The gastrointestinal absorption of plutonium and americium in the hamster.

Abstract:

:Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current knowledge, the best values for adults would appear to be: 0.05% for americium, 0.01% for plutonium ingested in soluble form, and 0.0001% for plutonium ingested as the dioxide. Plutonium dioxide should be considered as soluble if a significant proportion (greater than 5%) of the activity is in particles less than 25 nm in diameter.

journal_name

Phys Med Biol

authors

Stather JW,Harrison JD,Rodwell P,David AJ

doi

10.1088/0031-9155/24/2/015

subject

Has Abstract

pub_date

1979-03-01 00:00:00

pages

396-407

issue

2

eissn

0031-9155

issn

1361-6560

journal_volume

24

pub_type

杂志文章
  • PET monitoring of cancer therapy with 3He and 12C beams: a study with the GEANT4 toolkit.

    abstract::We study the spatial distributions of beta(+)-activity produced by therapeutic beams of (3)He and (12)C ions in various tissue-like materials. The calculations were performed within a Monte Carlo model for heavy-ion therapy (MCHIT) based on the GEANT4 toolkit. The contributions from positron-emitting nuclei with T(1/2...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/24/007

    authors: Pshenichnov I,Larionov A,Mishustin I,Greiner W

    更新日期:2007-12-21 00:00:00

  • Effects of f-number on the histotripsy intrinsic threshold and cavitation bubble cloud behavior.

    abstract::Histotripsy is an ultrasound ablation method that depends on the initiation of a cavitation bubble cloud to fractionate soft tissue. Although previous work has provided significant insight into the process of intrinsic threshold histotripsy, the majority of these studies have used highly focused (i.e. f-number  <  0.6...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa54c7

    authors: Vlaisavljevich E,Gerhardson T,Hall T,Xu Z

    更新日期:2017-02-21 00:00:00

  • Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca.

    abstract::The coincidence time resolution (CTR) becomes a key parameter of 511 keV gamma detection in time of flight positron emission tomography (TOF-PET). This is because additional information obtained through timing leads to a better noise suppression and therefore a better signal to noise ratio in the reconstructed image. ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/4635

    authors: Nemallapudi MV,Gundacker S,Lecoq P,Auffray E,Ferri A,Gola A,Piemonte C

    更新日期:2015-06-21 00:00:00

  • Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

    abstract::The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/7/006

    authors: Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

    更新日期:2006-04-07 00:00:00

  • Monitoring of airborne contamination during the handling of technetium-99m and radioiodine.

    abstract::Measurements have been made using an air sampler to measure airborne radioactivity produced during the routine handling of large activities of technetium-99m, iodine-125 and iodine-131. The results indicate that 99Tcm can be safely handled in environments without direct exhaust of the ventilated air but that 125I and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/25/6/005

    authors: Eadie AS,Horton PW,Hilditch TE

    更新日期:1980-11-01 00:00:00

  • Perturbation correction for alanine dosimeters in different phantom materials in high-energy photon beams.

    abstract::In modern radiotherapy the verification of complex treatments plans is often performed in inhomogeneous or even anthropomorphic phantoms. For dose verification small detectors are necessary and therefore alanine detectors are most suitable. Though the response of alanine for a wide range of clinical photon energies in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/3/N70

    authors: von Voigts-Rhetz P,Anton M,Vorwerk H,Zink K

    更新日期:2016-02-07 00:00:00

  • Stability analysis of a deterministic dose calculation for MRI-guided radiotherapy.

    abstract::Modern effort in radiotherapy to address the challenges of tumor localization and motion has led to the development of MRI guided radiotherapy technologies. Accurate dose calculations must properly account for the effects of the MRI magnetic fields. Previous work has investigated the accuracy of a deterministic linear...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa959a

    authors: Zelyak O,Fallone BG,St-Aubin J

    更新日期:2017-12-14 00:00:00

  • Staging of cervical cancer based on tumor heterogeneity characterized by texture features on (18)F-FDG PET images.

    abstract::The aim of the study is to assess the staging value of the tumor heterogeneity characterized by texture features and other commonly used semi-quantitative indices extracted from (18)F-FDG PET images of cervical cancer (CC) patients. Forty-two patients suffering CC at different stages were enrolled in this study. First...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/5123

    authors: Mu W,Chen Z,Liang Y,Shen W,Yang F,Dai R,Wu N,Tian J

    更新日期:2015-07-07 00:00:00

  • 2D convolution kernels of ionization chambers used for photon-beam dosimetry in magnetic fields: the advantage of small over large chamber dimensions.

    abstract::This study aims at developing an optimization strategy for photon-beam dosimetry in magnetic fields using ionization chambers. Similar to the familiar case in the absence of a magnetic field, detectors should be selected under the criterion that their measured 2D signal profiles M(x,y) approximate the absorbed dose to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab50c

    authors: Looe HK,Delfs B,Poppinga D,Harder D,Poppe B

    更新日期:2018-03-29 00:00:00

  • Four-dimensional Monte Carlo simulation of time-dependent geometries.

    abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/n03

    authors: Paganetti H

    更新日期:2004-03-21 00:00:00

  • A robust approach to IMRT optimization.

    abstract::Managing uncertainty is a major challenge in radiation therapy treatment planning, including uncertainty induced by intrafraction motion, which is particularly important for tumours in the thorax and abdomen. Common methods to account for motion are to introduce a margin or to convolve the static dose distribution wit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/10/014

    authors: Chan TC,Bortfeld T,Tsitsiklis JN

    更新日期:2006-05-21 00:00:00

  • Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer.

    abstract::Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for 'densities-of-the-day' was created: (1)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5c12

    authors: Jagt T,Breedveld S,van de Water S,Heijmen B,Hoogeman M

    更新日期:2017-06-07 00:00:00

  • A parallel adaptive finite element simplified spherical harmonics approximation solver for frequency domain fluorescence molecular imaging.

    abstract::Fluorescence molecular imaging/tomography may play an important future role in preclinical research and clinical diagnostics. Time- and frequency-domain fluorescence imaging can acquire more measurement information than the continuous wave (CW) counterpart, improving the image quality of fluorescence molecular tomogra...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/16/002

    authors: Lu Y,Zhu B,Shen H,Rasmussen JC,Wang G,Sevick-Muraca EM

    更新日期:2010-08-21 00:00:00

  • Experimental evaluation of fiber-interspaced antiscatter grids for large patient imaging with digital x-ray systems.

    abstract::Radiographic imaging of large patients is compromised by x-ray scatter. Optimization of digital x-ray imaging systems used for projection radiography requires the use of the best possible antiscatter grid. The performance of antiscatter grids used in conjunction with digital x-ray imaging systems can be characterized ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/16/010

    authors: Fetterly KA,Schueler BA

    更新日期:2007-08-21 00:00:00

  • Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning.

    abstract::Following the publication of ICRU Report 50, the concepts of GTV (gross tumour volume). CTV (clinical target volume) and PTV (planning target volume) are being used in radiotherapy planning with increasing frequency. In 3D planning, the GTV (or CTV) is normally outlined by the clinician in CT or MRI slices. The PTV is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/4/011

    authors: Stroom JC,Storchi PR

    更新日期:1997-04-01 00:00:00

  • Exploration and application of phenomenological RBE models for proton therapy.

    abstract::The relative biological effectiveness (RBE) of protons varies with multiple physical and biological factors. Phenomenological RBE models have been developed to include such factors in the estimation of a variable RBE, in contrast to the clinically applied constant RBE of 1.1. In this study, eleven published phenomenol...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aad9db

    authors: Rørvik E,Fjæra LF,Dahle TJ,Dale JE,Engeseth GM,Stokkevåg CH,Thörnqvist S,Ytre-Hauge KS

    更新日期:2018-09-13 00:00:00

  • Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing.

    abstract::Dual energy computed tomography (DECT) is currently a subject of extensive investigation. DECT is currently implemented using either a dual source scanner with high and low kVp data acquired from separate sources or a single source scanner with both high and low kVp data acquired in an alternating manner. Both methods...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/21/005

    authors: Szczykutowicz TP,Chen GH

    更新日期:2010-11-07 00:00:00

  • Dosimetric verification of open asymmetric photon fields calculated with a treatment planning system based on dose-to-energy-fluence concepts.

    abstract::Output normalized dose profiles for asymmetric open photon fields has been calculated using a commercial treatment planning system (TPS) based on a dose-to-energy-fluence concept. The model does not require any additional measurements for off-axis fields. Calculations are compared with measurements for quadratic field...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/8/003

    authors: Hurkmans C,Knöös T,Nilsson P

    更新日期:1996-08-01 00:00:00

  • On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios.

    abstract::The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/12/4412

    authors: Schmid G,Hirtl R

    更新日期:2016-06-21 00:00:00

  • Cross-sections for the inactivation of ribonuclease by slow heavy ions.

    abstract::Average cross-sections for inactivation of dry ribonuclease by H, He and N projectiles with energies between 100 eV and 10 keV are presented. The trend of the damage cross-sections with particle energy is consistent with the trend of the molecular quasi-elastic scattering and ionization cross-sections. A tentative rad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/6/005

    authors: Watt DE,Sutcliffe JF

    更新日期:1975-11-01 00:00:00

  • Mechanical analysis of an axially symmetric cylindrical phantom with a spherical heterogeneity for MR elastography.

    abstract::Cylindrical homogenous phantoms for magnetic resonance (MR) elastography in biomedical research provide one way to validate an imaging systems performance, but the simplified geometry and boundary conditions can cloak complexity arising at tissue interfaces. In an effort to develop a more realistic gel tissue phantom ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6821

    authors: Schwartz BL,Yin Z,Magin RL

    更新日期:2016-09-21 00:00:00

  • Quenching-free fluorescence signal from plastic-fibres in proton dosimetry: understanding the influence of Čerenkov radiation.

    abstract::The origin of photons emitted in optical fibres under proton irradiation has been attributed to either entirely Čerenkov radiation or light consisting of fluorescence with a substantial amount of Čerenkov radiation. The source of the light emission is assessed in order to understand why the signal from optical fibres ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaafad

    authors: Brage Christensen J,Almhagen E,Nyström H,Andersen CE

    更新日期:2018-03-09 00:00:00

  • Quantitative x-ray dark-field computed tomography.

    abstract::The basic principles of x-ray image formation in radiology have remained essentially unchanged since Röntgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpre...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/017

    authors: Bech M,Bunk O,Donath T,Feidenhans'l R,David C,Pfeiffer F

    更新日期:2010-09-21 00:00:00

  • The Akaike information criterion in DCE-MRI: does it improve the haemodynamic parameter estimates?

    abstract::The Akaike information criterion and the associated Akaike weights (AW) rank pharmacokinetic models on the basis of goodness-of-fit and number of parameters. The usefulness of this information for improving the haemodynamic parameter estimates from DCE-MRI was investigated through two examples. In each of these, the e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3609

    authors: Luypaert R,Ingrisch M,Sourbron S,de Mey J

    更新日期:2012-06-07 00:00:00

  • A study of the impact of x-ray tube performance on angiography system imaging efficiency.

    abstract::This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abbb7a

    authors: Dehairs M,Bosmans H,Marshall NW

    更新日期:2020-11-24 00:00:00

  • Automatic bladder segmentation on CBCT for multiple plan ART of bladder cancer using a patient-specific bladder model.

    abstract::In multiple plan adaptive radiotherapy (ART) strategies of bladder cancer, a library of plans corresponding to different bladder volumes is created based on images acquired in early treatment sessions. Subsequently, the plan for the smallest PTV safely covering the bladder on cone-beam CT (CBCT) is selected as the pla...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3945

    authors: Chai X,van Herk M,Betgen A,Hulshof M,Bel A

    更新日期:2012-06-21 00:00:00

  • A variable fluence step clustering and segmentation algorithm for step and shoot IMRT.

    abstract::A step and shoot sequencer was developed that can be integrated into an IMRT optimization algorithm. The method uses non-uniform fluence steps and is adopted to the constraints of an MLC. It consists of a clustering, a smoothing and a segmentation routine. The performance of the algorithm is demonstrated for eight mat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/7/319

    authors: Bär W,Alber M,Nüsslin F

    更新日期:2001-07-01 00:00:00

  • MR-compatibility assessment of MADPET4: a study of interferences between an SiPM-based PET insert and a 7 T MRI system.

    abstract::Compromises in the design of a positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system should minimize the deterioration of image quality in both modalities, particularly when simultaneous demanding acquisitions are performed. In this work, the advantages of using individually read-out ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab9d1

    authors: Omidvari N,Topping G,Cabello J,Paul S,Schwaiger M,Ziegler SI

    更新日期:2018-05-01 00:00:00

  • Simulations of a micro-PET system based on liquid xenon.

    abstract::The imaging performance of a high-resolution preclinical micro-positron emission tomography (micro-PET) system employing liquid xenon (LXe) as the gamma-ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection ionization chambers and two arrays of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/6/1685

    authors: Miceli A,Glister J,Andreyev A,Bryman D,Kurchaninov L,Lu P,Muennich A,Retiere F,Sossi V

    更新日期:2012-03-21 00:00:00

  • A static beam delivery device for fast scanning proton arc-therapy.

    abstract::Arc-therapy is a dose delivery technique regularly applied in photon radiation therapy, and is currently subject of great interest for proton therapy as well. In this technique, proton beams are aimed at a tumor from different continuous ranges of incident directions (so called "arcs"). This technique can potentially ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abe02b

    authors: Nesteruk KP,Bolsi A,Lomax AJ,Meer D,van de Water S,Schippers JM

    更新日期:2021-01-26 00:00:00