A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

Abstract:

:We propose a novel scintillation detector design for positron emission tomography (PET), which has depth of interaction (DOI) capability and uses a single-ended readout scheme. The DOI detector contains a pair of crystal bars segmented using sub-surface laser engraving (SSLE). The two crystal bars are optically coupled to each other at their top segments and are coupled to two photo-sensors at their bottom segments. Initially, we evaluated the performance of different designs of single crystal bars coupled to photomultiplier tubes at both ends. We found that segmentation by SSLE results in superior performance compared to the conventional method. As the next step, we constructed a crystal unit composed of a 3  ×  3  ×  20 mm3 crystal bar pair, with each bar containing four layers segmented using the SSLE. We measured the DOI performance by changing the optical conditions for the crystal unit. Based on the experimental results, we then assessed the detector performance in terms of the DOI capability by evaluating the position error, energy resolution, and light collection efficiency for various crystal unit designs with different bar sizes and a different number of layers (four to seven layers). DOI encoding with small position error was achieved for crystal units composed of a 3  ×  3  ×  20 mm3 LYSO bar pair having up to seven layers, and with those composed of a 2  ×  2  ×  20 mm3 LYSO bar pair having up to six layers. The energy resolution of the segment in the seven-layer 3  ×  3  ×  20 mm3 crystal bar pair was 9.3%-15.5% for 662 keV gamma-rays, where the segments closer to the photo-sensors provided better energy resolution. SSLE provides high geometrical accuracy at low production cost due to the simplicity of the crystal assembly. Therefore, the proposed DOI detector is expected to be an attractive choice for practical small-bore PET systems dedicated to imaging of the brain, breast, and small animals.

journal_name

Phys Med Biol

authors

Uchida H,Sakai T,Yamauchi H,Hakamata K,Shimizu K,Yamashita T

doi

10.1088/0031-9155/61/18/6635

subject

Has Abstract

pub_date

2016-09-21 00:00:00

pages

6635-6650

issue

18

eissn

0031-9155

issn

1361-6560

journal_volume

61

pub_type

杂志文章
  • Modelling pencil-beam divergence with the electron pencil-beam redefinition algorithm.

    abstract::The electron pencil-beam redefinition algorithm (PBRA), which is used to calculate electron beam dose distributions, assumes that the virtual source of each pencil beam is identical to that of the broad beam incident on the patient. In the present work, a virtual source specific for each pencil beam is modelled by inc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/11/306

    authors: Boyd RA,Hogstrom KR,White RA,Starkschall G

    更新日期:2001-11-01 00:00:00

  • Achieving reliable coincidence resolving time measurement of PET detectors using multichannel waveform digitizer based on DRS4 chip.

    abstract::Coincidence resolving time (CRT) is one of the most important physical-performance measures for positron emission tomography (PET), as reconstruction with accurate time-of-flight information enhances the lesion detectability in patient studies. Accordingly, various PET detector designs and high-performance front-end r...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf0bb

    authors: Park H,Lee S,Ko GB,Lee JS

    更新日期:2018-12-10 00:00:00

  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • Motion correction of respiratory-gated PET images using deep learning based image registration framework.

    abstract::Artifacts caused by patient breathing and movement during PET data acquisition affect image quality. Respiratory gating is commonly used to gate the list-mode PET data into multiple bins over a respiratory cycle. Non-rigid registration of respiratory-gated PET images can reduce motion artifacts and preserve count stat...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab8688

    authors: Li T,Zhang M,Qi W,Asma E,Qi J

    更新日期:2020-07-30 00:00:00

  • A new column-generation-based algorithm for VMAT treatment plan optimization.

    abstract::We study the treatment plan optimization problem for volumetric modulated arc therapy (VMAT). We propose a new column-generation-based algorithm that takes into account bounds on the gantry speed and dose rate, as well as an upper bound on the rate of change of the gantry speed, in addition to MLC constraints. The alg...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/14/4569

    authors: Peng F,Jia X,Gu X,Epelman MA,Romeijn HE,Jiang SB

    更新日期:2012-07-21 00:00:00

  • Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter.

    abstract::A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships be...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1773

    authors: Eyadeh MM,Farrell TJ,Diamond KR

    更新日期:2014-04-07 00:00:00

  • Development and validation of a BEAMnrc component module for accurate Monte Carlo modelling of the Varian dynamic Millennium multileaf collimator.

    abstract::A new component module (CM), designated DYNVMLC, was developed to fully model the geometry of the Varian Millennium 120 leaf collimator using the BEAMnrc Monte Carlo code. The model includes details such as the leaf driving screw hole, support railing groove and leaf tips. Further modifications also allow sampling of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/24/004

    authors: Heath E,Seuntjens J

    更新日期:2003-12-21 00:00:00

  • Factors affecting the repeatability of gamma camera calibration for quantitative imaging applications using a sealed source.

    abstract::Several applications in nuclear medicine require absolute activity quantification of single photon emission computed tomography images. Obtaining a repeatable calibration factor that converts voxel values to activity units is essential for these applications. Because source preparation and measurement of the source ac...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/1325

    authors: Anizan N,Wang H,Zhou XC,Wahl RL,Frey EC

    更新日期:2015-02-07 00:00:00

  • A 4D biomechanical lung phantom for joint segmentation/registration evaluation.

    abstract::At present, there exists few openly available methods for evaluation of simultaneous segmentation and registration algorithms. These methods allow for a combination of both techniques to track the tumor in complex settings such as adaptive radiotherapy. We have produced a quality assurance platform for evaluating this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/19/7012

    authors: Markel D,Levesque I,Larkin J,Léger P,El Naqa I

    更新日期:2016-10-07 00:00:00

  • Three-dimensional FDTD simulation of biomaterial exposure to electromagnetic nanopulses.

    abstract::Ultra-wideband (UWB) electromagnetic pulses of nanosecond duration, or nanopulses, have recently been approved by the Federal Communications Commission for a number of different applications. They are also being explored for applications in biotechnology and medicine. The simulation of the propagation of a nanopulse t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/21/007

    authors: Simicevic N

    更新日期:2005-11-07 00:00:00

  • The exponential edge-gradient effect in x-ray computed tomography.

    abstract::The exponential edge-gradient effect must arise in any x-ray transmission CT scanner whenever long sharp edges of high contrast are encountered. The effect is non-linear and is due to the interaction of the exponential law of x-ray attenuation and the finite width of the scanning beam in the x-y plane. The error induc...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/010

    authors: Joseph PM,Spital RD

    更新日期:1981-05-01 00:00:00

  • Integration of dynamic contrast-enhanced magnetic resonance imaging and T2-weighted imaging radiomic features by a canonical correlation analysis-based feature fusion method to predict histological grade in ductal breast carcinoma.

    abstract::Tumour histological grade has prognostic implications in breast cancer. Tumour features in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and T2-weighted (T2W) imaging can provide related and complementary information in the analysis of breast lesions to improve MRI-based histological status prediction...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3fd3

    authors: Fan M,Liu Z,Xie S,Xu M,Wang S,Gao X,Li L

    更新日期:2019-10-23 00:00:00

  • A modular Geant4 model of Leksell Gamma Knife Perfexion™.

    abstract::This work presents a Monte Carlo model of Leksell Gamma Knife Perfexion as well as the main parameters of the dose distribution in the standard phantom obtained using this model. The model is developed in the Geant4 simulation toolkit in a modular way which enables its reuse in other Perfexion studies. Large phase spa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/24/7609

    authors: Pipek J,Novotný J,Novotný J,Kozubíková P

    更新日期:2014-12-21 00:00:00

  • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artefacts.

    abstract::Practical dosimeters in brachytherapy, such as thermoluminescent dosimeters (TLD) and diodes, are usually calibrated against low-energy megavoltage beams. To measure absolute dose rate near a brachytherapy source, it is necessary to establish the energy response of the detector relative to that of the calibration ener...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/6/004

    authors: Das RK,Li Z,Perera H,Williamson JF

    更新日期:1996-06-01 00:00:00

  • Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

    abstract::Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5983

    authors: Ng JA,Booth J,Poulsen P,Kuncic Z,Keall PJ

    更新日期:2013-09-07 00:00:00

  • Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

    abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1c37

    authors: Du J,Bai X,Cherry SR

    更新日期:2019-08-07 00:00:00

  • Improved correction for the tissue fraction effect in lung PET/CT imaging.

    abstract::Recently, there has been an increased interest in imaging different pulmonary disorders using PET techniques. Previous work has shown, for static PET/CT, that air content in the lung influences reconstructed image values and that it is vital to correct for this 'tissue fraction effect' (TFE). In this paper, we extend ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7387

    authors: Holman BF,Cuplov V,Millner L,Hutton BF,Maher TM,Groves AM,Thielemans K

    更新日期:2015-09-21 00:00:00

  • Computational errors of the induced electric field in voxelized and tetrahedral anatomical head models exposed to spatially uniform and localized magnetic fields.

    abstract::At low and intermediate frequencies, the strength of the induced electric field is used as dosimetric quantity for human protection in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. To compute the induced electric field, numerical methods based on anatomically realistic voxel mo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5dfb

    authors: Soldati M,Laakso I

    更新日期:2020-01-10 00:00:00

  • Experimental characterization of two-dimensional pencil beam scanning proton spot profiles.

    abstract::Dose calculations of pencil beam scanning treatment plans rely on the accuracy of proton spot profiles; not only the primary component but also the broad tail components. Four films are placed at several locations in air and multiple depths in Solidwater® for six selected energies. The films used for the primary compo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/6193

    authors: Lin L,Ainsley CG,McDonough JE

    更新日期:2013-09-07 00:00:00

  • Intensity of the flash associated with laser-induced plasma in the eye.

    abstract::A bright flash of light is emitted by the plasma formed at the focus of an ophthalmic Nd: YAG laser. The purpose of this investigation is to determine whether the plasma flash constitutes a hazard to the operator. The intensity of the flash at the slit lamp eyepiece was measured and the experimentally derived value wa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/9/009

    authors: Moseley H,Allan D

    更新日期:1987-09-01 00:00:00

  • A novel approach with dual-sampling convolutional neural network for ultrasound image classification of breast tumors.

    abstract::Breast cancer is one of the leading causes of female cancer deaths. Early diagnosis with prophylactic may improve the patients' prognosis. So far ultrasound (US) imaging is a popular method in breast cancer diagnosis. However, its accuracy is bounded to traditional handcrafted feature methods and expertise. A novel me...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abc5c7

    authors: Xie J,Song X,Zhang W,Dong Q,Wang Y,Li F,Wan C

    更新日期:2020-10-29 00:00:00

  • Optimizing 4DCBCT projection allocation to respiratory bins.

    abstract::4D cone beam computed tomography (4DCBCT) is an emerging image guidance strategy used in radiotherapy where projections acquired during a scan are sorted into respiratory bins based on the respiratory phase or displacement. 4DCBCT reduces the motion blur caused by respiratory motion but increases streaking artefacts d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/19/5631

    authors: O'Brien RT,Kipritidis J,Shieh CC,Keall PJ

    更新日期:2014-10-07 00:00:00

  • Dictionary learning for data recovery in positron emission tomography.

    abstract::Compressed sensing (CS) aims to recover images from fewer measurements than that governed by the Nyquist sampling theorem. Most CS methods use analytical predefined sparsifying domains such as total variation, wavelets, curvelets, and finite transforms to perform this task. In this study, we evaluated the use of dicti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/15/5853

    authors: Valiollahzadeh S,Clark JW,Mawlawi O

    更新日期:2015-08-07 00:00:00

  • Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy.

    abstract::In this note a technique is described for direct aperture optimization of components deliverable by a variable aperture collimator (VAC) for intensity-modulated radiation therapy. The first key result found was that, provided a large number of VAC components were selected for optimization, the resulting fluence profil...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/5/n02

    authors: Webb S

    更新日期:2004-03-07 00:00:00

  • Beam angle selection incorporation of anatomical heterogeneities for pencil beam scanning charged-particle therapy.

    abstract::In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/61/24/8664

    authors: Toramatsu C,Inaniwa T

    更新日期:2016-12-21 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal.

    abstract::Four-dimensional (4D) methods strive to achieve highly conformal radiotherapy, particularly for lung and breast tumours, in the presence of respiratory-induced motion of tumours and normal tissues. Four-dimensional radiotherapy accounts for respiratory motion during imaging, planning and radiation delivery, and requir...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/1/304

    authors: Vedam SS,Keall PJ,Kini VR,Mostafavi H,Shukla HP,Mohan R

    更新日期:2003-01-07 00:00:00

  • Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound.

    abstract::Ultrasound may provide a quantitative technique for the characterization of cartilage changes typical of early osteoarthrosis. In this study, specific changes in bovine articular cartilage were induced using collagenase and chondroitinase ABC, enzymes that selectively degrade collagen fibril network and digest proteog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/303

    authors: Töyräs J,Rieppo J,Nieminen MT,Helminen HJ,Jurvelin JS

    更新日期:1999-11-01 00:00:00

  • Comparative behaviour of the dynamically penalized likelihood algorithm in inverse radiation therapy planning.

    abstract::This paper presents a description of tests carried out to compare the behaviour of five algorithms in inverse radiation therapy planning: (1) The Dynamically Penalized Likelihood (DPL), an algorithm based on statistical estimation theory; (2) an accelerated version of the same algorithm: (3) a new fast adaptive simula...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/10/309

    authors: Llacer J,Solberg TD,Promberger C

    更新日期:2001-10-01 00:00:00

  • Simultaneous imaging using Si-PM-based PET and MRI for development of an integrated PET/MRI system.

    abstract::The silicon photomultiplier (Si-PM) is a promising photo-detector for PET for use in magnetic resonance imaging (MRI) systems because it has high gain and is insensitive to static magnetic fields. Recently we developed a Si-PM-based depth-of-interaction PET system for small animals and performed simultaneous measureme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/2/N1

    authors: Yamamoto S,Watabe T,Watabe H,Aoki M,Sugiyama E,Imaizumi M,Kanai Y,Shimosegawa E,Hatazawa J

    更新日期:2012-01-21 00:00:00