Sensitivity of different dose scoring methods on organ-specific neutron dose calculations in proton therapy.

Abstract:

:Scattered doses, e.g. neutron doses in proton therapy, are of concern in radiation therapy. Although measured data are the gold standard, Monte Carlo simulations allow a more realistic consideration of patient anatomy via whole-body phantoms. When calculating neutron doses with Monte Carlo techniques, the dose can be scored in different ways because neutrons deposit dose indirectly. The purpose of this study was to assess the differences in neutron dose predictions when using different dose scoring methods. Two methods were tested. In the first method, the organ dose was calculated by accumulating dose from each individual dose deposition event with a particle-specific radiation weighting factor applied. Alternatively, we applied a method where the calculation was done by averaging the dose over the total number of events irrespective of particle type and applying average neutron radiation weighting factors. In addition, we assessed the sensitivity of different neutron quality factor assignments based on two recommendations by the International Commission on Radiological Protection (ICRP). We found that the scoring procedure can lead to differences in the organ equivalent dose of about 25%. As to the ICRP definition of neutron quality factors, the most recent recommendation results in about 10% higher organ doses.

journal_name

Phys Med Biol

authors

Jarlskog CZ,Paganetti H

doi

10.1088/0031-9155/53/17/004

subject

Has Abstract

pub_date

2008-09-07 00:00:00

pages

4523-32

issue

17

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(08)70722-X

journal_volume

53

pub_type

杂志文章
  • Block matching 3D random noise filtering for absorption optical projection tomography.

    abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/009

    authors: Fumene Feruglio P,Vinegoni C,Gros J,Sbarbati A,Weissleder R

    更新日期:2010-09-21 00:00:00

  • A dose calculation method including scatter for IMRT optimization.

    abstract::IMRT optimization is an iterative process in which many dose calculations may be necessary. A fast and accurate dose calculation engine is essential for the optimization program to converge to a reliable solution in a reasonable time. Previously we developed a fast dose calculation method for IMRT optimization based o...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/19/011

    authors: Wu Q

    更新日期:2004-10-07 00:00:00

  • Modelling of the dielectric properties of normal and irradiated skin.

    abstract::We have shown that irradiation changes the dielectric properties of human skin at radiofrequencies. Both the dielectric constant and the conductivity of the irradiated skin decrease, especially at low frequencies. The experimental data were analysed using two bioelectric models. Relevant dielectric parameters were det...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/6/001

    authors: Tamura T,Tenhunen M,Lahtinen T,Repo T,Schwan HP

    更新日期:1994-06-01 00:00:00

  • Cadmium in man measured in vivo by x-ray fluorescence analysis.

    abstract::The sensitivity and detection limit for measurements of the concentration of cadmium in the kidney cortex of man in vivo have been investigated using the technique of X-ray fluorescence. An 11 GB1 241Am source was used to generate the characteristic K alpha X-rays of cadmium. The variation in the sensitivity for the d...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/1/004

    authors: Ahlgren L,Mattsson S

    更新日期:1981-01-01 00:00:00

  • Monte Carlo calculation of VMAT and helical tomotherapy dose distributions for lung stereotactic treatments with intra-fraction motion.

    abstract::The aim of this study is to calculate realistic dose distributions that include the continuous deformation of organs and continuous motion of machine using 4D Monte Carlo methods for both volumetric modulated arc therapy and helical tomotherapy treatments. As part of a previous study, we presented a method to perform ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/9/2807

    authors: Belec J,Clark BG

    更新日期:2013-05-07 00:00:00

  • Image reconstruction.

    abstract::We give an overview of the role of Physics in Medicine and Biology in the development of tomographic reconstruction algorithms. We focus on imaging modalities involving ionizing radiation, CT, PET and SPECT, and cover a wide spectrum of reconstruction problems, starting with classical 2D tomography in the 1970s up to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/13/R09

    authors: Defrise M,Gullberg GT

    更新日期:2006-07-07 00:00:00

  • Image quality assessment in digital mammography: part II. NPWE as a validated alternative for contrast detail analysis.

    abstract::Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/14/003

    authors: Monnin P,Marshall NW,Bosmans H,Bochud FO,Verdun FR

    更新日期:2011-07-21 00:00:00

  • Development of a Si-PM-based high-resolution PET system for small animals.

    abstract::A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 × ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/19/013

    authors: Yamamoto S,Imaizumi M,Watabe T,Watabe H,Kanai Y,Shimosegawa E,Hatazawa J

    更新日期:2010-10-07 00:00:00

  • Evaluation of the basic properties of the BANGkit gel dosimeter.

    abstract::We evaluated the basic properties of a commercially available BANGkit gel dosimeter, which is a normoxic type of BANG gel. This gel-kit has the same composition as the BANG 3 gel, but is fully oxygenated. To exclude oxygen, oxygen scavenging ascorbic acid and copper sulfate as a catalyst are used. The properties that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/8/017

    authors: Murakami Y,Nakashima T,Watanabe Y,Akimitsu T,Matsuura K,Kenjo M,Kaneyasu Y,Wadasaki K,Hirokawa Y,Ito K

    更新日期:2007-04-21 00:00:00

  • Rotational IMRT delivery using a digital linear accelerator in very high dose rate 'burst mode'.

    abstract::Recently, there has been a resurgence of interest in arc-based IMRT, through the use of 'conventional' multileaf collimator (MLC) systems that can treat large tumor volumes in a single, or very few pass(es) of the gantry. Here we present a novel 'burst mode' modulated arc delivery approach, wherein 2000 monitor units ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/002

    authors: Salter BJ,Sarkar V,Wang B,Shukla H,Szegedi M,Rassiah-Szegedi P

    更新日期:2011-04-07 00:00:00

  • Automatic generation of time resolved motion vector fields of coronary arteries and 4D surface extraction using rotational x-ray angiography.

    abstract::Rotational coronary angiography provides a multitude of x-ray projections of the contrast agent enhanced coronary arteries along a given trajectory with parallel ECG recording. These data can be used to derive motion information of the coronary arteries including vessel displacement and pulsation. In this paper, a ful...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/1/004

    authors: Jandt U,Schäfer D,Grass M,Rasche V

    更新日期:2009-01-07 00:00:00

  • Electromagnetic redesign of the HYPERcollar applicator: toward improved deep local head-and-neck hyperthermia.

    abstract::Accumulating evidence shows that hyperthermia improves head-and-neck cancer treatment. Over the last decade, we introduced a radiofrequency applicator, named HYPERcollar, which enables local heating also of deep locations in this region. Based on clinical experience, we redesigned the HYPERcollar for improved comfort,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/17/5997

    authors: Togni P,Rijnen Z,Numan WC,Verhaart RF,Bakker JF,van Rhoon GC,Paulides MM

    更新日期:2013-09-07 00:00:00

  • A preclinical simulated dataset of S-values and investigation of the impact of rescaled organ masses using the MOBY phantom.

    abstract::Nuclear medicine and radiation therapy, although well established, are still rapidly evolving, by exploiting animal models, aiming to define precise dosimetry in molecular imaging protocols. The purpose of the present study was to create a dataset based on the MOBY phantom for the calculation of organ-to-organ S-value...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/6/2333

    authors: Kostou T,Papadimitroulas P,Loudos G,Kagadis GC

    更新日期:2016-03-21 00:00:00

  • A theoretical approach for non-equilibrium radiation dosimetry.

    abstract::This study presents a theoretical approach to the dosimetry for small and non-equilibrium radiation fields. We applied the newly developed VMCBC algorithm to the dosimetry for megavoltage photon beams using Monte Carlo techniques. The approach assumes that a Monte Carlo simulated beam can be calibrated per incident pa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/13/006

    authors: Ding GX,Duggan DM,Coffey CW

    更新日期:2008-07-07 00:00:00

  • Electric fields induced in humans and rodents by 60 Hz magnetic fields.

    abstract::Numerical computations are used to evaluate electric field dosimetry for high-resolution anatomically based inhomogeneous models of a human male child, and male and female rats and mice, under exposure to 60 Hz uniform magnetic field sources of three perpendicular orientations. The goal is to compare the child data to...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/14/313

    authors: Dawson TW,Caputa K,Stuchly MA

    更新日期:2002-07-21 00:00:00

  • Hemodynamics altered by placing helix stents in an aneurysm at a 45 degrees angle to the curved vessel.

    abstract::Flow visualization, particle image velocimetry and numerical computation have been complementarily performed to study the fluid flow inside a stented lateral aneurysm. The curved afferent vessel had an inner diameter of 5 mm. The diameters of the aneurysmal orifice, neck and fundus were 7 mm, 5 mm and 7.5 mm, respecti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/14/004

    authors: Liou TM,Li YC,Wang TC

    更新日期:2008-07-21 00:00:00

  • Including robustness in multi-criteria optimization for intensity-modulated proton therapy.

    abstract::We present a method to include robustness in a multi-criteria optimization (MCO) framework for intensity-modulated proton therapy (IMPT). The approach allows one to simultaneously explore the trade-off between different objectives as well as the trade-off between robustness and nominal plan quality. In MCO, a database...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/3/591

    authors: Chen W,Unkelbach J,Trofimov A,Madden T,Kooy H,Bortfeld T,Craft D

    更新日期:2012-02-07 00:00:00

  • Modeling late rectal toxicities based on a parameterized representation of the 3D dose distribution.

    abstract::Many models exist for predicting toxicities based on dose-volume histograms (DVHs) or dose-surface histograms (DSHs). This approach has several drawbacks as firstly the reduction of the dose distribution to a histogram results in the loss of spatial information and secondly the bins of the histograms are highly correl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/7/013

    authors: Buettner F,Gulliford SL,Webb S,Partridge M

    更新日期:2011-04-07 00:00:00

  • An in silico framework to analyze the anisotropic shear wave mechanics in cardiac shear wave elastography.

    abstract::Shear wave elastography (SWE) is a potential tool to non-invasively assess cardiac muscle stiffness. This study focused on the effect of the orthotropic material properties and mechanical loading on the performance of cardiac SWE, as it is known that these factors contribute to complex 3D anisotropic shear wave propag...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaaffe

    authors: Caenen A,Pernot M,Peirlinck M,Mertens L,Swillens A,Segers P

    更新日期:2018-03-23 00:00:00

  • Dual-head gamma camera system for intraoperative localization of radioactive seeds.

    abstract::Breast-conserving surgery is a standard option for the treatment of patients with early-stage breast cancer. This form of surgery may result in incomplete excision of the tumor. Iodine-125 labeled titanium seeds are currently used in clinical practice to reduce the number of incomplete excisions. It seems likely that ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/19/7655

    authors: Arsenali B,de Jong HW,Viergever MA,Dickerscheid DB,Beijst C,Gilhuijs KG

    更新日期:2015-10-07 00:00:00

  • A new approach to develop computer-aided detection schemes of digital mammograms.

    abstract::The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening e...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/11/4413

    authors: Tan M,Qian W,Pu J,Liu H,Zheng B

    更新日期:2015-06-07 00:00:00

  • Using surface markers for MRI guided breast conserving surgery: a feasibility survey.

    abstract::Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient's pos...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1589

    authors: Ebrahimi M,Siegler P,Modhafar A,Holloway CM,Plewes DB,Martel AL

    更新日期:2014-04-07 00:00:00

  • Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients.

    abstract::In recent years, particle therapy has become a widely accepted form of cancer treatment and technological advances in beam delivery technology (i.e. pencil beam scanning (PBS)) have enabled the application of highly conformal dose distributions to static targets. Current research focuses on the possibilities for the t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/22/7905

    authors: Bernatowicz K,Lomax AJ,Knopf A

    更新日期:2013-11-21 00:00:00

  • Liver-ultrasound based motion modelling to estimate 4D dose distributions for lung tumours in scanned proton therapy.

    abstract::Motion mitigation strategies are crucial for scanned particle therapy of mobile tumours in order to prevent geometrical target miss and interplay effects. We developed a patient-specific respiratory motion model based on simultaneously acquired time-resolved volumetric MRI and 2D abdominal ultrasound images. We presen...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abaa26

    authors: Giger AT,Krieger M,Jud C,Duetschler A,Salomir R,Bieri O,Bauman G,Nguyen D,Weber DC,Lomax AJ,Zhang Y,Cattin PC

    更新日期:2020-07-28 00:00:00

  • Accurate helical cone-beam CT reconstruction with redundant data.

    abstract::We present a new image reconstruction algorithm for helical cone-beam computed tomography (CT). This algorithm is designed for data collected at or near maximum pitch, and provides a theoretically exact and stable reconstruction while beneficially using all measured data. The main operations involved are a differentia...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/15/001

    authors: Schöndube H,Stierstorfer K,Noo F

    更新日期:2009-08-07 00:00:00

  • Aerosol particle impaction in the conducting airways.

    abstract::Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/7/001

    authors: Agnew JE,Pavia D,Clarke SW

    更新日期:1984-07-01 00:00:00

  • Physical characterization and performance comparison of active- and passive-pixel CMOS detectors for mammography.

    abstract::We investigated the physical characteristics of two complementary metal oxide semiconductor (CMOS) mammography detectors. The detectors featured 14-bit image acquisition, 50 microm detector element (del) size and an active area of 5 cm x 5 cm. One detector was a passive-pixel sensor (PPS) with signal amplification per...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/6/022

    authors: Elbakri IA,McIntosh BJ,Rickey DW

    更新日期:2009-03-21 00:00:00

  • Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    abstract::Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa58c9

    authors: Wang Y,Peng B,Jiang J

    更新日期:2017-03-07 00:00:00

  • Absorbed dose beam quality correction factors kappaQ for the NE2571 chamber in a 5 MV and a 10 MV photon beam.

    abstract::Dose to water (Dw) determination in clinical high-energy photon beams with ionization chambers calibrated in terms of absorbed dose to water has been proposed as an alternative to ionization chamber dosimetry based on air kerma calibrations. Dw in the clinical beam is derived using a kappaQ factor that scales the abso...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/3/002

    authors: Palmans H,Mondelaers W,Thierens H

    更新日期:1999-03-01 00:00:00

  • Aperture modulated arc therapy.

    abstract::We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/10/307

    authors: Crooks SM,Wu X,Takita C,Watzich M,Xing L

    更新日期:2003-05-21 00:00:00