Beam angle selection incorporation of anatomical heterogeneities for pencil beam scanning charged-particle therapy.

Abstract:

:In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. The sensitivity of a PBS plan to lateral tissue heterogeneities can be reduced by selecting appropriate beam angles. The purpose of this study is to develop a fast and accurate method of beam angle selection for PBS. The lateral tissue heterogeneity surrounding the path of the pencil beams at a given angle was quantified with the heterogeneity number representing the variation of the Bragg peak depth across the cross section of the beams using the stopping power ratio of body tissues with respect to water. To shorten the computation time, one-dimensional dose optimization was conducted along the central axis of the pencil beams as they were directed by the scanning magnets. The heterogeneity numbers were derived for all possible beam angles for treatment. The angles leading to the minimum mean heterogeneity number were selected as the optimal beam angle. Three clinical cases of head and neck cancer were used to evaluate the developed method. Dose distributions and their robustness to setup and range errors were evaluated for all tested angles, and their relation to the heterogeneity numbers was investigated. The mean heterogeneity number varied from 1.2 mm-10.6 mm in the evaluated cases. By selecting a field with a low mean heterogeneity number, target dose coverage and robustness against setup and range errors were improved. The developed method is simple, fast, accurate and applicable for beam angle selection in charged particle therapy with PBS.

journal_name

Phys Med Biol

authors

Toramatsu C,Inaniwa T

doi

10.1088/1361-6560/61/24/8664

subject

Has Abstract

pub_date

2016-12-21 00:00:00

pages

8664-8675

issue

24

eissn

0031-9155

issn

1361-6560

journal_volume

61

pub_type

杂志文章
  • Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy.

    abstract::Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5983

    authors: Ng JA,Booth J,Poulsen P,Kuncic Z,Keall PJ

    更新日期:2013-09-07 00:00:00

  • Controlled E-field gradient coils for MRI.

    abstract::Peripheral neural stimulation is a major problem in current gradient coil designs. Induced current problems in patients relate directly to gradient strength and modulation frequency. Present designs of gradient coil tend to limit ultra-high-speed imaging methods such as echo-planar imaging (EPI) and echo-volumar imagi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/7/001

    authors: Mansfield P,Haywood B

    更新日期:2008-04-07 00:00:00

  • An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

    abstract::To replace the conventional pinhole (normal cone-beam) collimator, a novel skew-slit collimator was previously proposed and a Novikov-type algorithm developed to reconstruct images using the skew-slit geometry. The goal of this paper is to develop a reconstruction algorithm that has better noise control than the Novik...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/23/018

    authors: Tang Q,Zeng GL,Huang Q

    更新日期:2006-12-07 00:00:00

  • Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction.

    abstract::Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for correcting them. The goal of this study was to investigate the validity of techniques for random coincidence estimation, with various low-energy thresholds (LETs). Sim...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/9/012

    authors: Torres-Espallardo I,Rafecas M,Spanoudaki V,McElroy DP,Ziegler SI

    更新日期:2008-05-07 00:00:00

  • Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact.

    abstract::EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/12/N241

    authors: Chowdhury ME,Mullinger KJ,Bowtell R

    更新日期:2015-06-21 00:00:00

  • The distribution of trace elements Ca, Fe, Cu and Zn and the determination of copper oxidation state in breast tumour tissue using muSRXRF and muXANES.

    abstract::A micro beam synchrotron x-ray fluorescence (muSRXRF) technique has been used to determine the localization of metals in primary invasive ductal carcinoma of breast. Nine samples were examined, all of which were formalin fixed tissues arranged as micro arrays of 1.0 mm diameter and 10 microm thickness. Cu was the part...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/11/018

    authors: Farquharson MJ,Al-Ebraheem A,Falkenberg G,Leek R,Harris AL,Bradley DA

    更新日期:2008-06-07 00:00:00

  • A method for acquiring random range uncertainty probability distributions in proton therapy.

    abstract::In treatment planning we depend upon accurate knowledge of geometric and range uncertainties. If the uncertainty model is inaccurate then the plan will produce under-dosing of the target and/or overdosing of OAR. We aim to provide a method for which centre and site-specific population range uncertainty due to inter-fr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa9502

    authors: Holloway SM,Holloway MD,Thomas SJ

    更新日期:2017-12-19 00:00:00

  • Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications.

    abstract::The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/5/005

    authors: Zoetelief J,Broerse JJ

    更新日期:1983-05-01 00:00:00

  • Scatter correction of cone-beam CT using a deep residual convolution neural network (DRCNN).

    abstract::Scatter correction is an essential technique to improve the image quality of cone-beam CT (CBCT). Although different scatter correction methods have been proposed in the literature, a standard solution is still being studied due to the limitations including accuracy, computation efficiency and generalization. In this ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab23a6

    authors: Jiang Y,Yang C,Yang P,Hu X,Luo C,Xue Y,Xu L,Hu X,Zhang L,Wang J,Sheng K,Niu T

    更新日期:2019-07-11 00:00:00

  • An adaptive technique for digital noise suppression in on-line portal imaging.

    abstract::Two complementary approaches to the noise suppression problem in on-line portal imaging have been analysed. Temporal filtering by image summation can substantially reduce the amount of noise in an image. In many cases, however, movements of the patient or the radiation source limit the time period over which the avera...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/3/011

    authors: Leszczynski KW,Shalev S,Cosby NS

    更新日期:1990-03-01 00:00:00

  • Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study.

    abstract::Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/8/011

    authors: Beekman FJ,Kamphuis C,Frey EC

    更新日期:1997-08-01 00:00:00

  • A new method for modelling the tongue-and-groove in treatment planning systems.

    abstract::Commercial TPSs typically model the tongue-and-groove (TG) by extending the projections of the leaf sides by a certain constant width. However, this model may produce discrepancies of as much as 7%-10% in the calculated average doses, especially for the High Definition multi-leaf collimator (MLC) (Hernandez et al 2017...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf098

    authors: Hernandez V,Vera-Sánchez JA,Vieillevigne L,Khamphan C,Saez J

    更新日期:2018-12-10 00:00:00

  • Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6,000 MHz.

    abstract::Currently, standards for the compliance testing of wireless devices are being extended to cover a wider frequency band and different usage patterns of mobile phones as well as of novel body-worn and handheld devices. As a consequence, not only the head but also strongly varying tissue distributions of the body are exp...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/19/014

    authors: Christ A,Samaras T,Klingenböck A,Kuster N

    更新日期:2006-10-07 00:00:00

  • Evolutionary pruning of transfer learned deep convolutional neural network for breast cancer diagnosis in digital breast tomosynthesis.

    abstract::Deep learning models are highly parameterized, resulting in difficulty in inference and transfer learning for image recognition tasks. In this work, we propose a layered pathway evolution method to compress a deep convolutional neural network (DCNN) for classification of masses in digital breast tomosynthesis (DBT). T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aabb5b

    authors: Samala RK,Chan HP,Hadjiiski LM,Helvie MA,Richter C,Cha K

    更新日期:2018-05-01 00:00:00

  • Ion concentration and haematocrit as determinants of impedance in an erythrocyte suspension model of renal medullary tissue.

    abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/11/011

    authors: Niewiadomski W,Sadowski J,Badzyńska B,Rasmussen SN

    更新日期:1990-11-01 00:00:00

  • A breathing thorax phantom with independently programmable 6D tumour motion for dosimetric measurements in radiation therapy.

    abstract::Irradiation of moving targets using a scanned ion beam can cause clinically intolerable under- and overdosages within the target volume due to the interplay effect. Several motion mitigation techniques such as gating, beam tracking and rescanning are currently investigated to overcome this restriction. To enable detai...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/8/2235

    authors: Steidl P,Richter D,Schuy C,Schubert E,Haberer T,Durante M,Bert C

    更新日期:2012-04-21 00:00:00

  • Effect of errors in the system matrix on maximum a posteriori image reconstruction.

    abstract::Statistically based iterative image reconstruction methods have been developed for emission tomography. One important component in iterative image reconstruction is the system matrix, which defines the mapping from the image space to the data space. Several groups have demonstrated that an accurate system matrix can i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/14/007

    authors: Qi J,Huesman RH

    更新日期:2005-07-21 00:00:00

  • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.

    abstract::Multileaf collimators (MLCs) have been in clinical use for many years and meanwhile are commonly used to deliver intensity-modulated radiotherapy (IMRT) beams. For this purpose it is important to know their dosimetric properties precisely, one of them being inter- and intraleaf leakage. The Siemens 160 MLC features a ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/2/N02

    authors: Klüter S,Sroka-Perez G,Schubert K,Debus J

    更新日期:2011-01-21 00:00:00

  • Robust principal component analysis-based four-dimensional computed tomography.

    abstract::The purpose of this paper for four-dimensional (4D) computed tomography (CT) is threefold. (1) A new spatiotemporal model is presented from the matrix perspective with the row dimension in space and the column dimension in time, namely the robust PCA (principal component analysis)-based 4D CT model. That is, instead o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/11/002

    authors: Gao H,Cai JF,Shen Z,Zhao H

    更新日期:2011-06-07 00:00:00

  • Dose rate calculations around 192Ir brachytherapy sources using a Sievert integration model.

    abstract::The classical Sievert integral method is a valuable tool for dose rate calculations around brachytherapy sources, combining simplicity with reasonable computational times. However, its accuracy in predicting dose rate anisotropy around 192Ir brachytherapy sources has been repeatedly put into question. In this work, we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/2/309

    authors: Karaiskos P,Angelopoulos A,Baras P,Rozaki-Mavrouli H,Sandilos P,Vlachos L,Sakelliou L

    更新日期:2000-02-01 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • High-resolution numerical model of the middle and inner ear for a detailed analysis of radio frequency absorption.

    abstract::In order to enable a detailed analysis of radio frequency (RF) absorption in the human middle and inner ear organs, a numerical model of these organs was developed at a spatial resolution of 0.1 mm, based on a real human tissue sample. The dielectric properties of the liquids (perilymph and endolymph) inside the bony ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/7/001

    authors: Schmid G,Uberbacher R,Samaras T,Jappel A,Baumgartner WD,Tschabitscher M,Mazal PR

    更新日期:2007-04-07 00:00:00

  • Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT.

    abstract::A complete characterization of spongiosa (bone marrow plus trabecular bone) is required to calculate the absorbed dose to active bone marrow. Due to the complex microanatomy, it is necessary to apply non-conventional imaging methods in nuclear medicine. The aim of this study is validating a phantomless quantification ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4476

    authors: Salas-Ramirez M,Tran-Gia J,Gbureck U,Kosmala A,Lassmann M

    更新日期:2019-10-16 00:00:00

  • Verification of absolute dose rates for intravascular brachytherapy beta sources.

    abstract::The absolute dose rate around beta sources for intravascular brachytherapy was measured with thin thermoluminescent (TL) dosimeters and radiochromic film. The calibration of these dosimeters was performed at the dose maximum in a 6 MeV electron beam of a linear accelerator. Compared to the values given by the manufact...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/8/311

    authors: Piessens M,Reynaert N

    更新日期:2000-08-01 00:00:00

  • Design optimization of multi-pinhole micro-SPECT configurations by signal detection tasks and system performance evaluations for mouse cardiac imaging.

    abstract::An optimized configuration of multi-pinhole aperture can improve the spatial resolution and the sensitivity of pinhole SPECT simultaneously. In this study, an optimization strategy of the multi-pinhole configuration with a small detector is proposed for mouse cardiac imaging. A 14 mm-diameter spherical field-of-view (...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/2/473

    authors: Lee MW,Lin WT,Chen YC

    更新日期:2015-01-21 00:00:00

  • Physical modelling of electroporation in close cell-to-cell proximity environments.

    abstract::Many applications of electroporation, especially those utilizing electrofusion and in-vivo electroporation, involve cell environments that include close cell-to-cell proximity and a wide range of target cell size. It is important to understand how this kind of environment may alter optimum electroporation electrical p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/12/012

    authors: Gaynor PT,Bodger PS

    更新日期:2006-06-21 00:00:00

  • Are phantoms useful for predicting the potential of dose reduction in full-field digital mammography?

    abstract::A phantom study was performed in full-field digital mammography to investigate the opportunity and the magnitude of a possible dose reduction that would leave the image quality above the accepted thresholds associated with some classical phantoms. This preliminary work is intended to lay the groundwork for a future cl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/8/015

    authors: Gennaro G,Katz L,Souchay H,Alberelli C,di Maggio C

    更新日期:2005-04-21 00:00:00

  • Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.

    abstract::Scattered doses, e.g. neutron doses in proton therapy, are of concern in radiation therapy. Although measured data are the gold standard, Monte Carlo simulations allow a more realistic consideration of patient anatomy via whole-body phantoms. When calculating neutron doses with Monte Carlo techniques, the dose can be ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/004

    authors: Jarlskog CZ,Paganetti H

    更新日期:2008-09-07 00:00:00

  • Estimation of renal scintigraphy parameters using a linear piecewise-continuous model.

    abstract::Instead of performing a numerical deconvolution, we propose to use a linear piecewise-continuous model of the renal impulse response function for parametric fitting of renal scintigraphy data, to obtain clinically useful renal parameters. The strengths of the present model are its simplicity and speed of computation, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/12/402

    authors: Zhang JL,Zhang L,Koh TS,Shuter B

    更新日期:2003-06-21 00:00:00

  • A novel description of FDG excretion in the renal system: application to metformin-treated models.

    abstract::This paper introduces a novel compartmental model describing the excretion of 18F-fluoro-deoxyglucose (FDG) in the renal system and a numerical method based on the maximum likelihood for its reduction. This approach accounts for variations in FDG concentration due to water re-absorption in renal tubules and the increa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/10/2469

    authors: Garbarino S,Caviglia G,Sambuceti G,Benvenuto F,Piana M

    更新日期:2014-05-21 00:00:00