Aerosol particle impaction in the conducting airways.

Abstract:

:Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studies is complicated by differing approaches to the quantitative estimation of physical factors determining deposition and by differing choices of anatomical data. Published formulae for predicting aerosol particle impaction are compared by applying them to the deposition of 5 micron particles in the human conducting airways using the morphological data of Weibel together with information from other sources about airways branching angles. The results indicate the range of deposition estimates that may be obtained from currently available impaction formulae. All but one of the formulae considered agree in indicating maximum deposition by impaction in, or close to, the segmental or subsegmental bronchi. Data are presented to indicate how the principal physical determinants of deposition depend on particle size, inhalation flow rate and lung volume during inhalation.

journal_name

Phys Med Biol

authors

Agnew JE,Pavia D,Clarke SW

doi

10.1088/0031-9155/29/7/001

subject

Has Abstract

pub_date

1984-07-01 00:00:00

pages

767-77

issue

7

eissn

0031-9155

issn

1361-6560

journal_volume

29

pub_type

杂志文章
  • Dosimetric verification in participating institutions in a stereotactic body radiotherapy trial for stage I non-small cell lung cancer: Japan clinical oncology group trial (JCOG0403).

    abstract::A multicentre phase II trial of stereotactic body radiotherapy for T1N0M0 non-small cell lung cancer was initiated in Japan as the Japan Clinical Oncology Group trial (JCOG0403). Before starting the trial, a decision was made to evaluate the treatment machine and treatment planning in participating institutions to min...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,多中心研究

    doi:10.1088/0031-9155/51/21/002

    authors: Nishio T,Kunieda E,Shirato H,Ishikura S,Onishi H,Tateoka K,Hiraoka M,Narita Y,Ikeda M,Goka T

    更新日期:2006-11-07 00:00:00

  • Dosimetry of 106Ru eye applicators with a p-type silicon detector.

    abstract::Beta emitting 106Ru-applicators are used to treat choroidal melanoma. In order to improve the accuracy and simplify the dosimetry of these applicators, the suitability of using a p-type silicon semiconductor detector has been investigated. The detector is calibrated in a low energy electron beam. An important property...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/36/7/005

    authors: Lax I

    更新日期:1991-07-01 00:00:00

  • Measurement of calcium in sections of a human skeleton using a reactor spectrum-in vivo activation analysis technique.

    abstract::Factors influencing the precision of measuring changes in the calcium content of sections of bone, including vertebrae, using reactor neutrons for partial body in vivo activation analysis have been examined and quantified. These factors include (a) the choice of incidient neutron spectrum, (b) the uniformity of activa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/20/1/007

    authors: Boddy K,Glaros D,Robertson I

    更新日期:1975-01-01 00:00:00

  • Hysteresis heating for the treatment of tumours.

    abstract::A method is described whereby, utilising a biocompatible magnetic glass-ceramic material, effective hysteresis heating in living tissue was accomplished. Initial experiments on mice showed that a significant heating effect can be obtained in the ceramic-impregnated regions. An analysis is also given for the projected ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/001

    authors: Borrelli NF,Luderer AA,Panzarino JN

    更新日期:1984-05-01 00:00:00

  • Magnetic resonance electrical property mapping at 21.1 T: a study of conductivity and permittivity in phantoms, ex vivo tissue and in vivo ischemia.

    abstract::Electrical properties (EP), namely conductivity and permittivity, can provide endogenous contrast for tissue characterization. Using electrical property tomography (EPT), maps of EP can be generated from conventional MRI data. This report investigates the feasibility and accuracy of EPT at 21.1 T for multiple RF coils...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3259

    authors: Amouzandeh G,Mentink-Vigier F,Helsper S,Bagdasarian FA,Rosenberg JT,Grant SC

    更新日期:2020-02-28 00:00:00

  • Power deposition in the head and neck of an anatomically based human body model for plane wave exposures.

    abstract::At certain frequencies, when the human head becomes a resonant structure, the power absorbed by the head and neck, when the body is exposed to a vertically polarized plane wave propagating from front to back, becomes significantly larger than would ordinarily be expected from its shadow cross section. This has possibl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/8/026

    authors: Tinniswood AD,Furse CM,Gandhi OP

    更新日期:1998-08-01 00:00:00

  • Application of the adaptive wavelet transform for analysis of blood flow oscillations in the human skin.

    abstract::An original method for the analysis of oscillations of cutaneous blood flow has been developed, which makes use of laser Doppler flowmetry (LDF) data and is based on the continuous wavelet transform and adaptive wavelet theory. The potential of the method has been demonstrated in experiments with the response of micro...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/21/005

    authors: Tankanag A,Chemeris N

    更新日期:2008-11-07 00:00:00

  • Impact of free-breathing CT on quantitative measurements of static and quiescent period-gated PET Images.

    abstract::Measurements of standardized uptake values (SUV) can vary due to many causes, including respiratory motion. Various methodologies have been introduced to correct for motion in PET, with quiescent-period-gated (QPG) PET being the most popular approach. QPG has been shown to improve PET image quantification compared to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1cdd

    authors: Meier JG,Einstein SA,Diab RH,Erasmus LJ,Xu G,Mawlawi OR

    更新日期:2019-05-16 00:00:00

  • A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements.

    abstract::Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its hea...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/22/010

    authors: ten Have AG,Gijsen FJ,Wentzel JJ,Slager CJ,Serruys PW,van der Steen AF

    更新日期:2006-11-21 00:00:00

  • Dielectric properties of supercooled cryoprotectant agents.

    abstract::The dielectric properties of glycerol, propylene glycol, ethylene glycol and dimethyl sulphoxide have been measured in various aqueous concentrations generally sufficient to allow supercooling rather than freezing. The temperature range investigated is from -80 degrees C to +20 degrees C and the frequency range is 100...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/10/014

    authors: Michelson SC,Evans S

    更新日期:1996-10-01 00:00:00

  • Beam characterisation of the 1.5 T MRI-linac.

    abstract::As a prerequisite for clinical treatments it was necessary to characterize the Elekta 1.5 T MRI-linac 7 MV FFF radiation beam. Following acceptance testing, beam characterization data were acquired with Semiflex 3D (PTW 31021), microDiamond (PTW 60019), and Farmer-type (PTW 30013 and IBA FC65-G) detectors in an Elekta...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aab566

    authors: Woodings SJ,Bluemink JJ,de Vries JHW,Niatsetski Y,van Veelen B,Schillings J,Kok JGM,Wolthaus JWH,Hackett SL,van Asselen B,van Zijp HM,Pencea S,Roberts DA,Lagendijk JJW,Raaymakers BW

    更新日期:2018-04-19 00:00:00

  • Block matching 3D random noise filtering for absorption optical projection tomography.

    abstract::Absorption and emission optical projection tomography (OPT), alternatively referred to as optical computed tomography (optical-CT) and optical-emission computed tomography (optical-ECT), are recently developed three-dimensional imaging techniques with value for developmental biology and ex vivo gene expression studies...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/18/009

    authors: Fumene Feruglio P,Vinegoni C,Gros J,Sbarbati A,Weissleder R

    更新日期:2010-09-21 00:00:00

  • A comparison of direct reconstruction algorithms in proton computed tomography.

    abstract::Several direct algorithms have been proposed to take into account the non-linear path of protons in the reconstruction of a proton CT (pCT) image. This paper presents a comparison between five of them, in terms of spatial resolution and relative stopping power (RSP) accuracy. Our comparison includes (1) a distance-dri...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7d53

    authors: Khellaf F,Krah N,Létang JM,Collins-Fekete CA,Rit S

    更新日期:2020-06-01 00:00:00

  • Scatter dose for wedged fields.

    abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/010

    authors: Brown LH,Siddon RL,Bjärngard BE

    更新日期:1987-10-01 00:00:00

  • Inverse treatment planning using volume-based objective functions.

    abstract::The results of optimization of inverse treatment plans depend on a choice of the objective function. Even when the optimal solution for a given cost function can be obtained, a better solution may exist for a given clinical scenario and it could be obtained with a revised objective function. In the approach presented ...

    journal_title:Physics in medicine and biology

    pub_type: 临床试验,杂志文章

    doi:10.1088/0031-9155/49/12/003

    authors: Bednarz G,Michalski D,Anne PR,Valicenti RK

    更新日期:2004-06-21 00:00:00

  • Image-guidance for surgical procedures.

    abstract::Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/51/14/R01

    authors: Peters TM

    更新日期:2006-07-21 00:00:00

  • Optimizing robot motion for robotic ultrasound-guided radiation therapy.

    abstract::An important aspect of robotic radiation therapy is active compensation of target motion. Recently, ultrasound has been proposed to obtain real-time volumetric images of abdominal organ motion. One approach to realize flexible probe placement throughout the treatment fraction is based on a robotic arm holding the ultr...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab3bfb

    authors: Schlüter M,Fürweger C,Schlaefer A

    更新日期:2019-10-04 00:00:00

  • Positron range in PET imaging: an alternative approach for assessing and correcting the blurring.

    abstract::Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Furthermore, the percentage of annihilation events within a given distance from the point of positron emission is releva...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/57/12/3931

    authors: Jødal L,Le Loirec C,Champion C

    更新日期:2012-06-21 00:00:00

  • Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images.

    abstract::A method is presented for extraction of intra and inter fraction motion of seeds/markers within the patient from cone beam CT (CBCT) projection images. The position of the marker is determined on each projection image and fitted to a function describing the projection of a fixed point onto the imaging panel at differe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/018

    authors: Marchant TE,Amer AM,Moore CJ

    更新日期:2008-02-21 00:00:00

  • Calculation of electron beam dose distributions for arbitrarily shaped fields.

    abstract::A method for the calculation of absorbed dose distributions of arbitrarily shaped electron beams is presented. Isodose distributions and output factors of treatment fields can be predicted with good accuracy, without the need for any dose measurement in the actual field. A Gaussian pencil beam model is employed with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/6/007

    authors: Bruinvis IA,Van Amstel A,Elevelt AJ,Van der Laarse R

    更新日期:1983-06-01 00:00:00

  • Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer.

    abstract::Proton therapy is very sensitive to daily density changes along the pencil beam paths. The purpose of this study is to develop and evaluate an automated method for adaptation of IMPT plans to compensate for these daily tissue density variations. A two-step restoration method for 'densities-of-the-day' was created: (1)...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5c12

    authors: Jagt T,Breedveld S,van de Water S,Heijmen B,Hoogeman M

    更新日期:2017-06-07 00:00:00

  • Verification of the super-omni wedge concept.

    abstract::This study verifies the concept of the super-omni wedge by validating its equations for effective wedge orientation and wedge angle and by comparing the dose distributions it produces with those produced by other wedge techniques. To validate the equations, we calculated dose distributions for 20 combinations of wedge...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/9/313

    authors: Dai J,Zhu Y,Wu X

    更新日期:2001-09-01 00:00:00

  • Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation.

    abstract::Pinhole SPECT is rapidly gaining popularity for imaging laboratory animals using gamma-emitting molecules. Penetration and scattering of gamma radiation in the pinhole edge material can account for a significant fraction of the total number of photons detected, particularly if the pinholes have small diameters. This s...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/8/001

    authors: van der Have F,Beekman FJ

    更新日期:2004-04-21 00:00:00

  • Automated detection of spinal centrelines, vertebral bodies and intervertebral discs in CT and MR images of lumbar spine.

    abstract::We propose a completely automated algorithm for the detection of the spinal centreline and the centres of vertebral bodies and intervertebral discs in images acquired by computed tomography (CT) and magnetic resonance (MR) imaging. The developed methods are based on the analysis of the geometry of spinal structures an...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/1/015

    authors: Stern D,Likar B,Pernus F,Vrtovec T

    更新日期:2010-01-07 00:00:00

  • The use of tonebursts as an alternative to broadband signals in the measurement of speed of sound in human cancellous bone.

    abstract::Speed of sound (SOS) measurements, typically made using 1 MHz broadband pulses, are increasingly used in the clinical diagnosis of bone disorders. Previous in vitro studies indicate that broadband ultrasound pulses are susceptible to distortion in cancellous bone, leading to imprecise arrival time and SOS measurements...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/45/7/317

    authors: Pollintine P,Haddaway MJ,Davie MW

    更新日期:2000-07-01 00:00:00

  • Prototyping a large field size IORT applicator for a mobile linear accelerator.

    abstract::The treatment of large tumors such as sarcomas with intra-operative radiotherapy using a Mobetron is often complicated because of the limited field size of the primary collimator and the available applicators (max Ø100 mm). To circumvent this limitation a prototype rectangular applicator of 80 x 150 mm(2) was designed...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/8/006

    authors: Janssen RW,Faddegon BA,Dries WJ

    更新日期:2008-04-21 00:00:00

  • Feasibility of replacing patient specific cutouts with a computer-controlled electron multileaf collimator.

    abstract::A motorized electron multileaf collimator (eMLC) was developed as an add-on device to the Varian linac for delivery of advanced electron beam therapy. It has previously been shown that electron beams collimated by an eMLC have very similar penumbra to those collimated by applicators and cutouts. Thus, manufacturing pa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/16/5653

    authors: Eldib A,Jin L,Li J,Ma CM

    更新日期:2013-08-21 00:00:00

  • Reassessing the clinical efficacy of two MR quantitative DSC PWI CBF algorithms following cross-calibration with PET images.

    abstract::Clinical cerebral blood flow (CBF) maps generated through dynamic- susceptibility contrast (DSC) magnetic resonance (MR) perfusion imaging are currently cross-calibrated with PET studies. The cross-calibration is achieved by rescaling the MR CBF values so that normal white matter CBF corresponds to 22 ml/100 g/min. Ex...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/50/6/014

    authors: Chen JJ,Frayne R,Smith MR

    更新日期:2005-03-21 00:00:00

  • Optimization of tumour control probability for heterogeneous tumours in fractionated radiotherapy treatment protocols.

    abstract::We find the dose distribution that maximizes the tumour control probability (TCP) for a fixed mean tumour dose per fraction. We consider a heterogeneous tumour volume having a radiation response characterized by the linear quadratic model with heterogeneous radiosensitivity and repopulation rate that may vary in time....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/3/005

    authors: Levin-Plotnik D,Hamilton RJ

    更新日期:2004-02-07 00:00:00

  • An experimental evaluation of the Agility MLC for motion-compensated VMAT delivery.

    abstract::An algorithm for dynamic multileaf-collimator (dMLC) tracking of a target performing a known a priori, rigid-body motion during volumetric modulated arc therapy (VMAT), has been experimentally validated and applied to investigate the potential of the Agility (Elekta AB, Stockholm, Sweden) multileaf-collimator (MLC) fo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/58/13/4643

    authors: Davies GA,Clowes P,Bedford JL,Evans PM,Webb S,Poludniowski G

    更新日期:2013-07-07 00:00:00