Direct 4D parametric imaging for linearized models of reversibly binding PET tracers using generalized AB-EM reconstruction.

Abstract:

:Due to high noise levels in the voxel kinetics, development of reliable parametric imaging algorithms remains one of most active areas in dynamic brain PET imaging, which in the vast majority of cases involves receptor/transporter studies with reversibly binding tracers. As such, the focus of this work has been to develop a novel direct 4D parametric image reconstruction scheme for such tracers. Based on a relative equilibrium (RE) graphical analysis formulation (Zhou et al 2009b Neuroimage 44 661-70), we developed a closed-form 4D EM algorithm to directly reconstruct distribution volume (DV) parametric images within a plasma input model, as well as DV ratio (DVR) images within a reference tissue model scheme (wherein an initial reconstruction was used to estimate the reference tissue time-activity curves). A particular challenge with the direct 4D EM formulation is that the intercept parameters in graphical (linearized) analysis of reversible tracers (e.g. Logan or RE analysis) are commonly negative (unlike for irreversible tracers, e.g. using Patlak analysis). Subsequently, we focused our attention on the AB-EM algorithm, derived by Byrne (1998, Inverse Problems 14 1455-67) to allow inclusion of prior information about the lower (A) and upper (B) bounds for image values. We then generalized this algorithm to the 4D EM framework, thus allowing negative intercept parameters. Furthermore, our 4D AB-EM algorithm incorporated and emphasized the use of spatially varying lower bounds to achieve enhanced performance. As validation, the means of parameters estimated from 55 human (11)C-raclopride dynamic PET studies were used for extensive simulations using a mathematical brain phantom. Images were reconstructed using conventional indirect as well as proposed direct parametric imaging methods. Noise versus bias quantitative measurements were performed in various regions of the brain. Direct 4D EM reconstruction resulted in notable qualitative and quantitative accuracy improvements (over 35% noise reduction, with matched bias, in both plasma and reference-tissue input models). Similar improvements were also observed in the coefficient of variation of the estimated DV and DVR values even for relatively low uptake cortical regions, suggesting the enhanced ability for robust parameter estimation. The method was also tested on a 90 min (11)C-raclopride patient study performed on the high-resolution research tomograph wherein the proposed method was shown across a variety of regions to outperform the conventional method in the sense that for a given DVR value, improved noise levels were observed.

journal_name

Phys Med Biol

authors

Rahmim A,Zhou Y,Tang J,Lu L,Sossi V,Wong DF

doi

10.1088/0031-9155/57/3/733

subject

Has Abstract

pub_date

2012-02-07 00:00:00

pages

733-55

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

57

pub_type

杂志文章
  • Evaluation of factors to convert absorbed dose calibrations from graphite to water for the NPL high-energy photon calibration service.

    abstract::The National Physical Laboratory (NPL) provides a high-energy photon calibration service using 4-19 MV x-rays and 60Co gamma-radiation for secondary standard dosemeters in terms of absorbed dose to water. The primary standard used for this service is a graphite calorimeter and so absorbed dose calibrations must be con...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/3/306

    authors: Nutbrown RF,Duane S,Shipley DR,Thomas RA

    更新日期:2002-02-07 00:00:00

  • An expression for backscatter factors for orthovoltage x-rays.

    abstract::Backscatter factors for orthovoltage x-ray beams are fitted with the expression BSF = 1 + ms/(s + n), where s is field size and m and n are adjustable parameters. The accuracy is better than 0.5%. Good results were also obtained for Cs-137 gamma rays at depth 0.12 cm and Co-60 gamma rays at depth 0.5 cm using the same...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/5/021

    authors: Xiao Y,Bjärngard B

    更新日期:1998-05-01 00:00:00

  • PBS machine interlocks using EWMA.

    abstract::Delivery of pencil beam scanning (PBS) requires the on-line measurement of several beam parameters. If the measurement is outside of specified tolerances and a binary threshold algorithm is used, the beam will be paused. Given instrumentation and statistical noise such a system can lead to many pauses which could incr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/1/400

    authors: Clasie BM,Kooy HM,Flanz JB

    更新日期:2016-01-07 00:00:00

  • A multiresolution image based approach for correction of partial volume effects in emission tomography.

    abstract::Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography. They lead to a loss of signal in tissues of size similar to the point spread function and induce activity spillover between regions. Although PVE can be corrected for by using algorithms that provide the correct ra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/016

    authors: Boussion N,Hatt M,Lamare F,Bizais Y,Turzo A,Cheze-Le Rest C,Visvikis D

    更新日期:2006-04-07 00:00:00

  • A comparison of rotation- and blob-based system models for 3D SPECT with depth-dependent detector response.

    abstract::We compare two different implementations of a 3D SPECT system model for iterative reconstruction, both of which compensate for non-uniform photon attenuation and depth-dependent system response. One implementation performs fast rotation of images represented using a basis of rectangular voxels, whereas the other repre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/11/003

    authors: Yendiki A,Fessler JA

    更新日期:2004-06-07 00:00:00

  • Glandular dose in breast computed tomography with synchrotron radiation.

    abstract::The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/2/569

    authors: Mettivier G,Fedon C,Di Lillo F,Longo R,Sarno A,Tromba G,Russo P

    更新日期:2016-01-21 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

    abstract::Fluorescence molecular tomography (FMT) is widely used in preclinical oncology research. FMT is the only imaging technique able to provide 3D distribution of fluorescent probes within thick highly scattering media. However, its integration into clinical medicine has been hampered by its low spatial resolution caused b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf96d

    authors: Nouizi F,Kwong TC,Ruiz J,Cho J,Chan YW,Ikemura K,Erkol H,Sampathkumaran U,Gulsen G

    更新日期:2019-01-22 00:00:00

  • Quantitative x-ray dark-field computed tomography.

    abstract::The basic principles of x-ray image formation in radiology have remained essentially unchanged since Röntgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/017

    authors: Bech M,Bunk O,Donath T,Feidenhans'l R,David C,Pfeiffer F

    更新日期:2010-09-21 00:00:00

  • Evaluation of a novel triple-channel radiochromic film analysis procedure using EBT2.

    abstract::A novel approach to read out radiochromic film was introduced recently by the manufacturer of GafChromic film. In this study, the performance of this triple-channel film dosimetry method was compared against the conventional single-red-channel film dosimetry procedure, with and without inclusion of a pre-irradiation (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4353

    authors: van Hoof SJ,Granton PV,Landry G,Podesta M,Verhaegen F

    更新日期:2012-07-07 00:00:00

  • Inverse treatment planning for an electronic brachytherapy system delivering anisotropic radiation therapy.

    abstract::An inverse radiation treatment planning algorithm for Sensus Healthcare's SculpturaTM electronic brachytherapy system has been designed. The algorithm makes use of simulated annealing to optimize the conformation number of the treatment plan. The highly anisotropic dose distributions produced by the SculpturaTM x-ray ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abda9a

    authors: Badali DS,Vainer Y,Ellenor CW,Mitchell CR,Fishman K,Soro N,Price R,Funk T

    更新日期:2021-01-11 00:00:00

  • Precision estimation and imaging of normal and shear components of the 3D strain tensor in elastography.

    abstract::In elastography we have previously developed a tracking and correction method that estimates the axial and lateral strain components along and perpendicular to the compressor/scanning axis following an externally applied compression. However, the resulting motion is a three-dimensional problem. Therefore, in order to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/6/311

    authors: Konofagou EE,Ophir J

    更新日期:2000-06-01 00:00:00

  • A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reports.

    abstract::Although interventional x-ray angiography (XA) procedures involve relatively high radiation doses that can lead to deterministic tissue reactions in addition to stochastic effects, convenient and accurate estimation of absorbed organ doses has traditionally been out of reach. This has mainly been due to the absence of...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/8/3063

    authors: Omar A,Bujila R,Fransson A,Andreo P,Poludniowski G

    更新日期:2016-04-21 00:00:00

  • Phase contrast image guidance for synchrotron microbeam radiotherapy.

    abstract::Recent image guidance developments for preclinical synchrotron microbeam radiotherapy represent a necessary step for future clinical translation of the technique. Image quality can be further improved using x-ray phase contrast, which is readily available at synchrotron facilities. We here describe a methodology for p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/16/5942

    authors: Pelliccia D,Crosbie JC,Larkin KG

    更新日期:2016-08-21 00:00:00

  • Radionuclides and carrier molecules for therapy.

    abstract::Although radionuclide therapy has been around for a long time, this modality of cancer treatment has been limited mainly to the use of [32P]-phosphate and [131I]-sodium iodide. The last few years, however, have seen an increased interest in this area due to new developments of radionuclides and carrier molecules that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/41/10/004

    authors: Zweit J

    更新日期:1996-10-01 00:00:00

  • The effective attenuation coefficient of soft tissue in the presence of Compton scattering from bone: experiments on models.

    abstract::Calibration methods are investigated for the determination of bone density by the Compton scattering method. The scattered radiation from materials of different densities and dimensions is measured for this purpose. A function for the dependence of the intensity on these parameters is derived and compared with the exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/4/009

    authors: Leichter I,Weinreb A,Hazan G

    更新日期:1980-07-01 00:00:00

  • Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer.

    abstract::Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for 'densities-of-the-day' was created: (1)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5c12

    authors: Jagt T,Breedveld S,van de Water S,Heijmen B,Hoogeman M

    更新日期:2017-06-07 00:00:00

  • The use of a realistic VMAT delivery emulator to optimize dynamic machine parameters for improved treatment efficiency.

    abstract::The delivery of volumetric modulated arc therapy (VMAT) requires the simultaneous movement of the linear accelerator gantry, multi-leaf collimators and jaws while the dose rate is varied. In this study, a VMAT delivery emulator was developed to accurately predict the characteristics of a given treatment plan, incorpor...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/024

    authors: Boylan CJ,Rowbottom CG,Mackay RI

    更新日期:2011-07-07 00:00:00

  • Influence of the surface averaging procedure of the current density in assessing compliance with the ICNIRP low-frequency basic restrictions by means of numerical techniques.

    abstract::Although the calculation of the surface average of the low-frequency current density distribution over a cross-section of 1 cm2 is required by ICNIRP guidelines, no reference averaging algorithm is indicated, neither in the ICNIRP guidelines nor in the Directive 2004/40/EC that is based on them. The lack of a general ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/013

    authors: Zoppetti N,Andreuccetti D

    更新日期:2009-08-07 00:00:00

  • Iterative reconstruction of SiPM light response functions in a square-shaped compact gamma camera.

    abstract::Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and radiotracer guided surgery. Statistical methods of position reconstruction, which are p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6029

    authors: Morozov A,Alves F,Marcos J,Martins R,Pereira L,Solovov V,Chepel V

    更新日期:2017-05-07 00:00:00

  • Imputing radiobiological parameters of the linear-quadratic dose-response model from a radiotherapy fractionation plan.

    abstract::The objective in cancer radiotherapy is to maximize tumor-kill while limiting toxic effects of radiation dose on nearby organs-at-risk (OAR). Given a fixed number of treatment sessions, planners thus face the problem of finding a dosing sequence that achieves this goal. This is called the fractionation problem, and ha...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abb935

    authors: Ghate A

    更新日期:2020-09-16 00:00:00

  • A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values.

    abstract::The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/62/5/N90

    authors: Tajik-Mansoury MA,Rajabi H,Mozdarani H

    更新日期:2017-03-07 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

    abstract::The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/16/306

    authors: Jarry G,DeMarco JJ,Beifuss U,Cagnon CH,McNitt-Gray MF

    更新日期:2003-08-21 00:00:00

  • Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies.

    abstract::Effective use of the [Formula: see text] decay chain in targeted internal radioimmunotherapy requires the retention of both [Formula: see text] and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa6a99

    authors: Robertson AKH,Ramogida CF,Rodríguez-Rodríguez C,Blinder S,Kunz P,Sossi V,Schaffer P

    更新日期:2017-06-07 00:00:00

  • The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies.

    abstract::'Patlak analysis' is a common approach used in Fdopa PET studies to calculate the uptake constant (Ki) of the tracer. It is assumed in the Patlak analysis that the reversible compartment of tissue radioactivity used is in effective equilibrium with the tracer in plasma. Therefore, using the data prior to equilibrium i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/7/007

    authors: Yu DC,Huang SC,Barrio JR,Phelps ME

    更新日期:1995-07-01 00:00:00

  • Development and comparison of computer methods for organ motion correction in scintigraphy.

    abstract::The process of organ motion correction in scintigraphy is analysed in the frequency domain. The sequence of the chi- and gamma- coordinates registered during scintigraphic recording is converted to a frequency spectrum by a discrete Fourier transform. In the frequency domain motion correction is performed by linear fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/3/010

    authors: Schmidlin P

    更新日期:1975-05-01 00:00:00

  • Experimental validation of the DPM Monte Carlo code using minimally scattered electron beams in heterogeneous media.

    abstract::A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/11/301

    authors: Chetty IJ,Moran JM,Nurushev TS,McShan DL,Fraass BA,Wilderman SJ,Bielajew AF

    更新日期:2002-06-07 00:00:00

  • The Fokker-Planck equation for coupled Brown-Néel-rotation.

    abstract::Calculating the dynamic properties of magnetization of single-domain particles is of great importance for the tomographic imaging modality known as magnetic particle imaging (MPI). Although the assumption of instantaneous thermodynamic equilibrium (Langevin function) after application of time-dependent magnetic fields...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa186

    authors: Weizenecker J

    更新日期:2018-01-22 00:00:00

  • Estimating photon interaction coefficients from single energy x-ray CT.

    abstract::Single energy x-ray analysis is explored in the context of computed tomography (CT), whereby Hounsfield numbers (HN) are used to estimate electron density N(e) and parameters that describe composition. We examine measurements with tissue substitute materials and theoretical HN for a broad range of tissues. Results are...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/23/8079

    authors: Midgley SM

    更新日期:2012-12-07 00:00:00