Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy.

Abstract:

:The potential of the variable-aperture collimator (VAC) in intensity-modulated radiation therapy (IMRT) has been evaluated by comparing its performance with that of the multi-leaf collimator (MLC). This comparison used a decomposition algorithm to find the series of collimator segments that would treat a given intensity-modulated beam (IMB). Collimator performance was measured using both the number of segments required to complete the IMB and the monitor-unit efficiency of the treatment. The VAC was modelled with aperture sizes from 4 x 4 cm to 20 x 20 cm, and these apertures were allowed to be located anywhere within the IMB. To enable a direct comparison, a similar scanning MLC was modelled at the same range of aperture sizes. Using both collimators, decompositions were run on 10 x 10 and 20 x 20 random IMBs with integer bixel values ranging from 1 to 10. Clinical IMBs from lung, head and neck, and pelvic patients were taken from a Pinnacle treatment-planning system and tested in the same manner. It was found that for all treatment sites, a small, scanning MLC performs as well or better than an equivalent sized VAC in both number of segments and monitor-unit efficiency, and would be an efficient choice for centres looking for a simple collimator for IMRT.

journal_name

Phys Med Biol

authors

Anderson JW,Symonds-Tayler R,Hartmann G,Echner G,Lang C,Schlegel W,Webb S

doi

10.1088/0031-9155/51/7/006

subject

Has Abstract

pub_date

2006-04-07 00:00:00

pages

1725-36

issue

7

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(06)11949-1

journal_volume

51

pub_type

杂志文章
  • Estimating cancer risk from dental cone-beam CT exposures based on skin dosimetry.

    abstract::The aim of this study was to measure entrance skin doses on patients undergoing cone-beam computed tomography (CBCT) examinations, to establish conversion factors between skin and organ doses, and to estimate cancer risk from CBCT exposures. 266 patients (age 8-83) were included, involving three imaging centres. CBCT ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/14/3877

    authors: Pauwels R,Cockmartin L,Ivanauskaité D,Urbonienė A,Gavala S,Donta C,Tsiklakis K,Jacobs R,Bosmans H,Bogaerts R,Horner K,SEDENTEXCT Project Consortium.

    更新日期:2014-07-21 00:00:00

  • Calculation of radiation exposures from patients to whom radioactive materials have been administered.

    abstract::Spreadsheet templates which calculate cumulative exposures to other persons from patients to whom radioactive materials have been administered have been developed by the authors. Calculations can be based on any specified single-, bi- or tri-exponential whole-body clearance rate and a diurnal (or any other periodic) c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/3/003

    authors: Cormack J,Shearer J

    更新日期:1998-03-01 00:00:00

  • Quantitative evaluation of regularized phase retrieval algorithms on bone scaffolds seeded with bone cells.

    abstract::In the field of regenerative medicine, there has been a growing interest in studying the combination of bone scaffolds and cells that can maximize newly formed bone. In-line phase-contrast x-ray tomography was used to image porous bone scaffolds (Skelite(©)), seeded with bone forming cells. This technique allows the q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/N215

    authors: Weber L,Langer M,Tavella S,Ruggiu A,Peyrin F

    更新日期:2016-05-07 00:00:00

  • A three-dimensional model-based partial volume correction strategy for gated cardiac mouse PET imaging.

    abstract::Quantification in cardiac mouse positron emission tomography (PET) imaging is limited by the imaging spatial resolution. Spillover of left ventricle (LV) myocardial activity into adjacent organs results in partial volume (PV) losses leading to underestimation of myocardial activity. A PV correction method was develope...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/13/4309

    authors: Dumouchel T,Thorn S,Kordos M,DaSilva J,Beanlands RS,deKemp RA

    更新日期:2012-07-07 00:00:00

  • Accounting for range uncertainties in the optimization of intensity modulated proton therapy.

    abstract::Treatment plans optimized for intensity modulated proton therapy (IMPT) may be sensitive to range variations. The dose distribution may deteriorate substantially when the actual range of a pencil beam does not match the assumed range. We present two treatment planning concepts for IMPT which incorporate range uncertai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/10/009

    authors: Unkelbach J,Chan TC,Bortfeld T

    更新日期:2007-05-21 00:00:00

  • Correlation between human and model observer performance for discrimination task in CT.

    abstract::Although physical metrics can objectively characterize computed tomography (CT) image quality, quantitative approaches to predict human observer performance are more accurate and clinically relevant. This study compared a modified channelized Hotelling model observer (CHO) with human observers in a shape discriminatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/13/3389

    authors: Zhang Y,Leng S,Yu L,Carter RE,McCollough CH

    更新日期:2014-07-07 00:00:00

  • Influence of the physical state and straggling on the computation of the radiation dose due to radon daughters deposited in the lung.

    abstract::The effect of the physical state (phase) of the absorbing medium and the energy straggling of the alpha particles on the calculation of the radiation dose due to the daughter products of radon deposited in the lung have been studied in detail. The stopping power data for alpha particles in water and water vapour have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/8/004

    authors: Haque AK,Al-affan IA

    更新日期:1987-08-01 00:00:00

  • Electric fields induced in humans and rodents by 60 Hz magnetic fields.

    abstract::Numerical computations are used to evaluate electric field dosimetry for high-resolution anatomically based inhomogeneous models of a human male child, and male and female rats and mice, under exposure to 60 Hz uniform magnetic field sources of three perpendicular orientations. The goal is to compare the child data to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/14/313

    authors: Dawson TW,Caputa K,Stuchly MA

    更新日期:2002-07-21 00:00:00

  • Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS).

    abstract::In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. Fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/9/003

    authors: Tsai JS

    更新日期:1996-09-01 00:00:00

  • The feasibility of estimating and imaging the mechanical behavior of poroelastic materials using axial strain elastography.

    abstract::In this paper, we have investigated the feasibility of imaging the mechanical behavior of poroelastic materials using axial strain elastography. Cylindrical samples obtained from poroelastic materials having different elastic and permeability properties were subjected to a constant compression force (a classical creep...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/11/020

    authors: Righetti R,Righetti M,Ophir J,Krouskop TA

    更新日期:2007-06-07 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • The Akaike information criterion in DCE-MRI: does it improve the haemodynamic parameter estimates?

    abstract::The Akaike information criterion and the associated Akaike weights (AW) rank pharmacokinetic models on the basis of goodness-of-fit and number of parameters. The usefulness of this information for improving the haemodynamic parameter estimates from DCE-MRI was investigated through two examples. In each of these, the e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/11/3609

    authors: Luypaert R,Ingrisch M,Sourbron S,de Mey J

    更新日期:2012-06-07 00:00:00

  • Depth of ionization chamber in water.

    abstract::The device developed by the authors and described here enables the user to measure the depth from the water surface to the point of measurement for a cylindrical ion chamber with a waterproof plastic cap in a water phantom, free of surface-tension error with a high precision. The device seeks vertical orientation and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/40/8/007

    authors: Tailor RC,Tello VM

    更新日期:1995-08-01 00:00:00

  • A new column-generation-based algorithm for VMAT treatment plan optimization.

    abstract::We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The alg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4569

    authors: Peng F,Jia X,Gu X,Epelman MA,Romeijn HE,Jiang SB

    更新日期:2012-07-21 00:00:00

  • Simultaneous determination of the dose and linear energy transfer (LET) of carbon-ion beams using radiochromic films.

    abstract::Radiochromic films are useful as dosimeters in high-precision radiotherapy owing to their high spatial resolution. However, when a particle beam is measured using a radiochromic film, the dose cannot be estimated accurately because the film darkness varies with variations in linear energy transfer (LET). This paper pr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8bf3

    authors: Kawashima M,Matsumura A,Souda H,Tashiro M

    更新日期:2020-06-15 00:00:00

  • Simulation of small-angle x-ray scattering from collagen fibrils and comparison with experimental patterns.

    abstract::Simulation of small-angle x-ray scattering from collagen in healthy and cancerous breast tissue may reveal detailed information on the structural changes in collagen. Collagen fibril is modelled as a cylinder with axially periodic step-function electron density, and packing is approximated by placing the cylinders in ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/22/012

    authors: Suhonen H,Fernández M,Serimaa R,Suortti P

    更新日期:2005-11-21 00:00:00

  • Comparison of 3D-OP-OSEM and 3D-FBP reconstruction algorithms for High-Resolution Research Tomograph studies: effects of randoms estimation methods.

    abstract::The High-Resolution Research Tomograph (HRRT) is a dedicated human brain positron emission tomography (PET) scanner. Recently, a 3D filtered backprojection (3D-FBP) reconstruction method has been implemented to reduce bias in short duration frames, currently observed in 3D ordinary Poisson OSEM (3D-OP-OSEM) reconstruc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/12/010

    authors: van Velden FH,Kloet RW,van Berckel BN,Wolfensberger SP,Lammertsma AA,Boellaard R

    更新日期:2008-06-21 00:00:00

  • CT reconstruction algorithm for a dental panoramic x-ray unit.

    abstract::A variable Jacobian and weighted backprojection algorithm, used for medical CT, was adapted to perform CT reconstructions on data obtained with a dental panoramic x-ray unit. A detector array, fitted to the unit for the purpose of acquiring digital panoramic radiographs, was used to collect the data. Compensations wer...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/12/001

    authors: Lee MD,Waggener RG,McDavid WD,Dove SB,Welander U,Tronje G

    更新日期:1992-12-01 00:00:00

  • Review of photon interaction cross section data in the medical and biological context.

    abstract::The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), wh...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/44/1/001

    authors: Hubbell JH

    更新日期:1999-01-01 00:00:00

  • The gastrointestinal absorption of plutonium and americium in the hamster.

    abstract::Plutonium-239 and americium-241 were administered to adult hamsters in various chemical forms and their absorption from the gut was measured. The results have been compared with published data on other species in order to derive values for the estimated absorption of these actinides in man. On the basis of current kno...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/2/015

    authors: Stather JW,Harrison JD,Rodwell P,David AJ

    更新日期:1979-03-01 00:00:00

  • Measuring the acoustoelectric interaction constant using ultrasound current source density imaging.

    abstract::Ultrasound current source density imaging (UCSDI) exploits the acoustoelectric (AE) effect, an interaction between ultrasound pressure and electrical resistivity, to map electrical conduction in the heart. The conversion efficiency for UCSDI is determined by the AE interaction constant K, a fundamental property of all...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/19/5929

    authors: Li Q,Olafsson R,Ingram P,Wang Z,Witte R

    更新日期:2012-10-07 00:00:00

  • Sparse-view x-ray CT reconstruction via total generalized variation regularization.

    abstract::Sparse-view CT reconstruction algorithms via total variation (TV) optimize the data iteratively on the basis of a noise- and artifact-reducing model, resulting in significant radiation dose reduction while maintaining image quality. However, the piecewise constant assumption of TV minimization often leads to the appea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/12/2997

    authors: Niu S,Gao Y,Bian Z,Huang J,Chen W,Yu G,Liang Z,Ma J

    更新日期:2014-06-21 00:00:00

  • SAR calculations in an anatomically realistic model of the head for mobile communication transceivers at 900 MHz and 1.8 GHz.

    abstract::A new mathematical model of the head has been constructed from a set of serial MRI slices from one subject. Finite-difference time-domain (FDTD) calculations of the specific energy absorption rate (SAR) have been performed on this model with a 2 mm resolution for a generic mobile communication transceiver represented ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/10/003

    authors: Dimbylow PJ,Mann SM

    更新日期:1994-10-01 00:00:00

  • In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm.

    abstract::The optical properties (absorption and scattering coefficients and the scattering anisotropy factor) were measured in vitro for cartilage, liver, lung, muscle, myocardium, skin, and tumour (colon adenocarcinoma CC 531) at 630, 632.8, 790, 850 and 1064 nm. Rabbits, rats, piglets, goats, and dogs were used to obtain the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/11/017

    authors: Beek JF,Blokland P,Posthumus P,Aalders M,Pickering JW,Sterenborg HJ,van Gemert MJ

    更新日期:1997-11-01 00:00:00

  • Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy.

    abstract::X-ray scatter is a significant problem in cone-beam computed tomography when thicker objects and larger cone angles are used, as scattered radiation can lead to reduced contrast and CT number inaccuracy. Advances have been made in x-ray computed tomography (CT) by incorporating a high quality prior image into the imag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/4/009

    authors: Brunner S,Nett BE,Tolakanahalli R,Chen GH

    更新日期:2011-02-21 00:00:00

  • Analytic treatment of resolution precision in electronically collimated SPECT imaging involving multiple-interaction gamma rays.

    abstract::The widely applied single-interaction analytic expression characterizing the energy resolution component of the angular resolution precision for an electronically collimated point source is extended to include multiple-interaction Compton scatter sequences as well as sequences terminated by photoelectric absorption. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/10/021

    authors: Durkee JW Jr,Antich PP,Tsyganov EN,Constantinescu A,Kulkarni PV,Smith BJ,Arbique GM,Lewis MA,Nguyen T,Raheja A,Thambi G,Parkey RW

    更新日期:1998-10-01 00:00:00

  • Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

    abstract::Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (q...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4683

    authors: Tan S,Yao J,Yao L,Ward MM

    更新日期:2012-07-21 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

    abstract::The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an approximately 230 to approximately 460 microm thick layer of HgI2 (fabricated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/12/012

    authors: Su Z,Antonuk LE,El-Mohri Y,Hu L,Du H,Sawant A,Li Y,Wang Y,Yamamoto J,Zhao Q

    更新日期:2005-06-21 00:00:00

  • A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

    abstract::We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically couple...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/18/6635

    authors: Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

    更新日期:2016-09-21 00:00:00