PET-tomosynthesis images. The DBT image will be used to identify the breast bound...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/abc5a8
更新日期:2020-10-28 00:00:00
abstract::At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/59/7/1845
更新日期:2014-04-07 00:00:00
abstract::The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as inte...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/50/18/N02
更新日期:2005-09-21 00:00:00
abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/34/10/003
更新日期:1989-10-01 00:00:00
abstract::Kilo-voltage (KV) cone-beam computed tomography (CBCT) unit mounted onto a linear accelerator treatment system, often referred to as on-board imager (OBI), plays an increasingly important role in image-guided radiation therapy. While the FDK algorithm is currently used for reconstructing images from clinical OBI data,...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/60/12/4601
更新日期:2015-06-21 00:00:00
abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/10/002
更新日期:2009-05-21 00:00:00
abstract::This is a review of the relatively recently developed field of intravascular brachytherapy of coronary arteries. It presents a brief overview of the discipline of coronary angioplasty describing the problem of restenosis and discusses the potential for ionizing radiation to overcome this problem. It examines the vario...
journal_title:Physics in medicine and biology
pub_type: 杂志文章,评审
doi:10.1088/0031-9155/47/4/201
更新日期:2002-02-21 00:00:00
abstract::Magnetic resonance and ultrasound elastography techniques are now important tools for staging high-grade fibrosis in patients with chronic liver disease. However, uncertainty remains about the effects of simple accumulation of fat (steatosis) and inflammation (steatohepatitis) on the parameters that can be measured us...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/aac09a
更新日期:2018-05-17 00:00:00
abstract::Uncemented prosthetic joint implants used in orthopaedic surgery are usually coated with a porous surface to encourage bone ingrowth. Better contact between the endosteal bone and the porous surface improves ingrowth, and such contact may be increased if the joint further subsides into position in the first weeks foll...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/2/009
更新日期:1993-02-01 00:00:00
abstract::In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab3fcd
更新日期:2019-10-23 00:00:00
abstract::Optical computed tomography (optical-CT) of 3D radiation dosimeters is a promising avenue for delivering an economic and reliable quality control of radiotherapy treatments such as intensity modulated radiotherapy, brachytherapy and stereotactic radiosurgery. The main problems in transferring 3D dosimeters to clinical...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/11/N01
更新日期:2007-06-07 00:00:00
abstract::Monte Carlo simulations are used to investigate skin dose resulting from chest wall radiotherapy with bolus. A simple model of a female thorax is developed, which includes a 2 mm-thick skin layer. Two representative 6 MV source models are considered: a tangents source model consisting of a parallel opposed pair of med...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/ab95dc
更新日期:2020-08-11 00:00:00
abstract::Droplets of liquid perfluorocarbon (PFC) are under study as the next generation of contrast agents for ultrasound (US). These droplets can be selectively vaporized into echogenic gas bubbles in situ by externally applied US, with numerous applications to diagnosis and therapy. However, little is known about the mechan...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/21/7205
更新日期:2012-11-07 00:00:00
abstract::This work investigates the attenuation of a proton beam to reconstruct the map of the linear attenuation coefficient of a material which is mainly caused by the inelastic interactions of protons with matter. Attenuation proton computed tomography (pCT) suffers from a poor spatial resolution due to multiple Coulomb sca...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/61/9/3258
更新日期:2016-05-07 00:00:00
abstract::In clinical computed tomography (CT) images, cortical bone features with sub-millimeter (sub-mm) thickness are substantially blurred, such that their thickness is overestimated and their intensity appears underestimated. Therefore, any inquiry of the geometry or the density of such bones based on these images is sever...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/23/8099
更新日期:2012-12-07 00:00:00
abstract::Four dimensional cone beam computed tomography (4DCBCT) uses a constant gantry speed and imaging frequency that are independent of the patient's breathing rate. Using a technique called respiratory motion guided 4DCBCT (RMG-4DCBCT), we have previously demonstrated that by varying the gantry speed and imaging frequency...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/1361-6560/62/11/4300
更新日期:2017-06-07 00:00:00
abstract::Protons and carbon ion beams for hadron therapy can be delivered by cyclotrons with a fixed energy. In order to treat patients, an energy degrader along the beam line will be used to match the particle range with the target depth. Fragmentation reactions of carbon ions inside the degrader material could introduce a sm...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/53/21/010
更新日期:2008-11-07 00:00:00
abstract::The significance of accurate knowledge of background optical properties and time-resolved information in reconstructing images of hemodynamic changes in the neonatal brain from diffuse optical imaging data was studied using Monte Carlo (MC) simulation. A segmented anatomical magnetic resonance (MR) image and literatur...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/54/3/005
更新日期:2009-02-07 00:00:00
abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/58/22/7905
更新日期:2013-11-21 00:00:00
abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/57/14/4683
更新日期:2012-07-21 00:00:00
abstract::The aim of this study is to investigate the use of mathematical morphology for the determination of left ventricular contours in scintigraphic images using multigated radionuclide angiography. We have developed a completely automatic method that first restores the image with a Wiener filter, then finds the region wher...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/38/12/012
更新日期:1993-12-01 00:00:00
abstract::The purpose of this work was to use Monte Carlo simulations to verify the accuracy of the dose distributions from a commercial treatment planning optimization system (Corvus, Nomos Corp., Sewickley, PA) for intensity-modulated radiotherapy (IMRT). A Monte Carlo treatment planning system has been implemented clinically...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/45/9/303
更新日期:2000-09-01 00:00:00
abstract::A method is described which offers an alternative to conventional Fourier phase/amplitude imaging for analysing representative LV cycles obtained from first-pass cardiac studies. The method involves applying factor analysis to the data and producing functional images of the first two factor loadings after polar transf...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/27/10/007
更新日期:1982-10-01 00:00:00
abstract::Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumou...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/36/11/009
更新日期:1991-11-01 00:00:00
abstract::Acidic drinks and foodstuffs can demineralize dental hard tissues, leading to a pathological condition known as dental erosion, which is of increasing clinical concern. The first step in enamel dissolution is a demineralization of the outer few micrometres of tissue, which results in a softening of the structure. The ...
journal_title:Physics in medicine and biology
pub_type: 杂志文章
doi:10.1088/0031-9155/52/4/003
更新日期:2007-02-21 00:00:00