Quantitative x-ray dark-field computed tomography.

Abstract:

:The basic principles of x-ray image formation in radiology have remained essentially unchanged since Röntgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpret image formation. Phase-contrast or coherent scatter imaging techniques, which can be understood using wave optics rather than ray optics, offer ways to augment or complement the conventional approach by incorporating the wave-optical interaction of x-rays with the specimen. With a recently developed approach based on x-ray optical gratings, advanced phase-contrast and dark-field scatter imaging modalities are now in reach for routine medical imaging and non-destructive testing applications. To quantitatively assess the new potential of particularly the grating-based dark-field imaging modality, we here introduce a mathematical formalism together with a material-dependent parameter, the so-called linear diffusion coefficient and show that this description can yield quantitative dark-field computed tomography (QDFCT) images of experimental test phantoms.

journal_name

Phys Med Biol

authors

Bech M,Bunk O,Donath T,Feidenhans'l R,David C,Pfeiffer F

doi

10.1088/0031-9155/55/18/017

subject

Has Abstract

pub_date

2010-09-21 00:00:00

pages

5529-39

issue

18

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(10)54778-X

journal_volume

55

pub_type

杂志文章
  • Comparison of two-compartment exchange and continuum models of dMRI in skeletal muscle.

    abstract::Clinical diffusion MRI (dMRI) is sensitive to micrometer scale spin displacements, but the image resolution is  ∼mm, so the biophysical interpretation of the signal relies on establishing appropriate subvoxel tissue models. A class of two-compartment exchange models originally proposed by Kärger have been used success...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2aa6

    authors: Naughton NM,Georgiadis JG

    更新日期:2019-08-01 00:00:00

  • A depth-encoding PET detector for high resolution PET using 1 mm SiPMs.

    abstract::A dual-ended readout PET detector based on two Hamamatsu 16 × 16 arrays of 1 × 1 mm2 SiPMs coupled to both ends of a 25 × 25 array of 0.69 × 0.69 × 20 mm3 polished LYSOs was evaluated in terms of flood histogram, energy resolution, timing resolution, and DOI resolution. The SiPM arrays have a pitch size of 1.2 mm. Eac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9fc9

    authors: Du J,Bai X,Cherry SR

    更新日期:2020-08-19 00:00:00

  • A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

    abstract::We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/9/310

    authors: Ferreira NC,Trébossen R,Lartizien C,Brulon V,Merceron P,Bendriem B

    更新日期:2002-05-07 00:00:00

  • Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width.

    abstract::The spatial resolution of 2D detector arrays equipped with ionization chambers or diodes, used for the dose verification of IMRT treatment plans, is limited by the size of the single detector and the centre-to-centre distance between the detectors. Optimization criteria with regard to these parameters have been develo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/019

    authors: Poppe B,Djouguela A,Blechschmidt A,Willborn K,Rühmann A,Harder D

    更新日期:2007-05-21 00:00:00

  • Numerical calculation of energy deposition by broad high-energy electron beams.

    abstract::The feasibility is demonstrated of a numerical method to calculate dose deposition by broad high-energy electron beams in homogeneous matter or in heterogeneous matter in which the heterogeneities are arranged in slabs perpendicular to the beam axis. The method is based only on the basic physical interaction processes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/10/003

    authors: Huizenga H,Storchi PR

    更新日期:1989-10-01 00:00:00

  • Using surface markers for MRI guided breast conserving surgery: a feasibility survey.

    abstract::Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient's pos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1589

    authors: Ebrahimi M,Siegler P,Modhafar A,Holloway CM,Plewes DB,Martel AL

    更新日期:2014-04-07 00:00:00

  • Measurement and correction of the effects of lag on contrast-detail test results in fluoroscopy.

    abstract::Persistence of the video signal between TV frames, an effect also known as image lag, can lead to anomalously good contrast-detail test results for fluoroscopy systems. In this practical paper, a simple method is described which quantifies lag in fluoroscopy systems and corrects for its effect on threshold contrast. A...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:

    authors: Marshall NW,Kotre CJ

    更新日期:2002-03-21 00:00:00

  • Bayesian multiresolution method for local tomography in dental x-ray imaging.

    abstract::Dental tomographic cone-beam x-ray imaging devices record truncated projections and reconstruct a region of interest (ROI) inside the head. Image reconstruction from the resulting local tomography data is an ill-posed inverse problem. A new Bayesian multiresolution method is proposed for local tomography reconstructio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/22/008

    authors: Niinimäki K,Siltanen S,Kolehmainen V

    更新日期:2007-11-21 00:00:00

  • The local noise property in positron volume imaging and optimal conditions for the signal-to-noise ratio of the 3D reconstructed image.

    abstract::The local noise property of a 3D PET reconstructed image is investigated for a uniform-activity sphere distributed in a constantly attenuating spherical object. The positional dependence of the statistical noise is approximately derived and calculated for some special cases. It is suggested that a larger diameter of t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/1/015

    authors: Murayama H,Nohara N

    更新日期:1997-01-01 00:00:00

  • Methods for the inclusion of shallow marrow and adipose tissue in pathlength-based skeletal dosimetry.

    abstract::Distributions of linear pathlength measurements have been utilized in skeletal dosimetry of internally emitted short-range particles for over 30 years. This work reviews the methods for coupling these distributions to range-energy data. A revised methodology is presented for handling the insertion of the additional do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/9/004

    authors: Jokisch DW,Rajon DA,Patton PW,Bolch WE

    更新日期:2011-05-07 00:00:00

  • The gastrointestinal absorption of plutonium and americium in the hamster.

    abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/015

    authors: Stather JW,Harrison JD,Rodwell P,David AJ

    更新日期:1979-03-01 00:00:00

  • Detection of in situ mammary cancer in a transgenic mouse model: in vitro and in vivo MRI studies demonstrate histopathologic correlation.

    abstract::Improving the prevention and detection of preinvasive ductal carcinoma in situ (DCIS) is expected to lower both morbidity and mortality from breast cancer. Transgenic mouse models can be used as a 'test bed' to develop new imaging methods and to evaluate the efficacy of candidate preventive therapies. We hypothesized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/19/014

    authors: Jansen SA,Conzen SD,Fan X,Krausz T,Zamora M,Foxley S,River J,Newstead GM,Karczmar GS

    更新日期:2008-10-07 00:00:00

  • Application of a CCD linear array camera in the quantification of tissue staining: NBT detection in ischaemic myocardium.

    abstract::A method was developed to quantify the intensity of tissue staining using a CCD (charge-coupled device) camera. Reflection spectra of NBT-stained (nitro-blue tetrazolium-stained) and unstained myocardium were recorded via fibre optics coupled to a CCD camera, connected to a microcomputer. The calculation of the intens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/6/007

    authors: Schröder T,Koch G,Schnabel PA,Hering JP,Bretschneider HJ,Richter J,Hellige G

    更新日期:1991-06-01 00:00:00

  • Extended three-compartment model for the transport and distribution of Hippuran.

    abstract::The distribution and transport of Hippuran is discussed. The activity leaving both kidneys has been calculated and compared with the bladder activity. It is shown that the Impulse Response Function of the ureter and bladder may be obtained by deconvolution, and data are presented relating to studies on one patient. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/2/002

    authors: Knesaurek K,Spaventi S

    更新日期:1981-03-01 00:00:00

  • Comparison of risk of radiogenic second cancer following photon and proton craniospinal irradiation for a pediatric medulloblastoma patient.

    abstract::Pediatric patients who received radiation therapy are at risk of developing side effects such as radiogenic second cancer. We compared proton and photon therapies in terms of the predicted risk of second cancers for a 4 year old medulloblastoma patient receiving craniospinal irradiation (CSI). Two CSI treatment plans ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/4/807

    authors: Zhang R,Howell RM,Giebeler A,Taddei PJ,Mahajan A,Newhauser WD

    更新日期:2013-02-21 00:00:00

  • Measurement of patient entrance surface dose rates for fluoroscopic x-ray units.

    abstract::Measurements of patient entrance surface dose rate provide valuable data for interpreting results from dose-area product studies on fluoroscopic x-ray equipment. Methods for measurement of entrance surface dose rate with backscatter and incident dose rate without backscatter have been investigated. Entrance surface do...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/5/008

    authors: Martin CJ

    更新日期:1995-05-01 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Laser speckle imaging of blood flow in microcirculation.

    abstract::Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scannin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/7/020

    authors: Cheng H,Luo Q,Liu Q,Lu Q,Gong H,Zeng S

    更新日期:2004-04-07 00:00:00

  • Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer.

    abstract::Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/014

    authors: Wootton JH,Prakash P,Hsu IC,Diederich CJ

    更新日期:2011-07-07 00:00:00

  • A basic dosimetric study of PRESAGE: the effect of different amounts of fabricating components on the sensitivity and stability of the dosimeter.

    abstract::Over the past few years there has been much interest in the development of three-dimensional dosimeters to determine the complex absorbed dose distribution in modern radiotherapy techniques such as IMRT and IGRT. In routine methods used for three-dimensional dosimetry, polymer gels are commonly used. Recently, a novel...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/3/023

    authors: Mostaar A,Hashemi B,Zahmatkesh MH,Aghamiri SM,Mahdavi SR

    更新日期:2010-02-07 00:00:00

  • Bulk optical properties of healthy female breast tissue.

    abstract::We have measured the bulk optical properties of healthy female breast tissues in vivo in the parallel plate, transmission geometry. Fifty-two volunteers were measured. Blood volume and blood oxygen saturation were derived from the optical property data using a novel method that employed a priori spectral information t...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/47/16/302

    authors: Durduran T,Choe R,Culver JP,Zubkov L,Holboke MJ,Giammarco J,Chance B,Yodh AG

    更新日期:2002-08-21 00:00:00

  • Numerical study of oxygen transport in a carotid bifurcation.

    abstract::This study investigates the oxygen mass transport in the region around the human carotid bifurcation, particularly addressing the effects of bifurcation geometry and pulsatile blood flow on the oxygen transport between the blood flow and artery wall tissue, coupled with the metabolic oxygen consumption and oxygen diff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/14/004

    authors: Tada S

    更新日期:2010-07-21 00:00:00

  • Single spectrum three-material decomposition with grating-based x-ray phase-contrast CT.

    abstract::Grating-based x-ray phase-contrast imaging provides three simultaneous image channels originating from a single image acquisition. While the phase signal provides direct access to the electron density in tomography, there is additional information on sub-resolutional structural information which is called dark-field s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab9704

    authors: Braig EM,Pfeiffer D,Willner M,Sellerer T,Taphorn K,Petrich C,Scholz J,Petzold L,Birnbacher L,Dierolf M,Pfeiffer F,Herzen J

    更新日期:2020-09-18 00:00:00

  • A search for improved technique factors in paediatric fluoroscopy.

    abstract::A Monte Carlo computational model of a fluoroscopic imaging chain was used for deriving optimal technique factors for paediatric fluoroscopy. The optimal technique was defined as the one that minimizes the absorbed dose (or dose rate) in the patient with a constraint of constant image quality. Image quality was assess...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/2/018

    authors: Tapiovaara MJ,Sandborg M,Dance DR

    更新日期:1999-02-01 00:00:00

  • Simultaneous optimization of RBE-weighted dose and nanometric ionization distributions in treatment planning with carbon ions.

    abstract::Inverse treatment planning in intensity modulated particle therapy (IMPT) with scanned carbon-ion beams is currently based on the optimization of RBE-weighted dose to satisfy requirements of target coverage and limited toxicity to organs-at-risk (OARs) and healthy tissues. There are many feasible IMPT plans that meet ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf400

    authors: Burigo LN,Ramos-Méndez J,Bangert M,Schulte RW,Faddegon B

    更新日期:2019-01-04 00:00:00

  • Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

    abstract::In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diamet...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaa4fb

    authors: Lai X,Meng LJ

    更新日期:2018-02-12 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • Beam characterisation of the 1.5 T MRI-linac.

    abstract::As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab566

    authors: Woodings SJ,Bluemink JJ,de Vries JHW,Niatsetski Y,van Veelen B,Schillings J,Kok JGM,Wolthaus JWH,Hackett SL,van Asselen B,van Zijp HM,Pencea S,Roberts DA,Lagendijk JJW,Raaymakers BW

    更新日期:2018-04-19 00:00:00

  • A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.

    abstract::A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/005

    authors: Pradhan AS,Quast U,Sharma PK

    更新日期:1994-09-01 00:00:00